1.
Artigo em Inglês | MEDLINE | ID: mdl-35954558

RESUMO

Foot drop is a common disability in post-stroke patients and represents a challenge for the clinician. To date, ankle foot orthosis (AFO) combined with conventional rehabilitation is the gold standard of rehabilitation management. AFO has a palliative mechanical action without actively restoring the associated neural function. Functional electrical stimulation (FES), consisting of stimulation of the peroneal nerve pathway, represents an alternative approach. By providing an FES device (Bioness L-300, BIONESS, Valencia, CA, USA) for 6 months to a post-stroke 22-year-old woman with a foot drop, our goal was to quantify its potential benefit on walking capacity. The gait parameters and the temporal evolution of the speed were collected with a specific connected sole device (Feet Me®) during the 10-m walking, the time up and go, and the 6-minute walking tests with AFO, FES, or without any device (NO). As a result, the walking speed changes on 10-m were clinically significant with an increase from the baseline to 6 months in AFO (+0.14 m.s-1), FES (+0.36 m.s-1) and NO (+0.32 m.s-1) conditions. In addition, the speed decreased at about 4-min in the 6-minute walking test in NO and AFO conditions, while the speed increased in the FES conditions at baseline and after 1, 3, and 6 months. In addition to the walking performance improvement, monitoring the gait speed in an endurance test after an ecological rehabilitation training program helps to examine the walking performance in post-stroke patients and to propose a specific rehabilitation program.


Assuntos
Terapia por Estimulação Elétrica , Transtornos Neurológicos da Marcha , Neuropatias Fibulares , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Adulto , Estimulação Elétrica , Feminino , Marcha/fisiologia , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/terapia , Humanos , Neuropatias Fibulares/reabilitação , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/terapia , Resultado do Tratamento , Caminhada/fisiologia , Adulto Jovem
2.
Vet Radiol Ultrasound ; 48(6): 570-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18018732

RESUMO

In normal dogs and dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the left apical site. We hypothesized that aortic flow velocities could also be obtained from the right parasternal long-axis view, optimized for the placement of the Doppler cursor as parallel as possible into the aortic root. In 15 healthy dogs and 13 healthy cats, high-pulsed repetition frequency Doppler flow velocity measurements in the proximal aorta were performed using two-dimensional echocardiographic guidance. The mean [ +/- standard error of the mean (SEM)] peak aortic flow velocities in healthy dogs were as follows: subcostal site 1.46 +/- 0.05 m/s; apical site 1.12 +/- 0.06 m/s; right parasternal long-axis site 1.09 +/- 0.05 m/s. In healthy cats, the following peak aortic flow velocities were observed: apical site 0.87 +/- 0.03m/s; right parasternal long-axis site 0.87 +/- 0.03 m/s. Aortic flow velocities obtained from the subcostal site were significantly higher in healthy dogs than those obtained from the left apical and right parasternal long-axis site (P< 0.001). There was no statistical difference between the peak aortic flow velocities obtained from right parasternal long-axis and left apical transducer position in all groups. We conclude therefore that right parasternal long-axis and left apical-derived aortic flow velocities are similar and may be used interchangeably in healthy dogs and cats.


Assuntos
Aorta/fisiologia , Gatos/fisiologia , Cães/fisiologia , Fluxometria por Laser-Doppler/veterinária , Animais , Velocidade do Fluxo Sanguíneo , Feminino , Fluxometria por Laser-Doppler/instrumentação , Masculino , Linhagem , Valor Preditivo dos Testes , Fluxo Pulsátil , Valores de Referência , Transdutores/veterinária
4.
J Am Anim Hosp Assoc ; 42(4): 249-61, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16822763

RESUMO

Seventy-six dogs with clinical acquired atrioventricular valvular disease were evaluated to determine the efficacy of pimobendan (n=41) versus benazepril hydrochloride (n=35) in a randomized, positive-controlled, multicenter study. The study was divided into 56-day and long-term evaluation periods. In a subgroup of dogs with concurrent furosemide treatment (pimobendan [n=31], benazepril [n=25]), the Heart Insufficiency Score improved in favor of pimobendan (P=0.0011), equating to a superior overall efficacy rating (P<0.0001) at day 56. Long-term median survival (i.e., death or treatment failure) for dogs receiving pimobendan was 415 days versus 128 days for dogs not on pimobendan (P=0.0022).


Assuntos
Benzazepinas/uso terapêutico , Cardiotônicos/uso terapêutico , Doenças do Cão/tratamento farmacológico , Doenças das Valvas Cardíacas/veterinária , Piridazinas/uso terapêutico , Animais , Doenças do Cão/mortalidade , Cães , Feminino , Doenças das Valvas Cardíacas/tratamento farmacológico , Doenças das Valvas Cardíacas/mortalidade , Masculino , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
5.
J Vet Intern Med ; 20(2): 277-83, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16594583

RESUMO

Cardiac troponin I (cTnI) and T (cTnT) have a high sequence homology across phyla and are sensitive and specific markers of myocardial damage. The purpose of this study was to evaluate the Cardiac Reader, a human point-of-care system for the determination of cTnT and myoglobin, and the Abbott Axsym System for the determination of cTnI and creatine kinase isoenzyme MB (CK-MB) in healthy dogs and in dogs at risk for acute myocardial damage because of gastric dilatation-volvulus (GDV) and blunt chest trauma (BCT). In healthy dogs (n = 56), cTnI was below detection limits (<0.1 microg/L) in 35 of 56 dogs (reference range 0-0.7 microg/L), and cTnT was not measurable (<0.05 ng/mL) in all but 1 dog. At presentation, cTnI, CK-MB, myoglobin, and lactic acid were all significantly higher in dogs with GDV (n = 28) and BCT (n = 8) than in control dogs (P < .001), but cTnT was significantly higher only in dogs with BCT (P = .033). Increased cTnI or cTnT values were found in 26 of 28 (highest values 1.1-369 microg/L) and 16 of 28 dogs (0.1-1.7 ng/mL) with GDV, and in 6 of 8 (2.3-82.4 microg/L) and 3 of 8 dogs (0.1-0.29 ng/mL) with BCT, respectively. In dogs suffering from GDV, cTnI and cTnT increased further within the first 48 hours (P < .001). Increased cardiac troponins suggestive of myocardial damage occurred in 93% of dogs with GDV and 75% with BCT. cTnI appeared more sensitive, but cTnT may be a negative prognostic indicator in GDV. Both systems tested seemed applicable for the measurement of canine cardiac troponins, with the Cardiac Reader particularly suitable for use in emergency settings.


Assuntos
Doenças do Cão/diagnóstico , Cardiopatias/veterinária , Kit de Reagentes para Diagnóstico/veterinária , Troponina C/sangue , Troponina I/sangue , Animais , Biomarcadores , Doenças do Cão/sangue , Cães , Feminino , Dilatação Gástrica/veterinária , Cardiopatias/sangue , Cardiopatias/diagnóstico , Masculino , Mioglobina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Fatores de Risco , Volvo Gástrico/veterinária , Ferimentos não Penetrantes/veterinária
8.
J Vet Intern Med ; 18(3): 311-21, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15188817

RESUMO

Indices for M-mode measurements in dogs usually have been based on the assumption that a linear relationship exists between these measurements and body weight (BW) or body surface area (BSA). The relationships between the geometry of 3-dimensional objects do not support this assumption. The purposes of this study were to retrospectively examine M-mode data from a large number of dogs of varying sizes and breeds that were examined by a large number of ultrasonographers, to use the allometric equation to determine the appropriate BW exponent required to predict these cardiac dimensions, and to determine normal mean values and prediction intervals for common M-mode variables. Linear regression analyses of data from 494 dogs (2.2-95 kg) revealed a good correlation between M-mode measurements and BW after logarithmic transformation of the data (r2 = .55-.88). Most variables were most closely related to an index of body length, BW(1/3), although the exponent that best predicted diastolic and systolic left ventricular wall thicknesses was closer to 0.25. No variable indexed well to BW or BSA. With these data, appropriate mean values and prediction intervals were calculated for normal dogs, allowing veterinarians to correctly and appropriately index M-mode values. The equations developed from this study appear to be applicable to adult dogs of most breeds.


Assuntos
Cães/fisiologia , Ecocardiografia/veterinária , Coração/fisiologia , Modelos Cardiovasculares , Animais , Feminino , Masculino , Linhagem , Valores de Referência , Estudos Retrospectivos
10.
J Vet Cardiol ; 6(1): 7-13, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-19083299

RESUMO

OBJECTIVES: To test the tolerability of long-term administration of benazepril in dogs with congestive heart failure (CHF). METHODS: The study was a prospective, randomized, double-blinded, placebo-controlled clinical trial. A total of 162 dogs with New York Heart Association (NYHA) class II-IV heart failure caused by chronic valvular disease (CVD) or dilated cardiomyopathy (DCM) were enrolled. Benazepril (minimum dosage, 0.25 mg/kg) or placebo were administered orally once daily for up to 34 months. In this paper, we report results of plasma alanine aminotransferase (ALT), creatinine, potassium and urea. RESULTS: The two groups were matched at baseline (p>/=0.18). Plasma creatinine concentrations were lower during treatment with benazepril versus placebo for all dogs (p=0.14) and every sub-group tested (NYHA II, III or IV; CVD; DCM; initial creatinine >124 mumol/L), although statistical significance was not reached (p=0.14-0.6). However, significantly (p=0.035) more cases of creatinine >124 mumol/L during treatment occurred with placebo (47%) as compared to benazepril (30%). Plasma ALT and urea values did not differ between groups for all dogs (p>0.5) or any sub-group (p=0.23-1.0). Plasma potassium values did not differ between groups for all dogs (p>0.5). Although differences approached statistical significance for potassium in some sub-groups (p=0.07-0.1), there were no consistent differences between groups. CONCLUSIONS: Benazepril was well tolerated during long-term therapy in dogs with CHF and no specific precautions appear to be necessary regarding plasma ALT, creatinine, potassium or urea. The possible action of benazepril in improving renal function (evidenced via lower plasma creatinine) merits further investigation.

11.