Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Air Waste Manag Assoc ; 73(4): 295-312, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36716322

RESUMO

Particulate matter (PM) is a major primary pollutant emitted during wildland fires that has the potential to pose significant health risks to individuals/communities who live and work in areas impacted by smoke events. Limiting exposure is the principle measure available to mitigate health impacts of smoke and therefore the accurate determination of ambient PM concentrations during wildland fire events is critical to protecting public health. However, monitoring air pollutants in smoke impacted environments has proven challenging in that measurement interferences or sampling conditions can result in both positive and negative artifacts. The EPA has performed research on methods for the measurement of PM2.5 in a series of laboratory-based studies including evaluation in smoke. This manuscript will summarize the results of the laboratory-based evaluation of federal equivalent method (FEM) monitors for PM2.5 with particular attention being given to the Teledyne-API Model T640 PM Mass monitor, as compared to the filter-based federal reference method (FRM). The T640 is an optical-based PM monitor and has been gaining wide use by state and local agencies in monitoring for PM2.5 U.S. National Ambient Air Quality Standards (NAAQS) attainment. At present, the T640 (includes both T640 and T640×) comprises ~44% of the PM2.5 FEM monitors in U.S. regulatory monitoring networks. In addition, the T640 has increasingly been employed for the higher time resolution comparison/evaluation of low-cost PM sensors including during smoke impacted events. Results from controlled non-smoke laboratory studies using generated ammonium sulfate aerosols demonstrated a generally negative T640 measurement artifact that was significantly related to the PM2.5 concentration and particle size distribution. Results from biomass burning chamber studies demonstrated positive and negative artifacts significantly associated with PM2.5 concentration and optical wavelength-dependent absorption properties of the smoke aerosol.Implications: The results detailed in this paper will provide state and local air monitoring agencies with the tools and knowledge to address PM2.5 measurement challenges in areas frequently impacted by wildland fire smoke. The observed large positive and negative artifacts in the T640 PM mass determination have the potential to result in false exceedances of the PM2.5 NAAQS or in the disqualification of monitoring data through an exceptional event designation. In addition, the observed artifacts in smoke impacted air will have a detrimental effect on providing reliable public information when wildfires occur and also in identifying reference measurements for small sensor evaluation studies. Other PM2.5 FEMs such as the BAM-1022 perform better in smoke and are comparable to the filter-based FRM. Care must be taken in choosing high time resolution FEM monitors that will be operated at smoke impacted sites. Accurate methods, such as the FRM and BAM-1022 will reduce the burden of developing and reviewing exceptional event request packages, data loss/disqualification, and provide states with tools to adequately evaluate public exposure risks and provide accurate public health messaging during wildfire/smoke events.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Humanos , Material Particulado/análise , Fumaça/análise , Sulfato de Amônio , Artefatos , Biomassa , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Aerossóis , Monitoramento Ambiental/métodos
2.
Atmosphere (Basel) ; 13(6): 1-22, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-36926184

RESUMO

Cairpol and Aeroqual air quality sensors measuring CO, CO2, NO2, and other species were tested in fresh biomass burning plumes in field and laboratory environments. We evaluated sensors by comparing 1-minute sensor measurements to collocated reference instrument measurements. Sensors were evaluated based on the coefficient of determination (r 2) between the sensor and reference measurements, by the accuracy, collocated precision, root mean square error (RMSE), and other metrics. In general, CO and CO2 sensors performed well (in terms of accuracy and r 2 values) compared to NO2 sensors. Cairpol CO and NO2 sensors had better sensor-versus-sensor agreement (e.g., collocated precision) than Aeroqual CO and NO2 sensors of the same species. Tests of other sensors (e.g., NH3, H2S, VOC, NMHC) provided more inconsistent results and need further study. Aeroqual NO2 sensors had an apparent O3 interference that was not observed in the Cairpol NO2 sensors. Although the sensor accuracy lags that of reference-level monitors, with location-specific calibrations they have the potential to provide useful data about community air quality and personal exposure to smoke impacts.

3.
Atmos Environ X ; 16: 1-17, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36960321

RESUMO

Wildland fires are a major source of gases and aerosols, and the production, dispersion, and transformation of fire emissions have significant ambient air quality impacts and climate interactions. The increase in wildfire area burned and severity across the United States and Canada in recent decades has led to increased interest in expanding the use of prescribed fires as a forest management tool. While the primary goal of prescribed fire use is to limit the loss of life and property and ecosystem damage by constraining the growth and severity of future wildfires, a potential additional benefit of prescribed fire - reduction in the adverse impacts of smoke production and greenhouse gas (GHG) emissions - has recently gained the interest of land management agencies and policy makers in the United States and other nations. The evaluation of prescribed fire/wildfire scenarios and the potential mitigation of adverse impacts on air quality and GHGs requires fuel layer specific pollutant emission factors (EFs) for fire prone forest ecosystems. Our study addresses this need with laboratory experiments measuring EFs for carbon dioxide (CO2), carbon monoxide (CO), methane (CH4), ethyne (C2H2), formaldehyde (H2CO), formic acid (CH2O2), hydrogen cyanide (HCN), fine particulate matter (PM2.5), nitric oxide (NO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and total reduced sulfur (TRS) for the burning of individual fuel components from three forest ecosystems which account for a large share of wildfire burned area and emissions in the western United States and Canada - Douglas fir, ponderosa pine, and black spruce/jack pine.

4.
Elementa (Wash D C) ; 9(1): 1-27, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34926709

RESUMO

The Korea-United States Air Quality (KORUS-AQ) field study was conducted during May-June 2016. The effort was jointly sponsored by the National Institute of Environmental Research of South Korea and the National Aeronautics and Space Administration of the United States. KORUS-AQ offered an unprecedented, multi-perspective view of air quality conditions in South Korea by employing observations from three aircraft, an extensive ground-based network, and three ships along with an array of air quality forecast models. Information gathered during the study is contributing to an improved understanding of the factors controlling air quality in South Korea. The study also provided a valuable test bed for future air quality-observing strategies involving geostationary satellite instruments being launched by both countries to examine air quality throughout the day over Asia and North America. This article presents details on the KORUS-AQ observational assets, study execution, data products, and air quality conditions observed during the study. High-level findings from companion papers in this special issue are also summarized and discussed in relation to the factors controlling fine particle and ozone pollution, current emissions and source apportionment, and expectations for the role of satellite observations in the future. Resulting policy recommendations and advice regarding plans going forward are summarized. These results provide an important update to early feedback previously provided in a Rapid Science Synthesis Report produced for South Korean policy makers in 2017 and form the basis for the Final Science Synthesis Report delivered in 2020.

5.
Atmos Meas Tech ; 14(3): 1783-1800, 2021 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-34017362

RESUMO

In recent years wildland fires in the United States have had significant impacts on local and regional air quality and negative human health outcomes. Although the primary health concerns from wildland fires come from fine particulate matter (PM2.5), large increases in ozone (O3) have been observed downwind of wildland fire plumes (DeBell et al., 2004; Bytnerowicz et al., 2010; Preisler et al., 2010; Jaffe et al., 2012; Bytnerowicz et al., 2013; Jaffe et al., 2013; Lu et al., 2016; Lindaas et al., 2017; McClure and Jaffe, 2018; Liu et al., 2018; Baylon et al., 2018; Buysse et al., 2019). Conditions generated in and around wildland fire plumes, including the presence of interfering chemical species, can make the accurate measurement of O3 concentrations using the ultraviolet (UV) photometric method challenging if not impossible. UV photometric method instruments are prone to interferences by volatile organic compounds (VOCs) that are present at high concentrations in wildland fire smoke. Four different O3 measurement methodologies were deployed in a mobile sampling platform downwind of active prescribed grassland fire lines in Kansas and Oregon and during controlled chamber burns at the United States Forest Service, Rocky Mountain Research Station Fire Sciences Laboratory in Missoula, Montana. We demonstrate that the Federal Reference Method (FRM) nitric oxide (NO) chemiluminescence monitors and Federal Equivalent Method (FEM) gas-phase (NO) chemical scrubber UV photometric O3 monitors are relatively interference-free, even in near-field combustion plumes. In contrast, FEM UV photometric O3 monitors using solid-phase catalytic scrubbers show positive artifacts that are positively correlated with carbon monoxide (CO) and total gas-phase hydrocarbon (THC), two indicator species of biomass burning. Of the two catalytic scrubber UV photometric methods evaluated, the instruments that included a Nafion® tube dryer in the sample introduction system had artifacts an order of magnitude smaller than the instrument with no humidity correction. We hypothesize that Nafion®-permeating VOCs (such as aromatic hydrocarbons) could be a significant source of interference for catalytic scrubber UV photometric O3 monitors and that the inclusion of a Nafion® tube dryer assists with the mitigation of these interferences. The chemiluminescence FRM method is highly recommended for accurate measurements of O3 in wildland fire plume studies and at regulatory ambient monitoring sites frequently impacted by wildland fire smoke.

6.
Artigo em Inglês | MEDLINE | ID: mdl-33889052

RESUMO

Wildland fires can emit substantial amounts of air pollution that may pose a risk to those in proximity (e.g., first responders, nearby residents) as well as downwind populations. Quickly deploying air pollution measurement capabilities in response to incidents has been limited to date by the cost, complexity of implementation, and measurement accuracy. Emerging technologies including miniaturized direct-reading sensors, compact microprocessors, and wireless data communications provide new opportunities to detect air pollution in real time. The U.S. Environmental Protection Agency (EPA) partnered with other U.S. federal agencies (CDC, NASA, NPS, NOAA, USFS) to sponsor the Wildland Fire Sensor Challenge. EPA and partnering organizations share the desire to advance wildland fire air measurement technology to be easier to deploy, suitable to use for high concentration events, and durable to withstand difficult field conditions, with the ability to report high time resolution data continuously and wirelessly. The Wildland Fire Sensor Challenge encouraged innovation worldwide to develop sensor prototypes capable of measuring fine particulate matter (PM2.5), carbon monoxide (CO), carbon dioxide (CO2), and ozone (O3) during wildfire episodes. The importance of using federal reference method (FRM) versus federal equivalent method (FEM) instruments to evaluate performance in biomass smoke is discussed. Ten solvers from three countries submitted sensor systems for evaluation as part of the challenge. The sensor evaluation results including sensor accuracy, precision, linearity, and operability are presented and discussed, and three challenge winners are announced. Raw solver submitted PM2.5 sensor accuracies of the winners ranged from ~22 to 32%, while smoke specific EPA regression calibrations improved the accuracies to ~75-83% demonstrating the potential of these systems in providing reasonable accuracies over conditions that are typical during wildland fire events.

7.
J Air Waste Manag Assoc ; 71(7): 866-889, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33689601

RESUMO

The Lake Michigan Ozone Study 2017 (LMOS 2017) in May and June 2017 enabled study of transport, emissions, and chemical evolution related to ozone air pollution in the Lake Michigan airshed. Two highly instrumented ground sampling sites were part of a wider sampling strategy of aircraft, shipborne, and ground-based mobile sampling. The Zion, Illinois site (on the coast of Lake Michigan, 67 km north of Chicago) was selected to sample higher NOx air parcels having undergone less photochemical processing. The Sheboygan, Wisconsin site (on the coast of Lake Michigan, 211 km north of Chicago) was selected due to its favorable location for the observation of photochemically aged plumes during ozone episodes involving southerly winds with lake breeze. The study encountered elevated ozone during three multiday periods. Daytime ozone episode concentrations at Zion were 60 ppb for ozone, 3.8 ppb for NOx, 1.2 ppb for nitric acid, and 8.2 µg m-3 for fine particulate matter. At Sheboygan daytime, ozone episode concentrations were 60 ppb for ozone, 2.6 ppb for NOx, and 3.0 ppb for NOy. To facilitate informed use of the LMOS 2017 data repository, we here present comprehensive site description, including airmass influences during high ozone periods of the campaign, overview of meteorological and pollutant measurements, analysis of continuous emission monitor data from nearby large point sources, and characterization of local source impacts from vehicle traffic, large point sources, and rail. Consistent with previous field campaigns and the conceptual model of ozone episodes in the area, trajectories from the southwest, south, and lake breeze trajectories (south or southeast) were overrepresented during pollution episodes. Local source impacts from vehicle traffic, large point sources, and rail were assessed and found to represent less than about 15% of typical concentrations measured. Implications for model-observation comparison and design of future field campaigns are discussed.Implications: The Lake Michigan Ozone Study 2017 (LMOS 2017) was conducted along the western shore of Lake Michigan, and involved two well-instrumented coastal ground sites (Zion, IL, and Sheboygan, WI). LMOS 2017 data are publicly available, and this paper provides detailed site characterization and measurement summary to enable informed use of repository data. Minor local source impacts were detected but were largely confined to nighttime conditions of less interest for ozone episode analysis and modeling. The role of these sites in the wider field campaign and their detailed description facilitates future campaign planning, informed data repository use, and model-observation comparison.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Ozônio , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Monitoramento Ambiental , Lagos , Meteorologia , Michigan , Ozônio/análise
8.
Bull Am Meteorol Soc ; 102(12): E2207-E2225, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35837596

RESUMO

The Lake Michigan Ozone Study 2017 (LMOS 2017) was a collaborative multiagency field study targeting ozone chemistry, meteorology, and air quality observations in the southern Lake Michigan area. The primary objective of LMOS 2017 was to provide measurements to improve air quality modeling of the complex meteorological and chemical environment in the region. LMOS 2017 science questions included spatiotemporal assessment of nitrogen oxides (NO x = NO + NO2) and volatile organic compounds (VOC) emission sources and their influence on ozone episodes; the role of lake breezes; contribution of new remote sensing tools such as GeoTASO, Pandora, and TEMPO to air quality management; and evaluation of photochemical grid models. The observing strategy included GeoTASO on board the NASA UC-12 aircraft capturing NO2 and formaldehyde columns, an in situ profiling aircraft, two ground-based coastal enhanced monitoring locations, continuous NO2 columns from coastal Pandora instruments, and an instrumented research vessel. Local photochemical ozone production was observed on 2 June, 9-12 June, and 14-16 June, providing insights on the processes relevant to state and federal air quality management. The LMOS 2017 aircraft mapped significant spatial and temporal variation of NO2 emissions as well as polluted layers with rapid ozone formation occurring in a shallow layer near the Lake Michigan surface. Meteorological characteristics of the lake breeze were observed in detail and measurements of ozone, NOx, nitric acid, hydrogen peroxide, VOC, oxygenated VOC (OVOC), and fine particulate matter (PM2.5) composition were conducted. This article summarizes the study design, directs readers to the campaign data repository, and presents a summary of findings.

9.
Atmos Chem Phys ; 21(14): 11133-11160, 2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35949546

RESUMO

Nitrogen oxides (NO x =NO+NO2) play a crucial role in the formation of ozone and secondary inorganic and organic aerosols, thus affecting human health, global radiation budget, and climate. The diurnal and spatial variations in NO2 are functions of emissions, advection, deposition, vertical mixing, and chemistry. Their observations, therefore, provide useful constraints in our understanding of these factors. We employ a Regional chEmical and trAnsport model (REAM) to analyze the observed temporal (diurnal cycles) and spatial distributions of NO2 concentrations and tropospheric vertical column densities (TVCDs) using aircraft in situ measurements and surface EPA Air Quality System (AQS) observations as well as the measurements of TVCDs by satellite instruments (OMI: the Ozone Monitoring Instrument; GOME-2A: Global Ozone Monitoring Experiment - 2A), ground-based Pandora, and the Airborne Compact Atmospheric Mapper (ACAM) instrument in July 2011 during the DISCOVER-AQ campaign over the Baltimore-Washington region. The model simulations at 36 and 4 km resolutions are in reasonably good agreement with the regional mean temporospatial NO2 observations in the daytime. However, we find significant overestimations (underestimations) of model-simulated NO2 (O3) surface concentrations during night-time, which can be mitigated by enhancing nocturnal vertical mixing in the model. Another discrepancy is that Pandora-measured NO2 TVCDs show much less variation in the late afternoon than simulated in the model. The higher-resolution 4 km simulations tend to show larger biases compared to the observations due largely to the larger spatial variations in NO x emissions in the model when the model spatial resolution is increased from 36 to 4 km. OMI, GOME-2A, and the high-resolution aircraft ACAM observations show a more dispersed distribution of NO2 vertical column densities (VCDs) and lower VCDs in urban regions than corresponding 36 and 4 km model simulations, likely reflecting the spatial distribution bias of NO x emissions in the National Emissions Inventory (NEI) 2011.

10.
Sensors (Basel) ; 16(10)2016 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-27754370

RESUMO

This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in Houston, Texas and Denver, Colorado, under the umbrella of the NASA-led DISCOVER-AQ Earth Venture Mission. Measurements were focused on ozone (O3) and nitrogen dioxide (NO2). The performance evaluation showed that the CairClip O3/NO2 sensor provided a consistent measurement response to that of reference monitors (r² = 0.79 in Houston; r² = 0.72 in Denver) whereas the CairClip NO2 sensor measurements showed no agreement to reference measurements. The CairClip O3/NO2 sensor data from the citizen science sites compared favorably to measurements at nearby reference monitoring sites. This study provides important information on data quality from low-cost sensor technologies and is one of few studies that reports sensor data collected directly by citizen scientists.

11.
J Air Waste Manag Assoc ; 58(1): 65-71, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18236795

RESUMO

The Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) has been previously verified as being capable of measuring total fine particulate matter (PM2.5), including semi-volatile species. The present study was conducted to determine if the simple modification of a commercial speciation sampler with a charcoal denuder followed by a filter pack containing a quartz filter and a charcoal-impregnated glass (CIG) fiber filter would allow for the measurement of total PM2.5, including semi-volatile organic material. Data were collected using an R&P (Rupprecht and Pastasnik Co., Inc.) Partisol Model 2300 speciation sampler; an R&P Partisol speciation sampler modified with a BOSS denuder, followed by a filter pack with a quartz and a CIG filter; a Met One spiral aerosol speciation sampler (SASS); and the PC-BOSS from November 2001 to March 2002 at a U.S. Environmental Protection Agency (EPA) Science to Achieve Results (STAR) sampling site in Lindon, UT. Total PM2.5 mass, ammonium nitrate (both nonvolatile and semi-volatile), ammonium sulfate, organic carbon (both non-volatile and semi-volatile), and elemental carbon were determined on a 24-hr basis. Results obtained with the individual samplers were compared to determine the capability of the modified R&P speciation sampler for measuring total PM2.5, including semi-volatile components. Data obtained with the modified speciation sampler agreed with the PC-BOSS results. Data obtained with the two unmodified speciation samplers were low by an average of 26% because of the loss of semi-volatile organic material from the quartz filter during sample collection.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Compostos Orgânicos/análise , Material Particulado/análise , Poluentes Atmosféricos/química , Carbono/análise , Carvão Vegetal , Filtração/instrumentação , Filtração/métodos , Compostos Orgânicos/química , Material Particulado/química , Quartzo , Estações do Ano , Sulfatos/análise , Utah , Volatilização
12.
J Air Waste Manag Assoc ; 56(4): 384-97, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16681204

RESUMO

Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/análise , Monitoramento Ambiental/métodos , Poluentes Ocupacionais do Ar/química , Filtração , Padrões de Referência , Reprodutibilidade dos Testes , Estações do Ano , Estados Unidos , Volatilização
13.
J Air Waste Manag Assoc ; 56(3): 294-305, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16573192

RESUMO

Studies conducted at the U.S. Environmental Protection Agency facility in Research Triangle Park, NC, and at a field study in Southern California have demonstrated the capability for the semicontinuous determination of particulate nitrate (and other water-soluble ionic species). Two instruments, an R&P Series 8400N Ambient Particulate Nitrate Monitor (8400N) and an ion chromatography (IC)-based prototype monitor developed at Texas Tech University, were evaluated both in the laboratory using aqueous standards and simulated ambient aerosols and in the field during a 3-week July 1-21, 2003) joint ambient comparison study with Brigham Young University and the South Coast Air Quality Management District (SCAQMD). The field study was conducted at the SCAQMD Rubidoux field site near Riverside, CA. During initial (before the field study) laboratory studies, both instruments were responsive to changes in the simulated aerosol concentration. However, potential problems were discovered involving both instruments during the laboratory-based studies both before and after the Rubidoux study, and these problems are currently being addressed. During the 3-week field study period, 15-minute average particulate nitrate concentrations approaching 30 microg/m3 were observed. Because of malfunctioning IC components (concentrator columns) of the Texas Tech University prototype monitor, limited data were obtained from this instrument during the 3-week sampling period. Initial ambient comparisons show general agreement between the 8400N and IC-based prototype instrument for the semicontinuous determination of ambient particulate nitrate at lower nitrate concentrations (<15 microg/m3) and an underdetermination by the 8400N at higher concentrations (>15 microg/m3). A decreased molybdenum converter efficiency in the pulse analyzer of the 8400N discovered during postfield study laboratory evaluation may explain the negative bias observed at higher nitrate concentrations. Semicontinuous results obtained from U.S. Environmental Protection Agency-operated instruments were averaged and compared with integrated sampler results obtained by Brigham Young University and SCAQMD.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Nitratos/análise , Aerossóis/análise , California , Poeira , Monitoramento Ambiental/métodos , Tamanho da Partícula , Projetos Piloto , Reprodutibilidade dos Testes
14.
J Air Waste Manag Assoc ; 55(12): 1839-46, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16408688

RESUMO

Fine particulate matter (PM2.5) mass was determined on a continuous basis at the Salt Lake City Environmental Protection Agency Environmental Monitoring for Public Awareness and Community Tracking monitoring site in Salt Lake City, UT, using three different monitoring techniques. Hourly averaged PM2.5 mass data were collected during two sampling periods (summer 2000 and winter 2002) using a real-time total ambient mass sampler (RAMS), sample equilibration system (SES)-tapered element oscillating microbalance (TEOM), and conventional TEOM monitor. This paper compares the results obtained from the various monitoring systems, which differ in their treatment of semivolatile material (SVM; particle-bound water, semivolatile ammonium nitrate, and semivolatile organic compounds). PM2.5 mass results obtained by the RAMS were consistently higher than those obtained by the SES-TEOM and conventional TEOM monitors because of the RAMS ability to measure semivolatile ammonium nitrate and semivolatile organic material but not particle-bound water. The SES-TEOM monitoring system was able to account for an average of 28% of the SVM, whereas the conventional TEOM monitor loses essentially all of the SVM from the single filter during sampling. Occasional mass readings by the various TEOM monitors that are higher than RAMS results may reflect particle-bound water, which, under some conditions, is measured by the TEOM but not the RAMS.


Assuntos
Poluentes Atmosféricos/análise , Poeira/análise , Monitoramento Ambiental/métodos , Cidades , Monitoramento Ambiental/instrumentação , Fatores de Tempo , Utah , Volatilização
15.
Environ Health Perspect ; 112(3): 339-45, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-14998750

RESUMO

Epidemiologic studies report associations between particulate air pollution and cardiopulmonary morbidity and mortality. Although the underlying pathophysiologic mechanisms remain unclear, it has been hypothesized that altered autonomic function and pulmonary/systemic inflammation may play a role. In this study we explored the effects of air pollution on autonomic function measured by changes in heart rate variability (HRV) and blood markers of inflammation in a panel of 88 elderly subjects from three communities along the Wasatch Front in Utah. Subjects participated in multiple sessions of 24-hr ambulatory electrocardiographic monitoring and blood tests. Regression analysis was used to evaluate associations between fine particulate matter [aerodynamic diameter less than or equal to 2.5 microm (PM2.5)] and HRV, C-reactive protein (CRP), blood cell counts, and whole blood viscosity. A 100- microg/m3 increase in PM2.5 was associated with approximately a 35 (SE = 8)-msec decline in standard deviation of all normal R-R intervals (SDNN, a measure of overall HRV); a 42 (SE = 11)-msec decline in square root of the mean of the squared differences between adjacent normal R-R intervals (r-MSSD, an estimate of short-term components of HRV); and a 0.81 (SE = 0.17)-mg/dL increase in CRP. The PM2.5-HRV associations were reasonably consistent and statistically robust, but the CRP association dropped to 0.19 (SE = 0.10) after excluding the most influential subject. PM2.5 was not significantly associated with white or red blood cell counts, platelets, or whole-blood viscosity. Most short-term variability in temporal deviations of HRV and CRP was not explained by PM2.5; however, the small statistically significant associations that were observed suggest that exposure to PM2.5 may be one of multiple factors that influence HRV and CRP.


Assuntos
Envelhecimento , Poluentes Atmosféricos/intoxicação , Exposição Ambiental , Frequência Cardíaca , Inflamação , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Contagem de Células Sanguíneas , Proteína C-Reativa/análise , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho da Partícula , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...