Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Med Sci ; 38(1): 78-84, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30074155

RESUMO

In the present study, we aimed at exploring the applied value of preoperative neutrophil lymphocyte ratio (NLR) and platelet lymphocyte ratio (PLR) in the prediction of lymph node metastasis (LNM) and prognosis in patients with early gastric cancer (EGC). We retrospectively analyzed a total of248 consecutive patients who underwent curative gastrectomy to be identified T1 stage gastric adenocarcinoma between January 1, 2010 and May 1, 2016 in a single institution. According to median preoperative NLR and PLR value, we divided the patients into four groups: high NLR >1.73 and low NLR <1.73, high PLR >117.78 and low PLR <117.78. Furthermore, to evaluate the relationship between preoperative NLR and PLR values, we categorized patients according to cutoff preoperative NLR-PLR score of 2 [high NLR (>1.73) and high PLR (>117.78)], 1 [either high NLR or high PLR], and 0 [neither high NLR nor high PLR], Statistical analyses were conducted using SPSS 20.0 software. The results showed that the preoperative NLR or PLR values, lower or higher, could not predict the LNM in patients with EGC (both P=0.544>0.05). The invasive depth of tumor was significantly correlated with LNM of EGC (P0.001). Kaplan-Meier plots illustrated that preoperative NLR and PLR values were not associated with overall survival (OS) in patients with EGC. It was concluded that the preoperative NLR and PLR may be the predictors for LNM and prognosis in patients with advanced gastric cancer; nevertheless, they cannot predict LNM and prognosis in patients with EGC.


Assuntos
Adenocarcinoma/sangue , Biomarcadores Tumorais/sangue , Neoplasias Gástricas/sangue , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Metástase Linfática , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Neutrófilos/citologia , Contagem de Plaquetas , Período Pré-Operatório , Prognóstico , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia
2.
J Huazhong Univ Sci Technolog Med Sci ; 36(6): 865-870, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27924502

RESUMO

The study aimed to examine the applicability of carbon nanoparticles as a tracer for lymph node mapping and the related factors of lymph node and No.8p subgroup metastasis in patients with gastric cancer. Clinical data of 50 patients with gastric cancer, who had not received treatment preoperatively and underwent gastrectomy in Department of Gastrointestinal Surgery, Wuhan Union Hospital, between October 2014 and August 2015, were retrospectively analyzed. These patients were found to have no distant metastasis preoperatively. Thirty-five out of 50 patients were subjected to lymphatic mapping technique using carbon nanoparticles as the tracer, and the rest 15 cases did not experience the lymphatic mapping and served as controls. The sensitivity, specificity, false positive rate and false negative rate were calculated according to the number of lymph nodes, and the staining and metastasis condition of lymph nodes. The diagnostic value of carbon nanoparticles on metastatic lymph nodes was evaluated. The relationship between the metastasis of lymph nodes or subgroup No.8p lymph nodes and clinicopathologic features was analyzed by χ2-test or Fisher's exact test. All patients underwent D2 surgery (lymph node dissection including all the group 1 and group 2 nodes) plus the dissection of the subgroup No.8p lymph nodes. It was found that the average number of harvested lymph nodes in lymphatic mapping technique group (45.7±14.5) was greater than that in control group (39.2±11.7), but the difference was not significantly different (P=0.138>0.05). The success rate, the accuracy, sensitivity, specificity and false negative rate was 97%, 57%, 28%, 62% and 72% respectively. The metastasis of lymph nodes was correlated to the depth of cancer invasion (T stage) (P=0.004<0.05), and the metastasis of No.8p lymph nodes was correlated to the extent of lymph node involvement (N stage) (P=0.007<0.05). Six cases had lymph node metastasis in subgroup No.8p, and their TNM stages and clinical stages were as follows: T1N2M0 IIA, T3N3M0 IIIB, T4aN3M0 IIIC, T4aN3M0 IIIC, T4aN3M0 IIIC, and T4bN3M0 IIIC. In conclusion, our study indicated that carbon nanoparticles failed to show good selectivity for metastatic lymph nodes; the result of lymphatic mapping does not achieve a satisfactory performance; the incidence of lymph node metastasis may increase, accompanying with the increase of the depth of cancer invasion; No.8p lymph node metastasis tends to occur for gastric carcinoma patients with the extent of lymph node metastasis over N2 stage.


Assuntos
Carcinoma/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Nanopartículas/efeitos adversos , Neoplasias Gástricas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Carbono , Carcinoma/patologia , Carcinoma/cirurgia , Feminino , Humanos , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Nanopartículas/administração & dosagem , Nanopartículas/química , Sensibilidade e Especificidade , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia
3.
Medicine (Baltimore) ; 95(5): e2129, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26844449

RESUMO

This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.


Assuntos
Neoplasias Colorretais/diagnóstico , DNA/análise , Fezes/química , Genes Neoplásicos , Programas de Rastreamento/métodos , Humanos , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...