Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale ; 16(1): 205-211, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38051125

RESUMO

Atomically precise metal nanoclusters are promising candidates for various biomedical applications, including their use as photosensitizers in photodynamic therapy (PDT). However, typical synthetic routes of clusters often result in complex mixtures, where isolating and characterizing pure samples becomes challenging. In this work, a new Au22(Lys-Cys-Lys)16 cluster is synthesized using photochemistry, followed by a new type of light activated, accelerated size-focusing. Fluorescence excitation-emission matrix spectroscopy (EEM) and parallel factor (PARAFAC) analysis have been applied to track the formation of fluorescent species, and to assess optical purity of the final product. Furthermore, excited state reactivity of Au22(Lys-Cys-Lys)16 clusters is studied, and formation of type-I reactive oxygen species (ROS) from the excited state of the clusters is observed. The proposed size-focusing procedure in this work can be easily adapted to conventional cluster synthetic methods, such as borohydride reduction, to provide atomically precise clusters.

2.
Anal Chem ; 95(34): 12631-12639, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37590886

RESUMO

We present a 4-dimensional (4D) fluorescence imaging system in which each of the 65,536 pixels in the image array contains an excitation-emission-matrix spectrum with 31 excitation wavelengths and 8 emission wavelengths (x, y, λexc, λem). Hadamard-transform multiplexing of the excitation light from a 31-channel programmable light source allows for an increase in the data acquisition rate so that each 65,536-pixel image can be obtained within 8 s. The system is demonstrated and characterized using, first, a 4D image of 10 capillaries filled with four dye solutions and their binary and ternary mixtures, and, second, using a sequence of about 100 images of layered fluorescent dye solutions and their changing fluorescence as a function of temperature. Multivariate analysis using parallel factor analysis produces images of the spatial distribution of the fluorophores together with their relative intensity as a function of time.

3.
Anal Chem ; 95(34): 12691-12700, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37582264

RESUMO

Hadamard-transform (HT) multiplexing has recently been applied to increasingly complex spectroscopic techniques. It had been shown that the data acquisition time for fluorescence excitation emission matrix (EEM) spectroscopy can be reduced by 1 or 2 orders of magnitude using HT multiplexing of the excitation light using a programmable light source. In these previous studies, the data acquisition rate had been limited by the time it took to record an EEM, that is, to complete one cycle of multiplexed excitation spectra. The extraction of chemical information, such as concentration and chemical identity, is then obtained from parallel factor (PARAFAC) analysis of the sequence of EEMs. In this contribution, we increase the data acquisition rate by another order of magnitude, limited ultimately by the time it takes to record a single excitation spectrum. Our algorithm is entirely based on improved data processing, that is, it can be applied to previously recorded HT multiplexed data sets. The algorithm is based on three previously unexplored approaches: (1) we perform a PARAFAC multivariate analysis on the raw (multiplexed) data set, (2) the time-independent PARAFAC loading vectors are obtained prior to obtaining the time-dependent score vectors, and (3) when loading vectors are difficult to obtain from the EEMs, we instead use a rolling-average approach to considerably increase the stability of the fit. Analysis of experimental data shows that the scores of fluorescence EEMs with seven excitation wavelengths and over 1000 emission wavelengths can be obtained in less than 20 ms.

4.
Anal Chem ; 93(23): 8116-8121, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34096269

RESUMO

We present a new rapid-acquisition HPLC detector based on a Hadamard-transform (HT) excitation-emission-matrix (EEM) fluorescence spectrometer allowing the acquisition of two-dimensional spectra at a rate faster than 6 spectra per second (<150 ms per spectrum). The instrument uses discrete ultraviolet light emitting diode (UV LED) light sources which are multiplexed using patterns derived from a Hadamard-matrix and affords faster spectral acquisition compared to conventional sequentially scanning EEM spectrometers. This new programmable light source was combined with a commercial fluorescence spectrometer and integrated as a detector into an HPLC system. We characterize the HT-EEM spectrometer by rapidly separating and detecting a mixture of five different coumarin dyes, with all five analytes eluting in under 2 min. A parallel factor analysis (PARAFAC) algorithm was able to readily separate and identify all coumarin fluorophores without any prior knowledge of the system, even decomposing two coeluting analytes into two distinct PARAFAC components. The HT-EEM spectrometer provides a novel and versatile detection technique suited for rapid online analysis and quantification of analytes in separation methods such as HPLC.


Assuntos
Corantes Fluorescentes , Cromatografia Líquida de Alta Pressão , Análise Fatorial , Fluorescência , Espectrometria de Fluorescência
5.
Analyst ; 146(9): 2834-2841, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33949440

RESUMO

We present a one-step fabrication method for a new multiplexed electrospray emitter with nine parallel micronozzles. The nozzles were formed by wet chemical etching of the end of a microstructured silica fiber containing nine 10 µm flow channels. By carefully adjusting the water flow through the channels while etching, we controlled the shape of the conical micronozzles and were able to obtain conditions under which the micronozzles, together with the flow channels, formed optical micro-axicon lenses. When 1064 nm light was guided through the flow channels and focused by the micro-axicon lenses into the Taylor cones, we were able to increase the desolvation of a model analyte and thereby increased the spray current produced by the emitter. This work paves the way towards a rapidly modulated mass-spectrometry source having a greatly enhanced throughput.

6.
Anal Chem ; 92(18): 12489-12497, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32808754

RESUMO

A novel Hadamard-transform excitation-emission matrix (EEM) spectrometer generates two-dimensional (2D) fluorescence matrices at a data acquisition rate of over 6 EEMs per minute and with a spectral resolution of 5.3 nm. Using Fresnel reflections from the sample cell, we could record optical transmission spectra synchronously with the 2D EEMs. The spectrometer was integrated into a custom-designed stopped-flow injection device to collect visible absorption and fluorescence EEM spectra of reacting solutions. Two different kinetic studies on two rapidly evolving chemical reactions with multiple overlapping spectral components were conducted by collecting over 8400 absorption spectra and EEMs. The third-order rate constant for the demetalation of chlorophyll-a to pheophytin-a was experimentally determined to be 450 ± 20 M-2·s-1 as derived from a parallel factor (PARAFAC) analysis where absorption and fluorescence data were combined. A PARAFAC analysis of data collected from the insertion of a copper atom into pheophytin-a resulted in several absorbing components and only a single fluorescing component. A reaction model with an association complex and a sitting-a-top (SAT) complex as intermediates explained the absorption data, resulting in a sequence of second-order reactions with rate constants of 4.0 ± 0.4, 2.7 ± 0.3, and 0.28 ± 0.02 M-1·s-1, respectively. The rate constant of the fluorescence decrease was determined to be 1.7 ± 0.2 M-1·s-1, which is consistent with the fluorescence component being attributed to both the pheophytin-a and the association complex.


Assuntos
Clorofila A/análise , Feofitinas/análise , Cinética , Espectrometria de Fluorescência , Spinacia oleracea/química
7.
Chem Commun (Camb) ; 56(8): 1275-1278, 2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-31903463

RESUMO

Microcontact printed patterns of N-heterocyclic carbenes (NHCs) and thiols were prepared on gold substrates and utilized as templates for the creation of metallic Cu structures using electroplating. The presence of the NHC in the pattern is essential to enable the transfer of the resulting copper microstructures to a second substrate.

8.
Soft Matter ; 14(12): 2206-2218, 2018 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-29431812

RESUMO

The response of polysiloxane materials to volatile organic compounds (VOCs) including benzene, toluene, ethylbenzene, and toluene (BTEX), as well as cyclohexane, acetone, methanol and isopropanol is studied using thin film large-angle refractometry. Refractive index and thickness changes are measured to quantify the diffusion rate and partition coefficients associated with the absorption and desorption of VOC vapours into polydimethylsiloxane (PDMS) and polydiphenylsiloxane (PDPS) - PDMS copolymer films. Absorption of volatile solvent vapours into siloxane polymers is found to follow two distinct mechanisms with different absorption rates. These mechanisms are also associated with different excess volumes of mixing and may be accompanied by a polymer restructuring step.

9.
IEEE Trans Biomed Eng ; 65(4): 921-927, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28749342

RESUMO

OBJECTIVE: A fiber optic vibration sensor is developed and characterized with an ultrawide dynamic sensing range, from less than 1 Hz to clinical ultrasound frequencies near 6 MHz. The vibration sensor consists of a matched pair of fiber Bragg gratings coupled to a custom-built signal processing circuit. The wavelength of a laser diode is locked to one of the many cavity resonances using the Pound-Drever-Hall scheme. METHODS: A calibrated piezoelectric vibration element was used to characterize the sensor's strain, temperature, and noise responses. To demonstrate its sensing capability, an ultrasound phantom with built-in low frequency vibration actuation was constructed. RESULTS: The fiber optic senor was shown to simultaneously capture the low frequency vibration and the clinical ultrasound transmission waveforms with nanostrain sensitivity. CONCLUSION: This miniaturized and sensitive vibration sensor can provide comprehensive information regarding strain response and the resultant ultrasound waveforms.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Vibração , Desenho de Equipamento , Modelos Biológicos
10.
Opt Express ; 24(18): 20346-58, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27607641

RESUMO

A facile method is presented for the fabrication of microlenses at the facet of fused silica capillaries and microstructured fibers. After submersion in hydrogen fluoride solution water is pumped slowly through the center hole of the capillary microchannel to create an etchant gradient extending from the capillary axis. The desired axicon angle is generated by adjusting the etching time and/or concentration of the etchant. Similarly, flow- assisted HF etching of a custom microstructured fiber containing nine microchannels produces nine individual microlenses simultaneously at the fiber facet, where each microaxicon lens shows a similar focusing pattern. A theoretical model of the flow-assisted etching process is used to determine the axicon angle and post angle. Also, a simple ray-based model was applied to characterize the focusing properties of the microaxicons in good agreement with experimental observations.

11.
Nanotechnology ; 27(42): 424004, 2016 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-27641834

RESUMO

Several mathematical models exist in the literature to describe the properties of optical resonators. Here, coupled mode theory and coherent superposition theory are compared and their consistency is demonstrated as they are applied to phase-shift cavity ring-down measurements in optical (micro-)cavities. In the particular case of a whispering gallery mode in a microsphere cavity these models are applied to transmission measurements and backscattering measurements through the fiber taper that couples light into the microresonator. It is shown that both models produce identical relations when applied to these traveling wave cavities.

12.
Opt Express ; 24(13): 14086-99, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410569

RESUMO

We describe an in-fiber interferometer based on a gas-filled hollow-core photonic crystal fiber. Expressions for the sensitivity, figure of merit and refractive index resolution are derived, and values are experimentally measured and theoretically validated using mode field calculations. The refractive indices of nine monoatomic and molecular gases are measured with a resolution of δns < 10-6.

13.
Appl Opt ; 55(4): 947-53, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26836105

RESUMO

Using a large-angle refractometer, the refractive indices of water, methanol, acetonitrile, acetone, ethanol, formaldehyde solution, 2-propanol, hexanes, 1-propanol, 2-butanol, tetrahydrofuran, dichloromethane, 1,4-dioxane, cyclohexane, N,N-dimethylformamide, ethylene glycol, N,N-dimethylacetamide, chloroform, glycerol, trichloroethylene, dimethylsulfoxide, p-xylene, ethylbenzene, toluene, m-xylene, benzene, and o-xylene were measured at 1550 nm and compared to literature values. In addition, the refractive indices of 48 aqueous sucrose solutions, 34 aqueous sodium chloride solutions, 40 DMSO-water, 40 ethylene glycol-water, and 40 glycerol-water mixtures were also measured at different concentrations and fit with third-order polynomial expressions. This study provides near-infrared refractive indices that were not previously available and may help with the calibration of refractive index sensors that operate at or near 1550 nm.

14.
Soft Matter ; 11(45): 8746-57, 2015 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26458138

RESUMO

The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitatively by the Lorentz-Lorenz equation and the Clausius-Mosotti equation. To validate the model, the uptake kinetics of water and other solvents into SU-8 films (d = 40-45 µm) were explored. Large-angle interferometric refractometry measurements can be used to characterize films that are between 15 µm to 150 µm thick and, Fourier analysis, is used to determine independently the thickness, the average refractive index and the refractive index at the film-substrate interface at one-second time intervals. From these values the mass fraction of water in SU-8 was calculated. The kinetics were best described by two independent uptake processes having different rates. Each process followed one-dimensional Fickian diffusion kinetics with diffusion coefficients for water into SU-8 photoresist film of 5.67 × 10(-9) cm(2) s(-1) and 61.2 × 10(-9) cm(2) s(-1).

15.
Opt Express ; 22(16): 19337-47, 2014 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-25321018

RESUMO

A fiber laser using a thulium-doped ZBLAN gain medium was used to generate laser radiation simultaneously at 1461, 1505 and 1874 nm, with > 5 mW output power at each of the wavelengths. The laser was used to quantify the near-infrared absorption of liquid water in acetone. Additionally, near-infrared spectra were recorded using a broad band source and were interpreted using parallel factor (PARAFAC) analysis to rationalize the concentration-dependent peak shifts.

16.
Appl Opt ; 53(13): 2917-23, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24921880

RESUMO

The inhomogeneity of high-reflectivity mirror coatings is a potential error source in the application of the cavity ringdown technique. Here, the ringdown times for different transverse modes were recorded. Together with the observed spatial distribution of these modes the ringdown times can be used to approximately locate the position of coating defects. A simple model based on a weighted sum of Hermite-Gaussian mode functions is used to explain the experimental results.

17.
Anal Chim Acta ; 811: 1-12, 2014 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-24456588

RESUMO

The fluorescence of antioxidant additives in lubricant oil was used as an indicator of oxidative stability of the oil. It was found that the decrease in fluorescence intensities of phenyl-α-napthylamine, its dimer, and another unidentified antioxidant coincide with the formation of decomposition products of the oil base stock. Simple kinetic models were developed that were capable of describing antioxidant reactions as a pseudo first-order processes. It is shown that fluorescence excitation emission matrix (EEM) spectroscopy coupled with an optical fiber probe can provide real-time assessment of the oxidative stability of the lubricant. Parallel factor (PARAFAC) analysis was used to correlate the component scores to the oil breakdown number.

18.
Anal Chem ; 85(9): 4328-34, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23480430

RESUMO

Short liquid core waveguides (LCWs) were included into a fiber-loop cavity ring-down absorption spectrometer to reduce the detection limit over, both, single pass absorption in a LCW and cavity-enhanced absorption using a conventional fiber-loop cavity. LCWs of 5 and 10 cm length were interfaced with a pressure-flow system and a multimode fiber-loop cavity using concave fiber lenses with matching numerical apertures and diameters. Two red dyes, Allura Red AC and Congo Red, were detected with a 532 nm pulsed laser at a 5 nM limit of detection in a detection volume of less than 1 µL, corresponding to a minimal detectable absorbance of less than 4 × 10(-4) cm(-1) and a minimal detectable change in absorption cross section, σ(min) = V(det) × Îµ × C(LOD), of about 14 µm(2) (Allura Red AC) and 37 µm(2) (Congo Red).


Assuntos
Cobalto/análise , DNA/análise , Compostos Ferrosos/química , Compostos Orgânicos/análise , Permanganato de Potássio/análise , Lasers , Dióxido de Silício/química , Espectrometria de Fluorescência
19.
Appl Opt ; 52(4): B40-5, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23385940

RESUMO

We report on the fabrication, modeling, and experimental verification of the emission of fiber lenses fabricated on multimode fibers in different media. Concave fiber lenses with a radius of 150 µm were fabricated onto a multimode silica fiber (100 µm core) by grinding and polishing against a ruby sphere template. In our theoretical model we assume that the fiber guides light from a Lambertian light source and that the emission cone is governed solely by the range of permitted emission angles. We investigate concave and convex lenses at 532 nm with different radii and in a variety of surrounding media from air (n(0)=1.00) to sapphire (n(0)=1.77). It was found that noticeable focusing or defocusing effects of a silica fiber lens in ethanol (n(0)=1.36) and dimethyl sulfoxide (DMSO) (n(0)=1.48) are only observed when the fiber lens radius was less than the fiber diameter.

20.
Opt Lett ; 38(3): 365-7, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23381439

RESUMO

We report a method for real-time monitoring of vapor uptake by simultaneous detection of the refractive index, n, and thickness, d, of thin transparent films with a precision of δn=10(-4) and δd<100 nm. The setup combines total internal reflection (Abbé) refractometry with an interferometric imaging method. A fast Fourier transform and phase fitting method is applied for accurate and independent determination of refractive indices and thicknesses. While the uptake of acetone vapor by polydimethylsiloxane is investigated, the system is also suited for characterization of other solid and liquid films.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...