Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 6(10): 1012-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24055444

RESUMO

OBJECTIVES: This study sought to investigate the efficacy and performance of the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in the treatment of de novo coronary lesions in patients with 2- to 3-vessel multivessel coronary artery disease (MV-CAD). BACKGROUND: Drug-eluting stents (DES) have emerged as an alternative to conventional coronary artery bypass surgery in patients with MV-CAD although first-generation DES yielded inferior efficacy and safety compared with surgery. METHODS: Prospective, randomized (1:1), multicenter feasibility trial was designed to assess angiographic efficacy of EES compared with the TAXUS paclitaxel-eluting stent (PES) in 200 patients, and a prospective, open-label, single-arm, controlled registry was designed to analyze the clinical outcome of EES at 1-year follow-up in 400 MV-CAD patients. For the randomized trial, the primary endpoint was in-stent late loss at 9 months. For the registry, the primary endpoint was a composite of all-cause death, myocardial infarction, and ischemia-driven target vessel revascularization at 12 months. RESULTS: The primary endpoint per single lesion was significantly lower in the EES group compared with the PES group (-0.03 ± 0.49 mm vs. 0.23 ± 0.51 mm, p = 0.001). Similar results were observed when analyzing all lesions (0.05 ± 0.51 mm vs. 0.24 ± 0.50 mm, p < 0.001). Clinical outcome at 1 year yielded a composite of major adverse cardiac events of 9.2% in the single-arm registry, and 11.1% and 16.5% in the EES and PES randomized groups, respectively (p = 0.30). CONCLUSIONS: The EXECUTIVE trial was a randomized pilot trial dedicated to the comparison of the efficacy of 2 different DES among patients with 2- to 3-vessel MV-CAD. The study shows lower in-stent late loss at 9 months with the EES XIENCE V compared with the PES TAXUS Libertè, and a low major adverse cardiac event rate at 1 year in patients with 2-to 3-vessel MV-CAD. (EXECUTIVE [EXecutive RCT: Evaluating XIENCE V in a Multi Vessel Disease]; NCT00531011).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Everolimo , Estudos de Viabilidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...