Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-27931180

RESUMO

Novel nanoparticles containing non-stick coatings have been developed for food contact applications such as frying pans. Possible release of nanoparticles from such coatings into food is not known. In this paper, the characterisation of commercially available non-stick coatings was performed by use of FTIR, electron and optical microscopy, EDXS and XRD analysis. Characterisation revealed that the coatings contained micron- and nanosized rutile TiO2 particles, and quartz SiO2 embedded in a silicone polymer matrix. In order to estimate possible migration of TiO2 nanoparticles from coatings into food, migration tests into simulants (deionised water, 3% acetic acid and 5 g l-1 citric acid) were performed (2 h at 100°C), and thermal and mechanical degradation of the matrix was studied. Simulants were analysed by ICP-MS after ultrafiltration and by microwave-assisted digestion. The concentration of titanium-containing particles that migrated into simulants was up to 861 µg l-1 (147 µg dm-2). Titanium was present in simulants in ionic form as well. The presence of TiO2 nanoparticles in 3% acetic acid was confirmed by SEM-EDXS analysis. Thermal stability study (TG/DSC MS analysis) did not show degradation of the matrix under foreseeable conditions of use, but mechanical degradation studies (scratch and tribological testing) showed possible release (microgram quantities per punched sample) of titanium-containing nanoparticles. The matrix degradation results were confirmed by observations of the morphology of the same type of coatings actually used for food preparation. Dissolution from the surface and matrix degradation can both contribute to nanoparticles release from this type of non-stick food contact coatings.


Assuntos
Contaminação de Alimentos/análise , Embalagem de Alimentos , Nanopartículas/análise , Titânio/análise , Liberação Controlada de Fármacos , Temperatura
2.
Nanoscale Res Lett ; 11(1): 378, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27562014

RESUMO

Surface charge is one of the most significant properties for the characterisation of a biomaterial, being a key parameter in the interaction of the body implant with the surrounding living tissues. The present study concerns the systematic assessment of the surface charge of electrochemically anodized TiO2 nanotubular surfaces, proposed as coating material for Ti body implants. Biologically relevant electrolytes (NaCl, PBS, cell medium) were chosen to simulate the physiological conditions. The measurements were accomplished as titration curves at low electrolytic concentration (10(-3) M) and as single points at fixed pH but at various electrolytic concentrations (up to 0.1 M). The results showed that all the surfaces were negatively charged at physiological pH. However, the zeta potential values were dependent on the electrolytic conditions (electrolyte ion concentration, multivalence of the electrolyte ions, etc.) and on the surface characteristics (nanotubes top diameter, average porosity, exposed surface area, wettability, affinity to specific ions, etc.). Accordingly, various explanations were proposed to support the different experimental data among the surfaces. Theoretical model of electric double layer which takes into account the asymmetric finite size of ions in electrolyte and orientational ordering of water dipoles was modified according to our specific system in order to interpret the experimental data. Experimental results were in agreement with the theoretical predictions. Overall, our results contribute to enrich the state-of-art on the characterisation of nanostructured implant surfaces at the bio-interface, especially in case of topographically porous and rough surfaces.

3.
J Mater Sci Mater Med ; 26(6): 191, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25989934

RESUMO

It is known that the "race for the surface" determining the in vivo response is strictly connected to the physico-chemical properties of the material, especially at its surface. Accordingly, the study of surface roughness, charge and wettability is fundamental to predict the bio-response to the implant. In this work, streaming potential was chosen as a reliable method to quantify the solid surface charge of hydrothermally treated (HT) TiO2-anatase nano-crystalline coatings, grown on titanium substrates. The influence of metal and ionic conductance on the zeta potential values was taken into account, allowing for the correlation of the surface charge with the coating porosity, the semiconductor character of the TiO2 nano-crystals and the metallic nature of the bulk titanium.


Assuntos
Materiais Revestidos Biocompatíveis/química , Próteses e Implantes , Titânio/química , Humanos , Teste de Materiais , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Varredura , Porosidade , Eletricidade Estática , Propriedades de Superfície , Molhabilidade
4.
Colloids Surf B Biointerfaces ; 129: 47-53, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25819365

RESUMO

Biomedical implants made of titanium-based materials are expected to have certain essential features including high bone-to-implant contact and optimum osteointegration, which are often influenced by the surface topography and physicochemical properties of titanium surfaces. The surface structure in the nanoscale regime is presumed to alter/facilitate the protein binding, cell adhesion and proliferation, thereby reducing post-operative complications with increased lifespan of biomedical implants. The novelty of our TiO2 nanostructures lies mainly in the high level control over their morphology and roughness by mere compositional change and optimisation of the experimental parameters. The present work focuses on the wetting behaviour of various nanostructured titanium surfaces towards water. Kinetics of contact area of water droplet on macroscopically flat, nanoporous and nanotubular titanium surface topologies was monitored under similar evaporation conditions. The contact area of the water droplet on hydrophobic titanium planar surface (foil) was found to decrease during evaporation, whereas the contact area of the droplet on hydrophobic nanorough titanium surfaces practically remained unaffected until the complete evaporation. This demonstrates that the surface morphology and roughness at the nanoscale level substantially affect the titanium dioxide surface-water droplet interaction, opposing to previous observations for microscale structured surfaces. The difference in surface topographic nanofeatures of nanostructured titanium surfaces could be correlated not only with the time-dependency of the contact area, but also with time-dependency of the contact angle and electrochemical properties of these surfaces.


Assuntos
Nanoestruturas/química , Titânio/química , Molhabilidade , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Propriedades de Superfície
5.
J Biomater Appl ; 30(1): 71-84, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25633960

RESUMO

Even though Ti-based implants are the most used materials for hard tissue replacement, they may present lack of osseointegration on the long term, due to their inertness. Hydrothermal treatment (HT) is a useful technique for the synthesis of firmly attached, highly crystalline coatings made of anatase titanium dioxide (TiO2), providing favorable nanoroughness and higher exposed surface area, as well as greater hydrophilicity, compared to the native amorphous oxide on pristine titanium. The hydrophilicity drops even more by photofunctionalization of the nanostructured TiO2-anatase coatings under UV light. Human mesenchymal stem cells exhibited a good response to the combination of the positive surface characteristics, especially in respect to the UVB pre-irradiation. The results showed that the cells were not harmed in terms of viability; even more, they were encouraged to differentiate in osteoblasts and to become osteogenically active, as confirmed by the calcium ion uptake and the formation of well-mineralized, bone-like nodule structures. In addition, the enrichment of hydroxyl groups on the HT-surfaces by UVB photofunctionalization accelerated the cell differentiation process and greatly improved the osteogenesis in comparison with the nonirradiated samples. The optimal surface characteristics of the HT-anatase coatings as well as the high potentiality of the photo-induced hydrophilicity, which was reached during a relatively short pre-irradiation time (5 h) with UVB light, can be correlated with better osseointegration ability in vivo; among the samples, the superior biological behavior of the roughest and most hydrophilic HT coating makes it a good candidate for further studies and applications.


Assuntos
Materiais Revestidos Biocompatíveis/metabolismo , Células-Tronco Mesenquimais/citologia , Osteogênese/efeitos dos fármacos , Titânio/metabolismo , Cálcio/metabolismo , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Materiais Revestidos Biocompatíveis/química , Feminino , Humanos , Masculino , Nanoestruturas/química , Osteoblastos/citologia , Próteses e Implantes , Propriedades de Superfície , Titânio/química , Raios Ultravioleta
6.
ACS Appl Mater Interfaces ; 7(3): 1644-51, 2015 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-25543452

RESUMO

This study examines bacterial adhesion on titanium-substrates used for bone implants. Adhesion is the most critical phase of bacterial colonization on medical devices. The surface of titanium was modified by hydrothermal treatment (HT) to synthesize nanostructured TiO2-anatase coatings, which were previously proven to improve corrosion resistance, affect the plasma protein adsorption, and enhance osteogenesis. The affinity of the anatase coatings toward bacterial attachment was studied by using a green fluorescent protein-expressing Escherichia coli (gfp-E. coli) strain in connection with surface photoactivation by UV irradiation. We also analyzed the effects of surface topography, roughness, charge, and wettability. The results suggested the dominant effects of the macroscopic surface topography, as well as microasperity at the surface roughness scale, which were produced during titanium machining, HT treatment, or both. Macroscopic grooves provided a preferential site for bacteria deposit within the valleys, while the microscopic roughness of the valleys determined the actual interaction surface between bacterium and substrate, resulting in an "interlocking" effect and undesired high bacterial adhesion on nontreated titanium. In the case of TiO2-coated samples, the nanocrystals reduced the width between the microasperities and thus added nanoroughness features. These factors decreased the contact area between the bacterium and the coating, with consequent lower bacterial adhesion (up to 50% less) in comparison to the nontreated titanium. On the other hand, the pronounced hydrophilicity of one of the HT-coated discs after pre-irradiation seemed to enhance the attachment of bacteria, although the increase was not statistically significant (p > 0.05). This observation may be explained by the acquired similar degree of wetting between gfp-E. coli and the coating. No correlation was found between the bacterial adhesion and the ζ-values of the samples in PBS, so the effect of surface charge was considered negligible in this study.


Assuntos
Aderência Bacteriana , Substitutos Ósseos/química , Materiais Revestidos Biocompatíveis/química , Escherichia coli/fisiologia , Titânio/química , Teste de Materiais , Propriedades de Superfície
7.
Mater Sci Eng C Mater Biol Appl ; 37: 390-8, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24582265

RESUMO

The paper reports on the photoinduced properties of hydrothermally treated (HT) titanium used for bone implants. The anatase coatings composed of 30-100nm anatase crystals exhibited high photocatalytic activity and good photo-induced wettability, reaching a superhydrophilic state, despite the larger crystal dimensions than the previously reported optimal ones. These properties are due to a suitable combination of surface texture, roughness, thickness, crystal morphology and particle size, which allowed the two independent photo-induced phenomena to occur simultaneously. The results on caffeine degradation by photocatalysis and the prolonged effect (up to two weeks) of photo-induced wettability in dark suggested a possible applicability of the HT anatase coatings as bacteria-repelling surfaces for body implants, in favor of a better osseointegration in vivo.


Assuntos
Substitutos Ósseos/química , Nanoestruturas/química , Titânio/química , Catálise , Humanos , Luz , Tamanho da Partícula , Próteses e Implantes , Propriedades de Superfície , Molhabilidade
8.
Materials (Basel) ; 7(1): 180-194, 2014 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-28788449

RESUMO

The electrochemical behavior of polycrystalline TiO2 anatase coatings prepared by a one-step hydrothermal synthesis on commercially pure (CP) Ti grade 2 and a Ti13Nb13Zr alloy for bone implants was investigated in Hank's solution at 37.5 °C. The aim was to verify to what extent the in-situ-grown anatase improved the behavior of the substrate in comparison to the bare substrates. Tafel-plot extrapolations from the potentiodynamic curves revealed a substantial improvement in the corrosion potentials for the anatase coatings. Moreover, the coatings grown on titanium also exhibited lower corrosion-current densities, indicating a longer survival of the implant. The results were explained by considering the effects of crystal morphology, coating thickness and porosity. Evidence for the existing porosity was obtained from corrosion and nano-indentation tests. The overall results indicated that the hydrothermally prepared anatase coatings, with the appropriate morphology and surface properties, have attractive prospects for use in medical devices, since better corrosion protection of the implant can be expected.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...