Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
BMC Med Res Methodol ; 23(1): 21, 2023 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-36681808

RESUMO

BACKGROUND: Patient-reported physical function (PF) is a key endpoint in cancer clinical trials. Using complex statistical methods, common metrics have been developed to compare scores from different patient-reported outcome (PRO) measures, but such methods do not account for possible differences in questionnaire content. Therefore, the aim of our study was a content comparison of frequently used PRO measures for PF in cancer patients. METHODS: Relying on the framework of the International Classification of Functioning, Disability and Health (ICF) we categorized the item content of the physical domains of the following measures: EORTC CAT Core, EORTC QLQ-C30, SF-36, PROMIS Cancer Item Bank for Physical Function, PROMIS Short Form for Physical Function 20a, and the FACT-G. Item content was linked to ICF categories by two independent reviewers. RESULTS: The 118 items investigated were assigned to 3 components ('d - Activities and Participation', 'b - Body Functions', and 'e - Environmental Factors') and 11 first-level ICF categories. All PF items of the EORTC measures but one were assigned to the first-level ICF categories 'd4 - Mobility' and 'd5 - Self-care', all within the component 'd - Activities and Participation'. The SF-36 additionally included item content related to 'd9 - Community, social and civic life' and the PROMIS Short Form for Physical Function 20a also included content related to 'd6 - domestic life'. The PROMIS Cancer Item Bank (v1.1) covered, in addition, two first-level categories within the component 'b - Body Functions'. The FACT-G Physical Well-being scale was found to be the most diverse scale with item content partly not covered by the ICF framework. DISCUSSION: Our results provide information about conceptual differences between common PRO measures for the assessment of PF in cancer patients. Our results complement quantitative information on psychometric characteristics of these measures and provide a better understanding of the possibilities of establishing common metrics.


Assuntos
Pessoas com Deficiência , Neoplasias , Humanos , Classificação Internacional de Funcionalidade, Incapacidade e Saúde , Medidas de Resultados Relatados pelo Paciente , Inquéritos e Questionários , Neoplasias/terapia , Avaliação da Deficiência , Atividades Cotidianas , Qualidade de Vida
2.
Knee Surg Sports Traumatol Arthrosc ; 28(3): 952-959, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31267191

RESUMO

PURPOSE: The aim of this study was to investigate the association of femoral (FT), tibial (TT), and knee torsion (KT) on the patella tilt (PT), the axial engagement index (AEI), and the tibial tuberosity-trochlear groove distance (TTTG). METHODS: Femoral torsion, tibial torsion, knee torsion, patella tilt, the axial engagement index, the TTTG, and trochlear dysplasia were retrospectively evaluated on 59 patients suffering from recurrent patella instability or anterior knee pain with 118 torsional lower limb magnetic resonance imaging studies. RESULTS: FT and TT did not show any significant associations with TTTG, PT, and AEI (n.s.). KT was significantly associated with a higher TTTG, higher PT, and lower AEI (all, p < 0.001). Higher grade trochlear dysplasia was associated with a higher PT and lower AEI (both, p < 0.001). The Dejour classification showed no significant association with FT, TT, KT, and TTTG (n.s.). All measurement parameters showed an excellent interrater agreement (ICC 0.89-0.97). CONCLUSIONS: Static patella tilt and patellofemoral axial engagement in knee extension are mainly influenced by knee torsion, TTTG, and trochlear dysplasia but not by femoral or tibial torsion. These findings help to understand the underlying reasons for the patella position in knee extensions in CT and MRI investigations in patients suffering from patella instability and patellofemoral pain syndrome. LEVEL OF EVIDENCE: III.


Assuntos
Fêmur/fisiopatologia , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Patela/fisiopatologia , Tíbia/fisiopatologia , Adolescente , Adulto , Mau Alinhamento Ósseo/diagnóstico por imagem , Mau Alinhamento Ósseo/patologia , Mau Alinhamento Ósseo/fisiopatologia , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/patologia , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/patologia , Tomografia Computadorizada por Raios X , Adulto Jovem
3.
Eur J Orthop Surg Traumatol ; 30(2): 267-274, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31820095

RESUMO

INTRODUCTION: Single-item questions assessing patient satisfaction following total hip or knee arthroplasty (THA/TKA) provide immediate and comprehensible information. However, they have limited reliability as satisfaction as a concept is influenced by factors unrelated to surgery. The aim of this retrospective study was to evaluate variation in pain, function and joint awareness relative to the patients' satisfaction response following THA/TKA. METHODS: We analysed absolute and improvement scores on the Oxford Knee or Hip score (OKS or OHS) and the Forgotten Joint Score-12 (FJS-12) across satisfaction groups. Patient-reported outcome measures were assessed prior to surgery and at 12-month follow-up. Postoperative satisfaction was assessed using a 5-point Likert scale single-item question. RESULTS: We analysed data from 434 TKA patients (mean age 70.4 ± 9.2 years; 54.8% female) and 247 THA patients (mean age 67.3 ± 11.8 years; 57.5% female). Satisfied or very satisfied patients showed higher absolute scores and better improvement in function, pain and joint awareness at 12 months (both, p < 0.001). 13.4% of (very) satisfied THA patients scored equally or worse on the FJS-12 than before surgery. On the OHS, this percentage was 2.8%. In TKAs, these percentages were 7.0% on the FJS-12 and 3.2% on the OKS. CONCLUSIONS: While higher satisfaction is associated with better patient-reported outcomes and stronger postoperative improvement, a certain percentage of patients score poorly while reporting a high satisfaction. Our results highlight the difficulty in interpreting the meaning of a single satisfaction question, as this provides limited information on patients' treatment outcome and may be biased by factors unrelated to the intervention.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Dor Pós-Operatória/epidemiologia , Satisfação do Paciente/estatística & dados numéricos , Recuperação de Função Fisiológica , Atividades Cotidianas , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/psicologia , Artroplastia de Quadril/estatística & dados numéricos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/psicologia , Artroplastia do Joelho/estatística & dados numéricos , Feminino , Humanos , Masculino , Dor Pós-Operatória/etiologia , Estudos Retrospectivos
4.
Knee Surg Sports Traumatol Arthrosc ; 26(11): 3257-3264, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29417168

RESUMO

PURPOSE: This study investigated the impact of body mass index (BMI) on improvement in patient outcomes (pain, function, joint awareness, general health and satisfaction) following total knee arthroplasty (TKA). METHODS: Data were obtained for primary TKAs performed at a single centre over a 12-month period. Data were collected pre-operatively and 12-month postoperatively with the Oxford Knee Score (OKS) measuring pain and function, the EQ-5D-3L measuring general health status, the Forgotten Joint Score-12 (FJS-12) measuring joint awareness and a single question on treatment satisfaction. Change in scores following surgery was compared across the BMI categories identified by the World Health Organization (< 25.0, 25.0-29.9, 30.0-34.9, 35.0-39.9 and ≥ 40.0). Differences in postoperative improvement between the BMI groups were analysed with an overall Kruskal-Wallis test, with post hoc pairwise comparisons between BMI groups with Mann-Whitney tests. RESULTS: Of 402 patients [mean age 70.7 (SD 9.2); 55.2% women] 15.7% were normal weight (BMI < 25.0), 33.1% were overweight (BMI 25.0-29.9), 28.2% had class I obesity (BMI 30.0-34.9), 16.2% had class II obesity (BMI 35.0-39.9), and 7.0% had class III obesity (BMI ≥ 40.0). Postoperative change in OKS (n.s.) and EQ-5D-3L (n.s.) was not associated with BMI. Higher BMI group was associated with less improvement in FJS-12 scores (p = 0.010), reflecting a greater awareness of the operated joint during activity in the most obese patients. Treatment satisfaction was associated with BMI category (p = 0.029), with obese patients reporting less satisfaction. CONCLUSIONS: In TKA patients, outcome parameters are influenced differently by BMI. Our study showed a negative impact of BMI on postoperative improvement in joint awareness and satisfaction scores, but there was no influence on pain, function or general health scores. This information may be useful in terms of setting expectations expectation in obese patients planning to undergo TKA. LEVEL OF EVIDENCE: Level 1.


Assuntos
Artroplastia do Joelho , Índice de Massa Corporal , Obesidade/complicações , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Idoso , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/fisiopatologia , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/fisiopatologia , Sobrepeso/complicações , Sobrepeso/fisiopatologia , Satisfação do Paciente , Propriocepção , Recuperação de Função Fisiológica , Resultado do Tratamento
5.
BMC Musculoskelet Disord ; 19(1): 5, 2018 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-29310652

RESUMO

BACKGROUND: Joint awareness was recently introduced as a new concept for outcome assessment after total knee arthroplasty (TKA). Findings from qualitative and psychometric studies suggest that joint awareness is a distinct concept especially relevant to patients with good surgical outcome and patients at late follow-up time points. The aim of this study was to improve the understanding of the concept of joint awareness by identifying situations in which patients are aware of their artificial knee joint and to investigate what bodily sensations and psychological factors raise a patient's awareness of her/his knee. In addition, we evaluated the relative importance of patient-reported outcome parameters that are commonly assessed in orthopaedics. METHODS: Qualitative interviews were conducted with patients being at least 12 months after TKA. The interviews focused on when, where and for what reasons patients were aware of their artificial knee joint. To evaluate the relative importance of 'joint awareness' after TKA among nine commonly assessed outcome parameters (e.g. pain or stiffness), we collected importance ratings ('0' indicating no importance at all and '10' indicating high importance). RESULTS: We conducted interviews with 40 TKA patients (mean age 69.0 years; 65.0% female). Joint awareness was found to be frequently triggered by kneeling on the floor (30%), climbing stairs (25%), and starting up after resting (25%). Patients reported joint awareness to be related to activities of daily living (68%), specific movements (60%), or meteoropathy (18%). Sensations causing joint awareness included pain (45%) or stiffness (15%). Psychological factors raising a patient's awareness of his/her knee comprised for example feelings of insecurity (15%), and fears related to revision surgeries, inflammations or recurring pain (8%). Patients' importance ratings of outcome parameters were generally high and did not allow differentiating clearly among them. CONCLUSIONS: We have identified a wide range of situations, activities, movements and psychological factors contributing to patients' awareness of their artificial knee joints. This improves the understanding of the concept of joint awareness and of a patient's perception of his/her artificial knee joint. The diversity of sensations and factors raising patient's awareness of their joint encourages taking a broader perspective on outcome after TKA.


Assuntos
Atividades Cotidianas/psicologia , Artroplastia do Joelho/psicologia , Conscientização , Prótese do Joelho , Medição da Dor/psicologia , Idoso , Artroplastia do Joelho/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor/tendências
6.
Psychol Med ; 48(10): 1634-1643, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29048273

RESUMO

BACKGROUND: Prior research has typically found a negative relationship between chronic pain and memory, and we examined whether cognitive control processes (e.g. reflection and rumination) moderated this relationship in individuals with Chiari malformation Type I (CM). CM is a neurological condition in which the cerebellar tonsils descend into the medullary and upper cervical spine regions potentially resulting in severe headaches and neck pain. METHODS: CM patients who had (n = 341) and had not (n = 297) undergone decompression surgery completed the McGill Pain Questionnaire-Short Form-Revised (SF-MPQ-2), the Rey Auditory Verbal Learning Test (RAVLT), and the Rumination-Reflection Questionnaire (RRQ). Immediate recall scores were compared to those of 102 healthy controls, and delayed recall performance was compared across other variables within the CM group. RESULTS: CM patients performed more poorly on immediate recall than did controls. Within CM patients, we observed main effects for reflection and age, and a pain x reflection x surgical status (surgery v. no surgery) interaction in which non-decompressed individuals with low levels of pain and high levels of reflection showed superior delayed recall relative to non-decompressed individuals with higher pain and all decompressed individuals. CONCLUSIONS: CM patients show an immediate recall deficit relative to controls, regardless of surgical status. High levels of reflection were associated with better delayed recall performance in non-decompressed CM patients with lower pain levels. High levels of chronic pain may overwhelm increased focused attention abilities, but higher levels of reflection partially overcome the distracting effects of pain and this may represent a type of resilience.


Assuntos
Malformação de Arnold-Chiari/fisiopatologia , Malformação de Arnold-Chiari/cirurgia , Atenção/fisiologia , Dor Crônica/fisiopatologia , Disfunção Cognitiva/fisiopatologia , Memória de Curto Prazo/fisiologia , Rememoração Mental/fisiologia , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros , Ruminação Cognitiva/fisiologia , Adulto , Malformação de Arnold-Chiari/complicações , Dor Crônica/etiologia , Disfunção Cognitiva/etiologia , Descompressão Cirúrgica , Feminino , Humanos , Masculino
7.
Bone Joint J ; 99-B(2): 218-224, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28148664

RESUMO

AIMS: To validate the English language Forgotten Joint Score-12 (FJS-12) as a tool to evaluate the outcome of hip and knee arthroplasty in a United Kingdom population. PATIENTS AND METHODS: All patients undergoing surgery between January and August 2014 were eligible for inclusion. Prospective data were collected from 205 patients undergoing total hip arthroplasty (THA) and 231 patients undergoing total knee arthroplasty (TKA). Outcomes were assessed with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively, then at six and 12 months post-operatively. Internal consistency, convergent validity, effect size, relative validity and ceiling effects were determined. RESULTS: Data for the TKA and THA patients showed high internal consistency for the FJS-12 (Cronbach α = 0.97 in TKAs, 0.98 in THAs). Convergent validity with the Oxford Scores was high (r = 0.85 in TKAs, r = 0.79 for THAs). From six to 12 months, the change was higher for the FJS-12 than for the OHS in THA patients (effect size d = 0.21 versus -0.03). Ceiling effects at one-year follow-up were low for the FJS-12 with just 3.9% (TKA) and 8.8% (THA) of patients achieving the best possible score. CONCLUSION: The FJS-12 has strong measurement properties in terms of validity, internal consistency and sensitivity to change in TKA and THA patients. Low ceiling effects and good relative validity allow the monitoring of longer term outcomes, particularly in well-performing groups after total joint arthroplasty. Cite this article: Bone Joint J 2017;99-B:218-24.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Indicadores Básicos de Saúde , Osteoartrite/cirurgia , Idoso , Artroplastia de Quadril/psicologia , Artroplastia do Joelho/psicologia , Conscientização , Feminino , Humanos , Masculino , Osteoartrite/psicologia , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Psicometria , Recuperação de Função Fisiológica , Reino Unido
8.
Patient Educ Couns ; 99(12): 2012-2017, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27506581

RESUMO

OBJECTIVE: To investigate cancer patients' understanding of graphical presentations of longitudinal EORTC QLQ-C30 scores. METHODS: We conducted semi-structured interviews with brain tumour patients participating in routine patient-reported outcome (PRO) monitoring. We assessed understanding of longitudinal quality of life (QOL) profiles, presented as bar charts objectively and with self-ratings. In addition, patients' opinions on congruency of the QOL scores with their self-perceived health status were evaluated. RESULTS: We recruited 40 brain tumour patients (57.5% female; mean age 52.7, SD 13.7). In total, 90% of patients rated the graphs as easy to understand. Accordingly, almost all questions on assessing understanding objectively were answered correctly by at least 80% of the patients. More than 95% indicated that the displayed QOL scores matched their personal perception of symptom burden and functional health in the observed period. CONCLUSION: Patients are able to understand their QOL results when presented graphically and are able to interpret important changes. Displayed QOL scores obtained with the EORTC QLQ-C30 are consistent with the patients' personal perception of physical and emotional functioning, pain and fatigue. PRACTICE IMPLICATIONS: Knowledge about patients' understanding of graphically displayed QOL results contributes to creation of optimal evidence-based feedback on the patients' present QOL and its trajectory.


Assuntos
Neoplasias Encefálicas/psicologia , Compreensão , Gráficos por Computador , Letramento em Saúde , Qualidade de Vida , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fadiga , Feminino , Humanos , Entrevistas como Assunto , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Pesquisa Qualitativa , Inquéritos e Questionários
10.
J Child Psychol Psychiatry ; 43(7): 885-900, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12405477

RESUMO

BACKGROUND: The study investigated the development of theory-of-mind (ToM) knowledge in children with lesser variants' of autism (PDD-NOS) over a period thought to be critical for ToM development (i.e., 3 to 5 years of age). METHOD: The sample included 11 children with PDD-NOS; 23 normally developing children were included for cross-sectional comparison and 13 normally developing children for longitudinal comparison. The groups were comparable in verbal and non-verbal mental age. Two storybooks were used for repeated assessment of various aspects of the children's theory of mind: emotion recognition, the distinction between physical and mental entities, prediction of behaviour and emotions on the basis of desires and prediction of behaviour and emotions on the basis of beliefs. RESULTS: The results showed that the children with PDD-NOS had specific difficulties in understanding and predicting other people's emotions on the basis of situational cues, desires and beliefs. However, their ability to predict actions from beliefs and desires were relatively intact. Compared to the normally developing children, these children achieved lower levels of theory-of-mind knowledge, both at time of initial assessment and approximately 6 months later. CONCLUSIONS: The data suggest that the theory-of-mind development of children with PDD-NOS is both delayed and deviant. The growth pattem of theory-of-mind skills in children with PDD-NOS seemed to be qualitatively different from the growth pattern found in the group of normally developing children.


Assuntos
Transtornos Globais do Desenvolvimento Infantil/fisiopatologia , Cognição , Emoções , Teoria Psicológica , Comportamento Social , Transtornos Globais do Desenvolvimento Infantil/psicologia , Pré-Escolar , Análise por Conglomerados , Formação de Conceito , Cultura , Expressão Facial , Humanos , Estudos Longitudinais , Masculino
11.
J Biomech Eng ; 123(4): 372-6, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11563764

RESUMO

A method is described for construction of an in vitro flow model based on in vivo measurements of the lumen geometry of the human carotid bifurcation. A large-scale physical model of the vessel lumen was constructed using fused deposition modeling (a rapid prototyping technique) based on magnetic resonance (MR) images of the carotid bifurcation acquired in a healthy volunteer. The lumen negative was then used to construct a flow model for experimental studies that examined the hemodynamic environment of subject-specific geometry and flow conditions. The physical model also supplements physician insight into the three-dimensional geometry of the arterial segment, complementing the two-dimensional images obtained by MR. Study of the specific geometry and flow conditions in patients with vascular disease may contribute to our understanding of the relationship between their hemodvnamic environment and conditions that lead to the development and progression of arterial disease.


Assuntos
Artérias Carótidas/anatomia & histologia , Artérias Carótidas/fisiologia , Modelos Cardiovasculares , Adulto , Fenômenos Biomecânicos , Engenharia Biomédica , Simulação por Computador , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Imageamento por Ressonância Magnética , Masculino
12.
Joint Bone Spine ; 68(1): 74-5, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11235786

RESUMO

Bone lesions are fairly uncommon in sarcoidosis (5 to 10% of cases). We report the case of a 40-year-old man in whom sarcoidosis of the lungs and bones was revealed by excruciating buttock and sacral pain. Computed tomography showed multiple punched-out defects in the left iliac bone. No similar cases have been reported in the literature.


Assuntos
Doenças Ósseas/diagnóstico por imagem , Ílio/diagnóstico por imagem , Sarcoidose/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Humanos , Masculino , Dor/etiologia
13.
J Biomech Eng ; 123(1): 71-9, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11277305

RESUMO

The fluid that resides within cranial and spinal cavities, cerebrospinal fluid (CSF), moves in a pulsatile fashion to and from the cranial cavity. This motion can be measured hy magnetic resonance imaging (MRI) and may he of clinical importance in the diagnosis of several brain and spinal cord disorders such as hydrocephalus, Chiari malformation, and syringomyelia. In the present work, a geometric and hydrodynamic characterization of an anatomically relevant spinal canal model is presented. We found that inertial effects dominate the flow field under normal physiological flow rates. Along the length of the spinal canal, hydraulic diameter was found to vary significantly from 5 to 15 mm. The instantaneous Reynolds number at peak flow rate ranged from 150 to 450, and the Womersle number ranged from 5 to 17. Pulsatile flow calculations are presented for an idealized geometric representation of the spinal cavity. A linearized Navier-Stokes model of the pulsatile CSF flow was constructed based on MRI flow rate measurements taken on a healthy volunteer. The numerical model was employed to investigate effects of cross-sectional geometry and spinal cord motion on unsteady velocity, shear stress, and pressure gradientfields. The velocity field was shown to be blunt, due to the inertial character of the flow, with velocity peaks located near the boundaries of the spinal canal rather than at the midpoint between boundaries. The pressure gradient waveform was found to be almost exclusively dependent on the flow waveform and cross-sectional area. Characterization of the CSF dynamics in normal and diseased states may be important in understanding the pathophysiology of CSF related disorders. Flow models coupled with MRI flow measurements mnay become a noninvasive tool to explain the abnormal dynamics of CSF in related brain disorders as well as to determine concentration and local distribution of drugs delivered into the CSF space.


Assuntos
Líquido Cefalorraquidiano/fisiologia , Modelos Biológicos , Canal Medular/anatomia & histologia , Canal Medular/fisiologia , Anatomia Transversal , Humanos , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Reologia , Estresse Mecânico
14.
J Biomech Eng ; 123(1): 80-7, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11277306

RESUMO

Various hemodynamic factors have been implicated in vascular graft intimal hyperplasia, the major mechanism contributing to chronic failure of small-diameter grafts. However, a thorough knowledge of the graft flow field is needed in order to determine the role of hemodynamics and how these factors affect the underlying biological processes. Computational fluid dynamics offers much more versatility and resolution than in vitro or in vivo methods, yet computations must be validated by careful comparison with experimental data. Whereas numerous numerical and in vitro simulations of arterial geometries have been reported, direct point-by-point comparisons of the two techniques are rare in the literature. We have conducted finite element computational analyses for a model of an end-to-side vascular graft and compared the results with experimental data obtained using laser-Doppler velocimetry. Agreement for velocity profiles is found to be good, with some clear differences near the recirculation zones during the deceleration and reverse-flow segments of the flow waveform. Wall shear stresses are determined from velocity gradients, whether by computational or experimental methods, and hence the agreement for this quantity, while still good, is less consistent than for velocity itself from the wall shear stress numerical results, we computed four variables that have been cited in the development of intiimal hyperplasia-the time-averaged wall shear stress, an oscillating shear index, and spatial and temporal wall shear stress gradients in order to illustrate the versatility of numerical methods. We conclude that the computational approach is a valid alternative to the experimental approach for quantitative hemodynamic studies. Where differences in velocity were found by the two methods, it was generally attributed to the inability of the numerical method to model the fluid dynamics when flow conditions are destabilizing. Differences in wall shear, in the absence of destabilizing phenomena, were more likely to be caused by difficulties in calculating wall shear from relatively low resolution in vitro data.


Assuntos
Artérias/fisiopatologia , Artérias/cirurgia , Prótese Vascular , Modelos Cardiovasculares , Anastomose Cirúrgica , Animais , Velocidade do Fluxo Sanguíneo , Cães , Hemodinâmica , Fluxometria por Laser-Doppler , Fluxo Pulsátil , Reprodutibilidade dos Testes , Estresse Mecânico
15.
Ann Vasc Surg ; 15(1): 110-22, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11221936

RESUMO

The long-term patency of infrainguinal vein grafts appears to depend primarily on the size and quality of the venous conduit. Therefore, those quantities which directly relate to the conduit's ability to act as a transporter of blood, namely internal diameter and longitudinal impedance (Z(L)), have predictive value for patency. Autologous grafts of good quality frequently remain patent even with compromised outflow. Therefore, those quantities that are outflow dependent, including deltaP, flow, velocity, shear stress, and resistance, carry less predictive value for long-term performance.


Assuntos
Hemodinâmica , Perna (Membro)/irrigação sanguínea , Veias/fisiologia , Veias/transplante , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Hemorreologia , Humanos , Contração Miocárdica , Fluxo Pulsátil , Estresse Mecânico , Grau de Desobstrução Vascular , Resistência Vascular , Procedimentos Cirúrgicos Vasculares
16.
Neurosurg Focus ; 11(1): E6, 2001 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16724816

RESUMO

OBJECT: A pilot study was performed to assess noninvasively the change in intracranial compliance (ICC) and intracranial pressure (ICP) in patients with Chiari I malformation who undergo foramen magnum decompression. The working hypothesis was that the main effect of the decompressive surgery is a change in ICP. Noninvasive cine phasecontrast magnetic resonance (MR) imaging is a motion-sensitive dynamic MR imaging technique that allows for visualization and quantitation of tissue motion and flow. The authors' group has used dynamic phase-contrast MR imaging to visualize and quantify pulsatile blood and cerebrospinal fluid (CSF) flow in the craniospinal system. METHODS: A system approach has been used to characterize the hemodynamic-hydrodynamic coupling in the craniospinal system and to derive measures for ICC and ICP. Magnetic resonance imaging-based ICC and ICP values are derived from the ratio of the volume and pressure changes that occur naturally during each cardiac cycle. The authors conducted a prospective study of four patients, three of whom were studied before and after decompressive surgery; significant change in MR imaging-derived ICC and ICP values was documented in only one of the three surgically treated patients. A significant change in the dynamics of the intracranial volume change (ICVC) during the cardiac cycle, however, was observed in all three patients. In healthy individuals the ICVC waveform usually consists of the following sequence: monotonic increase in intracranial volume (ICV) during the systolic phase due to increased blood inflow, monotonic decrease in ICV caused by the onset of CSF outflow into the spinal canal, and increase in the venous outflow. A nonmonotonic decline in the ICVC waveform has been observed in all patients with headaches, and a relatively normal waveform was found in those without headaches or whose headaches were resolved or alleviated by the surgery. A "partial-valve" mechanism is proposed as an explanation for the abnormal ICVC dynamics. The monotonic decline in ICVC is interrupted by a "premature" reduction in the CSF outflow. This may be caused by a displacement of the hindbrain into the cervical spinal canal during the systolic phase. This obstructs the CSF flow at the later part of the systolic phase such that the ICV does not continue its gradual decline. Postsurgery, the ICVC waveforms presented a more normal-appearing ICVC dynamics profile. CONCLUSIONS: Magnetic resonance imaging measurement of transcranial CSF and blood flow may lead to a better understanding of the pathophysiology of Chiari malformations and may prove to be an important diagnostic tool for guiding for the treatment of patients with Chiari I malformation.


Assuntos
Malformação de Arnold-Chiari/sangue , Malformação de Arnold-Chiari/líquido cefalorraquidiano , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Imageamento por Ressonância Magnética , Adulto , Malformação de Arnold-Chiari/patologia , Malformação de Arnold-Chiari/cirurgia , Cerebelo/patologia , Cerebelo/cirurgia , Circulação Cerebrovascular/fisiologia , Complacência (Medida de Distensibilidade) , Descompressão Cirúrgica/métodos , Feminino , Forame Magno/patologia , Hemodinâmica/fisiologia , Humanos , Hidrocefalia/sangue , Hidrocefalia/líquido cefalorraquidiano , Hidrocefalia/patologia , Hidrocefalia/cirurgia , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Modelos Biológicos , Projetos Piloto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
17.
Radiology ; 217(3): 877-85, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11110957

RESUMO

PURPOSE: To develop a noninvasive method for intracranial elastance and intracranial pressure (ICP) measurement. MATERIALS AND METHODS: Intracranial volume and pressure changes were calculated from magnetic resonance (MR) imaging measurements of cerebrospinal fluid (CSF) and blood flow. The volume change was calculated from the net transcranial CSF and blood volumetric flow rates. The change in pressure was derived from the change in the CSF pressure gradient calculated from CSF velocity. An elastance index was derived from the ratio of pressure to volume change. The reproducibility of the elastance index measurement was established from four to five measurements in five healthy volunteers. The elastance index was measured and compared with invasive ICP measurements in five patients with an intraventricular catheter at MR imaging. False-positive and false-negative rates were established by using 25 measurements in eight healthy volunteers and six in four patients with chronically elevated ICP. RESULTS: The mean of the fractional SD of the elastance index in humans was 19.6%. The elastance index in the five patients with intraventricular catheters correlated well with the invasively measured ICP (R:(2) = 0.965; P: <.005). MR imaging-derived ICPs in the eight healthy volunteers were 4.2-12.4 mm Hg, all within normal range. Measurements in three of the four patients with chronically elevated ICP were 20.5-34.0 mm Hg, substantially higher than the normal limit. CONCLUSION: MR imaging-derived elastance index correlates with ICP over a wide range of ICP values. The sensitivity of the technique allows differentiation between normal and elevated ICP.


Assuntos
Pressão Intracraniana/fisiologia , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Animais , Pressão do Líquido Cefalorraquidiano/fisiologia , Feminino , Frequência Cardíaca , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Papio , Reprodutibilidade dos Testes
18.
Surg Neurol ; 54(2): 145-52; discussion 152-3, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11077096

RESUMO

BACKGROUND: Recent publications have pointed out the importance of evaluating patients with in-tandem stenosis and in particular the association of moderate stenosis of the extracranial internal carotid artery (ICA) with moderate or severe stenosis of the intracranial internal carotid artery. Such evaluations are needed in symptomatic patients before planning carotid endarterectomies because observations have shown that in some cases the removal of an extracranial lesion does not necessarily improve these symptoms. This paper examines the hemodynamic effects of in-tandem stenosis in the internal carotid artery. METHODS: Equations describing flow in arteries are modified to accommodate two regions of stenosis in tandem. An equivalent value of stenosis is derived such that two stenoses in tandem behave as a single stenosis with similar hemodynamic properties. The solution to this problem is solved mathematically and this was used to analyze the observations made in five studies published on in-tandem stenosis of the internal carotid artery. RESULTS: Equivalent stenoses for various values of extracranial and intracranial stenoses are presented. It was found that two stenotic lesions in tandem are not equivalent to a simple summation of both values. A graphical solution is presented to show the hemodynamic effects of both stenoses. CONCLUSIONS: The most critical determinant of hemodynamic compromise when two lesions are in tandem is the larger one. Hence removal of a more proximal lesion may have little effect on a larger distal lesion if the symptoms are due to hypoperfusion. It is important that one distinguish between hypoperfusion and thromboembolic causes of the symptoms. No conclusions about the risk of thromboembolic events after a carotid endarterectomy in the setting of a distal stenosis can be made from this study.


Assuntos
Encéfalo/irrigação sanguínea , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Hemodinâmica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/fisiopatologia , Diagnóstico por Imagem , Feminino , Humanos , Modelos Teóricos
19.
Magn Reson Imaging ; 18(6): 697-706, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10930779

RESUMO

In this paper, a method of three-dimensional (3D) vessel localization is presented to allow the identification of a vessel of interest, the selection of a vessel segment, and the determination of a slice orientation to improve the accuracy of phase-contrast magnetic resonance (PCMR) angiography. A marching-cube surface-rendering algorithm was used to reconstruct the 3D vasculature. Surface-rendering was obtained using an iso-surface value determined from a maximum intensity projection (MIP) image. This 3D vasculature was used to find a vessel of interest, select a vessel segment, and to determine the slice orientation perpendicular to the vessel axis. Volumetric flow rate (VFR) was obtained in a phantom model and in vivo using 3D localization with double oblique cine PCMR scanning. PCMR flow measurements in the phantom showed 5. 2% maximum error and a standard deviation of 9 mL/min during steady flow, 7.9% maximum error and a standard deviation of 13 mL/min during pulsatile flow compared with measurements using an ultrasonic transit-time flowmeter. PCMR VFR measurement error increased with misalignment at 10, 20, and 30 degrees oblique to the perpendicular slice in vitro and in vivo. The 3D localization technique allowed precise localization of the vessel of interest and optimal placement of the slice orientation for minimum error in flow measurements.


Assuntos
Encéfalo/anatomia & histologia , Artérias Carótidas/anatomia & histologia , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Encéfalo/irrigação sanguínea , Artérias Carótidas/fisiologia , Artérias Cerebrais/anatomia & histologia , Artérias Cerebrais/fisiologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Fluxo Sanguíneo Regional
20.
J Vasc Surg ; 31(5): 910-7, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10805881

RESUMO

INTRODUCTION: Conduit size and quality are major determinants of the long-term success of infrainguinal autologous vein grafting. However, accurate measurement of the internal diameter of vein grafts is difficult given their variable wall thickness and taper. The purpose of this study was to define the "effective" internal diameter of a vein graft according to its hemodynamic properties and to determine its significance for graft patency. METHODS: Sixty infrainguinal bypass grafts performed on 57 patients were evaluated intraoperatively. Proximal and distal graft pressure and blood flow (Q(meas)) were measured with fluid-filled catheter transduction and ultrasonic transit-time flowimetry, respectively, after unclamping. Waveforms were recorded digitally at 200 Hz under baseline conditions and after stimulation with 60 mg of papaverine. According to Fourier transformation of the measured pressure gradient (DeltaP), the Womersley solution for fluid flow in a straight rigid tube was used to calculate theoretical flow waveforms (Q(calc)) for a range of graft diameters. The theoretical waveforms were then compared with the measured flow waveforms and the best-fit diameter chosen as the "effective hemodynamic diameter" (EHD). Only grafts in which the correlation coefficient of Q(calc) versus Q(meas) was more than 0.90 were accepted (n = 47) to assure validity of the hemodynamic model. After a mean follow-up of 12.5 months (range, 0.1-43.9 months), patency was determined by the life table method. Hemodynamic and clinical variables were tabulated, and their effect on patency determined the use of univariate and multivariate Cox regression. RESULTS: Mean EHD was 4.1 +/- 0.1 mm with a range of 2.5 to 5.7 mm. Administration of papaverine caused profound changes in DeltaP (+78% +/- 17%) and Q(meas) (+71% +/- 12%) as expected, but had no effect on EHD (+0.05% +/- 0.1%). Univariate regression identified five variables associated with decreased secondary patency (P <.10): low EHD, conduit source other than the greater saphenous vein, high baseline DeltaP(mean), female sex, and redo operation. Of these, only low EHD was significant after multivariate analysis (P =.03). Patency of small diameter grafts (EHD < 3.6 mm; n = 11) was compared with patency of larger grafts (EHD > 3.6 mm; n = 36) to test a frequently espoused clinical guideline. Grafts with an EHD less than 3.6 mm exhibited significantly lower secondary patency compared with larger grafts (P =.0001). The positive and negative predictive values for an EHD less than 3.6 mm for secondary graft failure for grafts with at least 1 year follow-up were 86% and 88%, respectively. CONCLUSION: An EHD is a unique parameter that quantifies conduit size and has a significant impact on vein graft patency. An EHD less than 3.6 mm portends graft failure.


Assuntos
Prótese Vascular , Hemodinâmica/fisiologia , Grau de Desobstrução Vascular/fisiologia , Idoso , Implante de Prótese Vascular , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Fluxo Pulsátil/fisiologia , Fatores de Tempo , Transplante Autólogo , Veias/patologia , Veias/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...