Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
2.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37724686

RESUMO

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Bradicardia , Progressão da Doença , Trifosfato de Adenosina
3.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37536671

RESUMO

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Cardiomiopatias , Canalopatias , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Canalopatias/complicações , Canalopatias/terapia , Resultado do Tratamento , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Sistema de Registros
4.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
6.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794691

RESUMO

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Casos e Controles , Morte Súbita Cardíaca/etiologia , Estudos Retrospectivos , Resultado do Tratamento
7.
Artigo em Inglês | MEDLINE | ID: mdl-35927601

RESUMO

BACKGROUND: The risk of complications has been shown to be lower with subcutaneous implantable defibrillator (S-ICD) than with conventional ICDs. Given the low frequency of complications, experience of how to manage them is limited. In this paper, we describe generator- and lead-related complications recorded in a series of S-ICD patients, and we propose our conservative approach to managing them. METHODS: The study cohort consisted of S-ICD patients who were referred to our institution owing to generator- or lead-related complications requiring surgical intervention. With our "shift and cover" approach, the system component involved is moved from its original position to an alternative, more protected location. In the case of the generator, this involves moving it to an intermuscular pocket. In the case of infections at the parasternal scar, the electrode sleeve is moved away from its original location, stitched, and then covered with the muscular fascia. RESULTS: Fourteen S-ICD patients were referred to our institution owing to system-related complications. Complications involved the generator in 7 cases (deep pocket infections with erosion, extrusion, or pain), the lead in 5 cases (parasternal infections at the xyphoid incision site), and both the generator and the lead in 2 cases. Complications were managed without completely removing the device and resolved in a single surgical session with no intraoperative complications. During defibrillation testing, the first shock at 65 J was effective in all patients. The shock impedance after revision was significantly lower than that measured during first implantation (59 ± 10 Ohm versus 86 ± 24 Ohm, P = 0.013). In all cases, the cosmetic result was satisfactory. No complications or recurrent infections were reported at the 12-month follow-up visit. CONCLUSIONS: The proposed conservative approach was successful in managing S-ICD complications. The revision procedure allowed to optimize the system configuration in terms of the defibrillation vector, resulting in lower shock impedance values and better device positioning.

9.
Int J Cardiol Heart Vasc ; 38: 100952, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35071727

RESUMO

BACKGROUND: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations. METHODS: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD. RESULTS: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values. CONCLUSIONS: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.

10.
J Cardiovasc Electrophysiol ; 33(1): 81-89, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797012

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. OBJECTIVE: To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. METHODS: Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. RESULTS: 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). CONCLUSIONS: Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Resultado do Tratamento
12.
Front Cardiovasc Med ; 8: 692943, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34395560

RESUMO

Background: When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction. Methods: We analyzed all consecutive patients who underwent S-ICD implantation after abandonment of malfunctioning leads and compared their outcomes with those of patients who underwent extraction and subsequent reimplantation of a single-chamber transvenous ICD (T-ICD). Results: Forty-three patients underwent S-ICD implantation after abandonment of malfunctioning leads, while 62 patients underwent extraction and subsequent reimplantation of a new T-ICD. The two groups were comparable. In the extraction group, no major complications occurred during extraction, while the procedure failed and an S-ICD was implanted in 4 patients. During a median follow-up of 21 months, 3 major complications or deaths occurred in the S-ICD group and 11 in the T-ICD group (HR 1.07; 95% CI 0.29-3.94; P = 0.912). Minor complications were 4 in the S-ICD group and 5 in the T-ICD group (HR 2.13; 95% CI 0.49-9.24; P = 0.238). Conclusions: In the event of ICD lead malfunction, extraction avoids the potential long-term risks of abandoned leads. Nonetheless the strategy of lead abandonment and S-ICD implantation was feasible and safe, with no significant increase in adverse outcomes, and may represent an option in selected clinical settings. Further studies are needed to fully understand the potential risks of lead abandonment. Clinical Trial Registration: URL: ClinicalTrials.gov Identifier: NCT02275637.

13.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33969578

RESUMO

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Assuntos
Desfibriladores Implantáveis , Índice de Massa Corporal , Cardioversão Elétrica/efeitos adversos , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Tela Subcutânea , Resultado do Tratamento
14.
Kardiol Pol ; 79(4): 442-448, 2021 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-33750083

RESUMO

BACKGROUND: Current guidelines recommend avoiding apical left ventricular (LV) pacing for cardiac resynchronization therapy (CRT). AIMS: We investigated the feasibility of nonapical pacing with the current quadripolar LV lead technology. METHODS: We analyzed consecutive patients who received CRT with an LV quadripolar lead. The post--implantation position of each electrode of the LV lead was designated as basal, mid, or apical. The pacing capture threshold (PCT) and phrenic nerve stimulation (PNS) threshold were assessed for each electrode. RESULTS: We enrolled 168 patients. A total of 8 CRT defibrillators were from Biotronik (with Sentus OTW QP leads), 98 were from Boston Scientific (with 21 Acuity X4 Spiral and 77 Acuity X4 Straight leads), and 62 from St. Jude Medical (with Quartet leads). The median (interquartile range) number of electrodes at nonapical segments per patient was 3 (1-4) with Biotronik Sentus leads, 4 (3-4) with spiral -design Boston Scientific leads, 4 (3-4) with straight Boston Scientific leads, and 3 (3-4) with St. Jude Medical Quartet leads (P = 0.045). Three patients (38%) with Biotronik Sentus leads, 21 (100%) with spiral -design Boston Scientific leads, 69 (90%) with straight -design Boston Scientific leads, and 49 (79%) with St. Jude Medical Quartet leads (P <0.001) had at least 1 electrode located at nonapical segments linked with a PNS -PCT safety margin of more than 2 V. During the 6-month follow -up, PNS was detected in 4 patients and was eliminated with reprogramming. No significant changes in PCT were detected during follow -up. CONCLUSIONS: Quadripolar leads allowed nonapical pacing with acceptable electrical parameters in the majority of CRT recipients, although differences were found among the currently available devices.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 7(6): 767-776, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33516714

RESUMO

OBJECTIVES: This study evaluated the efficacy of conversion test performed at 40 J (defibrillation margin ≥40 J), and factors potentially associated with test failure were identified. BACKGROUND: Current subcutaneous implantable cardioverter-defibrillator (S-ICD) devices deliver a maximum of 80 J. Functional defibrillation testing is recommended at S-ICD implantation, and it is usually conducted by delivering a shock energy of 65 J to ensure a safety defibrillation margin ≥15 J. Although high rates of successful conversion were reported at 65 J, limited data exist on the defibrillation margin extent. METHODS: Ventricular fibrillation was induced and conversion test was performed by delivering a 40-J shock in 308 patients. Success was defined as termination of ventricular fibrillation by the first shock delivered in standard polarity. The S-ICD system positioning was evaluated with the PRAETORIAN score using bidirectional chest X-rays. RESULTS: The generator was positioned in an intermuscular pocket in 301 patients (98%) and the lead was implanted by means of a 2-incision technique. The PRAETORIAN score was <90 (low risk of conversion failure) in 293 (95%) patients. Overall, ventricular fibrillation termination occurred in 259 (84%) patients with 40 J. Male gender (odds ratio [OR]: 3.79; 95% confidence interval [CI]: 1.09 to 13.14; p = 0.036), body mass index (OR: 1.09; 95% CI: 1.01 to 1.19; p = 0.036), dilated cardiomyopathy with reduced ejection fraction (OR: 0.42; 95% CI: 0.20 to 0.87; p = 0.019), and PRAETORIAN score >50 (OR: 2.93; 95% CI: 1.26 to 6.83; p = 0.013) were independently associated with conversion failure. CONCLUSIONS: The authors showed a high rate of defibrillation success with 40-J shocks in S-ICD systems implanted by means of modern surgical techniques. The variables associated with shock failure were male gender, higher body mass index, and suboptimal device position according to the PRAETORIAN score.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas , Desfibriladores Implantáveis/efeitos adversos , Humanos , Masculino , Fibrilação Ventricular/terapia
16.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33118017

RESUMO

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Fatores de Risco
17.
J Cardiovasc Electrophysiol ; 31(1): 144-149, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31778266

RESUMO

BACKGROUND: A two-incision technique, in association with inter-muscular positioning of the subcutaneous defibrillator (S-ICD), is now the most frequently adopted implantation approach in Europe. Ultrasound-guided serratus anterior plane block (SAPB) has been proposed to provide anesthesia/analgesia during S-ICD implantation. OBJECTIVE: We performed a case-control analysis in which a standardized SAPB approach was compared with the typical local anesthesia and sedation approach. METHODS: Ninety-one consecutive patients underwent implantation of an S-ICD with the SAPB approach for anesthesia/analgesia at 10 centers. The control group consisted of 55 consecutive patients who underwent S-ICD implantation with a standard local approach. RESULTS: The mean procedure duration was 59 ± 15 minutes in the SAPB group and 76 ± 23 minutes in the control group (P < .001). No operative complications were reported in either group. During the procedure, 79 (87%) patients in the SAPB group and 25 (46%) patients in the control group (P < .001) remained awake. Lower values of pain intensity at the device pocket (P = .005) and the lateral tunneling site (P = .046) were reported in the SAPB group. The difference in static (P = .002) and dynamic (P = .007) pain intensity between the groups persisted at 1 hour, while no differences were observed 6 hours after the end of the procedure. CONCLUSIONS: SAPB is feasible and effective in providing anesthesia/analgesia during S-ICD implantation. The procedures were successfully accomplished and no complications occurred in either group. However, SAPB was associated with lower pain levels, enabling the need for sedation to be reduced and more patients to remain awake. Moreover, it resulted in shorter procedure durations.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Músculo Esquelético/inervação , Bloqueio Nervoso , Dor Pós-Operatória/prevenção & controle , Implantação de Prótese/instrumentação , Adulto , Idoso , Estudos de Casos e Controles , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/efeitos adversos , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
J Interv Card Electrophysiol ; 56(3): 327-333, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31646429

RESUMO

PURPOSE: Sleep-related breathing disorders (SRBD) have been associated with adverse cardiovascular events and prognosis. Some modern pacemakers (PMK) and implantable cardioverter defibrillators (ICD) are equipped with thoracic impedance monitoring systems which allow detecting fluctuations in tidal volume occurring in SRBD. This study aimed at assessing the accuracy of a novel transthoracic impedance-based PMK/ICD sensor for automatic detection of SRBD. METHODS: We prospectively enrolled 31 consecutive patients scheduled for implantation of a PMK or an ICD with sleep respiratory disturbances monitoring capability. The results of unattended home nocturnal recordings expressed as apnea/hypopnea index (AHI) were compared with the respiratory disturbance index (RDI) stored in the cardiac device memory at the time polygraphy was performed. RESULTS: Among the 31 enrolled patients (20 men, mean age 70 ± 8 years), a comparison between the data from polygraphy and cardiac device was feasible in 29 patients. According to the results of home nocturnal recording, a severe SRBD was observed in 7/29 (24.1%) patients. On the basis of receiver-operating characteristic curve analysis of RDI values, the optimal RDI cutoff value to identify severe SRBD was 47 episodes/h (sensitivity 100%, specificity 100%). Bland-Altman agreement analysis of AHI-RDI revealed a bias between measurements of - 11 episodes/h, with limits of agreement - 38 to 15 episodes/h. CONCLUSIONS: In the present study, the novel transthoracic impedance-based monitoring system ApneaScanTM appeared effective in screening PMK and ICD patients for SRBD.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Polissonografia , Síndromes da Apneia do Sono/diagnóstico , Idoso , Cardiografia de Impedância , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos
19.
Eur J Intern Med ; 68: 13-17, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31353091

RESUMO

AIMS: Sleep apnea (SA) is a risk factor for atrial fibrillation (AF) occurrence. Sympathovagal imbalance is a mechanism that predisposes to the development of AF and that occurs in SA. Some pacemakers can detect SA events and continuously measure a time domain measure of heart rate variability (HRV), i.e. the standard deviation of 5-min median atrial-atrial sensed intervals (SDANN). We evaluated the association between the occurrence of AF and device-detected SA and SDANN in patients who received pacemakers. METHODS: We enrolled 150 consecutive patients undergoing implantation of a dual-chamber pacemaker, capable of SA and SDANN estimation. The SA was defined as severe if the Respiratory Disturbance Index was ≥30 episodes/h for at least one night during the first week after implantation. RESULTS: Sixteen patients in permanent AF were excluded from our analysis. During follow-up, AF (cumulative device-detected AF duration > 6 h/day) occurred in 24(18%) patients out of the remaining 134 patients. Severe SA was detected in 84 patients. SDANN values were available in 74 patients and the median value was 76 ms [25°-75°percentile:58-77]. The risk of AF was higher in patients with severe SA (log-rank test; p = .033). The presence of either or both conditions (severe SA and SDANN < 76 ms) was associated with shorter time to AF event (p = .042) and was an independent predictor of AF (hazard ratio: 2.37; 95%CI:1.08 to 5.21; p = .033). CONCLUSION: In pacemaker patients, device-diagnosed severe SA and reduced SDANN are associated with a higher risk of AF.


Assuntos
Fibrilação Atrial/etiologia , Frequência Cardíaca , Marca-Passo Artificial , Síndromes da Apneia do Sono/complicações , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Fatores de Risco , Síndromes da Apneia do Sono/fisiopatologia
20.
Heart Rhythm ; 16(10): 1531-1537, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31150817

RESUMO

BACKGROUND: At the time of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, successful termination of ventricular fibrillation (VF) is confirmed. A previous study reported cases of prolonged time to therapy during defibrillation testing. OBJECTIVES: We sought to evaluate the time to therapy, identify possible predictors of delay, and investigate the impact of delayed therapy on VF conversion. METHODS: We analyzed consecutive patients with S-ICDs who underwent initial conversion testing at a shock energy of 65 J in 53 Italian centers. RESULTS: We analyzed 570 patients (467 [82%] male; mean age 48 ± 15 years; mean body mass index 25 ± 6 kg/m2; mean ejection fraction 47% ± 17%). General anesthesia was used in 165 (29%) of patients, with sub- or intermuscular positioning of the generator in (422; 74%). Cardioversion was successful at 65 J in 557 (97.7%) of patients. In 12 patients (2.1%) the shock did not convert VF, and in 1 patient the shock was not delivered because of noise from entrapped subcutaneous air. All failures were successfully managed by reprogramming or repositioning the device. The mean time to therapy was 15 ± 3 seconds, and it exceeded 18 seconds in 51 patients (9%). Independent predictors of delayed therapy (18 seconds) were ejection fraction (odds ratio [OR] 0.98; 95% confidence interval [CI] 0.96-0.99; P = .016) and a 2× gain programmed (OR 3.66; 95% CI 1.44-9.30; P = .006). Effectiveness at 65 J was not associated with time to therapy (OR 1.13; 95% CI 0.97-1.32; P = .122). CONCLUSION: In this analysis of a large population of patients with S-ICDs, delayed therapy during defibrillation testing occurred less frequently than previously reported and had no effect on VF conversion success. Delayed therapies seemed more common when a vector with a 2× gain was programmed.


Assuntos
Cardioversão Elétrica , Eletrocardiografia/métodos , Tempo para o Tratamento , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/terapia , Adulto , Fatores Etários , Análise de Variância , Estudos de Coortes , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Taxa de Sobrevida , Resultado do Tratamento , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...