Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 208-209: 106047, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31526956

RESUMO

As part of an underground gas migration study, two radioactive noble gases (37Ar and 127Xe) and two stable tracer gases (SF6 and PFDMCH) were injected into a historic nuclear explosion test chimney and allowed to migrate naturally. The purpose of this experiment was to provide a bounding case (natural transport) for the flow of radioactive noble gases following an underground nuclear explosion. To accomplish this, soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 m) to deeper levels (~160 m) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species in the case when the driving pressure from the cavity is low. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.


Assuntos
Gases Nobres/análise , Armas Nucleares , Monitoramento de Radiação , Radioatividade , Explosões , Nevada , Medidas de Segurança
2.
J Environ Radioact ; 189: 207-212, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29698888

RESUMO

Radioactive isotopes of the noble gases xenon and argon are considered primary indicators of an underground nuclear explosion. However, high atmospheric concentrations from other anthropogenic sources may lead to an elevation in the underground levels of these gases, particularly in times of increasing atmospheric pressure. In 2014, a week long sampling campaign near Canadian Nuclear Laboratories in the Ottawa River Valley resulted in first of their kind measurements of atmospheric 133Xe that had been pressed into the subsurface. In an effort to better understand this imprinting process, a second follow-up sampling campaign was conducted in the same location in 2016. The results of the second sampling campaign, where samples were collected at depths of 1 m and 2 m over a 14 day period and measured for their 133Xe concentration, are presented here. Gas transport and sample concentrations were predicted using the Subsurface Transport over Multiple Phases (STOMP) simulator. These results are examined and compared to the corresponding experimental results.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação , Poluentes Radioativos do Ar/normas , Argônio , Canadá , Explosões , Gases Nobres , Armas Nucleares , Radioisótopos de Xenônio/análise
3.
J Environ Radioact ; 187: 65-72, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29449040

RESUMO

The detection of radioactive noble gases is a primary technology for verifying compliance with the pending Comprehensive Nuclear-Test-Ban Treaty. A fundamental challenge in applying this technology for detecting underground nuclear explosions is estimating the timing and magnitude of the radionuclide signatures. While the primary mechanism for transport is advective transport, either through barometric pumping or thermally driven advection, diffusive transport in the surrounding matrix also plays a secondary role. From the study of primordial noble gas signatures, it is known that xenon has a strong physical adsorption affinity in shale formations. Given the unselective nature of physical adsorption, isotherm measurements reported here show that non-trivial amounts of xenon adsorb on a variety of media, in addition to shale. A dual-porosity model is then discussed demonstrating that sorption amplifies the diffusive uptake of an adsorbing matrix from a fracture. This effect may reduce the radioxenon signature down to approximately one-tenth, similar to primordial xenon isotopic signatures.


Assuntos
Poluentes Radioativos do Ar/análise , Armas Nucleares , Monitoramento de Radiação , Radioisótopos de Xenônio/análise , Adsorção , Cooperação Internacional , Xenônio
4.
J Environ Radioact ; 178-179: 28-35, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28755564

RESUMO

Pacific Northwest National Laboratory reports on the detection of 39Ar at the location of an underground nuclear explosion on the Nevada Nuclear Security Site. The presence of 39Ar was not anticipated at the outset of the experimental campaign but results from this work demonstrated that it is present, along with 37Ar and 85Kr in the subsurface at the site of an underground nuclear explosion. Our analysis showed that by using state-of-the-art technology optimized for radioargon measurements, it was difficult to distinguish 39Ar from the fission product 85Kr. Proportional counters are currently used for high-sensitivity measurement of 37Ar and 39Ar. Physical and chemical separation processes are used to separate argon from air or soil gas, yielding pure argon with contaminant gases reduced to the parts-per-million level or below. However, even with purification at these levels, the beta decay signature of 85Kr can be mistaken for that of 39Ar, and the presence of either isotope increases the measurement background level for the measurement of 37Ar. Measured values for the 39Ar measured at the site ranged from 36,000 milli- Becquerel/standard-cubic-meter-of-air (mBq/SCM) for shallow bore holes to 997,000 mBq/SCM from the rubble chimney from the underground nuclear explosion.


Assuntos
Argônio/análise , Armas Nucleares , Monitoramento de Radiação , Poluentes Radioativos/análise , Nevada
5.
Appl Radiat Isot ; 126: 232-236, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28302444

RESUMO

As the world faces a challenging future in maintaining the commercial availability of radioactive isotopes for medical use, new methods of medical isotope production are being pursued. Many of these are small in size and could effectively operate continuously. With the potential for much shorter retention times, a new suite of isotopes may soon be found in the environment. The authors estimate that many more aerosols containing low-level isotopes of gas/volatile origin could be detectable at short range and times, and a few at longer ranges and times as compared to those released in more common nuclear reactor operations.

6.
Appl Radiat Isot ; 68(4-5): 893-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20122840

RESUMO

Improvised explosive devices (IEDs) pose a serious threat to society. The signature-based radiation scanning technology has been developed to counter this threat. This technology can be automated, requires minimal operator involvement, and in principle can rapidly identify IEDs from standoff distances. Preliminary research using neutron interrogation indicates that explosive samples of about 7 kg or greater hidden in various targets can be detected from standoff distances of more than a meter, with high sensitivity and high specificity.


Assuntos
Algoritmos , Substâncias Explosivas/análise , Reconhecimento Automatizado de Padrão/métodos , Difração de Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...