Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endod ; 49(9): 1183-1190, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37419243

RESUMO

INTRODUCTION: This study compared disinfection and shaping after root canal preparation with either XP-endo Shaper or TruNatomy instrument systems, supplemented by ultrasonic activation of sodium hypochlorite (NaOCl) with either stainless-steel (SS) or nickel-titanium (NiTi) inserts. METHODS: Mesial roots from mandibular molars with Vertucci class II configuration were divided into 2 groups (n = 24) based on anatomically paired micro-computed tomography (micro-CT) analyses. Pre and postpreparation micro-CT scans were obtained to evaluate the shaping performance. The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation with either XP-endo Shaper or TruNatomy instruments using NaOCl irrigation. Supplementary ultrasonic activation of NaOCl was conducted using either an SS (TruNatomy group) or NiTi (XP-endo Shaper group) insert. Bacteriological samples were taken from the canals before preparation (S1), after preparation (S2), and after the supplementary approach (S3). Bacterial reduction was evaluated using a quantitative real-time polymerase chain reaction. RESULTS: Preparation with both instrument systems significantly reduced bacterial counts (P < .01). After preparation, 36% (TruNatomy) and 35% (XP-endo Shaper) were negative for bacteria. These values increased to 59% and 65% after ultrasonic activation with the SS and NiTi inserts, respectively. The quantitative data in S2 showed that XP-endo Shaper promoted a significantly higher bacterial reduction than TruNatomy (P < .05). No significant intragroup differences were observed after ultrasonic activation (P > .05), probably because the SS insert promoted a significantly higher S2-to-S3 reduction than the NiTi insert (P < .01). Micro-CT analysis revealed no significant differences in the unprepared areas between the groups (P > .05). CONCLUSIONS: The XP-endo Shaper caused a significantly higher bacterial reduction than TruNatomy in Vertucci class II canals. Better antibacterial results after ultrasonic activation were observed for the SS ultrasonic inserts than for the NiTi inserts.


Assuntos
Cavidade Pulpar , Hipoclorito de Sódio , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/microbiologia , Hipoclorito de Sódio/uso terapêutico , Microtomografia por Raio-X , Desinfecção , Ultrassom , Preparo de Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...