Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 258: 116353, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38696966

RESUMO

Male infertility is a pervasive global reproductive challenge, primarily attributed to a decline in semen quality. Addressing this concern, there has been a growing focus on spermatozoa sorting in assisted reproductive technology. This study introduces a groundbreaking development in the form of a thermotaxis and rheotaxis microfluidic (TRMC) device designed for efficient motile spermatozoa sorting within a short 15-min timeframe. The TRMC device mimics the natural sperm sorting mechanism of the oviduct, selecting spermatozoa with superior motility and DNA integrity. The experimental outcomes demonstrate a remarkable enhancement in the percentage of progressive spermatozoa following sorting, soaring from 3.90% to an impressive 96.11% when subjected to a temperature decrease from 38 °C to 35 °C. Notably, sperm motility exhibited a substantial 69% improvement. The TRMC device exhibited a commendable recovery rate of 60.93%, surpassing current clinical requirements. Furthermore, the sorted spermatozoa displayed a notable reduction in the DNA fragmentation index to 6.94%, signifying a substantial 90% enhancement in DNA integrity. This remarkable advancement positions the TRMC device as highly suitable for applications in in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI), offering a promising solution to male infertility challenges.


Assuntos
Dispositivos Lab-On-A-Chip , Motilidade dos Espermatozoides , Espermatozoides , Masculino , Espermatozoides/fisiologia , Espermatozoides/citologia , Humanos , Desenho de Equipamento , Infertilidade Masculina , Técnicas Biossensoriais/instrumentação , Separação Celular/instrumentação , Fragmentação do DNA , Temperatura
2.
PLoS One ; 19(5): e0299602, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696439

RESUMO

PURPOSE: The purposes of this study were to determine whether biomechanical properties of mature oocytes could predict usable blastocyst formation better than morphological information or maternal factors, and to demonstrate the safety of the aspiration measurement procedure used to determine the biomechanical properties of oocytes. METHODS: A prospective split cohort study was conducted with patients from two IVF clinics who underwent in vitro fertilization. Each patient's oocytes were randomly divided into a measurement group and a control group. The aspiration depth into a micropipette was measured, and the biomechanical properties were derived. Oocyte fertilization, day 3 morphology, and blastocyst development were observed and compared between measured and unmeasured cohorts. A predictive classifier was trained to predict usable blastocyst formation and compared to the predictions of four experienced embryologists. RESULTS: 68 patients and their corresponding 1252 oocytes were included in the study. In the safety analyses, there was no significant difference between the cohorts for fertilization, while the day 3 and 5 embryo development were not negatively affected. Four embryologists predicted usable blastocyst development based on oocyte morphology with an average accuracy of 44% while the predictive classifier achieved an accuracy of 71%. Retaining the variables necessary for normal fertilization, only data from successfully fertilized oocytes were used, resulting in a classifier an accuracy of 81%. CONCLUSIONS: To date, there is no standard guideline or technique to aid in the selection of oocytes that have a higher likelihood of developing into usable blastocysts, which are chosen for transfer or vitrification. This study provides a comprehensive workflow of extracting biomechanical properties and building a predictive classifier using these properties to predict mature oocytes' developmental potential. The classifier has greater accuracy in predicting the formation of usable blastocysts than the predictions provided by morphological information or maternal factors. The measurement procedure did not negatively affect embryo culture outcomes. While further analysis is necessary, this study shows the potential of using biomechanical properties of oocytes to predict embryo developmental outcomes.


Assuntos
Blastocisto , Desenvolvimento Embrionário , Fertilização in vitro , Oócitos , Humanos , Blastocisto/fisiologia , Blastocisto/citologia , Feminino , Oócitos/fisiologia , Oócitos/citologia , Adulto , Fenômenos Biomecânicos , Fertilização in vitro/métodos , Desenvolvimento Embrionário/fisiologia , Estudos Prospectivos
3.
Int J Mol Sci ; 25(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38612482

RESUMO

Despite serum progesterone being a widely accepted method for luteal phase support during embryo transfer cycles, debates persist regarding the optimal strategy for guiding clinical decisions on progesterone dosages to maximize reproductive outcomes. This retrospective study explored the utility of microRNA (miRNA) biomarkers in guiding personalized progesterone dosage adjustments for frozen embryo transfer (FET) cycles in 22 in vitro fertilization (IVF) patients undergoing hormone replacement therapy. Utilizing MIRA, an miRNA-based endometrial receptivity test, we analyzed patients' miRNA expression profiles before and after progesterone dosage adjustments to determine suitable dosages and assess endometrial status. Despite patients receiving identical progesterone dosages, variations in miRNA profiles were observed in the initial cycle, and all patients presented a displaced window of implantation. Following dosage adjustments based on their miRNA profiles, 91% of patients successfully transitioned their endometrium towards the receptive stages. However, two patients continued to exhibit persistent displaced receptivity despite the adjustments. Given the evident variation in endometrial status and serum progesterone levels among individuals, analyzing miRNA expression profiles may address the challenge of inter-personal variation in serum progesterone levels, to deliver more personalized dosage adjustments and facilitate personalized luteal phase support in IVF.


Assuntos
MicroRNAs , Progesterona , Feminino , Humanos , Fase Luteal , Estudos Retrospectivos , MicroRNAs/genética , Transferência Embrionária , Endométrio
4.
Biomedicines ; 12(3)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38540313

RESUMO

Though tremendous advances have been made in the field of in vitro fertilization (IVF), a portion of patients are still affected by embryo implantation failure issues. One of the most significant factors contributing to implantation failure is a uterine condition called displaced window of implantation (WOI), which refers to an unsynchronized endometrium and embryo transfer time for IVF patients. Previous studies have shown that microRNAs (miRNAs) can be important biomarkers in the reproductive process. In this study, we aim to develop a miRNA-based classifier to identify the WOI for optimal time for embryo transfer. A reproductive-related PanelChip® was used to obtain the miRNA expression profiles from the 200 patients who underwent IVF treatment. In total, 143 out of the 167 miRNAs with amplification signals across 90% of the expression profiles were utilized to build a miRNA-based classifier. The microRNA-based classifier identified the optimal timing for embryo transfer with an accuracy of 93.9%, a sensitivity of 85.3%, and a specificity of 92.4% in the training set, and an accuracy of 88.5% in the testing set, showing high promise in accurately identifying the WOI for the optimal timing for embryo transfer.

5.
iScience ; 26(8): 107356, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37559897

RESUMO

Assisted reproductive technology (ART) is an important invention for the treatment of human infertility, and the isolation of high-quality sperm with progressive motility is one of the most critical steps that eventually affect the fertilization rate. Conventional sperm separation approaches include the swim-up method and density gradient centrifugation. However, the quality of isolated sperm obtained from both approaches can still be improved by improving sorted sperm motility, minimizing the DNA fragmentation rate, and removing abnormal phenotypes. Here, we report a Progressive Sperm Sorting Chip (PSSC) for high-quality sperm isolation. Based on the rheotaxis behavior of sperm, a gradient flow field is created in the chip for progressive sperm sorting. Clinical experiment results for 10 volunteers showed that greater than 90% of isolated sperm exhibit high motility (> 25 µm/s), high linearity (0.8), and a very low DNA fragmentation rate (< 5%). In addition, the whole process is label and chemical free. These features aid in gentle sperm sorting to obtain healthy sperm. This device uniquely enables the selection of high-quality sperm with progressive motility and might be clinically applied for infertility treatment in the near future.

6.
Int J Mol Sci ; 25(1)2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38203247

RESUMO

MicroRNAs (miRNAs) can regulate the expression of genes involved in the establishment of the window of implantation (WOI) in the endometrium. Recent studies indicated that cell-free miRNAs in uterine fluid and blood samples could act as alternative and non-invasive sample types for endometrial receptivity analysis. In this study, we attempt to systematically evaluate whether the expression levels of cell-free microRNAs in blood samples could be used as non-invasive biomarkers for assessing endometrial receptivity status. We profiled the miRNA expression levels of 111 blood samples using next-generation sequencing to establish a predictive model for the assessment of endometrial receptivity status. This model was validated with an independent dataset (n = 73). The overall accuracy is 95.9%. Specifically, we achieved accuracies of 95.9%, 95.9%, and 100.0% for the pre-receptive group, the receptive group, and the post-respective group, respectively. Additionally, we identified a set of differentially expressed miRNAs between different endometrial receptivity statuses using the following criteria: p-value < 0.05 and fold change greater than 1.5 or less than -1.5. In conclusion, the expression levels of cell-free miRNAs in blood samples can be utilized in a non-invasive manner to distinguish different endometrial receptivity statuses.


Assuntos
MicroRNA Circulante , MicroRNAs , Feminino , Humanos , Implantação do Embrião/genética , Transferência Embrionária , Endométrio , MicroRNAs/genética
7.
Fertil Steril ; 116(1): 181-188, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33823989

RESUMO

OBJECTIVE: To identify predictor microRNAs (miRNAs) from patients with repeated implantation failure (RIF). DESIGN: Systemic analysis of miRNA profiles from the endometrium of patients undergoing in vitro fertilization (IVF). SETTING: University research institute, private IVF center, and molecular testing laboratory. PATIENT(S): Twenty five infertile patients in the discovery cohort and 11 patients in the validation cohort. INTERVENTIONS(S): None. MAIN OUTCOME MEASURE(S): A signature set of miRNA associated with the risk of RIF. RESULT(S): We designed a reproductive disease-related PanelChip to access endometrium miRNA profiles in patients undergoing IVF. Three major miRNA signatures, including hsa-miR-20b-5p, hsa-miR-155-5p, and hsa-miR-718, were identified using infinite combination signature search algorithm analysis from 25 patients in the discovery cohort undergoing IVF. These miRNAs were used as biomarkers in the validation cohort of 11 patients. Finally, the 3-miRNA signature was capable of predicting patients with RIF with an accuracy >90%. CONCLUSION(S): Our findings indicated that specific endometrial miRNAs can be applied as diagnostic biomarkers to predict RIF. Such information will definitely help to increase the success rate of implantation practice.


Assuntos
Implantação do Embrião/genética , Transferência Embrionária , Endométrio/fisiopatologia , Fertilização in vitro , Perfilação da Expressão Gênica , Infertilidade/terapia , MicroRNAs/genética , Transcriptoma , Algoritmos , Transferência Embrionária/efeitos adversos , Feminino , Fertilização in vitro/efeitos adversos , Humanos , Infertilidade/diagnóstico , Infertilidade/genética , Infertilidade/fisiopatologia , Masculino , Valor Preditivo dos Testes , Gravidez , Reprodutibilidade dos Testes , Retratamento , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...