Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Org Inorg Au ; 4(3): 306-318, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38855334

RESUMO

Electrochemical water oxidation is known as the anodic reaction of water splitting. Efficient design and earth-abundant electrocatalysts are crucial to this process. Herein, we report a family of catalysts (1-3) bearing bis(benzimidazole)pyrazolide ligands (H 2 L1-H 2 L3). H 2 L3 contains electron-donating substituents and noninnocent components, resulting in catalyst 3 exhibiting unique performance. Kinetic studies show first-order kinetic dependence on [3] and [H2O] under neutral and alkaline conditions. In contrast to previously reported catalyst 1, catalyst 3 exhibits an insignificant kinetic isotope effect of 1.25 and zero-order dependence on [NaOH]. Based on various spectroscopic methods and computational findings, the L3Co2 III(µ-OH) species is proposed to be the catalyst resting state and the nucleophilic attack of water on this species is identified as the turnover-limiting step of the catalytic reaction. Computational studies provided insights into how the interplay between the electronic effect and ligand noninnocence results in catalyst 3 acting via a different reaction mechanism. The variation in the turnover-limiting step and catalytic potentials of species 1-3 leads to their catalytic rates being independent of the overpotential, as evidenced by Eyring analysis. Overall, we demonstrate how ligand design may be utilized to retain good water oxidation activity at low overpotentials.

2.
J Mass Spectrom ; 59(6): e5018, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38736378

RESUMO

This paper covers direct sub-atmospheric pressure ionization mass spectrometry (MS). The discovery, applications, and mechanistic aspects of novel ionization processes for use in MS that are not based on the high-energy input from voltage, laser, and/or high temperature but on sublimation/evaporation within a region linking a higher to lower pressure and modulated by heat and collisions, are discussed, including how this new reality has guided a series of discoveries, instrument developments, and commercialization. A research focus, inter alia, is on how best to understand, improve, and use these novel ionization processes, which convert volatile and nonvolatile compounds from solids (sublimation) or liquids (evaporation) into gas-phase ions for analysis by MS providing reproducible, accurate, sensitive, and prompt results. Our perception on how these unprecedented versus traditional ionization processes/methods relate to each other, how they can be made to coexist on the same mass spectrometer, and an outlook on new and expanded applications (e.g., clinical, portable, fast, safe, and autonomous) is presented, and is based on ST's Opening lecture presentation at the Nordic Mass spectrometry Conference, Geilo, Norway, January 2023. Focus will be on matrix-assisted ionization (MAI) and solvent-assisted ionization (SAI) MS covering the period from 2010 to 2023; a potential paradigm shift in the making.

3.
Analyst ; 149(6): 1766-1773, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38372348

RESUMO

Quantitative carbohydrate analysis faces challenges in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), including insufficient sensitivity and inconsistent spatial distribution of ion intensity. This study introduces an innovative sample preparation approach, the Rapidly Freeze-Drying Droplet (RFDD) method, aimed at overcoming these challenges by enhancing the homogeneity of the sample morphology and signal intensity in MALDI. Compared to conventional preparation methods, the RFDD method reduces the laser energy threshold and demonstrates a remarkable increase in signal intensity for carbohydrates, facilitating the detection of high-molecular-weight polysaccharides (>10 kDa). The RFDD-prepared samples exhibit a uniformly distributed signal intensity that overcomes the 'sweet spot' issue in MALDI. The enhanced signal intensity and reproducibility lead to reliable quantitative analysis of carbohydrates, eliminating the need for expensive isotopic standards in each sample. A straightforward and accessible approach is presented for general laboratories, revolutionizing carbohydrate analysis in MALDI-MS.


Assuntos
Carboidratos , Polissacarídeos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Reprodutibilidade dos Testes
4.
J Org Chem ; 87(22): 15327-15332, 2022 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-36302512

RESUMO

Hexamethyldisilazane was reacted with formamides to generate N,N-disubstituent formimidamide, after which a reaction with sulfonamides was induced to form sulfonylformamidines. This protocol can be applied for arylformamidine formation in which anilines are used as substrates under optimized conditions. The advantages of this method are high efficiency, structural diversity in products with good yields, and applicability in large-scale operations.


Assuntos
Formamidas , Compostos de Organossilício , Formamidas/química , Aminas/química , Sulfonamidas/química , Sulfanilamida
5.
ChemSusChem ; 15(21): e202201317, 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36083105

RESUMO

In this study, dinuclear cobalt complexes (1 and 2) featuring bis(benzimidazole)pyrazolide-type ligands (H2 L and Me2 L) were prepared and evaluated as molecular electrocatalysts for water oxidation. Notably, 1 bearing a non-innocent ligand (H2 L) displayed faster catalytic turnover than 2 under alkaline conditions, and the base dependence of water oxidation and kinetic isotope effect analysis indicated that the reaction mediated by 1 proceeded by a different mechanism relative to 2. Spectroelectrochemical, cold-spray ionization mass spectrometric and computational studies found that double deprotonation of 1 under alkaline conditions cathodically shifted the catalysis-initiating potential and further altered the turnover-limiting step from nucleophilic water attack on (H2 L)CoIII 2 (superoxo) to deprotonation of (L)CoIII 2 (OH)2 . The rate-overpotential analysis and catalytic Tafel plots showed that 1 exhibited a significantly higher rate than previously reported Ru-based dinuclear electrocatalysts at similar overpotentials. These observations suggest that using non-innocent ligands is a valuable strategy for designing effective metal-based molecular water oxidation catalysts.


Assuntos
Cobalto , Água , Cobalto/química , Ligantes , Água/química , Oxirredução , Catálise
6.
Inorg Chem ; 61(33): 13096-13103, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-35946578

RESUMO

We report on the remarkable stability of unprecedented, monomeric lead(II) hydrides M+[LPb(II)H]- (M[1-H]), where L = 2,6-bis(3,5-diphenylpyrrolyl)pyridine and M = (18-crown-6)potassium or ([2.2.2]-cryptand)potassium. The half-life of [K18c6][1-H] of ∼2 days in tetrahydrofuran at 25 °C is significantly longer than those reported for dimeric lead(II) hydrides supported by bulky terphenyl ligands (few hours at low temperatures), which are the only examples known for lead(II) hydride compounds. The presence of a Pb-H bond in [1-H]- was unambiguously identified by multinuclear NMR spectroscopy. Remarkably, a 1H resonance of the hydride ligand was found at δ = 41.43 ppm (1JPbH = 1312 Hz). For reactivity study, [1-H]- serves as an excellent hydroboration catalyst with high turnover numbers and turnover frequencies for several carbonyl compounds.

7.
Dalton Trans ; 51(1): 69-73, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34897306

RESUMO

The control of the self-assembly of lanthanide helical chain and their helical handedness have been investigated for the first time. Δ- and Λ-form lanthanide chain complexes were obtained by introducing thiazolidine ligands that were synthesised from L- and D-cysteine, respectively, and shared the same formula: [Ln2(L)3(H2O)5]∞·3H2O (Ln: Sm and Eu) (L: 2-(2-hydroxy-3,5-dinitrophenyl)thiazolidine-4-carboxylic acid). The crystallographic, circular dichroism, and luminescence properties of these novel lanthanide chain complexes were studied.

8.
ACS Omega ; 6(50): 35134-35143, 2021 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-34963994

RESUMO

Di(1-adamantyl)phosphine oxide (SPO-Ad: Ad2P(V)(=O)H), a stable tautomer of di(1-adamantyl)phosphinous acid (PA-Ad: Ad2P(III)-OH), was employed to synthesize two new PA-Ad-coordinated complexes, POPd-Ad and POPd2-Ad. POPd-Ad was easily transformed from POPd2-Ad in acetonitrile, and the [M - H]- ion of the deprotonated POPd-Ad was observed in the electrospray ionization-mass spectrum of POPd2-Ad. Both complexes are effective precatalysts for the Suzuki reaction of aryl chlorides. The reduction of Pd(II) in POPd-Ad and POPd2-Ad by arylboronic acid was examined, and the ideal Pd-to-PA ratio in the Suzuki reaction was found to be 1:1. The effect of temperature on the catalytic yields was studied to examine the possible ligation state of the active species and the dimer-to-monomer process of POPd2-Ad. Mononuclear and mono-ligated Pd species was assumed to be catalytically active. The electronic and steric effects of PA-Ad were slightly better than those reported for PA-tBu ( t Bu2P(III)-OH). Density functional theory calculations were performed to evaluate the formation of mono-ligated and mononuclear Pd species from POPd-Ad and POPd2-Ad. Furthermore, the reaction time and catalyst loading could be reduced for the reported POPd1-tBu precatalyst using the optimized reaction conditions for POPd-Ad. The complexes synthesized in this extensive study will complement the existing SPO-coordinated POPd series of precatalysts.

9.
Rapid Commun Mass Spectrom ; 35 Suppl 1: e8829, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32402102

RESUMO

RATIONALE: The developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential. METHODS: The inlet and vacuum ionization methods of solvent-assisted ionization (SAI), matrix-assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed. RESULTS: Results are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization. We demonstrate the utility of multi-ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub-atmospheric pressure (vacuum MAI). Simplicity and use of a wide array of matrices are attained using a conduit (inlet ionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on-probe reactions are analyzed directly and, especially in the case of vacuum ionization, without concern of carryover or instrument contamination. CONCLUSIONS: Examples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications.


Assuntos
Espectrometria de Massas , Animais , Bactérias/química , Desenho de Equipamento , Humanos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Camundongos , Imagem Molecular/instrumentação , Imagem Molecular/métodos , Vácuo
10.
Rapid Commun Mass Spectrom ; 35 Suppl 1: e8503, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31197905
11.
J Am Soc Mass Spectrom ; 32(1): 114-123, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33280376

RESUMO

Sublimation has been known at least since the middle ages. This process is frequently taught in schools through the use of phase diagrams. Astonishingly, such a well-known process appears to still harbor secrets. Under conditions in which compound sublimation occurs, gas-phase ions are frequently detected using mass spectrometry. This was exploited in matrix-assisted ionization in vacuum (vMAI) by adding analyte to subliming compounds used as matrices. Good vMAI matrices were those that ionize the added analyte with high sensitivity, but even matrices that fail this test often produce ions of likely matrix impurities suggesting that they may be good matrices for some compound types. We also show that binary matrices may be manipulated to provide desired properties such as fast analyses and improved sensitivity. These results imply that sublimation in some cases is more complicated than just molecules leaving a surface and that understanding the physical force responsible, and how the nonvolatile compound becomes charged, could lead to improved ionization efficiency for mass spectrometry. Here we provide insights into this process and an explanation of why this unexpected phenomenon has not previously been reported.

12.
Molecules ; 25(5)2020 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-32182713

RESUMO

Adenosine -5'-triphosphate (ATP) plays a valuable role in metabolic activity to produce adequate energy in a biosystem. A high ATP/AMP ratio has a correlation with diabetes that induces suppression of AMP-activated protein kinase (AMPK). Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry (MS) has outstanding potential in determining the ratio of several types of adenosine phosphates in a sample to rapidly understand the primary energy transfer in metabolism. Although MALDI is viewed as a soft ionization technique for MS analysis, excess photon energy might crack the phosphate bonds leading to misinterpretation of the ATP level. In this work, ionic liquid matrices (ILMs) were employed to reduce fragmentation and increase the detection efficiency during the MALDI process. This study demonstrated for the first time that 2,5-dihydroxybenzoic acid pyridine (DHBP) is one of the most effective matrices for further quantitative analysis of adenosine nucleotides. This systematic screening of ILMs also enhances the fundamental understanding of MALDI.


Assuntos
Trifosfato de Adenosina/química , Líquidos Iônicos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
13.
J Am Soc Mass Spectrom ; 29(2): 304-315, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29080207

RESUMO

Ionization processes have been discovered by which small and large as well as volatile and nonvolatile compounds are converted to gas-phase ions when associated with a matrix and exposed to sub-atmospheric pressure. Here, we discuss experiments further defining these simple and unexpected processes. Charge separation is found to be a common process for small molecule chemicals, solids and liquids, passed through an inlet tube from a higher to a lower pressure region, with and without heat applied. This charge separation process produces positively- and negatively-charged particles with widely different efficiencies depending on the compound and its physical state. Circumstantial evidence is presented suggesting that in the new ionization process, charged particles carry analyte into the gas phase, and desolvation of these particles produce the bare ions similar to electrospray ionization, except that solid particles appear likely to be involved. This mechanistic proposition is in agreement with previous theoretical work related to ion emission from ice. Graphical Abstract ᅟ.

14.
J Am Soc Mass Spectrom ; 28(10): 2235-2245, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28707193

RESUMO

Ultraviolet laser pulses at 355 nm with variable pulse widths in the region from 170 ps to 1.5 ns were used to investigate the ionization mechanism of matrix-assisted laser desorption/ionization (MALDI) for matrices 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and sinapinic acid (SA). The mass spectra of desorbed ions and the intensity and velocity distribution of desorbed neutrals were measured simultaneously for each laser shot. These quantities were found to be independent of the laser pulse width. A comparison of the experimental measurements and numerical simulations according to the multiphoton ionization, coupled photophysical and chemical dynamics (CPCD), and thermally induced proton transfer models showed that the predictions of thermally induced proton transfer model were in agreement with the experimental data, but those of the multiphoton ionization model were not. Moreover, the predictions of the CPCD model based on singlet-singlet energy pooling were inconsistent with the experimental data of CHCA and SA, but were consistent with the experimental data of DHB only when some parameters used in the model were adjusted to extreme values. Graphical Abstract ᅟ.

15.
J Mass Spectrom ; 51(12): 1180-1186, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27677117

RESUMO

Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mainly generate protonated ions from peptides and proteins but sodiated (or potassiated) ions from carbohydrates. The ion intensities of sodiated (or potassiated) carbohydrates generated by ESI and MALDI are generally lower than those of protonated peptides and proteins. Ab initio calculations and transition state theory were used to investigate the reasons for the low detection sensitivity for underivatized carbohydrates. We used glucose and cellobiose as examples and showed that the low detection sensitivity is partly attributable to the following factors. First, glucose exhibits a low proton affinity. Most protons generated by ESI or MALDI attach to water clusters and matrix molecules. Second, protonated glucose and cellobiose can easily undergo dehydration reactions. Third, the sodiation affinities of glucose and cellobiose are small. Some sodiated glucose and cellobiose dissociate into the sodium cations and neutral carbohydrates during ESI or MALDI process. The increase of detection sensitivity of carbohydrates in mass spectrometry by various methods can be rationalized according to these factors. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Carboidratos/análise , Carboidratos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cátions , Limite de Detecção
17.
J Am Soc Mass Spectrom ; 27(9): 1491-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27306427

RESUMO

In a study of the metal-related ion generation mechanism in matrix-assisted laser desorption ionization (MALDI), crystals of matrix used in MALDI were grown from matrix- and salt-containing solutions. The intensities of metal ion and metal adducts of the matrix ion obtained from unwashed crystals were higher than those from crystals washed with deionized water, indicating that metal ions and metal adducts of the matrix ions are mainly generated from the surface of crystals. The contributions of preformed metal ions and metal adducts of the matrix ions inside the matrix crystals were minor. Metal adducts of the matrix and analyte ion intensities generated from a mixture of dried matrix, salt, and analyte powders were similar to or higher than those generated from the powder of dried droplet crystals, indicating that the contributions of the preformed metal adducts of the matrix and analyte ions were insignificant. Correlation between metal-related ion intensity fluctuation and protonated ion intensity fluctuation was observed, indicating that the generation mechanism of the metal-related ions is similar to that of the protonated ions. Because the thermally induced proton transfer model effectively describes the generation of the protonated ions, we suggest that metal-related ions are mainly generated from the salt dissolution in the matrix melted by the laser. Graphical Abstract ᅟ.

18.
Artigo em Inglês | MEDLINE | ID: mdl-26132345

RESUMO

In past studies, mistakes in determining the ionization mechanism in matrix-assisted laser desorption/ionization (MALDI) were made because an inappropriate ion-to-neutral ratio was used. The ion-to-neutral ratio of the analyte differs substantially from that of the matrix in MALDI. However, these ratios were not carefully distinguished in previous studies. We begin by describing the properties of ion-to-neutral ratios and reviews early experimental measurements. A discussion of the errors committed in previous theoretical studies and a comparison of recent experimental measurements follow. We then describe a thermal proton transfer model and demonstrate how the model appropriately describes ion-to-neutral ratios and the total ion intensity. Arguments raised to challenge thermal ionization are then discussed. We demonstrate how none of the arguments are valid before concluding that thermal proton transfer must play a crucial role in the ionization process of MALDI.

19.
J Am Soc Mass Spectrom ; 26(7): 1242-51, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25851654

RESUMO

The ion-to-neutral ratios of four commonly used solid matrices, α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (2,5-DHB), sinapinic acid (SA), and ferulic acid (FA) in matrix-assisted laser desorption/ionization (MALDI) at 355 nm are reported. Ions are measured using a time-of-flight mass spectrometer combined with a time-sliced ion imaging detector. Neutrals are measured using a rotatable quadrupole mass spectrometer. The ion-to-neutral ratios of CHCA are three orders of magnitude larger than those of the other matrices at the same laser fluence. The ion-to-neutral ratios predicted using the thermal proton transfer model are similar to the experimental measurements, indicating that thermal proton transfer reactions play a major role in generating ions in ultraviolet-MALDI.

20.
J Chem Phys ; 141(16): 164307, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25362299

RESUMO

Matrix-assisted laser desorption ionization (MALDI) has been widely used in the mass analysis of biomolecules; however, there are a lot of debates about the ionization mechanisms. Previous studies have indicated that S1-S1 annihilation might be a key process in the generation of primary ions. This study investigates S1-S1 annihilation by examining the time-resolved fluorescence spectra of 12 matrices. No S1-S1 annihilation was observed in six of these matrices (3-hydroxy-picolinic acid, 6-aza-2-thiothymine, 2,4-dihydroxy-acetophenone, 2,6-dihydroxy-acetophenone, 2,4,6-trihydroxy-acetophenone, and ferulic acid). We observed two matrix molecules reacting in an electronically excited state (S1) in five of these matrices (2,5-dihydroxybenzoic acid, α-cyano-4-hydroxycinnamic acid, 2,5-dihydroxy-acetophenone, 2,3-dihydroxybenzoic acid, and 2,6-dihydroxybenzoic acid), and S1-S1 annihilation was a possible reaction. Among these five matrices, no S1-S1 annihilation was observed for 2,3-dihydroxybenzoic acid in typical peak power region of nanosecond laser pulses in MALDI, but a very small value of reaction rate constant was observed only in the high peak power region. The excited-state lifetime of sinapinic acid was too short to determine whether the molecules reacted in an electronically excited state. No correlation was observed between the ion generation efficiency of MALDI and S1-S1 annihilation. The results indicate that the proposal of S1-S1 annihilation is unnecessary in MALDI and energy pooling model for MALDI ionization mechanism has to be modified.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Lasers , Compostos Orgânicos/química , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...