1.
Chemistry ; 28(11): e202104385, 2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-34905636

RESUMO

Selective bioconjugation remains a significant challenge for the synthetic chemist due to the stringent reaction conditions required by biomolecules coupled with their high degree of functionality. The current trailblazer of transition-metal mediated bioconjugation chemistry involves the use of Pd(II) complexes prepared via an oxidative addition process. Herein, the preparation of Pd(II) complexes for cysteine bioconjugation via a facile C-H activation process is reported. These complexes show bioconjugation efficiency competitive with what is seen in the current literature, with a user-friendly synthesis, common Pd(II) sources, and a more cost-effective ligand. Furthermore, these complexes need not be isolated, and still achieve high conversion efficiency and selectivity of a model peptide. These complexes also demonstrate the ability to selectively arylate a single surface cysteine residue on a model protein substrate, further demonstrating their utility.


Assuntos
Cisteína , Paládio , Cisteína/química , Oxirredução , Paládio/química , Peptídeos/química , Proteínas/química
2.
Anal Bioanal Chem ; 412(23): 5563-5581, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32648103

RESUMO

This manuscript presents the development, validation and application of a multi-residue supercritical fluid chromatography coupled with tandem mass spectrometry method for the analysis of 140 chiral and non-chiral chemicals of emerging concern in environmental samples, with 81 compounds being fully quantitative, 14 semi-quantitative and 45 qualitative, validated according to European Medicine Agency (EMA) guidelines (European Medicines Agency 2019). One unified LC-MS method was used to analyse all analytes, which were split into three injection methods to ensure sufficient peak resolution. The unified method provided an average of 113% accuracy and 4.5% precision across the analyte range. Limits of detection were in the range of 35 pg L-1-0.7 µg L-1, in both river water and wastewater, with an average LOD of 33 ng L-1. The method was combined with solid-phase extraction and applied in environmental samples, showing very good accuracy and precision, as well as excellent chromatographic resolution of a range of chiral enantiomers including beta-blockers, benzodiazepines and antidepressants. The method resulted in quantification of 75% of analytes in at least two matrices, and 56% in the trio of environmental matrices of river water, effluent wastewater and influent wastewater, enabling its use in monitoring compounds of environmental concern, from their sources of origin through to their discharge into the environment.

5.
Anal Bioanal Chem ; 411(24): 6487-6496, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31375854

RESUMO

The fraction of intact monomer in a sample (moles/moles), the monomeric purity, is measured as a quality control in therapeutic monoclonal antibodies but is often unknown in research samples and remains a major source of variation in quantitative antibody-based techniques such as immunoassay development. Here, we describe a novel multiplex technique for estimating the monomeric purity and antigen affinity of research grade antibody samples. Light scattering was used to simultaneously observe the mass of antibody binding to biosensor surfaces functionalised with antigen (revealing Fab binding kinetics) or protein A/G (PAG). Initial estimates of monomeric purity in 7 antibody samples including a therapeutic infliximab biosimilar were estimated by observing a mass deficit on the PAG surface compared to the NISTmAb standard of high monomeric purity. Monomeric purity estimates were improved in a second step by observing the mass of antigen binding to the mass of antibody on the PAG surface. The NISTmAb and infliximab biosimilar displayed tightly controlled stoichiometries for antigen binding of 1.31 ± 0.57 and 1.71 ± 0.16 (95% confidence interval)-within the theoretical limit of 1-2 antigens per antibody depending on avidity. The other antibodies in the panel displayed antigen binding stoichiometries in the range 0.06-1.15, attributed to lower monomeric purity. The monomeric purity estimates were verified by electrospray ionization mass spectrometry (ESI), the gold standard technique for structural characterization of antibodies. ESI data indicated that the NISTmAb and infliximab biosimilar samples had monomeric purity values of 93.5% and 94.7%, respectively, whilst the research grade samples were significantly lower (54-89%). Our results demonstrate rapid quality control testing for monomeric purity of antibody samples (< 15 min) which could improve the reproducibility of antibody-based experiments.


Assuntos
Imunoglobulina G/isolamento & purificação , Calibragem , Padrões de Referência , Reprodutibilidade dos Testes
8.
J Clin Invest ; 128(9): 4044-4056, 2018 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-30102254

RESUMO

Neutrophil influx into the intestinal lumen is a critical response to infectious agents, but is also associated with severe intestinal damage observed in idiopathic inflammatory bowel disease. The chemoattractant hepoxilin A3, an eicosanoid secreted from intestinal epithelial cells by the apically restricted efflux pump multidrug resistance protein 2 (MRP2), mediates this neutrophil influx. Information about a possible counterbalance pathway that could signal the lack of or resolution of an apical inflammatory signal, however, has yet to be described. We now report a system with such hallmarks. Specifically, we identify endocannabinoids as the first known endogenous substrates of the apically restricted multidrug resistance transporter P-glycoprotein (P-gp) and reveal a mechanism, which we believe is novel, for endocannabinoid secretion into the intestinal lumen. Knockdown or inhibition of P-gp reduced luminal secretion levels of N-acyl ethanolamine-type endocannabinoids, which correlated with increased neutrophil transmigration in vitro and in vivo. Additionally, loss of CB2, the peripheral cannabinoid receptor, led to increased pathology and neutrophil influx in models of acute intestinal inflammation. These results define a key role for epithelial cells in balancing the constitutive secretion of antiinflammatory lipids with the stimulated secretion of proinflammatory lipids via surface efflux pumps in order to control neutrophil infiltration into the intestinal lumen and maintain homeostasis in the healthy intestine.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Endocanabinoides/metabolismo , Mucosa Intestinal/metabolismo , Infiltração de Neutrófilos/fisiologia , Subfamília B de Transportador de Cassetes de Ligação de ATP/deficiência , Subfamília B de Transportador de Cassetes de Ligação de ATP/genética , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/deficiência , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/genética , Animais , Transporte Biológico Ativo , Linhagem Celular , Modelos Animais de Doenças , Feminino , Homeostase , Humanos , Doenças Inflamatórias Intestinais/metabolismo , Doenças Inflamatórias Intestinais/patologia , Doenças Inflamatórias Intestinais/prevenção & controle , Mucosa Intestinal/citologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Modelos Biológicos , Proteína 2 Associada à Farmacorresistência Múltipla , Proteínas Associadas à Resistência a Múltiplos Medicamentos/metabolismo , Receptor CB2 de Canabinoide/deficiência , Receptor CB2 de Canabinoide/genética , Receptor CB2 de Canabinoide/metabolismo , Transdução de Sinais
9.
Genome Biol ; 19(1): 94, 2018 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-30021593

RESUMO

BACKGROUND: Fitness costs imposed on bacteria by antibiotic resistance mechanisms are believed to hamper their dissemination. The scale of these costs is highly variable. Some, including resistance of Staphylococcus aureus to the clinically important antibiotic mupirocin, have been reported as being cost-free, which suggests that there are few barriers preventing their global spread. However, this is not supported by surveillance data in healthy communities, which indicate that this resistance mechanism is relatively unsuccessful. RESULTS: Epistasis analysis on two collections of MRSA provides an explanation for this discord, where the mupirocin resistance-conferring mutation of the ileS gene appears to affect the levels of toxins produced by S. aureus when combined with specific polymorphisms at other loci. Proteomic analysis demonstrates that the activity of the secretory apparatus of the PSM family of toxins is affected by mupirocin resistance. As an energetically costly activity, this reduction in toxicity masks the fitness costs associated with this resistance mutation, a cost that becomes apparent when toxin production becomes necessary. This hidden fitness cost provides a likely explanation for why this mupirocin-resistance mechanism is not more prevalent, given the widespread use of this antibiotic. CONCLUSIONS: With dwindling pools of antibiotics available for use, information on the fitness consequences of the acquisition of resistance may need to be considered when designing antibiotic prescribing policies. However, this study suggests there are levels of depth that we do not understand, and that holistic, surveillance and functional genomics approaches are required to gain this crucial information.


Assuntos
Antibacterianos/farmacologia , Epistasia Genética , Aptidão Genética/efeitos dos fármacos , Genoma Bacteriano , Isoleucina-tRNA Ligase/genética , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Mupirocina/farmacologia , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Toxinas Bacterianas/biossíntese , Toxinas Bacterianas/genética , Farmacorresistência Bacteriana , Evolução Molecular , Loci Gênicos , Isoleucina-tRNA Ligase/metabolismo , Staphylococcus aureus Resistente à Meticilina/genética , Staphylococcus aureus Resistente à Meticilina/metabolismo , Testes de Sensibilidade Microbiana , Mutação , Proteômica/métodos
10.
Antioxid Redox Signal ; 28(2): 110-130, 2018 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-28793782

RESUMO

AIMS: Deoxyribose-1-phosphate (dRP) is a proangiogenic paracrine stimulus released by cancer cells, platelets, and macrophages and acting on endothelial cells. The objective of this study was to clarify how dRP stimulates angiogenic responses in human endothelial cells. RESULTS: Live cell imaging, electron paramagnetic resonance, pull-down of dRP-interacting proteins, followed by immunoblotting, gene silencing of different NADPH oxidases (NOXs), and their regulatory cosubunits by small interfering RNA (siRNA) transfection, and experiments with inhibitors of the sugar transporter glucose transporter 1 (GLUT1) were utilized to demonstrate that dRP acts intracellularly by directly activating the endothelial NOX2 complex, but not NOX4. Increased reactive oxygen species generation in response to NOX2 activity leads to redox-dependent activation of the transcription factor nuclear factor kappa B (NF-κB), which, in turn, induces vascular endothelial growth factor receptor 2 (VEGFR2) upregulation. Using endothelial tube formation assays, gene silencing by siRNA, and antibody-based receptor inhibition, we demonstrate that the activation of NF-κB and VEGFR2 is necessary for the angiogenic responses elicited by dRP. The upregulation of VEGFR2 and NOX2-dependent stimulation of angiogenesis by dRP were confirmed in excisional wound and Matrigel plug vascularization assays in vivo using NOX2-/- mice. INNOVATION: For the first time, we demonstrate that dRP acts intracellularly and stimulates superoxide anion generation by direct binding and activation of the NOX2 enzymatic complex. CONCLUSIONS: This study describes a novel molecular mechanism underlying the proangiogenic activity of dRP, which involves the sequential activation of NOX2 and NF-κB and upregulation of VEGFR2. Antioxid. Redox Signal. 28, 110-130.


Assuntos
NADPH Oxidase 2/metabolismo , NF-kappa B/metabolismo , Neovascularização Fisiológica/efeitos dos fármacos , Ribosemonofosfatos/farmacologia , Linhagem Celular , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Humanos , Estresse Oxidativo , Espécies Reativas de Oxigênio/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
11.
J Chromatogr A ; 1438: 84-99, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-26896918

RESUMO

This paper proposes a novel multi-residue enantioselective method utilising a CBH (cellobiohydrolase) column, for the analysis of 56 drug biomarkers in wastewater. These are: opioid analgesics, amphetamines, cocaine, heroin, stimulants, anaesthetics, sedatives, anxiolytics, designer drugs, phosphodiesterase-5 (PDE5) inhibitors, amphetamine and methamphetamine drug precursors. Satisfactory enantiomeric separation was obtained for 18 pairs of enantiomers including amphetamine, methamphetamine, MDMA (3,4-methylenedioxy-methamphetamine) and its metabolites HMA (4-hydroxy-3-methoxyamphetamine) and HMMA (4-hydroxy-3-methoxy-methamphetamine), PMA (para-methoxyamphetamine), MDA ((±)- 3,4-methylenedioxyamphetamine) and mephedrone. The method was applied in a one week monitoring study of a large wastewater treatment plant in the UK. Most target drugs were found at quantifiable concentrations in analysed samples. Enantiomeric profiling revealed that amphetamine, methamphetamine and MDMA were found enriched with R-(-)-enantiomers, probably due to their stereoselective metabolism favouring S-(+)-enantiomers. MDA was either enriched with R-(-)- or S-(+)-enantiomer indicating that its presence might be due to either abuse of racemic MDA or abuse of racemic MDMA respectively. Non-racemic enantiomeric fractions were also observed in the case of HMMA and mephedrone suggesting enantioselective metabolism. To the authors' knowledge, this is the first time chiral separation and wastewater profiling of mephedrone, PMA, MDMA and its metabolites HMA and HMMA have been reported.


Assuntos
Biomarcadores/química , Técnicas de Química Analítica/métodos , Cromatografia Líquida , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem , Águas Residuárias/química , Estereoisomerismo
12.
J Mol Biol ; 428(2 Pt A): 385-398, 2016 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-26655848

RESUMO

Interactions between naturally occurring proteins are highly specific, with protein-network imbalances associated with numerous diseases. For designed protein-protein interactions (PPIs), required specificity can be notoriously difficult to engineer. To accelerate this process, we have derived peptides that form heterospecific PPIs when combined. This is achieved using software that generates large virtual libraries of peptide sequences and searches within the resulting interactome for preferentially interacting peptides. To demonstrate feasibility, we have (i) generated 1536 peptide sequences based on the parallel dimeric coiled-coil motif and varied residues known to be important for stability and specificity, (ii) screened the 1,180,416 member interactome for predicted Tm values and (iii) used predicted Tm cutoff points to isolate eight peptides that form four heterospecific PPIs when combined. This required that all 32 hypothetical off-target interactions within the eight-peptide interactome be disfavoured and that the four desired interactions pair correctly. Lastly, we have verified the approach by characterising all 36 pairs within the interactome. In analysing the output, we hypothesised that several sequences are capable of adopting antiparallel orientations. We subsequently improved the software by removing sequences where doing so led to fully complementary electrostatic pairings. Our approach can be used to derive increasingly large and therefore complex sets of heterospecific PPIs with a wide range of potential downstream applications from disease modulation to the design of biomaterials and peptides in synthetic biology.


Assuntos
Biologia Computacional/métodos , Mapeamento de Interação de Proteínas/métodos , Multimerização Proteica , Proteínas/química , Proteínas/metabolismo , Programas de Rastreamento , Ligação Proteica , Eletricidade Estática
13.
Anal Chim Acta ; 882: 112-26, 2015 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-26043098

RESUMO

This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L(-1) (metoprolol) - 1321 ng L(-1) (tramadol) in influent,

Assuntos
Cromatografia Líquida/métodos , Drogas Ilícitas/análise , Preparações Farmacêuticas/análise , Esgotos/química , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Micro-Ondas , Estereoisomerismo
14.
Electrophoresis ; 36(16): 1866-71, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25735831

RESUMO

An electrochemical flow cell with a boron-doped diamond dual-plate microtrench electrode has been developed and demonstrated for hydroquinone flow injection electroanalysis in phosphate buffer pH 7. Using the electrochemical generator-collector feedback detector improves the sensitivity by one order of magnitude (when compared to a single working electrode detector). The diffusion process is switched from an analyte consuming "external" process to an analyte regenerating "internal" process with benefits in selectivity and sensitivity.


Assuntos
Boro/química , Diamante/química , Técnicas Eletroquímicas/instrumentação , Análise de Injeção de Fluxo/instrumentação , Desenho de Equipamento , Retroalimentação , Análise de Injeção de Fluxo/métodos , Hidroquinonas/análise , Oxigênio
15.
Chem Sci ; 6(8): 4978-4985, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29142726

RESUMO

Signal transduction and signal amplification are both important mechanisms used within biological signalling pathways. Inspired by this process, we have developed a signal amplification methodology that utilises the selectivity and high activity of enzymes in combination with the robustness and generality of an organometallic catalyst, achieving a hybrid biological and synthetic catalyst cascade. A proligand enzyme substrate was designed to selectively self-immolate in the presence of the enzyme to release a ligand that can bind to a metal pre-catalyst and accelerate the rate of a transfer hydrogenation reaction. Enzyme-triggered catalytic signal amplification was then applied to a range of catalyst substrates demonstrating that signal amplification and signal transduction can both be achieved through this methodology.

16.
Phys Chem Chem Phys ; 16(35): 18966-73, 2014 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-25092468

RESUMO

Two types of generator-collector electrode systems, (i) a gold-gold interdigitated microband array and (ii) a gold-gold dual-plate microtrench, are compared for nitrobenzene electroanalysis in aerated aqueous 0.1 M NaOH. The complexity of the nitrobenzene reduction in conjunction with the presence of ambient levels of oxygen in the analysis solution provide a challenging problem in which feedback-amplified generator-collector steady state currents provide the analytical signal. In contrast to the more openly accessible geometry of the interdigitated array electrode, where the voltammetric response for nitrobenzene is less well-defined and signals drift, the voltammetric response for the cavity-like microtrench electrode is stable and readily detectable at 1 µM level. Both types of electrode show oxygen-enhanced low concentration collector current responses due to additional feedback via reaction intermediates. The observations are rationalised in terms of a "cavity transport coefficient" which is beneficial in the dual-plate microtrench, where oxygen interference effects are suppressed and the analytical signal is amplified and stabilised.


Assuntos
Técnicas Eletroquímicas , Nitrobenzenos/análise , Calibragem , Técnicas Eletroquímicas/normas , Eletrodos , Ferrocianetos/química , Ouro/química , Modelos Teóricos , Nitrobenzenos/normas , Oxirredução , Hidróxido de Sódio/química
17.
Water Res ; 47(15): 5708-18, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23886544

RESUMO

Here presented for the first time is the enantioselective biodegradation of amphetamine and methamphetamine in river microcosm bioreactors. The aim of this investigation was to test the hypothesis that mechanisms governing the fate of amphetamine and methamphetamine in the environment are mostly stereoselective and biological in nature. Several bioreactors were studied over the duration of 15 days (i) in both biotic and abiotic conditions, (ii) in the dark or exposed to light and (iii) in the presence or absence of suspended particulate matter. Bioreactor samples were analysed using SPE-chiral-LC-(QTOF)MS methodology. This investigation has elucidated the fundamental mechanism for degradation of amphetamine and methamphetamine as being predominantly biological in origin. Furthermore, stereoselectivity and changes in enantiomeric fraction (EF) were only observed under biotic conditions. Neither amphetamine nor methamphetamine appeared to demonstrate adsorption to suspended particulate matter. Our experiments also demonstrated that amphetamine and methamphetamine were photo-stable. Illicit drugs are present in the environment at low concentrations but due to their pseudo-persistence and non-racemic behaviour, with two enantiomers revealing significantly different potency (and potentially different toxicity towards aquatic organisms) the risk posed by illicit drugs in the environment should not be under- or over-estimated. The above results demonstrate the need for re-evaluation of the procedures utilised in environmental risk assessment, which currently do not recognise the importance of the phenomenon of chirality in pharmacologically active compounds.


Assuntos
Anfetamina/metabolismo , Biodegradação Ambiental , Metanfetamina/metabolismo , Rios/microbiologia , Anfetamina/química , Metanfetamina/química , Estereoisomerismo
18.
Rapid Commun Mass Spectrom ; 22(12): 1779-86, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18470872

RESUMO

Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns. The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS. The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers.


Assuntos
Bases de Dados Factuais , Íons , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Calibragem , Cromatografia Líquida , Peso Molecular , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
19.
Rapid Commun Mass Spectrom ; 20(14): 2074-80, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16773668

RESUMO

Liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS) has been used successfully for the characterization of biomolecules in proteomics in the last few years. This methodology relied largely on the use of reversed-phase chromatography, in particular C18-based resins, which are suitable for separation of peptides. Here we show that polymeric [polystyrene divinylbenzene] monolithic columns can be used to separate peptide mixtures faster and at a higher resolution. For 500 fmol bovine serum albumin, up to 68% sequence coverage and Mascot Mowse scores of >2000 were obtained using a 9 min gradient on a monolithic column coupled to an ion trap mass spectrometer with ultra-fast MS/MS scan rates. In order to achieve similar results using C18 columns, it was necessary to extend gradient times to 30 min. In addition, we demonstrate the utility of this approach for the analysis of whole Escherichia coli cell lysates by one-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (1D-SDS-PAGE) in combination with LC/MS/MS using 4 min gradients on monolithic columns. Our results indicate higher throughput capabilities of monolithic columns (3-fold gain in time or more) for conventional proteomics applications, such as protein identification and high sequence coverage usually required for detection of post-translational modifications (PTMs). Further optimization of sensitivity and quality of sequence information is discussed, in particular when combined with mass spectrometers that have very fast MS-MS/MS switching and scanning capabilities.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Mapeamento de Peptídeos , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Bovinos , Cromatografia Líquida de Alta Pressão/métodos , Eletroforese em Gel de Poliacrilamida , Escherichia coli/química , Escherichia coli/metabolismo , Microquímica/instrumentação , Microquímica/métodos , Proteômica/instrumentação , Sensibilidade e Especificidade , Albumina Sérica/análise , Fatores de Tempo
20.
J Lipid Res ; 47(7): 1588-96, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16632799

RESUMO

It is now apparent that each of the known, naturally occurring polyphosphoinositides, the phosphatidylinositol monophosphates (PtdIns3P, PtdIns4P, PtdIns5P), phosphatidylinositol bisphosphates [PtdIns(3,4)P(2), PtdIns(3,5)P(2), PtdIns(4,5)P(2)], and phosphatidylinositol trisphosphate [PtdIns(3,4,5)P(3)], have distinct roles in regulating many cellular events, including intracellular signaling, migration, and vesicular trafficking. Traditional identification techniques require [(32)P]inorganic phosphate or [(3)H]inositol radiolabeling, acidified lipid extraction, deacylation, and ion-exchange head group separation, which are time-consuming and not suitable for samples in which radiolabeling is impractical, thus greatly restricting the study of these lipids in many physiologically relevant systems. Thus, we have developed a novel, high-efficiency, buffered citrate extraction methodology to minimize acid-induced phosphoinositide degradation, together with a high-sensitivity liquid chromatography-mass spectrometry (LC-MS) protocol using an acetonitrile-chloroform-methanol-water-ethylamine gradient with a microbore silica column that enables the identification and quantification of all phosphoinositides in a sample. The liquid chromatograph is sufficient to resolve PtdInsP(3) and PtdInsP(2) regioisomers; however, the PtdInsP regioisomers require a combination of LC and diagnostic fragmentation to MS(3). Data are presented using this approach for the analysis of phosphoinositides in human platelet and yeast samples.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Fosfatidilinositóis/análise , Plaquetas/química , Cromatografia Líquida/estatística & dados numéricos , Humanos , Espectrometria de Massas/estatística & dados numéricos , Fosfatidilinositóis/sangue , Fosfatidilinositóis/química , Saccharomyces cerevisiae/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...