Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Diabetes Care ; 43(1): 44-52, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31484666

RESUMO

OBJECTIVE: The HypoCOMPaSS study was designed to test the hypothesis that successful avoidance of biochemical hypoglycemia without compromising overall glycemic control would restore sufficient hypoglycemia awareness to prevent recurrent severe hypoglycemia in the majority of participants with established type 1 diabetes. Before starting the study, we planned to investigate associations between baseline characteristics and recurrent severe hypoglycemia over 2 years' follow-up. RESEARCH DESIGN AND METHODS: A total of 96 adults with type 1 diabetes and impaired awareness of hypoglycemia participated in a 24-week 2 × 2 factorial randomized controlled trial comparing insulin delivery and glucose monitoring modalities, with the goal of rigorous biochemical hypoglycemia avoidance. The analysis included 71 participants who had experienced severe hypoglycemia in the 12-month prestudy with confirmed absence (complete responder) or presence (incomplete responder) of severe hypoglycemia over 24 months' follow-up. RESULTS: There were 43 (61%) complete responders and 28 (39%) incomplete responders experiencing mean ± SD 1.5 ± 1.0 severe hypoglycemia events/person-year. At 24 months, incomplete responders spent no more time with glucose ≤3 mmol/L (1.4 ± 2.1% vs. 3.0 ± 4.8% for complete responders; P = 0.26), with lower total daily insulin dose (0.45 vs. 0.58 units/24 h; P = 0.01) and greater impairment of hypoglycemia awareness (Clarke score: 3.8 ± 2.2 vs. 2.0 ± 1.9; P = 0.01). Baseline severe hypoglycemia rate (16.9 ± 16.3 vs. 6.4 ± 10.8 events/person-year; P = 0.002) and fear of hypoglycemia were higher in incomplete responders. Peripheral neuropathy was more prevalent in incomplete responders (11 [39%] vs. 2 [4.7%]; P < 0.001) with a trend toward increased autonomic neuropathy. CONCLUSIONS: Recurrent severe hypoglycemia was associated with higher preintervention severe hypoglycemia rate, fear of hypoglycemia, and concomitant neuropathy.


Assuntos
Conscientização , Transtornos Cognitivos/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Insulina/efeitos adversos , Adolescente , Adulto , Idoso , Glicemia/análise , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Transtornos Cognitivos/complicações , Transtornos Cognitivos/diagnóstico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico , Feminino , Humanos , Hipoglicemia/psicologia , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
3.
Diabetes Care ; 41(8): 1600-1607, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29661916

RESUMO

OBJECTIVE: Severe hypoglycemia is a feared complication of type 1 diabetes; yet, few trials have targeted prevention using optimized self-management (educational, therapeutic, and technological support). We aimed to investigate whether improved awareness and reduced severe hypoglycemia, achieved during an intensive randomized clinical trial (RCT), were sustained after return to routine care. RESEARCH DESIGN AND METHODS: Ninety-six adults with type 1 diabetes (29 ± 12 years' duration) and impaired awareness of hypoglycemia at five U.K. tertiary referral diabetes centers were recruited into a 24-week 2 × 2 factorial RCT (HypoCOMPaSS). Participants were randomized to pump (continuous subcutaneous insulin infusion [CSII]) or multiple daily injections (MDIs) and real-time continuous glucose monitoring (RT-CGM) or self-monitoring of blood glucose (SMBG), with equal education/attention to all groups. At 24 weeks, participants returned to routine care with follow-up until 24 months, including free choice of MDI/CSII; RT-CGM vs. SMBG comparison continued to 24 months. Primary outcome was mean difference (baseline to 24 months [between groups]) in hypoglycemia awareness. RESULTS: Improvement in hypoglycemia awareness was sustained (Gold score at baseline 5.1 ± 1.1 vs. 24 months 3.7 ± 1.9; P < 0.0001). Severe hypoglycemia rate was reduced from 8.9 ± 12.8 episodes/person-year over the 12 months prestudy to 0.4 ± 0.8 over 24 months (P < 0.0001). HbA1c improved (baseline 8.2 ± 3.2% [66 ± 12 mmol/mol] vs. 24 months 7.7 ± 3.1% [61 ± 10 mmol/mol]; P = 0.003). Improvement in treatment satisfaction and reduced fear of hypoglycemia were sustained. There were no significant differences between interventions at 24 months. CONCLUSIONS: Optimized insulin replacement and glucose monitoring underpinned by hypoglycemia-focused structured education should be provided to all with type 1 diabetes complicated by impaired awareness of hypoglycemia.


Assuntos
Conscientização , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Insulina/efeitos adversos , Adulto , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Seguimentos , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/sangue , Hipoglicemia/psicologia , Injeções , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
4.
Diabetes ; 66(5): 1322-1333, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28137792

RESUMO

Hypoglycemia is associated with increased cardiovascular mortality in trials of intensive therapy in type 2 diabetes mellitus (T2DM). We previously observed an increase in arrhythmias during spontaneous prolonged hypoglycemia in patients with T2DM. We examined changes in cardiac autonomic function and repolarization during sustained experimental hypoglycemia. Twelve adults with T2DM and 11 age- and BMI-matched control participants without diabetes underwent paired hyperinsulinemic clamps separated by 4 weeks. Glucose was maintained at euglycemia (6.0 mmol/L) or hypoglycemia (2.5 mmol/L) for 1 h. Heart rate, blood pressure, and heart rate variability were assessed every 30 min and corrected QT intervals and T-wave morphology every 60 min. Heart rate initially increased in participants with T2DM but then fell toward baseline despite maintained hypoglycemia at 1 h accompanied by reactivation of vagal tone. In control participants, vagal tone remained depressed during sustained hypoglycemia. Participants with T2DM exhibited greater heterogeneity of repolarization during hypoglycemia as demonstrated by T-wave symmetry and principal component analysis ratio compared with control participants. Epinephrine levels during hypoglycemia were similar between groups. Cardiac autonomic regulation during hypoglycemia appears to be time dependent. Individuals with T2DM demonstrate greater repolarization abnormalities for a given hypoglycemic stimulus despite comparable sympathoadrenal responses. These mechanisms could contribute to arrhythmias during clinical hypoglycemic episodes.


Assuntos
Arritmias Cardíacas/fisiopatologia , Sistema Nervoso Autônomo/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Diabetes Mellitus Tipo 2/fisiopatologia , Frequência Cardíaca/efeitos dos fármacos , Coração/efeitos dos fármacos , Hipoglicemia/fisiopatologia , Hipoglicemiantes/farmacologia , Insulina/farmacologia , Adulto , Arritmias Cardíacas/induzido quimicamente , Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea/fisiologia , Eletrocardiografia , Epinefrina/sangue , Feminino , Técnica Clamp de Glucose , Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Hipoglicemia/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Nervo Vago/efeitos dos fármacos , Nervo Vago/fisiopatologia
5.
Artigo em Inglês | MEDLINE | ID: mdl-27047664

RESUMO

UNLABELLED: Secondary amenorrhoea and galactorrhoea represent a common endocrine presentation. We report a case of an oestrogen-producing juvenile granulosa cell tumour (JGCT) of the ovary in a 16-year-old post-pubertal woman with hyperprolactinaemia amenorrhoea and galactorrhoea which resolved following surgical resection of the tumour. This patient presented with a 9-month history of secondary amenorrhoea and a 2-month history of galactorrhoea. Elevated serum prolactin at 7081 mIU/l and suppressed gonadotropins (LH <0.1 U/l; FSH <0.1 U/l) were detected. Serum oestradiol was significantly elevated at 7442 pmol/l with undetectable ß-human chorionic gonadotropin. MRI showed a bulky pituitary with no visible adenoma. MRI of the abdomen showed a 4.8 cm mass arising from the right ovary with no evidence of metastatic disease. Serum inhibin B was elevated at 2735 ng/l. A right salpingo-oophorectomy was performed, and histology confirmed the diagnosis of a JGCT, stage International Federation of Gynaecology and Obstetrics 1A. Immunohistochemical staining for prolactin was negative. Post-operatively, oestrogen and prolactin levels were normalised, and she subsequently had a successful pregnancy. In summary, we present a case of an oestrogen-secreting JGCT with hyperprolactinaemia manifesting clinically with galactorrhoea and secondary amenorrhoea. We postulate that observed hyperprolactinaemia was caused by oestrogenic stimulation of pituitary lactotroph cells, a biochemical state analogous to pregnancy. To the best of our knowledge, this is the first report of hyperprolactinaemia as a result of excessive oestrogen production in the context of a JGCT. LEARNING POINTS: Hyperprolactinaemia with bilateral galactorrhoea and secondary amenorrhoea has a wide differential diagnosis and is not always caused by a prolactin secreting pituitary adenoma.Significantly elevated serum oestradiol levels in the range seen in this case, in the absence of pregnancy, are indicative of an oestrogen-secreting tumour.JGCTs are rare hormonally active ovarian neoplasms mostly secreting steroid hormones.Serum inhibin can be used as a granulosa cell-specific tumour marker.JGCTs have an excellent prognosis in the early stages of the disease.

8.
Lancet ; 385 Suppl 1: S96, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-26312919

RESUMO

BACKGROUND: The closed-loop system (artificial pancreas) delivers insulin in a glucose-responsive manner by the use of a control algorithm that automatically directs insulin delivery, based on real-time sensor glucose concentrations. Results from hospital-based studies have shown improved overnight glucose control and reduced risk of hypoglycaemia in type 1 diabetes. We aimed to assess whether unsupervised closed-loop systems can provide a realistic treatment option in patients with type 1 diabetes. METHODS: We combined data from two open-label, phase 2, randomised, cross-over, unsupervised home trials of people with type 1 diabetes, one in 24 adults (mean age 43 years [SD 12], HbA1c 8·0% [0·9]) and the other in 16 adolescents (15·6 [3·6], 8·1 [0·8]). In each trial, after training on study devices, participants were allocated to two periods of sensor-augmented pump therapy either with or without overnight closed loop that used a model predictive control algorithm to direct insulin delivery. Allocation sequence was done with a computer-generated random code. Each period lasted 4 weeks in adults and 3 weeks in adolescents. Primary outcome for both trials was time when sensor glucose was in the target range (3·9-8·0 mmol/L). Analysis was by intention to treat. Participants (or parents) gave written informed consent. The trials are registered with ClinicalTrials.gov, numbers NCT01440140 and NCT01221467. FINDINGS: Closed loop was started by participants on their own volition on 866 (89%) of 978 nights. The proportion of time when sensor glucose was in the target range between 0000 h and 0800 h was increased by a mean of 18·4% (95% CI 13·5-23·4, p<0·0001) during closed loop compared with no closed loop. Closed loop significantly reduced mean overnight sensor glucose by 0·9 mmol/L (95% CI 0·4-1·3, p=0·0001), and reduced the proportion of time when sensor glucose values were suggestive of hyperglycaemia (>8·0 mmol/L) (15·9%, 10·7-21·0; p<0·0001) and hypoglycaemia (<3·9 mmol/L) (median 0·9, IQR 0·2-2·2; p=0·014). Lower mean overnight glucose was associated with increased overnight insulin delivery (p<0·0001) without changing total daily insulin amount (p=0·84). INTERPRETATION: Extended use of overnight closed loop at home without supervision is feasible in adults and adolescents with type 1 diabetes. Clinically significant reduction in overnight glucose was observed accompanied by reduced time spent by patients in hypoglycaemia. To our knowledge, such combined effect has not been documented with any other means of intensified conventional insulin delivery. Longer term studies are warranted to assess its clinical potential. FUNDING: Diabetes UK, Juvenile Diabetes Research Foundation, NIHR Cambridge Biomedical Research Centre.

9.
Diabetes Technol Ther ; 17(11): 801-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26241693

RESUMO

OBJECTIVES: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a continuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator(®) II CGM (Abbott Diabetes Care, Alameda, CA) during three unsupervised, randomized, open-label, crossover home CL studies. MATERIALS AND METHODS: Paired CGM and capillary glucose values (10,597 pairs) were collected from 57 participants with type 1 diabetes (41 adults [mean±SD age, 39±12 years; mean±SD hemoglobin A1c, 7.9±0.8%] recruited at five centers and 16 adolescents [mean±SD age, 15.6±3.6 years; mean±SD hemoglobin A1c, 8.1±0.8%] recruited at two centers). Numerical accuracy was assessed by absolute relative difference (ARD) and International Organization for Standardization (ISO) 15197:2013 15/15% limits, and clinical accuracy was assessed by Clarke error grid analysis. RESULTS: Total duration of sensor use was 2,002 days (48,052 h). Overall sensor accuracy for the capillary glucose range (1.1-27.8 mmol/L) showed mean±SD and median (interquartile range) ARD of 14.2±15.5% and 10.0% (4.5%, 18.4%), respectively. Lowest mean ARD was observed in the hyperglycemic range (9.8±8.8%). Over 95% of pairs were in combined Clarke error grid Zones A and B (A, 80.1%, B, 16.2%). Overall, 70.0% of the sensor readings satisfied ISO criteria. Mean ARD was consistent (12.3%; 95% of the values fall within ±3.7%) and not different between participants (P=0.06) within the euglycemic and hyperglycemic range, when CL is actively modulating insulin delivery. CONCLUSIONS: Consistent accuracy of the CGM within the euglycemic-hyperglycemic range using the Freestyle Navigator II was observed and supports its use in home CL studies. Our results may contribute toward establishing normative CGM performance criteria for unsupervised home use of CL.


Assuntos
Automonitorização da Glicemia/normas , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Adolescente , Adulto , Automonitorização da Glicemia/instrumentação , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/diagnóstico , Hipoglicemia/tratamento farmacológico , Hipoglicemia/etiologia , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/normas , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Condições Sociais , Comunicação para Apreensão de Informação , Fatores de Tempo
11.
Lancet Diabetes Endocrinol ; 2(9): 701-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24943065

RESUMO

BACKGROUND: Closed-loop insulin delivery is a promising option to improve glycaemic control and reduce the risk of hypoglycaemia. We aimed to assess whether overnight home use of automated closed-loop insulin delivery would improve glucose control. METHODS: We did this open-label, multicentre, randomised controlled, crossover study between Dec 1, 2012, and Dec 23, 2014, recruiting patients from three centres in the UK. Patients aged 18 years or older with type 1 diabetes were randomly assigned to receive 4 weeks of overnight closed-loop insulin delivery (using a model-predictive control algorithm to direct insulin delivery), then 4 weeks of insulin pump therapy (in which participants used real-time display of continuous glucose monitoring independent of their pumps as control), or vice versa. Allocation to initial treatment group was by computer-generated permuted block randomisation. Each treatment period was separated by a 3-4 week washout period. The primary outcome was time spent in the target glucose range of 3·9-8·0 mmol/L between 0000 h and 0700 h. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01440140. FINDINGS: We randomly assigned 25 participants to initial treatment in either the closed-loop group or the control group, patients were later crossed over into the other group; one patient from the closed-loop group withdrew consent after randomisation, and data for 24 patients were analysed. Closed loop was used over a median of 8·3 h (IQR 6·0-9·6) on 555 (86%) of 644 nights. The proportion of time when overnight glucose was in target range was significantly higher during the closed-loop period compared to during the control period (mean difference between groups 13·5%, 95% CI 7·3-19·7; p=0·0002). We noted no severe hypoglycaemic episodes during the control period compared with two episodes during the closed-loop period; these episodes were not related to closed-loop algorithm instructions. INTERPRETATION: Unsupervised overnight closed-loop insulin delivery at home is feasible and could improve glucose control in adults with type 1 diabetes. FUNDING: Diabetes UK.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/efeitos dos fármacos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Pâncreas Artificial , Adulto , Algoritmos , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Reino Unido/epidemiologia
12.
Diabetes Care ; 37(8): 2114-22, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24854041

RESUMO

OBJECTIVE: To determine whether impaired awareness of hypoglycemia (IAH) can be improved and severe hypoglycemia (SH) prevented in type 1 diabetes, we compared an insulin pump (continuous subcutaneous insulin infusion [CSII]) with multiple daily injections (MDIs) and adjuvant real-time continuous glucose monitoring (RT) with conventional self-monitoring of blood glucose (SMBG). RESEARCH DESIGN AND METHODS: A 24-week 2 × 2 factorial randomized controlled trial in adults with type 1 diabetes and IAH was conducted. All received comparable education, support, and congruent therapeutic targets aimed at rigorous avoidance of biochemical hypoglycemia without relaxing overall control. Primary end point was between-intervention difference in 24-week hypoglycemia awareness (Gold score). RESULTS: A total of 96 participants (mean diabetes duration 29 years) were randomized. Overall, biochemical hypoglycemia (≤3.0 mmol/L) decreased (53 ± 63 to 24 ± 56 min/24 h; P = 0.004 [t test]) without deterioration in HbA1c. Hypoglycemia awareness improved (5.1 ± 1.1 to 4.1 ± 1.6; P = 0.0001 [t test]) with decreased SH (8.9 ± 13.4 to 0.8 ± 1.8 episodes/patient-year; P = 0.0001 [t test]). At 24 weeks, there was no significant difference in awareness comparing CSII with MDI (4.1 ± 1.6 vs. 4.2 ± 1.7; difference 0.1; 95% CI -0.6 to 0.8) and RT with SMBG (4.3 ± 1.6 vs. 4.0 ± 1.7; difference -0.3; 95% CI -1.0 to 0.4). Between-group analyses demonstrated comparable reductions in SH, fear of hypoglycemia, and insulin doses with equivalent HbA1c. Treatment satisfaction was higher with CSII than MDI (32 ± 3 vs. 29 ± 6; P = 0.0003 [t test]), but comparable with SMBG and RT (30 ± 5 vs. 30 ± 5; P = 0.79 [t test]). CONCLUSIONS: Hypoglycemia awareness can be improved and recurrent SH prevented in long-standing type 1 diabetes without relaxing HbA1c. Similar biomedical outcomes can be attained with conventional MDI and SMBG regimens compared with CSII/RT, although satisfaction was higher with CSII.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Adolescente , Adulto , Idoso , Conscientização , Glicemia/metabolismo , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/psicologia , Esquema de Medicação , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/sangue , Hipoglicemia/prevenção & controle , Hipoglicemia/psicologia , Infusões Subcutâneas , Injeções , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Recidiva , Adulto Jovem
13.
Diabetes Care ; 36(12): 4063-70, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24130355

RESUMO

OBJECTIVE: Impaired awareness of hypoglycemia (IAH) and defective counterregulation significantly increase severe hypoglycemia risk in type 1 diabetes (T1D). We evaluated restoration of IAH/defective counterregulation by a treatment strategy targeted at hypoglycemia avoidance in adults with T1D with IAH (Gold score ≥4) participating in the U.K.-based multicenter HypoCOMPaSS randomized controlled trial. RESEARCH DESIGN AND METHODS: Eighteen subjects with T1D and IAH (mean ± SD age 50 ± 9 years, T1D duration 35 ± 10 years, HbA1c 8.1 ± 1.0% [65 ± 10.9 mmol/mol]) underwent stepped hyperinsulinemic-hypoglycemic clamp studies before and after a 6-month intervention. The intervention comprised the HypoCOMPaSS education tool in all and randomized allocation, in a 2 × 2 factorial study design, to multiple daily insulin analog injections or continuous subcutaneous insulin infusion therapy and conventional glucose monitoring or real-time continuous glucose monitoring. Symptoms, cognitive function, and counterregulatory hormones were measured at each glucose plateau (5.0, 3.8, 3.4, 2.8, and 2.4 mmol/L), with each step lasting 40 min with subjects kept blinded to their actual glucose value throughout clamp studies. RESULTS: After intervention, glucose concentrations at which subjects first felt hypoglycemic increased (mean ± SE from 2.6 ± 0.1 to 3.1 ± 0.2 mmol/L, P = 0.02), and symptom and plasma metanephrine responses to hypoglycemia were higher (median area under curve for symptoms, 580 [interquartile range {IQR} 420-780] vs. 710 [460-1,260], P = 0.02; metanephrine, 2,412 [-3,026 to 7,279] vs. 5,180 [-771 to 11,513], P = 0.01). Glycemic threshold for deterioration of cognitive function measured by four-choice reaction time was unchanged, while the color-word Stroop test showed a degree of adaptation. CONCLUSIONS: Even in long-standing T1D, IAH and defective counterregulation may be improved by a clinical strategy aimed at hypoglycemia avoidance.


Assuntos
Conscientização , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/metabolismo , Hipoglicemia/prevenção & controle , Hipoglicemia/psicologia , Insulina/administração & dosagem , Adulto , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/psicologia , Relação Dose-Resposta a Droga , Feminino , Técnica Clamp de Glucose , Humanos , Hipoglicemia/sangue , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...