Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Int J Hyperthermia ; 35(1): 216-225, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30300014

RESUMO

PURPOSE: Comparison between different thermal ablation systems for thyroid nodules regarding their different procedural characteristics such as treatment-time, number of shots and energy transmission in the context of their clinical performance such as complication rate and volume reduction after three months. METHODS: A total of 60 patients with 65 nodules underwent thermal ablation of thyroid nodules with either microwave ablation (MWA) (9 male, 15 female and mean age 57 ± 13 years) or radiofrequency ablation (RFA) (12 male, 24 female and mean age 54 ± 12 years). RESULTS: Mean initial volume (MWA: 23.90 ± 17.35 ml; RFA: 29.44 ± 30.09 ml), energy transmission (MWA: 13.56 ± 10.17 kJ; RFA: 15.12 ± 13.45 kJ), energy transmission per ml (MWA: 0.85 ± 1.01 kJ/ml; RFA: 0.65 ± 0.32 kJ/ml), power (MWA: 22.69 ± 12.32 J/s; RFA: 20.97 ± 7.86 J/s) and duration of ablation (MWA: 618 ± 304 s; RFA: 695 ± 463 s) were not statistically different (p > .05). MWA required significantly less shots (MWA: 3 ± 1; RFA: 6 ± 3) than RFA (p < .05). At three-months follow-up a significant mean nodular volume reduction of 53.54 ± 15.40% after MWA and 51.21 ± 16.58% after RFA (p < .05) was measured. However, mean nodular volume reduction was not significantly different between both systems (p > .05). One patient treated by MWA reported a transient Horner's syndrome, which recovered without any further treatment. Major complications such as nodule rupture, infection or persisting nerve injuries did not occur. CONCLUSION: Both systems are suitable to treat thyroid nodules and show no significant difference in the duration of application, energy transmission and volume reduction. However, MWA requires less shots to treat the whole nodule.


Assuntos
Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nódulo da Glândula Tireoide/patologia
2.
Eur J Radiol Open ; 3: 259-263, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27844041

RESUMO

PURPOSE: To determine the value of the 2D multiple-echo data image combination (MEDIC) sequence relative to the short-tau inversion recovery (STIR) sequence regarding the depiction of chondral lesions in the patellofemoral joint. MATERIALS AND METHODS: During a period of 6 month patients with acute pain at the anterior aspect of the knee, joint effusion and suspected chondral lesion defect in the patellofemoral joint underwent MRI including axial MEDIC and STIR imaging. Patients with chondral lesions in the patellofemoral joint on at least one sequence were included. The MEDIC and STIR sequence were quantitatively compared regarding the patella cartilage-to-effusion contrast-to-noise ratio (CNR) and qualitatively regarding the depiction of chondral lesions independently scored by two radiologists on a 3-point scale (1 = not depicted; 2 = blurred depicted; 3 = clearly depicted) using the Wilcoxon-Mann-Whitney-Test. For the analysis of inter-observer agreement the Cohen's Weighted Kappa test was used. RESULTS: 30 of 58 patients (male: female, 21:9; age: 44 ± 12 yrs) revealed cartilage lesions (fissures, n = 5 including fibrillation; gaps, n = 15; delamination, n = 7; osteoarthritis, n = 3) and were included in this study. The STIR-sequence was significantly (p < 0.001) superior to the MEDIC-sequence regarding both, the patella cartilage-to-effusion CNR (mean CNR: 232 ± 61 vs. 40 ± 16) as well as the depiction of chondral lesion (mean score: 2.83 ± 0.4 vs. 1.75 ± 0.7) with substantial inter-observer agreement in the rating of both sequences (κ = 0.76-0.89). CONCLUSION: For the depiction of chondral lesions in the patellofemoral joint, the axial STIR-sequence should be chosen in preference to the axial MEDIC-sequence.

3.
Eur J Radiol ; 85(8): 1432-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27423684

RESUMO

OBJECTIVES: To evaluate the influence of endorectal coil (ERC) regarding spectral quality and diagnostic suitability and diagnostic performance in 3.0T 1H-magnetic resonance spectroscopy imaging (MRSI) compared to 1.5T MRSI. MATERIALS AND METHODS: The study was approved by the Institutional Review Board. MRSI of the prostate was performed on 19 patients at 1.5T with ERC (protocol 1), at 3.0T with a disabled ERC (protocol 2) and at 3.0T with ERC (protocol 3). Age, weight, body size, body-mass-index, prostate volume, time between measurements, diagnostic suitability of spectra, histopathological results after biopsy of cancer suspect lesions (CSL), sensitivity and specificity were evaluated. Signal-to-noise ratio (SNR) was calculated and compared using semiparametrical multiple Conover-comparisons. Correlations between SNR and prostate volume and BMI were indicated using Pearson correlation coefficient. Distribution of SNR was evaluated for prostate quadrants. RESULTS: Diagnostic suitable spectra were achieved in 76 % (protocol 1, 100% in CSL), 32 % (protocol 2, 59% in CSL) and 50 % (protocol 3, 80% in CSL) of the voxels. SNR was significantly higher in protocol 3 compared to protocol 2 and 1 (93,729 vs. 27,836 vs. 32,897, p<0.0001) with significant difference between protocol 2 and 1 (p<0.023). Highest SNR was achieved in the dorsal prostate (protocols 1 and 3; p<0.0001). Sensitivity at 3.0T was higher with use of ERC. Specificity was highest at 1.5T with ERC. CONCLUSION: The ERC improves the diagnostic suitability and the SNR in MRSI at 3.0T. Less voxels at 3.0T with disabled ERC are suitable for diagnosis compared to 1.5T with ERC. MRSI at 3.0T with ERC shows the highest SNR. SNR in dorsal quadrants of the prostate was higher using ERC.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Biópsia , Índice de Massa Corporal , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia , Sensibilidade e Especificidade , Razão Sinal-Ruído
4.
Int J Hyperthermia ; 32(5): 511-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27126512

RESUMO

Purpose The aim of this study was to evaluate the decrease of benign thyroid nodules after bipolar radiofrequency ablation (RFA) in a 3-month follow-up using a multiple overlapping shot technique ('MOST'). Methods A total of 18 patients with 20 symptomatic benign thyroid nodules (17 cold nodules, 3 hyperfunctioning nodules) were treated in one single session by bipolar RFA. Bipolar ablation was performed using MOST. The nodule volumes were measured prior to ablation and 3 months after the procedure using ultrasound. The population consisted of either solid (>80% solid tissue within the volume of interest), complex, or cystic nodules (<20% solid tissue within the volume of interest). Results Bipolar RFA resulted in a highly significant (p < 0.0001) decrease of nodule volume (ΔV), median 5.3 mL (range 0.13-43.1 mL), corresponding to a relative reduction in mean of 56 ± 17.9%. Median initial volume was 8 mL (range 0.48-62 mL); 3 months after ablation a median volume of 2.3 mL (range 0.3-32 mL) was measured. Nodule growth ≥50% occurred in 70% (14 nodules). At the follow-up no complications such as infections, persisting pain, nerve injuries or immunogen stimulation occurred. Patients with cold nodules (15) remained euthyroid, with hyperfunctioning nodules either euthyroid (2) or latent hypofunctional (1). Conclusion The use of bipolar RFA is an effective, safe and suitable thermoablative technique to treat benign thyroid nodules. Combined with the multiple overlapping shot technique it allows sufficient ablation.


Assuntos
Ablação por Cateter/métodos , Nódulo da Glândula Tireoide/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia , Adulto Jovem
5.
Eur J Med Res ; 21: 2, 2016 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-26749430

RESUMO

BACKGROUND: Focal colorectal uptake in (18)FDG-PET/CT may be associated with a malignancy and can be quantified. This provides the basis for an automatic trigger threshold above which cases are flagged for colonoscopic evaluation and below which for individual assessment. PURPOSE: To determine the lowest maximum standard uptake (SUVmax) in colorectal cancer that could be used as a threshold to trigger endoscopic evaluation and to evaluate whether the SUVmax needs to be further normalised to a priori known extrinsic factors. METHODS: The SUVmax was measured in 54 colorectal carcinomas and correlated with gender, age, blood glucose level, injected activity, body mass index and time to scan using t test or correlation coefficients (Pearson or Spearman, according to distribution). RESULTS: There was no correlation between SUVmax and any of the extrinsic factors mentioned above. The lowest SUVmax value was 5 [mean ± SD (range): 11.1 ± 4.8 (5.0-24.6)]. CONCLUSION: In contrast to most other screening techniques, semi-automation in colorectal screening seems possible with PET/CT. This opens the door for further study into the feasibility of automated screening. Independent from extrinsic factors, an SUVmax ≥5.0 in a focal colorectal uptake in (18)FDG-PET/CT should automatically trigger for endoscopic evaluation, if not contraindicated. Cases with SUVmax <5 should be assessed individually before referral for endoscopy. Thus, more interpretation time could be spent on those cases with a lower uptake and more ambiguous diagnosis.


Assuntos
Neoplasias Colorretais/diagnóstico , Fluordesoxiglucose F18/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo/diagnóstico por imagem , Colo/metabolismo , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Feminino , Fluordesoxiglucose F18/normas , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
AJR Am J Roentgenol ; 205(3): 618-22, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295650

RESUMO

OBJECTIVE: The purpose of this study was to determine whether iterative reconstruction improves the quality of cranial CT (CCT) images of stroke patients. MATERIALS AND METHODS: Fifty-one CCT studies of patients with infarction performed with either a low (260 mAs; n = 21) or standard (340 mAs; n = 30) dose were reconstructed with both filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with five strength levels (S1-S5). The resulting six image sets (one FBP and one each for SAFIRE levels S1-S5) were rated separately by two blinded radiologists in terms of conspicuity of infarcted areas on a 5-point scale. Noise and infarct-to-normal brain as well as medullary-to-cortical contrast-to-noise ratios (CNRs) were measured. Ratings, noise, and CNRs were intraindividually compared within the same dose group (Fisher exact test) and interindividually between the different dose groups (Wilcoxon-Mann-Whitney U test). RESULTS: The strength level S4 showed the best conspicuity of infarcted areas. Compared with FBP, SAFIRE S4 statistically significantly (p < 0.01) reduced noise and improved CNRs without statistically significant differences in all subjective and objective criteria (p > 0.01) when the dose was reduced. Patients examined with a 260-mAs low-dose were exposed to a statistically significantly lower dose (1.77 vs 2.33 mSv; p < 0.01). CONCLUSION: Iterative reconstruction (SAFIRE at strength level S4) leads to increased subjective and objective image quality in CCT and allows dose reduction (-24%) without losses in the demarcation of ischemic lesions.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Doses de Radiação , Razão Sinal-Ruído
7.
Radiol Med ; 120(12): 1112-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981379

RESUMO

OBJECTIVES: To compare radiation exposure and image quality of second-generation 128-slice dual-source CT (DSCT) coronary angiography (cCTA) protocols. MATERIALS AND METHODS: We retrospectively analyzed data from four groups with 25 patients, each examined by one of the following DSCT cCTA protocols: prospectively ECG-gated high-pitch (group 1) or sequential (group 2) acquisition, retrospectively ECG-gated acquisition in dual-energy (DECT, group 3) or dual-source (group 4) mode. CT dose index volume, dose length product, estimated radiation dose, contrast-to-noise- and signal-to-noise-ratios were compared. Subjective image quality was rated by two observers blinded to the protocols. RESULTS: High-pitch DSCT showed a mean estimated radiation dose of 1.27 ± 0.62 mSv, significantly (p < 0.01) lower than sequential (2.04 ± 0.94 mSv), dual-energy (3.97 ± 1.29 mSv) or dual-source (8.11 ± 4.95 mSv) acquisition. Image noise showed no statistical difference (p > 0.91), ranging from 15.2 ± 4.4 (group 2) up to 24.5 ± 22.0 (group 4). Each protocol showed diagnostic image quality in at least 98.1 % of evaluated coronary segments without significant differences (p > 0.05). CONCLUSIONS: Prospectively ECG-gated DSCT protocols enable cCTA with significant dose reduction and consistently diagnostic image quality. In patients requiring retrospectively ECG-gated DSCT for functional analysis or due to arrhythmia, dual-energy mode should be preferred over dual-source mode as it significantly decreases estimated dose without compromising image quality.


Assuntos
Angiografia Coronária/métodos , Aumento da Imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Estudos Retrospectivos
8.
Mol Imaging ; 9(6): 351-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21084031

RESUMO

The purpose of this study was to standardize therapy monitoring of hepatic metastases from gastroenteropancreatic neuroendocrine tumors (GEP-NETs) during the course of somatostatin receptor radionuclide therapy (SRRT). In 21 consecutive patients with nonresectable hepatic metastases of GEP-NETs, chromogranin A (CgA) and 68Ga-DOTATOC PET/CT were compared before and after the last SRRT. On 68Ga-DOTATOC PET/CT, the maximum standard uptake values (SUVmax) of normal liver and hepatic metastases were calculated. In addition, the volumes of hepatic metastases (volume of interest [VOI]) were measured using four cut-offs to separate normal liver tissue from metastases (SUVmax of the normal liver plus 10% [VOIliver+10%], 20% [VOIliver+20%], 30% [VOIliver+30%] and SUV  =  10 [VOI10SUV]). The SUVmax of the normal liver was below 10 (7.2 ± 1.3) in all patients and without significant changes. Overall therapy changes (Δ) per patient (mean [95% CI]) were statistically significant with p < .01 for ΔCgA  =  -43 (-69 to -17), ΔSUVmax  =  -22 (-29 to-14), and ΔVOI10SUV  =  -53 (-68 to -38)% and significant with p < .05 for ΔVOIliver+10%  =  -29 (-55 to -3)%, ΔVOIliver+20%  =  -32 (-62 to -2) and ΔVOIliver+30%  =  -37 (-66 to -8). Correlations were found only between ΔCgA and ΔVOI10SUV (r  =  .595; p < .01), ΔSUVmax and ΔVOI10SUV (0.629, p < .01), and SUVmax and ΔSUVmax (r  =  -.446; p < .05). 68Ga-DOTATOC PET/CT allows volumetric therapy monitoring via an SUV-based cut-off separating hepatic metastases from normal liver tissue (10 SUV recommended).


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida/análogos & derivados , Compostos Organometálicos , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Receptores de Somatostatina/uso terapêutico , Neoplasias Gástricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência
9.
Eur Radiol ; 20(9): 2274-85, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20503051

RESUMO

OBJECTIVE: To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas > or =10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. METHODS: 84 patients, who underwent PET/CT and colonoscopy (n = 79)/sigmoidoscopy (n = 5) for (79 x 6 + 5 x 2) = 484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. RESULTS: Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n = 23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n = 10) the SUV(max) was > or =5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV(max). CONCLUSION: FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV(max) > or = 5 improves the accuracy.


Assuntos
Carga Corporal (Radioterapia) , Neoplasias do Colo/diagnóstico , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Método Simples-Cego , Técnica de Subtração
10.
Mol Imaging Biol ; 12(1): 78-84, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19421819

RESUMO

PURPOSE: To assess DOTATOC-affine somatostatin receptor expression in advanced prostate cancer and its bone metastases with regard to DOTATOC-mediated receptor therapies, using a Ga-68-DOTATOC PET/CT. PROCEDURES: Twenty consecutive patients with advanced prostate cancer underwent bone scintigraphy, followed by Ga-68-DOTATOC PET/CT within 3 weeks. Through side-by-side comparison with bone scintigraphy, the number of visible bone metastases on PET was determined. In addition, in cases of visible metastases, the maximum standard uptake value (SUV(max)) of Ga-68-DOTATOC was measured in the metastases and in normal bone. In patients who did not undergo a prostatectomy (n = 12), the SUV(max) was additionally measured in the prostate and in adjacent tissue. For focal lesions, the difference in SUV(max) (Delta SUV(max)) between the metastases and normal bone was calculated. For patients still having their prostate, a Delta SUV(max) between the prostate and its adjacent tissue was calculated. RESULTS: Sixty four of 216 metastases (30%) were visible in 13 patients with focal metastases. Of six patients with diffuse metastases (superscan), one showed diffuse metastases, three showed a total of ten focal metastases, and two showed no correlate on PET. One patient with a neuroendocrine prostate cancer showed no correlate on PET. The maximum Delta SUV(max) between metastases and normal bone was 4.9 (mean = 1.6 +/- 0.9) and between the prostate and adjacent tissue 5.9 (mean = 2.8 +/- 1.6). CONCLUSIONS: In prostate cancer and its bone metastases, DOTATOC-affine somatostatin receptors (subtype 2 and 5) can be visualized with Ga-68-DOTATOC PET/CT. But their expression is so weak that other conjugates should be tested for receptor-mediated therapies which are better at addressing the prostate cancer-specific somatostatin receptor subtypes 1 and 4-or even other receptors.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Octreotida/análogos & derivados , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Receptores de Somatostatina/metabolismo , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Androgênios , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade
11.
Curr Drug Deliv ; 6(3): 255-60, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19604139

RESUMO

OBJECTIVES: Success of selective drug therapies depends on the drug's depot time in the target to treat. Depot time is currently being prolonged, using drug-eluting beads or microspheres for selective internal radiation therapy. The purpose of this study was to establish a model for investigating the depot time of particles injected into tumors in relation to tumor vascularization and particle size. MATERIALS AND METHODS: An animal model with two different vascularized tumors (Walker Carcinoma 256 (hypervascularized) and Yoshida Sarcoma (hypovascularized)) was used. The tumors were implanted into the hind leg of Wistar rats. When the tumors reached 10-15mm, rhenium radiolabeled particles of 25microm and 0.3microm were percutaneously injected into the tumors: large particles (Re-188 microspheres) in 10 hypo- and 10 hypervascularized tumors and small particles (Re-186 sulfid colloid) in 4 hypo- and 16 hypervascularized tumors with the co-injection of the vasoconstrictor, adrenalin (0.01 mg), into 8 hypervascularized tumors. Tumor activity was measured with a gamma camera at 10 min, 1h, 3h, 6h, 14h and 48h p.i. In addition, activity in the lung, liver, spleen, kidneys, and lymph nodes was measured at 48 h p.i. Measurements were adjusted for decay times and then compared. RESULTS: Drainage of the injected particles is bi-phasic, characterized by a fast wash-out. At 10 min p.i., intratumoral activity decreases to 70% of the initially injected activity. This is followed by a slow decline at 48 h p.i in which intratumoral activity decreases to at least 60% of the initially injected activity. Slow decline is independent of particle size and vascularization, whereas fast leakage depends on both. Co-injecting adrenalin significantly reduced the wash-out of the small particles. Radiolabeled microspheres accumulated mainly in the lungs, smaller colloids in the liver. CONCLUSIONS: Particle stay time, biodistribution, and stability can be easily monitored as shown in this animal model. The hematogeneous wash-out can be reduced, using larger particles and vasoconstrictors. Prolonged retention is independent of vascularization and particle size and appears to be sufficient for therapy.


Assuntos
Microesferas , Modelos Animais , Neoplasias/metabolismo , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/farmacocinética , Animais , Carcinoma 256 de Walker/irrigação sanguínea , Carcinoma 256 de Walker/metabolismo , Epinefrina/farmacologia , Feminino , Humanos , Injeções Intralesionais , Rim/metabolismo , Fígado/metabolismo , Pulmão/metabolismo , Neoplasias/irrigação sanguínea , Radioisótopos/química , Compostos Radiofarmacêuticos/análise , Ratos , Ratos Wistar , Rênio/química , Sarcoma de Yoshida/irrigação sanguínea , Sarcoma de Yoshida/metabolismo , Albumina Sérica/química , Baço/metabolismo , Enxofre/química , Distribuição Tecidual/efeitos dos fármacos
12.
Ann Nucl Med ; 22(9): 735-41, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19039551

RESUMO

OBJECTIVE: To evaluate the effectiveness of radiosynoviorthesis (RSO) in relation to joint type and underlying disease by both self-assessment of patients and scintigraphic assessment to determine conditions under which RSO might be preferable to the sole intra-articular corticoid injection. METHODS: Radiosynoviorthesis was performed on 136 patients for 424 joints [242 small, 130 medium-sized, and 52 large joints; 313 with rheumatoid arthritis (RA) and 111 with osteoarthritis (OA)]. The success of RSO was evaluated after 12 months by patients' estimation, and in 35 patients for 157 joints additionally by two-phase bone scintigraphy. The relative change in the scintigraphic uptake was compared with the patients' estimation. RESULTS: The subjectively estimated success rates for the small, medium-sized, and large joints were 89% (215/242), 86% (112/130), and 79% (41/52), and for RA and OA 89% (280/313) and 79% (88/111), respectively. The scintigraphically determined response rates for small and medium-sized joints were 81% (86/106) and 69% (35/51), respectively. There was a mismatch between patients' assessment and scintigraphic assessments in 18% (28/157) with 6 false-negative and 22 false-positive estimations using scintigraphy as the standard of reference. CONCLUSIONS: The success of RSO is higher in patients with RA than in patients with OA. For the finger, ankle, and wrist joints in RA, RSO is so promising that we would like to advocate its preference over the sole intraarticular corticoid injection. Perfusion bone scintigraphy can be used for therapy monitoring and earlier switching to RSO by showing that other therapies have failed.


Assuntos
Artrite/diagnóstico por imagem , Artrite/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Cintilografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
13.
Radiology ; 249(3): 1017-25, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18849502

RESUMO

In a technical development study approved by the institutional ethics committee, the feasibility of fast diffusion-weighted imaging as a replacement for conventional magnetic resonance (MR) imaging sequences (short inversion time inversion recovery [STIR] and T1-weighted spin echo [SE]) and positron emission tomography (PET)/computed tomography (CT) in the detection of skeletal metastases from prostate cancer was evaluated. MR imaging and carbon 11 ((11)C) choline PET/CT data from 11 consecutive prostate cancer patients with bone metastases were analyzed. Diffusion-weighted imaging appears to be equal, if not superior, to STIR and T1-weighted SE sequences and equally as effective as (11)C-choline PET/CT in detection of bone metastases in these patients. Diffusion-weighted imaging should be considered for further evaluation and comparisons with PET/CT for comprehensive whole-body staging and restaging in prostate and other cancers.


Assuntos
Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/secundário , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/patologia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono , Colina , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
14.
Radiology ; 243(1): 229-38, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17329687

RESUMO

The aim of this study was to prospectively assess the accuracy of three-dimensional magnetic resonance (MR) angiography for evaluation of stenosis in the peripheral arterial system with a continuous moving table technique, with conventional MR angiography as reference. This study was approved by the local institutional review board; informed consent was obtained. Five healthy male volunteers (mean age, 27 years; range, 24-35 years) and four men and one woman (mean age, 63 years; range, 46-78 years) with peripheral arterial occlusive disease were examined. Images obtained with both techniques showed excellent concordance (Cohen kappa = 0.75). Images obtained with a conventional protocol had higher quality compared with those obtained with the continuous technique (mean, 1.07 +/- 0.25 [standard deviation] vs 1.58 +/- 0.6; P < .05); small vessels appeared sharper on them. For detection of significant stenosis and occlusion, accuracy, sensitivity, and specificity of the continuous technique were 92.8%, 100%, and 89.2%, respectively.


Assuntos
Artérias/anatomia & histologia , Imageamento Tridimensional , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Constrição Patológica/diagnóstico , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Projetos Piloto , Artéria Renal/anatomia & histologia , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
15.
AJR Am J Roentgenol ; 187(1): W7-14, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16794142

RESUMO

OBJECTIVE: The purpose of this study was to assess the individual and combined usefulness of MRI techniques in cases of acute pulmonary embolism and to compare the usefulness of these techniques with that of 16-MDCT. SUBJECTS AND METHODS: Sixty-two patients with symptoms indicating acute pulmonary embolism underwent an MRI protocol that progressed from real-time MRI through MR perfusion imaging to MR angiography. The results were compared with those of 16-MDCT, which was the reference standard. Thoracic incidental diagnoses other than pulmonary embolism also were sought with CT and MRI. RESULTS: Pulmonary embolism was diagnosed with CT in 19 patients for totals of 90 lobar, 245 segmental, and 434 subsegmental arteries. On a per-patient basis, the sensitivities of real-time MRI, MR angiography, MR perfusion imaging, and the combined protocol were 85%, 77%, 100%, and 100%, respectively. The specificities were 98%, 100%, 91%, and 93%. The kappa values in a comparison of the MR techniques with CT were 0.89, 0.87, 0.86, and 0.9. On a per-embolus basis, the sensitivities of real-time MRI, MR angiography, and MR perfusion imaging for lobar pulmonary embolism were 79%, 62%, and 100%. The sensitivities for segmental pulmonary embolism were 86%, 83%, and 97%, respectively. MR perfusion imaging had a sensitivity of 93% for subsegmental pulmonary embolism. Eight of nine incidental findings revealed on CT were also subsequently diagnosed with real-time MRI. MRI failed to reveal a case of emphysema. Mean MRI examination time was 9 minutes 56 seconds. CONCLUSION: The combined MR protocol is both reliable and sensitive in comparison with 16-MDCT in the diagnosis of pulmonary embolism. MR perfusion imaging is sensitive for the detection of pulmonary embolism, whereas real-time MR and MR angiography are specific.


Assuntos
Imageamento por Ressonância Magnética , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada por Raios X , Doença Aguda , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/patologia , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade
16.
Eur Radiol ; 15(4): 645-52, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15627189

RESUMO

To assess the benefit of routinely used three-dimensional 1H-spectroscopy of the prostate combined with magnetic resonance imaging in patients with elevated prostate-specific antigen (PSA) levels and negative or no previous prostate biopsies. Fifty-four patients were examined with our combined imaging protocol, which consisted of transversal, coronal and sagittal T2-weighted fast spin echo sequences. For spectroscopy, we used a three-dimensional chemical shift imaging spin echo (3D-CSI-SE) sequence. The study population consisted of patients with elevated PSA levels and histologically proven prostate carcinoma and patients with elevated PSA levels and negative or no previous prostate biopsies. Examination time was 31 min, a time feasible for routine use. Eighty-eight tumour voxels and 67 control voxels of 27 patients with histologically proven prostate carcinoma were analysed. Ratios of (choline + creatine)/citrate [(Cho + Crea)/Cit] below 0.6 were classified as normal and above 0.6 as pathological. Applying this classification to 20 patients with tumour-suspicious lesions of the prostate and negative or no previous prostate biopsies, we could obtain a sensitivity and specificity for tumour detection of 100% and 69%, respectively. Our combined imaging protocol is feasible for routine use and can add valuable information for the diagnostic management of patients with negative or no previous prostate biopsies.


Assuntos
Imageamento Tridimensional , Espectroscopia de Ressonância Magnética/métodos , Antígeno Prostático Específico/sangue , Próstata/patologia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Idoso , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Skeletal Radiol ; 33(12): 712-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15480643

RESUMO

OBJECTIVE: To investigate clinical (pain, mobility) and radiological (resolution of calcium deposits) efficacy of different energy levels of extracorporeal shock wave therapy (ESWT) in calcific tendinitis of the shoulder. DESIGN AND PATIENTS: There were 90 study subjects with radiographically verified calcific tendinitis of one shoulder, mean age 52+/-6 years (range 29-65 years; females:males=55:35), all of whom had had symptoms for at least 6 months and substantial restriction of shoulder mobility and pain that required taking anti-inflammatory drugs. Calcium deposits were of type I or type II (clearly circumscribed and dense) and ranged from 1 cm to 3 cm in diameter. Subjects were divided into three groups to receive ESWT at one of two energy levels (E1=0.15 mJ/mm2, E2=0.44 mJ/mm2) or sham treatment. Treatment was given at 6 weekly intervals until symptoms resolved, five treatments had been given or the subject dropped out of the programme. RESULTS: All subjects in groups E1 and E2 completed the programme. Those in group E1 had significantly less pain during treatment but more treatments than those in group E2, and at 6 month follow-up had residual calcification and recurrence of pain (87%). Subjects in group E2 had no residual calcification or recurrence of pain. Sham treatment had no effect. There were no side effects except a small number of haematomas (2 in E1, 6 in E2; maximum size 2 cm). CONCLUSION: ESWT in calcific tendinitis of the shoulder is very effective. It does not have significant side effects at an energy level of E=0.44 mJ/mm2, which can therefore be recommended.


Assuntos
Calcinose/terapia , Litotripsia , Articulação do Ombro , Tendinopatia/terapia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manguito Rotador/patologia , Resultado do Tratamento
18.
Technol Cancer Res Treat ; 2(1): 13-8, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12625749

RESUMO

In the United States and Europe, colorectal cancer is the second leading cause of cancer-related deaths. It is well known that colorectal carcinomas may originate from preexisting adenomas. For the visualization of colorectal cancer and other pathologic changes such as polyps, two 3D methods (volume-rendering (VR) and surface-rendering (SR)) in MR colonography were compared in our study. MR colonography was carried out in 17 patients on a 1.5 T MR scanner using a 10 mmolar gadolinium water solution enema. Coronal as well as rotated VR and SR views were compared in order to examine the technical quality (TQ) of the visualization model and grade of confidence (GC) in the pathological findings. Colonoscopic findings revealed 8 colorectal carcinoma, 10 patients with polyps, 4 diverticular disease, and 2 with redundant bowel loops. Based on a total of 248 colonic segments for both visualization methods, volume rendering were significantly superior to surface rendering for both, TQ (p<0.0001) and GC (p<0.0001). Volume rendering and surface rendering were not dependent on individual colon segments (p=0.13 for TQ and p=0.18 for GC) or on image rotation (p=0.06 for TQ and p=0.062 for GC). It is also independent of the type of pathology (p=0.31 for TQ and p=0.42 for GC) and the reviewers (p=0.62 for TQ and p=0.88 for GC). This indicates, that for the purpose of interpreting the technical quality and pathological findings, volume rendering is superior to surface rendering in MR colonography. Volume rendering could be used as an 3D visualization tool, enabling MR colonography examinations to be completed sooner in cases where colon distension is sufficient, and it would also provide an overview of potential mass lesions.


Assuntos
Neoplasias Colorretais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso , Neoplasias Colorretais/patologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino
19.
Eur Radiol ; 12(9): 2236-41, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12195475

RESUMO

Automation in colorectal mass detection is achieved as soon as the voxels representing colorectal masses can be automatically segmented. We tested the Hounsfield (HU) value in intensely contrast enhanced high-resolution CT colonography for automated segmentation of colorectal masses in 18 patients with 35 polyps (28 < 10 mm, 7 > or = 10 mm) and 7 carcinomas. Mean HU values of the colonic wall and masses were determined to deduce a gradient threshold for a segmentation process, which encodes the voxels bordering the colonic lumen with a colour ranging in intensity from 0 to 100% according to the selected gradient threshold range in the volume rendering. The results of the automated segmentation process were superimposed on a virtual double contrast and endoscopic display and validated through correlation with morphology. Mean HU values and their standard deviations for the colonic wall, polyps < 10 mm, polyps > or = 10 mm and carcinomas were 63 +/- 24, 154 +/- 38, 116 +/- 41 and 108+/-29 HU, respectively. A gradient threshold ranging from 90 to 160 HU resulted in colour pools in 6 of 7 of polyps > or = 10 mm, and 6 of 7 carcinomas that were significant enough to prospectively guide the reader's attention to these masses. Due to the superposition of "false-positive" voxels in the projection view, the virtual endoscopic perspective was superior to the virtual double contrast display for controlling the segmentation results. The HU value is promising for automated segmentation of colorectal masses but needs to be combined with morphological parameters to render automated colorectal mass detection more accurate. Further refinements of the method with subsequent analysis of its accuracy, as well as analogue studies with contrast-enhanced MRI, appear warranted. More information at http://www.multiorganscreening.org


Assuntos
Colonografia Tomográfica Computadorizada , Diagnóstico por Computador , Idoso , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética
20.
Eur Radiol ; 12(3): 502-24, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11870463

RESUMO

With the introduction of multislice CT technology and faster gradients in MRI, CT and MR colonography are increasingly becoming attractive alternatives for colorectal mass screening. In this article we summarise the current status, research directions, and challenges in CT and MR colonography.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico , Imageamento por Ressonância Magnética , Algoritmos , Neoplasias Colorretais/diagnóstico por imagem , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador/métodos , Programas de Rastreamento , Irrigação Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...