1.
JACC Clin Electrophysiol ; 9(11): 2275-2287, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737775

RESUMO

BACKGROUND: Targeting nonpulmonary vein triggers (NPVTs) of atrial fibrillation (AF) after pulmonary vein isolation can be challenging. NPVTs are often single ectopic beats with a surface P-wave obscured by a QRS or T-wave. OBJECTIVES: The goal of this study was to construct an algorithm to regionalize the site of origin of NPVTs using only intracardiac bipolar electrograms from 2 linear decapolar catheters positioned in the posterolateral right atrium (along the crista terminalis with the distal bipole pair in the superior vena cava) and in the proximal coronary sinus (CS). METHODS: After pulmonary vein isolation in 42 patients with AF, pacing from 15 typical anatomic NPVT sites was conducted. For each pacing site, the electrogram activation sequence was analyzed from the CS catheter (simultaneous/chevron/inverse chevron/distal-proximal/proximal-distal) and activation time (ie, CSCTAT) between the earliest electrograms from the 2 decapolar catheters was measured referencing the earliest CS electrogram; a negative CSCTAT value indicates the crista terminalis catheter electrogram was earlier, and a positive CSCTAT value indicates the CS catheter electrogram was earlier. A regionalization algorithm with high predictive value was defined and tested in a validation cohort with AF NPVTs localized with electroanatomic mapping. RESULTS: In the study patient cohort (71% male; 43% with persistent AF, 52% with left atrial dilation), the algorithm grouped with high precision (positive predictive value 81%-99%, specificity 94%-100%, and sensitivity 30%-94%) the 15 distinct pacing sites into 9 clinically useful regions. Algorithm testing in a 98 patient validation cohort showed predictive accuracy of 91%. CONCLUSIONS: An algorithm defined by the activation sequence and timing of electrograms from 2 linear multipolar catheters provided accurate regionalization of AF NPVTs to guide focused detailed mapping.


Assuntos
Fibrilação Atrial , Veia Cava Superior , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres , Algoritmos
2.
J Cardiovasc Electrophysiol ; 31(8): 2032-2040, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32542894

RESUMO

INTRODUCTION: The association of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) with epicardial and surface ventricular tachycardia (VT) electrogram features, in nonischemic cardiomyopathy (NICM), is unknown. We sought to define the association of LGE and viable wall thickness with epicardial electrogram features and exit site paced QRS duration in patients with NICM. METHODS: A total of 19 patients (age 53.5 ± 11.5 years) with NICM (ejection fraction 40.2 ± 13.2%) underwent CMR before VT ablation. LGE transmurality was quantified on CMR and coregistered with 2294 endocardial and 2724 epicardial map points. RESULTS: Both bipolar and unipolar voltage were associated with transmural signal intensity on CMR. Longer electrogram duration and fractionated potentials were associated with increased LGE transmurality, but late potentials or local abnormal ventricular activity were more prevalent in nontransmural versus transmural LGE regions (p < .05). Of all critical VT sites, 19% were located adjacent to regions with LGE but normal bipolar and unipolar voltage. Exit site QRS duration was affected by LGE transmurality and intramural scar location, but not by wall thickness, at the impulse origin. CONCLUSIONS: In patients with NICM and VT, LGE is associated with epicardial electrogram features and may predict critical VT sites. Additionally, exit site QRS duration is affected by LGE transmurality and intramural location at the impulse origin or exit.


Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Cardiomiopatias/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Gadolínio , Humanos , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
3.
J Cardiovasc Electrophysiol ; 30(6): 865-876, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30834593

RESUMO

INTRODUCTION: Nonpulmonary vein (non-PV) triggers of atrial fibrillation (AF) are targets for ablation but their localization remains challenging. The aim of this study was to describe P-wave (PW) morphologic characteristics and intra-atrial activation patterns and timing from multipolar coronary sinus (CS) and crista terminalis (CT) catheters that localize non-PV triggers. METHODS AND RESULTS: Selective pacing from six right and nine left atrial common non-PV trigger sites was performed in 30 consecutive patients. We analyzed 12 lead ECG features based on PW duration, amplitude and morphology, and patterns and timing of multipolar activation for all 15 sites. Regionalization and then precise localization required criteria present in at least 70% of assessments at each pacing site. The algorithm was then prospectively evaluated by four blinded observers in a validation cohort of 18 consecutive patients undergoing the same pacing protocol and 60 consecutive patients who underwent successful non-PV trigger ablation. The algorithm for site regionalization included 1) negative PW in V1, ≥30 µV change in PW amplitude across the leads V1-V3, and PW duration ≤100 milliseconds in lead 2 and 2) unique intra-atrial activation patterns and timing noted in the multipolar catheters. Specific ECG and intra-atrial activation timing characteristics included in the algorithm allowed for more precise site localization after regionalization. In the prospective evaluation, the algorithm identified the site of origin for 72% of paced and 70% of spontaneous non-PV trigger sites. CONCLUSION: An algorithm based on PW morphology and intra-atrial multipolar activation pattern and timing can help identify non-PV trigger sites of origin.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...