Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Osteoarthritis Cartilage ; 28(9): 1235-1244, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32278071

RESUMO

OBJECTIVE: Evaluate articular cartilage by magnetic resonance imaging (MRI) T2∗ mapping within the distal femur and proximal tibia in adolescents with juvenile osteochondritis dissecans (JOCD). DESIGN: JOCD imaging studies acquired between August 2011 and February 2019 with clinical and T2∗ mapping MRI knee images were retrospectively collected and analyzed for 31 participants (9F/22M, 15.0 ± 3.8 years old) with JOCD lesions in the medial femoral condyle (MFC). In total, N = 32 knees with JOCD lesions and N = 14 control knees were assessed. Mean T2∗ values in four articular cartilage regions-of-interest (MFC, lateral femoral condyle (LFC), medial tibia (MT), and lateral tibia (LT)) and lesion volume were measured and analyzed using Wilcoxon-rank-sum tests and Spearman correlation coefficients (R). RESULTS: Mean ± standard error T2∗ differences observed between the lesion-sided MFC and the LFC in JOCD-affected knees (28.5 ± 0.9 95% confidence interval [26.8, 30.3] vs 26.3 ± 0.7 [24.8, 27.7] ms, P = 0.088) and between the affected- and control-knee MFC (28.5 ± 0.9 [26.8, 30.3] vs 28.5 ± 0.6 [27.1, 29.9] ms, P = 0.719) were nonsignificant. T2∗ was significantly increased in the lesion-sided MT vs the LT for the JOCD-affected knees (21.5 ± 0.7 [20.1, 22.9] vs 18.0 ± 0.7 [16.5, 19.5] ms, P = 0.002), but this same difference was also observed between the MT and LT in control knees (21.0 ± 0.6 [19.7, 22.3] vs 18.1 ± 1.1 [15.8, 20.4] ms, P = 0.037). There was no significant T2∗ difference between the affected- and control-knee MT (21.5 ± 0.7 [20.1, 22.9] vs 21.0 ± 0.6 [19.7, 22.3] ms, P = 0.905). T2∗ within the lesion-sided MFC was not correlated with patient age (R = 0.20, P = 0.28) or lesion volume (R = 0.06, P = 0.75). T2∗ values were slightly increased near lesions in later-stage JOCD subjects but without statistical significance. CONCLUSIONS: T2∗ relaxations times were not significantly different from control sites in the articular cartilage overlying JOCD lesions in the MFC or adjacent MT cartilage in early-stage JOCD.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Osteocondrite Dissecante/diagnóstico por imagem , Adolescente , Idade de Início , Criança , Feminino , Fêmur/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Adulto Jovem
2.
Artigo em Inglês | MEDLINE | ID: mdl-29399370

RESUMO

In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R2>0.998) was observed between measured relaxation rates (R1/R2) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...