Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 20(21): 23456-62, 2012 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-23188309

RESUMO

We report the design and characterization of external-cavity DBR lasers built with a III-V-semiconductor reflective-SOA with spot-size converter edge-coupled to SOI waveguides containing Bragg grating mirrors. The un-cooled lasers have wall-plug-efficiencies of up to 9.5% at powers of 6 mW. The lasers are suitable for making power efficient, hybrid WDM transmitters in a CMOS-compatible SOI optical platform.


Assuntos
Lasers , Lentes , Refratometria/instrumentação , Semicondutores , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento
2.
Opt Express ; 18(23): 23784-9, 2010 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-21164722

RESUMO

Previously demonstrated high-order silicon ring filters typically have bandwidths larger than 100 GHz. Here we demonstrate 1-2 GHz-bandwidth filters with very high extinction ratios (~50 dB). The silicon waveguides employed to construct these filters have propagation losses of ~0.5 dB/cm. Each ring of a filter is thermally controlled by metal heaters situated on the top of the ring. With a power dissipation of ~72 mW, the ring resonance can be tuned by one free spectral range, resulting in wavelength-tunable optical filters. Both second-order and fifth-order ring resonators are presented, which can find ready application in microwave/radio frequency signal processing.

3.
Biosens Bioelectron ; 14(4): 377-86, 1999 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-10422239

RESUMO

This paper presents the detailed design and characterisation of a regenerable integrated optical surface plasmon resonance immunoprobe as a detector for the triazine herbicide simazine. A sensor design theoretically optimised for use in the aqueous environment is presented and its fabrication described. Experimental results on the sensitivity to changes in bulk refractive index of the analyte and on non-specific binding of ovalbumin are presented. Binding inhibition immunoassays were conducted for simazine and the lower limit of detection determined to be 0.16 microgram/l using anti-simazine IgG antibodies and 0.11 microgram/l using anti-simazine Fab fragments. A sample test cycle of 20 min was established.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental/métodos , Herbicidas/análise , Óptica e Fotônica , Simazina/análise , Ressonância de Plasmônio de Superfície , Desenho de Equipamento , Imunoensaio , Sensibilidade e Especificidade , Transdutores
4.
Appl Opt ; 36(27): 7066-72, 1997 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-18259582

RESUMO

The use of indium tin oxide (ITO) thin films as electrodes for integrated optical electrochemical sensor devices is discussed. The effect of various thicknesses of ITO overlayers exhibiting low resistivity and high transparency on potassium ion-exchanged waveguides fabricated in glass substrates is investigated over the wavelength range 500-900 nm. ITO overlayers are formed by reactive thermal evaporation in oxygen, followed by annealing in air to a maximum temperature of 320 degrees C. With air as the superstrate, losses in the waveguides were found to increase dramatically above 30-nm ITO thickness for TE polarization and above 50-nm thickness for TM. Losses were increased over the whole wavelength range for a superstrate index close to that of water. A one-dimensional, multilayer waveguide model is used in the interpretation of the experimental results.

5.
Opt Lett ; 21(8): 618-20, 1996 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19876102

RESUMO

We present measurements of biomolecular binding reactions, using a new type of integrated-optical biosensor based on a planar directional coupler structure. The device is fabricated by Ag(+) - Na(+) ion exchange in glass, and definition of the sensing region is achieved by use of transparent fluoropolymer isolation layers formed by thermal evaporation. The suitability of the sensor for application to the detection of environmental pollutants is considered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...