Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am Heart J ; 269: 15-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38042457

RESUMO

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Assuntos
Ablação por Cateter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Carga de Sintomas , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirurgia , Sistema de Registros
2.
Environ Technol ; 43(22): 3426-3443, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33900149

RESUMO

This research aimed to identify a tool to objectively analyse the performance and the environmental contextualisation of sewer systems (SwSs) and wastewater treatment plants (WWTPs). This procedure performs assessment by calculating performance indices which could be subsequently applied to SwSs and WWTPs with different characteristics. The proposed tool can be applied conveniently over the years by managers of integrated urban water management systems for the analysis of different realities also allowing the evaluation of the effects of upgrades carried out during the management phases. The proposed analysis allows the optimisation of SwSs and can profitably guide the choice and the priority among possible interventions for the sewerage infrastructure and WWTPs providing a verification and evaluation protocol as well as a financial planning tool.


Assuntos
Águas Residuárias , Purificação da Água , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/análise
3.
Indian Pacing Electrophysiol J ; 20(6): 221-226, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32599079

RESUMO

BACKGROUND: Oesophageal changes and injuries were recorded after atrial fibrillation(AF) ablation procedures. The reduction of power in the posterior left atrial(LA) wall(closest to the oesophagus) and the monitoring of temperature in the oesophagus(OE) reduced oesophageal injuries. The intracardiac-echocardiography(ICE) with a Cartosound module provides two-dimensional imaging (2D) to assess detailed cardiac anatomy and its relationship with the OE. The aim of this study was to highlight the safety and feasibility of 3D-reconstruction of the oesophageal course in left atrial catheter ablation(CA) procedures without OE temperature probe or quadripolar catheter to guide ICE OE reconstruction. METHODS: 180 patients(PT) underwent left atrial ablation. AF ablation were 125(69.5%); incisional left atrial tachycardias(IAFL) were 37(20.6%); left atrial tachycardias(LAT) were 19(10.6%). The LA and pulmonary vein anatomies were rendered by traditional electroanatomic mapping(EAM) and merged with an ICE anatomic map. In 109 PT ICE imaging was used to create a geometry of the OE(group A). A quadripolar catheter was used in 71 PT to show OE course associated to ICE(group B). RESULTS: Ablation energy delivery was performed outside the broadest OE anatomy borders. The duration of procedures was longer in group B vs group A Fluoroscopy time was lower in Group A than Group B(Group A 7 ± 3.2 vs 19.2 ± 2.4 min; p < 0.01). CONCLUSIONS: OE monitoring with ICE is safe and feasible. Oesophageal anatomy is complex and variable. Many PT will have a broad oesophageal boundary, which increases the risk of untoward thermal injury during posterior LA ablation. ICE with 3D construction of the OE enhances border detection of the OE, and as such, should decrease the risk of oesophageal injury by improving avoidance strategies without intra-oesophageal catheter visualization.

4.
J Atr Fibrillation ; 9(5): 1542, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250275

RESUMO

Congenital heart disease patients are considered a unique group of patients regarding their high risk of conduction abnormalities , whether de novo or surgically induced , and the challenges in both implantation and management of device related complications. We present a case of a pacemaker-dependent patient with congenital heart disease who experienced complications of both previous epicardial and transvenous pacing which rendered her a non-suitable candidate of both routes.

5.
Am J Cardiol ; 120(10): 1905-1907, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28917494

RESUMO

A 68-year-old man underwent pulmonary vein isolation with cryoballoon combined with left atrial appendage closure using a LAmbre device. The device was dislodged and embolized early after implantation with no symptoms, and it was retrieved percutaneously. An early in-hospital check of the device position after implantation is important for early recognition of any possible device-related complication.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Comunicação Interatrial/cirurgia , Complicações Pós-Operatórias/diagnóstico , Dispositivo para Oclusão Septal/efeitos adversos , Idoso , Apêndice Atrial/cirurgia , Remoção de Dispositivo , Ecocardiografia , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/cirurgia , Humanos , Masculino
6.
Expert Rev Med Devices ; 14(8): 609-619, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28678556

RESUMO

INTRODUCTION: During the past years, endomyocardial biopsy (EMB) has gradually spread into clinical practice. However, the role of EMB in the diagnosis and treatment of cardiovascular diseases remains a controversial issue, especially in the setting of unexplained ventricular arrhythmias. Areas covered: This review describes the methodology of EMB guided by combined use of three-dimensional electroanatomical mapping systems and intracardiac echo and summarizes the classical, fluoroscopy-guided EMB technique. Finally, the personal experience acquired with the 'electrophysiologist-made' integration methodology has been reported. Expert commentary: Since EMB has been considered in the setting of arrhythmogenic cardiomyopathy, myocarditis, cardiac sarcoidosis, drug toxicity, and/or other diseases causing malignant ventricular arrhythmias, the electrophysiologists have started to perform firsthand biopsy. The electrophysiologists introduced the use of electroanatomical mapping systems and intracardiac echo. This new methodology improved significantly biopsy diagnostic yield and allowed to reduce complications.


Assuntos
Cardiomiopatias/patologia , Biópsia Guiada por Imagem/instrumentação , Miocárdio/patologia , Sarcoidose/patologia , Arritmias Cardíacas/etiologia , Cardiomiopatias/complicações , Humanos , Biópsia Guiada por Imagem/métodos , Miocardite/patologia
7.
Pacing Clin Electrophysiol ; 38(9): 1058-65, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26010612

RESUMO

BACKGROUND: Ultrasound (US) guidance increases safety and efficacy in vascular cannulation and is considered the standard of care. However, barriers including workflow interference and the need to be assisted by a second operator limit its adoption in clinical routine. The use of wireless US (WUS) may overcome these barriers. The aim of this study was to assess the impact of a novel WUS probe during its initial implantation in an electrophysiology (EP) laboratory. METHODS: Thirty-six patients requiring femoral venous cannulation for EP procedures were included in this single center, prospective, observational study, comparing WUS guidance with the anatomical landmark approach. The primary endpoint was time to successful cannulation. Secondary endpoints included rate of unsuccessful punctures, accidental arterial punctures, and workflow interference. RESULTS: Compared with anatomical landmark approach, WUS guidance significantly reduced mean time to successful cannulation (87.3 ± 94.3 vs 238.1 ± 294.7 seconds, P < 0.01). Workflow interference was predominantly nonexistent or mild and decreased after the first three weeks of use. In addition, WUS guidance improved safety and efficacy, reducing the rate of accidental arterial punctures (0.02 ± 0.1 vs 0.25 ± 0.5 arterial punctures per cannulation, P < 0.05) and unsuccessful attempts (0.26 ± 0.8 vs 1.75 ± 2.1 attempts per cannulation, P < 0.01). CONCLUSIONS: WUS guidance resulted in faster, safer, and more effective femoral venous cannulation than the anatomical landmark approach without adding significant workflow interference. The application of wireless technology in this setting contributed to overcoming some of the barriers preventing a more widespread clinical use of US guidance.


Assuntos
Cateterismo/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veia Femoral/diagnóstico por imagem , Ultrassonografia de Intervenção/instrumentação , Tecnologia sem Fio/instrumentação , Fluxo de Trabalho , Idoso , Cateterismo/efeitos adversos , Cateterismo/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...