Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(9): 15199-15214, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38859177

RESUMO

When the microprobe sensor is faced with the demand of high-speed biaxial displacement measurement, due to the characteristics of phase generated carrier (PGC) technology, accompanying optical intensity modulation (AOIM) and unfavorable phase modulation depth (PMD) will bring about the tens of nanometer cyclic nonlinear errors, further hindering high-speed and high-precision measurement. Herein, a light source intensity stabilization system based on semiconductor optical amplifier (SOA) feedback control is achieved to eliminate the error caused by AOIM in the presence of high-frequency and large-amplitude laser modulation. Based on this, the reasons for large nonlinear errors in biaxial measurements and the inability to ensure the stability of the accuracy of multiple measurement axes are methodically examined, and an effective nonlinear error elimination methodology based on the normalized amplitude correction of active temperature scanning is proposed. The continuity and linearity of the temperature scanning are also discussed. The performed experiments show that the above approach is capable of reducing the displacement demodulation error from the nanometer scale to the sub-nanometer scale. Further, the nonlinear error is reduced to within 0.1 nm for both measurement axes and the performance becomes consistent. The dual-axis measurement resolution of the microprobe sensor reaches 0.4 nm and the measurement speed is better than 1.2 m/s with the standard deviation of lower than 0.5 nm.

2.
Environ Int ; 190: 108855, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38945088

RESUMO

Facing the great threats to ecosystems and human health posed by the continuous release of chemicals into aquatic environments, effect-directed analysis (EDA) has emerged as a powerful tool for identifying causative toxicants. However, traditional EDA shows problems of low-coverage, labor-intensive and low-efficiency. Currently, a number of high-efficiency techniques have been integrated into EDA to improve toxicant identification. In this review, the latest progress and current limitations of high-efficiency EDA, comprising high-coverage effect evaluation, high-resolution fractionation, high-coverage chemical analysis, high-automation causative peak extraction and high-efficiency structure elucidation, are summarized. Specifically, high-resolution fractionation, high-automation data processing algorithms and in silico structure elucidation techniques have been well developed to enhance EDA. While high-coverage effect evaluation and chemical analysis should be further emphasized, especially omics tools and data-independent mass acquisition. For the application status in aquatic environments, high-efficiency EDA is widely applied in surface water and wastewater. Estrogenic, androgenic and aryl hydrocarbon receptor-mediated activities are the most concerning, with causative toxicants showing the typical structural features of steroids and benzenoids. A better understanding of the latest progress and application status of EDA would be beneficial to further advance in the field and greatly support aquatic environment monitoring.

3.
Micromachines (Basel) ; 15(2)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38398953

RESUMO

In this paper, a fiber optic microprobe displacement sensor is proposed considering characteristics of micro-Michelson interference structure and its components. The principal error of micro Fabry-Perot interferometric structure is avoided, and high-precision interferometric displacement measurement is realized. The collimated microprobe and convergent microprobe are analyzed, simulated, and designed for the purposes of measuring long-distance displacement and small spot rough surface, respectively. The core parameters of the probes' internal components are mapped to coupling efficiency and contrast of the sensor measurements, which provides a basis for the probes' design. Finally, simulation and experimental testing of the two probes show that the collimated probe's working distance and converging probe's tolerance angle can reach 40 cm and ±0.5°, respectively. The designed probes are installed in the fiber laser interferometer, and a displacement resolution of 0.4 nm is achieved.

4.
Water Res ; 253: 121303, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38382288

RESUMO

Many organic pollutants were detected in tap water (TW) and source water (SW) along the Yangtze River. However, the potential toxic effects and the high-concern organics (HCOs) which drive the effect are still unknown. Here, a non-targeted toxicity testing method based on the concentration-dependent transcriptome and non-targeted LC-HRMS analysis combining tiered filtering were used to reveal the overall biological effects and chemical information. Subsequently, we developed a qualitative pathway-structure relationship (QPSR) model to effectively match the biological and chemical information and successfully identified HCOs in TW and SW along the Yangtze River by potential substructures of HCOs. Non-targeted toxicity testing found that the biological potency of both TW and SW was stronger in the downstream of the Yangtze River, and disruption of the endocrine system and cancer were the main drivers of the effect. In addition, non-targeted LC-HRMS analysis combined with retention time prediction results identified 3220 and 631 high-confidence compound structures in positive and negative ion modes, respectively. Then, QPSR model was further implied and identified a total of 103 HCOs, containing 35 industrial chemicals, 30 PPCPs, 26 pesticides, and 12 hormones in TW and SW, respectively. Among them, the neuroactive and hormonal compounds oxoamide, 8-iso-16-cyclohexyl-tetranor prostaglandin E2, E Keppra, and Tocris-0788 showed the highest frequency of detection, which were identified in more than 1/3 of the samples. The strategy of combining non-targeted toxicity testing and non-targeted LC-HRMS analysis will support comprehensive biological effect assessment, identification of HCOs, and risk control of mixtures.


Assuntos
Poluentes Ambientais , Praguicidas , Poluentes Químicos da Água , Água/análise , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/análise , Praguicidas/análise , Rios/química , Poluentes Ambientais/análise , Monitoramento Ambiental/métodos , China
5.
Med Phys ; 50(4): 2239-2248, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36433795

RESUMO

BACKGROUND AND PURPOSE: Accurate and efficient medical image segmentation plays an important role in subsequent clinical applications such as diagnosis and surgical planning. This paper proposes an efficient interactive framework based on a graph convolutional network (GCN) for medical image segmentation. METHODS: The initial segmentation results showed that a set of boundary control points can be generated for further interactive segmentation. We presented an adaptive interactive manner that allows the user to click on the boundary for fast interaction or drag the erroneous predicted control points for accurate correction. Furthermore, we proposed an interactive segmentation network (referred to as IVIF-GCN) to learn user experience in the interactive process by transforming interactive cues into annotations. In IVIF-GCN, a module of information fusion of image features and vertex position features (IVIF) is proposed to learn the location relationship between the current vertex and the neighboring vertices. Finally, the locations of control points around the interaction point is predicted and updated automatically. RESULTS: The proposed method achieves mean Dice of 96.6% and 91.3% on PROMISE12 and our in-house nasopharyngeal carcinoma (NPC) test sets, respectively. The experimental results showed that the proposed method outperforms the state-of-the-art segmentation methods. CONCLUSIONS: The proposed interactive medical image segmentation method can efficiently improve segmentation results for clinical applications in the absence of training data. The GUI tool based on our method is available at https://github.com/Tian-lab/IGMedSeg.


Assuntos
Neoplasias Nasofaríngeas , Humanos , Carcinoma Nasofaríngeo , Processamento de Imagem Assistida por Computador/métodos
6.
Sci Total Environ ; 857(Pt 3): 159416, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36244484

RESUMO

Recently, numerous organic pollutants have been detected in water environment. The safety of our drinking water has attracted widespread attention. Effective methods to screen and identify high-concern substances are urgently needed. In this study, the combined workflow for the detection and identification of high-concern organic chemicals was established and applied to tap water samples from the Yangtze River Basin. The solid phase extraction (SPE) sorbents were compared and evaluated and finally the HLB cartridge was selected as the best one for most of the contaminants. Based on target, suspect and non-target analysis, 3023 chemicals/peaks were detected. Thirteen substances such as diundecyl phthalate (DUP), 2-hydroxyatrazine, dioxoaminopyrine and diethyl-2-phenylacetamide were detected in drinking water in the Yangtze River Basin for the very first time. Based on three kinds of prioritization principles, 49 ubiquitous, 103 characteristic chemicals and 13 inefficiently removed chemicals were selected as high-concern substances. Among them, 8, 31, 9, 3, 4 substances overlapped with the toxic, risky or high-concern chemicals lists in China, America, European Union, Japan, Korea, respectively. Specific management and removal strategies were further recommended. The workflow is efficient for identification of key pollutants.


Assuntos
Água Potável , Poluentes Ambientais , Poluentes Químicos da Água , Rios/química , Poluentes Ambientais/análise , Água Potável/análise , Poluentes Químicos da Água/análise , Compostos Orgânicos/análise , China , Monitoramento Ambiental/métodos
7.
Chin Med Sci J ; 32(3): 152-160, 2017 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-28956742

RESUMO

Objective To construct a model of Seasonal Autoregressive Integrated Moving Average (SARIMA) for forecasting the epidemic of Japanese encephalitis (JE) in Xianyang, Shaanxi, China, and provide valuable reference information for JE control and prevention. Methods Theoretically epidemiologic study was employed in the research process. Monthly incidence data on JE for the period from Jan 2005 to Sep 2014 were obtained from a passive surveillance system at the Center for Diseases Prevention and Control in Xianyang, Shaanxi province. An optimal SARIMA model was developed for JE incidence from 2005 to 2013 with the Box and Jenkins approach. This SARIMA model could predict JE incidence for the year 2014 and 2015. Results SARIMA (1, 1, 1) (2, 1, 1)12 was considered to be the best model with the lowest Bayesian information criterion, Akaike information criterion, Mean Absolute Error values, the highest R2, and a lower Mean Absolute Percent Error. SARIMA (1, 1, 1) (2, 1, 1)12 was stationary and accurate for predicting JE incidence in Xianyang. The predicted incidence, around 0.3/100 000 from June to August in 2014 with low errors, was higher compared with the actual incidence. Therefore, SARIMA (1, 1, 1) (2, 1, 1)12 appeared to be reliable and accurate and could be applied to incidence prediction. Conclusions The proposed prediction model could provide clues to early identification of the JE incidence that is increased abnormally (≥0.4/100 000). According to the predicted Results in 2014, the JE incidence in Xianyang will decline slightly and reach its peak from June to August.


Assuntos
Encefalite Japonesa/epidemiologia , Modelos Biológicos , Estações do Ano , China/epidemiologia , Humanos , Incidência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA