Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Bioengineering (Basel) ; 11(8)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39199775

RESUMO

Personalized orthopedic devices are increasingly favored for their potential to enhance long-term treatment success. Despite significant advancements across various disciplines, the seamless integration and full automation of personalized orthopedic treatments remain elusive. This paper identifies key interdisciplinary gaps in integrating and automating advanced technologies for personalized orthopedic treatment. It begins by outlining the standard clinical practices in orthopedic treatments and the extent of personalization achievable. The paper then explores recent innovations in artificial intelligence, biomaterials, genomic and proteomic analyses, lab-on-a-chip, medical imaging, image-based biomechanical finite element modeling, biomimicry, 3D printing and bioprinting, and implantable sensors, emphasizing their contributions to personalized treatments. Tentative strategies or solutions are proposed to address the interdisciplinary gaps by utilizing innovative technologies. The key findings highlight the need for the non-invasive quantitative assessment of bone quality, patient-specific biocompatibility, and device designs that address individual biological and mechanical conditions. This comprehensive review underscores the transformative potential of these technologies and the importance of multidisciplinary collaboration to integrate and automate them into a cohesive, intelligent system for personalized orthopedic treatments.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38231253

RESUMO

Achieving successful bone regeneration necessitates the design of scaffolds that meet diverse biological and mechanical requirements, often leading to conflicts in the design parameters. A key conflict arises between scaffold porosity and stiffness. Increasing porosity facilitates cell infiltration and nutrient exchange, promoting bone regeneration. However, higher porosity compromises scaffold stiffness, which is crucial for providing structural support in the defective region. Furthermore, appropriate scaffold stiffness is crucial for preventing stress shielding. Conventional geometry-based design methods utilizing single-phase materials have limited flexibility in resolving such conflicts. To address this challenge, we propose a voxel-based method for designing composite scaffolds composed of hydroxyapatite (HA) and polylactic acid (PLA). Our strategy involves first satisfying primary biological requirements by selecting appropriate porosity, pore shape, and size. Subsequently, scaffold stiffness requirements are met by selecting suitable phase materials and tuning their contents. The study demonstrates that the voxel-based approach effectively balances both biological and mechanical requirements in scaffold design. This method addresses the limitations of traditional designs by achieving an optimal balance between porosity and stiffness, which is crucial for scaffold performance in biomedical applications. Moreover, the scaffolds designed using this method can be manufactured using voxel-based 3D printing technology, which is emerging in the field. Future advancements in voxel-based 3D printing technology will further enhance the feasibility and practicality of this approach for bone tissue engineering applications.

3.
Materials (Basel) ; 16(18)2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37763426

RESUMO

Three-phase particulate composites offer greater design flexibility in the selection of phase materials and have more design variables than their two-phase counterparts, thus providing larger space for tailoring effective properties to meet intricate engineering requirements. Predicting effective elastic properties is essential for composite design. However, experimental methods are both expensive and time intensive, whereas the scope of analytical micromechanics models is limited by their inherent assumptions. The newly developed microstructure-free finite element modeling (MF-FEM) approach has been demonstrated to be accurate and reliable for two-phase particulate composites. In this study, we investigate whether the MF-FEM approach can be applied to three-phase particulate composites and, if applicable, under which conditions. The study commences with a convergence analysis to establish the threshold ratio between the element size and the RVE (representative volume element) dimension. We then validate the MF-FEM approach using experimental data on three-phase composites from the existing literature. Subsequently, the MF-FEM method serves as a benchmark to assess the accuracy of both traditional and novel analytical micromechanics models, in predicting the effective elasticity of two distinct types of three-phase particulate composites, characterized by their small and large phase contrasts, respectively. We found that the threshold element-to-RVE ratio (1/150) for three-phase composites is considerably smaller than the ratio (1/50) for two-phase composites. The validation underscores that MF-FEM predictions align closely with experimental data. The analytical micromechanics models demonstrate varying degrees of accuracy depending on the phase volume fractions and the contrast in phase properties. The study indicates that the analytical micromechanics models may not be dependable for predicting effective properties of three-phase particulate composites, particularly those with a large contrast in phase properties. Even though more time-intensive, the MF-FEM proves to be a more reliable approach than the analytical models.

4.
Materials (Basel) ; 16(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37570036

RESUMO

This Special Issue of the journal Materials aims to gather recent advancements and novel developments in the field of finite element modeling of microstructures in composite materials [...].

5.
Materials (Basel) ; 15(16)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36013799

RESUMO

The Poisson effect, measured by the Poisson's ratio, plays an important role in the regulation of the elastic properties of composite materials, but it is not considered in the conventional Voigt (iso-strain) and Reuss (iso-stress) formulas, which explains why the formulas are inaccurate even if the iso-strain or the iso-stress conditions are satisfied. To consider the Poisson effect, we derived a set of new formulas based on the governing equations of elasticity. The obtained formulas show greater mathematical complexity. To further understand how the Poisson effect influences composite elastic properties, two types of finite element models (FEM) were constructed to simulate the situations where the Poisson effect does or does not have an influence. The results show that the conventional Voigt and Reuss formulas are special cases of the newly derived ones. The Poisson effect induces secondary strains and stresses into the phase materials, which demands more strain energy to achieve the same deformation in the primary (loading) direction, and thus increases composite stiffness; the magnitude of the increase is dependent on the contrast of phase properties. The findings may have significant impact on the study of the emerging nanocomposites and functionally graded materials, where the conventional Voigt and Reuss formulas have wide applications.

6.
Materials (Basel) ; 15(11)2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-35683326

RESUMO

Micromechanics models of composite materials are preferred in the analysis and design of composites for their high computational efficiency. However, the accuracy of the micromechanics models varies widely, depending on the volume fraction of inclusions and the contrast of phase properties, which have not been thoroughly studied, primarily due to the lack of complete and representative experimental data. The recently developed microstructure-free finite element modeling (MF-FEM) is based on the fact that, for a particulate-reinforced composite, if the characteristic size of the inclusions is much smaller than the composite representative volume element (RVE), the elastic properties of the RVE are independent of inclusion shape and size. MF-FEM has a number of advantages over the conventional microstructure-based finite element modeling. MF-FEM predictions have good to excellent agreement with the reported experiment results. In this study, predictions produced by MF-FEM are used in replace of experimental data to compare the accuracy of selected micromechanics models of particulate composites. The results indicate that, only if both the contrasts in phase Young's moduli and phase Poisson's ratios are small, the micromechanics models are able to produce accurate predictions. In other cases, they are more or less inaccurate. This study may serve as a guide for the appropriate use of the micromechanics models.

7.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35336463

RESUMO

This study conducts an in-depth evaluation of imaging algorithms and software and hardware architectures to meet the capability requirements of real-time image acquisition systems, such as spaceborne and airborne synthetic aperture radar (SAR) systems. By analysing the principles and models of SAR imaging, this research creatively puts forward the fully parallel processing architecture for the back projection (BP) algorithm based on Field-Programmable Gate Array (FPGA). The processing time consumption has significant advantages compared with existing methods. This article describes the BP imaging algorithm, which stands out with its high processing accuracy and two-dimensional decoupling of distance and azimuth, and analyses the algorithmic flow, operation, and storage requirements. The algorithm is divided into five core operations: range pulse compression, upsampling, oblique distance calculation, data reading, and phase accumulation. The architecture and optimisation of the algorithm are presented, and the optimisation methods are described in detail from the perspective of algorithm flow, fixed-point operation, parallel processing, and distributed storage. Next, the maximum resource utilisation rate of the hardware platform in this study is found to be more than 80%, the system power consumption is 21.073 W, and the processing time efficiency is better than designs with other FPGA, DSP, GPU, and CPU. Finally, the correctness of the processing results is verified using actual data. The experimental results showed that 1.1 s were required to generate an image with a size of 900 × 900 pixels at a 200 MHz clock rate. This technology can solve the multi-mode, multi-resolution, and multi-geometry signal processing problems in an integrated manner, thus laying a foundation for the development of a new, high-performance, SAR system for real-time imaging processing.

8.
Med Biol Eng Comput ; 60(3): 843-854, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35119555

RESUMO

Early assessment of hip fracture helps develop therapeutic and preventive mechanisms that may reduce the occurrence of hip fracture. An accurate assessment of hip fracture risk requires proper consideration of the loads, the physiological and morphological parameters, and the interactions between these parameters. Hence, this study aims at analyzing the significance of parameters and their interactions by conducting a quantitative statistical analysis. A multiple regression model was developed considering different loading directions during a sideways fall (angle [Formula: see text] and [Formula: see text] on the coronal and transverse planes, respectively), age, gender, patient weight, height, and femur morphology as independent parameters and Fracture Risk Index (FRI) as a dependent parameter. Strain-based criteria were used for the calculation of FRI with the maximum principal strain obtained from quantitative computed tomography-based finite element analysis. The statistical result shows that [Formula: see text] [Formula: see text], age [Formula: see text], true moment length [Formula: see text], gender [Formula: see text], FNA [Formula: see text], height [Formula: see text], and FSL [Formula: see text] significantly affect FRI where [Formula: see text] is the most influential parameter. The significance of two-level interaction [Formula: see text] and three-level interaction [Formula: see text] shows that the effect of parameters is dissimilar and depends on other parameters suggesting the variability of FRI from person to person.


Assuntos
Fraturas do Quadril , Acidentes por Quedas , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Análise de Elementos Finitos , Fraturas do Quadril/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
9.
Front Pharmacol ; 13: 967457, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36686705

RESUMO

Background: Hypertensive cerebral small vessel disease (HT-CSVD) is a cerebrovascular clinical, imaging and pathological syndrome caused by hypertension (HT). The condition manifests with lesions in various vessels including intracranial small/arterioles, capillaries, and small/venules. Hypertensive cerebral small vessel disease has complex and diverse clinical manifestations. For instance, it can present as an acute stroke which progresses to cause cognitive decline, affective disorder, unstable gait, dysphagia, or abnormal urination. Moreover, hypertensive cerebral small vessel disease causes 25-30% of all cases of ischemic strokes and more than 50% of all cases of single or mixed dementias. The 1-year recurrence rate of stroke in cerebral small vessel disease patients with hypertension is 14%. In the early stage of development, the symptoms of hypertensive cerebral small vessel disease are concealed and often ignored by patients and even clinicians. Patients with an advanced hypertensive cerebral small vessel disease manifest with severe physical and mental dysfunction. Therefore, this condition has a substantial economic burden on affected families and society. Naotaifang (NTF) is potentially effective in improving microcirculation and neurofunction in patients with ischemic stroke. In this regard, this multicenter randomized controlled trial (RCT) aims to furtherly evaluate the efficacy and safety of naotaifang capsules on hypertensive cerebral small vessel disease. Methods: This study is a multicenter, randomized, double-blind, placebo-controlled clinical trial. A total of 388 eligible subjects were recruited from the First Hospital of Hunan University of Chinese Medicine, Hunan Academy of Chinese Medicine Affiliated Hospital, the First Hospital of Shaoyang University, the First Traditional Chinese Medicine Hospital of Changde, and Jiangmen Wuyi Hospital of Traditional Chinese Medicine from July 2020 to April 2022. After a 4-week run-in period, all participants were divided into the intervention group (represented by Y-T, N-T) and control group (represented by Y-C, N-C); using a stratified block randomized method based on the presence or absence of brain damage symptoms in hypertensive cerebral small vessel disease (represented by Y and N). The Y-T and N-T groups were administered different doses of naotaifang capsules, whereas Y-C and N-C groups received placebo treatment. These four groups received the treatments for 6 months. The primary outcome included Fazekas scores and dilated Virchow-robin spaces (dVRS) grades on magnetic resonance imaging (MRI). The secondary outcomes included the number of lacunar infarctions (LI) and cerebral microbleeds (CMB) on magnetic resonance imaging, clinical blood pressure (BP) level, traditional Chinese medicine (TCM) syndrome scores, mini-mental state examination (MMSE) scale, and safety outcomes. Fazekas scores, dilated Virchow-robin spaces grades, and the number of lacunar infarctions and cerebral microbleeds on magnetic resonance imaging were tested before enrollment and after 6 months of treatment. The clinical blood pressure level, traditional Chinese medicine syndrome scores, mini-mental state examination scale and safety outcomes were tested before enrollment, after 3-month, 6-month treatment and 12th-month follow-up respectively. Conclusion: The protocol will comfirm whether naotaifang capsules reduce Fazekas scores, dilated Virchow-robin spaces grades, and the number of lacunar infarctions and cerebral microbleeds, clinical blood pressure, increase mini-mental state examination scores, traditional Chinese medicine syndrome scores of Qi deficiency and blood stasis (QDBS), and improve the quality of life of subjects. The consolidated evidence from this study will shed light on the benefits of Chinese herbs for hypertensive cerebral small vessel disease, such as nourishing qi, promoting blood circulation and removing blood stasis, and dredging collaterals. However, additional clinical trials with large samples and long intervention periods will be required for in-depth research. Clinical Trial registration: www.chictr.org.cn, identifier ChiCTR1900024524.

10.
Appl Bionics Biomech ; 2021: 4928396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34754330

RESUMO

BACKGROUND: Bone mineral density is widely used by clinicians for screening osteoporosis and assessing bone strength. However, its effectiveness has been reported unsatisfactory. In this study, it is demonstrated that bone organic-inorganic phase ratio is a fundamental determinant of bone material quality measured by stiffness, strength, and toughness. METHODS AND RESULTS: Two-hundred standard bone specimens were fabricated from bovine legs, with a specialized manufacturing method that was designed to reduce the effect of bone anisotropy. Bone mechanical properties of the specimens, including Young's modulus, yield stress, peak stress, and energy-to-failure, were measured by mechanical testing. Organic and inorganic mass contents of the specimens were then determined by bone ashing. Bone density and organic-inorganic phase ratio in the specimens were calculated. Statistical methods were applied to study relationships between the measured mechanical properties and the organic-inorganic phase ratios. Statistical characteristics of organic-inorganic phase ratios in the specimens with top material quality were investigated. Bone organic-inorganic phase ratio had strong Spearman correlation with bone material properties. Bone specimens that had the highest material quality had a very narrow scope of organic-inorganic phase ratio, which could be considered as the "optimal" ratio among the tested specimens. CONCLUSION: Bone organic-inorganic phase ratio is a fundamental determinant of bone material quality. There may exist an "optimal" ratio for the bone to achieve top material quality. Deviation from the "optimal" ratio is probably the fundamental cause of various bone diseases. This study suggests that bone organic-inorganic phase ratio should be considered in clinical assessment of fracture risk.

11.
J Bone Miner Metab ; 39(4): 523-533, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33423096

RESUMO

INTRODUCTION: Hip fracture is a common health risk among elderly people, due to the prevalence of osteoporosis and accidental fall in the population. Accurate assessment of fracture risk is a crucial step for clinicians to consider patient-by-patient optimal treatments for effective prevention of fractures. Image-based biomechanical modeling has shown promising progress in assessment of fracture risk, and there is still a great possibility for improvement. The purpose of this paper is to identify key issues that need be addressed to improve image-based biomechanical modeling. MATERIALS AND METHODS: We critically examined issues in consideration and determination of the four biomechanical variables, i.e., risk of fall, fall-induced impact force, bone geometry and bone material quality, which are essential for prediction of hip fracture risk. We closely inspected: limitations introduced by assumptions that are adopted in existing models; deficiencies in methods for construction of biomechanical models, especially for determination of bone material properties from bone images; problems caused by separate use of the variables in clinical study of hip fracture risk; availability of clinical information that are required for validation of biomechanical models. RESULTS AND CONCLUSIONS: A number of critical issues and gaps were identified. Strategies for effectively addressing the issues were discussed.


Assuntos
Fraturas do Quadril/epidemiologia , Fraturas do Quadril/fisiopatologia , Modelos Biológicos , Acidentes por Quedas/prevenção & controle , Fenômenos Biomecânicos , Análise de Elementos Finitos , Fraturas do Quadril/diagnóstico por imagem , Humanos , Fatores de Risco
12.
Biomed Mater Eng ; 31(3): 179-190, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32597795

RESUMO

BACKGROUND: It is well known that there is a relationship between bone strength and the forces that are daily applied to the bone. However, bone is a highly heterogeneous material and it is still not clear how mechanical variables regulate the distribution of bone mass in a femur. METHODS: We studied the role of four mechanical variables, i.e. principal tensile/compressive stress, von Mises stress, and strain energy density (SED), in the regulation of bone mineral density (BMD) distribution in the human femur. The actual BMD in a femur was extracted from quantitative computed tomography (QCT) and used as a reference for comparison. A finite element model of the femur was constructed from the same set of QCT scans and then used in iterative simulations of femur remodeling under stance and walking loading. The finite element model was initially assigned a homogeneous BMD distribution. During the remodeling, femur BMD was locally modified according to one of the four mechanical variables. The simulations were stopped when BMD change in two consecutive iterations was adequately small. The four simulated BMD patterns were then compared with the actual BMD. RESULTS: It was found that the BMD pattern regulated by SED had the best similarity with the actual BMD. The medullary canal was successfully reproduced by simulated remodeling, indicating that in addition to its biological functions, the medullary canal has important biomechanical functions. CONCLUSIONS: Both the actual and simulated BMD distributions showed that the proximal femur has much lower BMD than the femur shaft, which may explain why hip fractures most often occur at the proximal femur.


Assuntos
Densidade Óssea/fisiologia , Remodelação Óssea/fisiologia , Fêmur/fisiologia , Suporte de Carga/fisiologia , Atividades Cotidianas , Idoso , Fenômenos Biomecânicos , Fêmur/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiologia , Análise de Elementos Finitos , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Posição Ortostática , Estresse Mecânico , Caminhada/fisiologia
13.
J Clin Densitom ; 22(3): 338-345, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30852033

RESUMO

OBJECTIVE: Finite element analysis (FEA) is a computational method to predict the behavior of materials under applied loading. We developed a software tool that automatically performs FEA on dual-energy X-ray absorptiometry hip scans to generate site-specific fracture risk indices (FRIs) that reflect the likelihood of hip fracture from a sideways fall. This longitudinal study examined associations between FRIs and incident fractures. METHODS: Using the Manitoba Bone Mineral Density (BMD) Registry, femoral neck (FN), intertrochanter (IT), and subtrochanter (ST) FRIs were automatically derived from 13,978 anonymized dual-energy X-ray absorptiometry scans (Prodigy, GE Healthcare) in women and men aged 50 yr or older (mean age 65 yr). Baseline covariates and incident fractures were assessed from population-based data. We compared c-statistics for FRIs vs FN BMD alone and fracture risk assessment (FRAX) probability computed with BMD. Cox regression was used to estimate hazard ratios and 95% confidence intervals (95% CIs) for incident hip, major osteoporotic fracture (MOF) and non-hip MOF adjusted for relevant covariates including age, sex, FN BMD, FRAX probability, FRAX risk factors, and hip axis length (HAL). RESULTS: During mean follow-up of 6 yr, there were 268 subjects with incident hip fractures, 1003 with incident MOF, and 787 with incident non-hip MOF. All FRIs gave significant stratification for hip fracture (c-statistics FN-FRI: 0.76, 95% CI 0.73-0.79, IT-FRI 0.74, 0.71-0.77; ST-FRI 0.72, 0.69-0.75). FRIs continued to predict hip fracture risk even after adjustment for age and sex (hazard ratio per standard deviation FN-FRI 1.89, 95% CI 1.66-2.16); age, sex, and BMD (1.26, 1.07-1.48); FRAX probability (1.30, 1.11-1.52); FRAX probability with HAL (1.26, 1.05-1.51); and individual FRAX risk factors (1.32, 1.09-1.59). FRIs also predicted MOF and non-hip MOF, but the prediction was not as strong as for hip fracture. SUMMARY: Automatically-derived FN, IT, and ST FRIs are associated with incident hip fracture independent of multiple covariates, including FN BMD, FRAX probability and risk factors, and HAL.


Assuntos
Densidade Óssea , Fraturas do Colo Femoral/epidemiologia , Quadril/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Absorciometria de Fóton , Acidentes por Quedas , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Fêmur/epidemiologia , Análise de Elementos Finitos , Traumatismos do Antebraço/epidemiologia , Fraturas do Quadril/epidemiologia , Humanos , Fraturas do Úmero/epidemiologia , Incidência , Masculino , Manitoba/epidemiologia , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Medição de Risco , Software , Fraturas da Coluna Vertebral/epidemiologia
14.
Clin Biomech (Bristol, Avon) ; 63: 48-53, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30831432

RESUMO

BACKGROUND: Clinicians have been looking for a simple and effective biomechanical tool for the assessment of hip fracture risk. Dual-energy X-ray absorptiometry (DXA) is currently the primary bone imaging modality in clinic, and the engineering beam is the simplest model for a mechanical analysis. Therefore, we developed a DXA-based beam model for the above purpose. METHODS: A beam model of the proximal femur was constructed from the subject's hip DXA image and denoted DXA-beam. Femur stiffness was calculated at cross-sections of interest using areal bone-mineral-density profile. Impact force induced in a sideways fall was applied as a critical loading. Fracture risk index at a cross-section was defined as the ratio of strain-energy induced by the impact force to the allowable strain-energy. A clinic cohort was used to study the discriminability of DXA-beam, which was measured by the area under the curve and odds ratio, both with 95% confidential interval. FINDINGS: Fracture risk measured by DXA-beam model at the femoral neck [odds ratio 2.23, 95% confidence interval (1.83, 2.57)], inter-trochanter [2.49, (2.14, 3.25)] and sub-trochanter [2.82, (2.38, 3.51)] were strongly associated with hip fracture. The area under the curve by DXA-beam at the femoral neck [0.74, 95% confidence interval (0.70, 0.76)], inter-trochanter [0.77, (0.75, 0.82)] and sub-trochanter [0.76, (0.74, 0.81)] were higher than that by femoral neck bone mineral density [0.71, (0.65, 0.78)]. INTERPRETATION: The DXA-beam model is a simple and yet effective mechanical model. It had promising performance in discrimination of fracture cases from controls.


Assuntos
Fêmur/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Medição de Risco , Absorciometria de Fóton , Acidentes por Quedas , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Estudos de Coortes , Estudos Transversais , Feminino , Colo do Fêmur , Humanos , Masculino , Estresse Mecânico
15.
J Biomech ; 88: 64-71, 2019 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-30902414

RESUMO

Impact force induced in sideways falls is an important determinant of hip fracture risk. While body parameters may differently affect the magnitude of impact force in men and women, the effect of sex is not considered in existing impact force predictors. The objective of this study was to construct a female-specific equation to predict the fall-induced impact force applied to the hip and evaluate whether it could improve hip facture risk assessment. A previously developed human-body dynamic model was used to simulate falling of 80 women and determine the hip impact force. Results were then used to derive a female-specific equation between impact force and body parameters. The proposed female-specific equation and available non-sex-specific impact force predictors in the literature were integrated with a finite element model to discriminate hip fracture patients among 393 women (99 hip fractures; 294 non-fracture controls). Results of the implemented methods were compared to evaluate whether considering the effect of sex could improve the discrimination of females with and without a hip fracture. The area under the curve (AUC) and odds ratio (OR) for the assessed hip fracture risk by the proposed female-specific method (AUC = 0.799, OR = 4.22) were significantly (p<0.001) greater than those of non-sex-specific methods (the most accurate: AUC =0.750, OR =3.62). This study indicates that the proposed equation may be useful to improve hip fracture risk assessment for women.


Assuntos
Acidentes por Quedas , Modelos Biológicos , Caracteres Sexuais , Fenômenos Biomecânicos , Feminino , Fêmur/fisiologia , Fêmur/fisiopatologia , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Ossos Pélvicos/fisiologia , Ossos Pélvicos/fisiopatologia , Medição de Risco
16.
J Bone Miner Metab ; 37(2): 342-350, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29671044

RESUMO

Femur stiffness, for example axial and bending stiffness, integrates both geometric and material information of the bone, and thus can be an effective indicator of bone strength and hip fracture risk. Femur stiffness is ideally measured from quantitative computed tomography (QCT), but QCT is not recommended for routine clinical use due to the public concern about exposure to high-dosage radiation. Dual energy X-ray absorptiometry (DXA) is currently the primary imaging modality in clinic. However, DXA is two-dimensional and it is not clear whether DXA-estimated stiffness has adequate accuracy to replace its QCT counterpart for clinical application. This study investigated the accuracy of femur stiffness (axial and bending) estimated from CTXA (computed tomography X-ray absorptiometry) and DXA against those directly measured from QCT. Proximal-femur QCT and DXA from 67 subjects were acquired. For each femur, the QCT dataset was projected into CTXA using CTXA-Hip (Mindways Software, Inc., USA). Femur stiffness at the femoral neck and intertrochanter were then calculated from QCT, CTXA and DXA, respectively, and different elasticity-density relationships were considered in the calculation. Pearson correlations between QCT and CTXA/DXA measured stiffness were studied. The results showed that there were strong correlations between QCT and CTXA derived stiffness, although the correlations were affected by the adopted elasticity-density relationship. Correlations between QCT and DXA derived stiffness were much less strong, mainly caused by the inconsistence of femur orientation in QCT projection and in DXA positioning. Our preliminary clinical study showed that femur stiffness had slightly better performance than femur geometry in discrimination of hip fracture cases from controls.


Assuntos
Absorciometria de Fóton , Fêmur/diagnóstico por imagem , Fêmur/fisiopatologia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/epidemiologia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Fenômenos Biomecânicos , Densidade Óssea , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fatores de Risco
17.
Comput Methods Programs Biomed ; 155: 75-83, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29512506

RESUMO

Finite element analysis of medical images is a promising tool for assessing hip fracture risk. Although a number of finite element models have been developed for this purpose, none of them have been routinely used in clinic. The main reason is that the computer programs that implement the finite element models have not been completely automated, and heavy training is required before clinicians can effectively use them. By using information embedded in clinical dual energy X-ray absorptiometry (DXA), we completely automated a DXA-based finite element (FE) model that we previously developed for predicting hip fracture risk. The automated FE tool can be run as a standalone computer program with the subject's raw hip DXA image as input. The automated FE tool had greatly improved short-term precision compared with the semi-automated version. To validate the automated FE tool, a clinical cohort consisting of 100 prior hip fracture cases and 300 matched controls was obtained from a local community clinical center. Both the automated FE tool and femoral bone mineral density (BMD) were applied to discriminate the fracture cases from the controls. Femoral BMD is the gold standard reference recommended by the World Health Organization for screening osteoporosis and for assessing hip fracture risk. The accuracy was measured by the area under ROC curve (AUC) and odds ratio (OR). Compared with femoral BMD (AUC = 0.71, OR = 2.07), the automated FE tool had a considerably improved accuracy (AUC = 0.78, OR = 2.61 at the trochanter). This work made a large step toward applying our DXA-based FE model as a routine clinical tool for the assessment of hip fracture risk. Furthermore, the automated computer program can be embedded into a web-site as an internet application.


Assuntos
Absorciometria de Fóton/métodos , Fraturas do Quadril/epidemiologia , Software , Acidentes por Quedas , Algoritmos , Automação , Densidade Óssea , Estudos de Casos e Controles , Estudos de Coortes , Análise de Elementos Finitos , Fraturas do Quadril/diagnóstico por imagem , Humanos , Internet , Reprodutibilidade dos Testes , Medição de Risco
18.
Bone ; 110: 386-391, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29526781

RESUMO

BACKGROUND: Dual-energy X-ray absorptiometry (DXA)-based finite element analysis (FEA) has been studied for assessment of hip fracture risk. Femoral strength (FS) is the maximum force that the femur can sustain before its weakest region reaches the yielding limit. Fracture risk index (FRI), which also considers subject-specific impact force, is defined as the ratio of von Mises stress induced by a sideways fall to the bone yield stress over the proximal femur. We compared risk stratification for prior hip fracture using FS and FRI derived from DXA-based FEA. METHODS: The study cohort included women aged ≥65years undergoing baseline hip DXA, with femoral neck T-scores <-1 and no osteoporosis treatment; 324 cases had prior hip fracture and 655 controls had no prior fracture. Using anonymized DXA hip scans, we measured FS and FRI. Separate multivariable logistic regression models were used to estimate odds ratios (ORs), c-statistics and their 95% confidence intervals (95% CIs) for the association of hip fracture with FS and FRI. RESULTS: Increased hip fracture risk was associated with lower FS (OR per SD 1.36, 95% CI: 1.15, 1.62) and higher FRI (OR per SD 1.99, 95% CI: 1.63, 2.43) after adjusting for Fracture Risk Assessment Tool (FRAX) hip fracture probability computed with bone mineral density (BMD). The c-statistic for the model containing FS (0.69; 95% CI: 0.65, 0.72) was lower than the c-statistic for the model with FRI (0.77; 95% CI: 0.74, 0.80) or femoral neck BMD (0.74; 95% CI: 0.71, 0.77; all P<0.05). CONCLUSIONS: FS and FRI were independently associated with hip fracture, but there were differences in performance characteristics.


Assuntos
Absorciometria de Fóton/métodos , Análise de Elementos Finitos , Fraturas do Quadril/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Estudos Transversais , Feminino , Humanos , Modelos Logísticos , Masculino
19.
Proc Inst Mech Eng H ; 232(1): 90-100, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29191076

RESUMO

Contact pressure and stresses on the articulating surface of the tibial component of a total knee replacement are directly related to the joint contact forces and the contact area. These stresses can result in wear and fatigue damage of the ultra-high-molecular-weight polyethylene. Therefore, conducting stress analysis on a newly designed surface-guided knee implant is necessary to evaluate the design with respect to the polyethylene wear. Finite element modeling is used to analyze the design's performance in level walking, stair ascending and squatting. Two different constitutive material models have been used for the tibia component to evaluate the effect of material properties on the stress distribution. The contact pressure results of the finite element analysis are compared with the results of contact pressure using pressure-sensitive film tests. In both analyses, the average contact pressure remains below the material limits of ultra-high-molecular-weight polyethylene insert. The peak von Mises stresses in 90° of flexion and 120° of flexion (squatting) are 16.28 and 29.55 MPa, respectively. All the peak stresses are less than the fatigue failure limit of ultra-high-molecular-weight polyethylene which is 32 MPa. The average contact pressure during 90° and 120° of flexion in squatting are 5.51 and 5.46 MPa according to finite element analysis and 5.67 and 8.14 MPa according to pressure-sensitive film experiment. Surface-guided knee implants are aimed to resolve the limitations in activities of daily living after total knee replacement by providing close to normal kinematics. The proposed knee implant model provides patterns of motion much closer to the natural target, especially as the knee flexes to higher degrees during squatting.


Assuntos
Análise de Elementos Finitos , Prótese do Joelho , Teste de Materiais , Atividades Cotidianas , Elasticidade , Estresse Mecânico , Propriedades de Superfície , Tíbia/citologia , Tíbia/fisiologia , Caminhada
20.
Biomed Eng Online ; 16(1): 116, 2017 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-28974207

RESUMO

BACKGROUND: Hip fracture of elderly people-suffering from osteoporosis-is a severe public health concern, which can be reduced by providing a prior assessment of hip fracture risk. Image-based finite element analysis (FEA) has been considered an effective computational tool to assess the hip fracture risk. Considering the femoral neck region is the weakest, fracture risk indicators (FRI) are evaluated for both single-legged stance and sideways fall configurations and are compared between left and right femurs of each subject. Quantitative Computed Tomography (QCT) scan datasets of thirty anonymous patients' left and right femora have been considered for the FE models, which have been simulated with an equal magnitude of load applied to the aforementioned configurations. The requirement of bilateral hip assessment in predicting the fracture risk has been explored in this study. RESULTS: Comparing the sideways fall and single-legged stance, the FRI varies by 64 to 74% at the superior aspects and by 14 to 19% at the inferior surfaces of both the femora. The results of this in vivo analysis clearly substantiate that the fracture is expected to initiate at the superior surface of femoral neck region if a patient falls from his/her standing height. The distributions of FRI between the femurs vary considerably, and the variability is significant at the superior aspects. The p value (= 0.02) obtained from paired sample t-Test yields p value ≤ 0.05, which shows the evidence of variability of the FRI distribution between left and right femurs. Moreover, the comparison of FRIs between the left and right femur of men and women shows that women are more susceptible to hip fracture than men. CONCLUSIONS: The results and statistical variation clearly signify a need for bilateral hip scanning in predicting hip fracture risk, which is clinically conducted, at present, based on one hip chosen randomly and may lead to inaccurate fracture prediction. This study, although preliminary, may play a crucial role in assessing the hip fractures of the geriatric population and thereby, reducing the cost of treatment by taking predictive measure.


Assuntos
Acidentes por Quedas , Fêmur/diagnóstico por imagem , Fêmur/lesões , Análise de Elementos Finitos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/etiologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA