1.
Hip Int ; 29(3): 262-269, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30378457

RESUMO

INTRODUCTION: In total hip arthroplasty (THA), local adverse reaction to metal debris (ARMD) may be caused by abnormal metal ion release from a metal-on-metal (MoM) bearing, or by wear and corrosion of the implant's modular junction. The aim of this study was to compare ion levels and rate of ARMD between patients sharing the same MoM bearing but 1 group having monoblock stems versus another having modular stems. MATERIALS AND METHODS: Whole blood cobalt (Co) and chromium (Cr) ion concentrations, ARMD rate, revision rate, and function measured by UCLA and WOMAC scores were compared between groups. RESULTS: ARMD rate was significantly higher in the modular group (46%) compared with the monoblock group (16%, p = 0.031). Revision for ARMD was performed at 52.8 ± 8.1 months in the modular group versus 98.2 ± 15.5 months after primary THA in the monoblock group. ARMD originated from wear and corrosion of the junction between stem and femoral head adapter sleeve in all monoblock cases, and the junction between stem and modular neck in all the modular ones. Cr and Co ions levels were significantly higher in the modular stem group ( p < 0.001 for both). CONCLUSIONS: Although both groups had MoM bearings, corrosion at stem/neck or neck/head junctions combining dissimilar metal (Ti and Cr-Co) was seen as the source of excess metal ions release leading to ARMD. Poor performance of the modular junction may be more deleterious than wear of the bearing. To avoid such complications, THA femoral stem modular junctions should be eliminated (return to a full monoblock implant) or have improved junction design.


Assuntos
Artroplastia de Quadril/métodos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Adulto , Idoso , Biomarcadores/sangue , Corrosão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
2.
J Arthroplasty ; 26(2): 282-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20206466

RESUMO

Preoperative and postoperative ion concentrations were measured in 29 metal-on-metal, large-diameter head total hip arthroplasty (LDH-THA) patients. Mean chromium, cobalt (Co), and titanium levels from LDH-THA were 1.3, 2.2, and 2.7 µg/L at 12 months. The open femoral head design showed significantly higher Co concentrations than the closed design (3.0 vs 1.8 µg/L, P = .037). Compared with previously published ion levels from a hip resurfacing system presenting the same bearing characteristics, Co levels were significantly higher in LDH-THA (2.2 vs 0.7 µg/L, P < .001). This study has demonstrated that the addition of a sleeve with modular junctions and an open femoral head design of LDH-THA causes more Co release than bearing surface wear (157% and 67%, respectively). Even if no pathologic metal ion threshold level has been determined, efforts should be made to minimize its release. We recommend modification or abandonment of the modular junction and femoral head open design for this specific LDH-THA system.


Assuntos
Cromo/sangue , Cobalto/sangue , Prótese de Quadril , Titânio/sangue , Adulto , Artroplastia de Quadril , Feminino , Humanos , Masculino , Metais , Estudos Prospectivos , Desenho de Prótese , Adulto Jovem
3.
Hip Int ; 20(1): 1-13, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20235065

RESUMO

Two hundred and nine hips were randomised to receive either a 28 mm total hip athroplasty (THA, 100 hips) or hybrid hip resurfacing (HR, 109 hips). At 1 and 2 years post-operatively, patients with HR achieved statistically significantly better WOMAC functional scores. However, differences in scores were of slight clinical relevance with a difference of 2.2/100 and 3.3/100, at 1 and 2 years respectively (p=0.007). After an average follow-up of 56 months (range 36-72) there were similar re-operation rates 7/100 THA and 6/109 HR (p=0.655) and revision rates 2/100 THA and 4/109 HR (p=0.470). However, the types of complications were different. Higher early aseptic loosening rate was found in HR and long-term survival analysis of both patient cohorts is necessary to determine whether the potential bone preservation advantage offers by HR will overcome its earlier higher failure rate.


Assuntos
Artroplastia de Quadril/métodos , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Método Duplo-Cego , Feminino , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS