Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 15(20)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36295241

RESUMO

Present commercial titanium alloy implants have an elastic modulus higher than 100 GPa, whereas that of the cortical bone is much smaller (17−28 GPa). This elastic modulus mismatch produces a stress shielding effect and the resorption of the bone surrounding the implant. In the present work, a <100> fiber texture is developed in ß type Ti-42Nb (wt%) alloy ingots generated by laser-directed energy deposition (LDED) in order to achieve anisotropic mechanical properties. In addition, we demonstrate that laser-deposited ß type Ti-42Nb alloy ingots with an intense <100> fiber texture exhibit a very low elastic modulus in the building direction (Ez < 50 GPa) and high yield (σ0.2z > 700 MPa) and tensile (UTSz > 700 MPa) strengths. Laser-deposited Ti-42Nb alloy enhances the osteoinductive effect, promoting the adhesion, proliferation, and spreading of human osteoblast-like cells. Hence, we propose that laser-deposited ß type Ti-42Nb alloy is a potentially promising candidate for the manufacturing of pioneering biomedical implants with a very low elastic modulus that can suppress stress shielding.

2.
Int J Mol Sci ; 23(19)2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36233328

RESUMO

Implant-associated infection due to biofilm formation is a growing problem. Given that silver nanoparticles (Ag-NPs) have shown antibacterial effects, our goal is to study their effect against multispecies biofilm involved in the development of peri-implantitis. To this purpose, Ag-NPs were synthesized by laser ablation in de-ionized water using two different lasers, leading to the production of colloidal suspensions. Subsequently, part of each suspension was subjected to irradiation one and three times with the same laser source with which it was obtained. Ag-NPs were immobilized on the surface of titanium discs and the resultant materials were compared with unmodified titanium coupons. Nanoparticles were physico-chemically analysed to determine their shape, crystallinity, chemical composition, and mean diameter. The materials were incubated for 90 min or 48 h, to evaluate bacterial adhesion or biofilm formation respectively with Staphylococcus aureus or oral mixed bacterial flora composed of Streptococcus oralis, Actinomyces naeslundii, Veionella dispar, and Porphyromonas gingivalis. Ag-NPs help prevent the formation of biofilms both by S. aureus and by mixed oral bacterial flora. Nanoparticles re-irradiated three times showed the biggest antimicrobial effects. Modifying dental implants in this way could prevent the development of peri-implantitis.


Assuntos
Implantes Dentários , Terapia a Laser , Nanopartículas Metálicas , Peri-Implantite , Reirradiação , Antibacterianos/farmacologia , Biofilmes , Humanos , Peri-Implantite/prevenção & controle , Porphyromonas gingivalis , Prata/farmacologia , Staphylococcus aureus , Suspensões , Titânio/química , Titânio/farmacologia , Água/farmacologia
3.
Materials (Basel) ; 15(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35806747

RESUMO

Laser-directed energy deposition (LDED) is an additive manufacturing (AM) technology which can be an alternative to the traditional subtractive milling process for the obtention of porcelain-fused-to-metal (PFM) prosthesis. Still, the adhesion performance of the veneering ceramics for this material has been not studied yet. The main objective of this study is to perform a systematic comparison of the adhesion performance of Co-Cr-W metal frameworks obtained through LDED and conventional milling techniques. Comparison includes microstructural, superficial, and adhesion analysis. Co-Cr manufactured via LDED technique presents similar behavior (p < 0.05) in comparison to the material obtained via milling techniques, and its performance was validated with the veneering ceramics and veneering composites currently employed in the dental industry.

4.
Mater Sci Eng C Mater Biol Appl ; 126: 112124, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34082941

RESUMO

The repair of articular cartilage lesions in weight-bearing joints remains as a significant challenge due to the low regenerative capacity of this tissue. Hydrogels are candidates to repair lesions as they have similar properties to cartilage extracellular matrix but they are unable to meet the mechanical and biological requirements for a successful outcome. Here, we reinforce hyaluronic acid (HA) hydrogels with 13-93-lithium bioactive glass micro- and nanofibres produced by laser spinning. The glass fibres are a reinforcement filler and a platform for the delivery of therapeutic lithium-ions. The elastic modulus of the composites is more than three times higher than in HA hydrogels. Modelling of the reinforcement corroborates the experimental results. ATDC5 chondrogenic cells seeded on the composites are viable and more proliferation occurs on the hydrogels containing fibres than in HA hydrogels alone. Furthermore, the chondrogenic behavior on HA constructs with fibres containing lithium is more marked than in hydrogels with no-lithium fibres.


Assuntos
Ácido Hialurônico , Nanofibras , Hidrogéis , Lasers , Lítio
5.
Small ; 17(18): e2100924, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33760359

RESUMO

Despite corrosion being commonly seen as a problem to be avoided, applications such as batteries or biodegradable implants do benefit from corrosion-like phenomena. However, current strategies address corrosion control from a global perspective for a whole component, without considering local adaptations to functionality specifications or inhomogeneous environments. Here, a novel concept is presented: the local control and guidance of corrosion through a laser surface treatment. Immersion tests in saline solution of AZ31 magnesium alloy samples show degradation rates reduced up to 15 times with the treatment, owing to a fast passivation after the induced microstructural modifications. By controlling the treatment conditions, the degradation can be restricted to delimited regions and driven towards specific directions. The applicability of the method for the design of tailored degradation biomedical implants is demonstrated and uses for cathodic protection systems and batteries can also be anticipated.


Assuntos
Ligas , Magnésio , Implantes Absorvíveis , Corrosão , Lasers , Teste de Materiais
6.
Materials (Basel) ; 12(3)2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30695996

RESUMO

Slate is a natural rock usually used in roofs, façades, and for tiling. In spite of this broad use, the production process of slate tiles requires substantial improvements. An important quantity of slate from the quarry is wasted during the manufacturing of the final product. Furthermore, processes are not automatized and the production lead times can be considerably shortened. Therefore, new processing methods to increase productivity, reduce costs and to provide added value to the final slate product are required. Drilling is an important part of these manufacturing processes. Conventional drilling processes usually cause the breaking of the slate tiles; then, even a higher quantity of material is wasted. To overcome these problems, lasers emerge as a feasible tool to produce holes in this material, since mechanical stresses are not induced on the workpiece. In this work, we have studied the CO2 laser microdrilling of slate tiles. We used a Design of Experiments (DOE) methodology to determine the influence of the laser processing parameters on the hole quality. This work demonstrates the capability of a CO2 laser to produce holes in slate with less than 100 microns in diameter, avoiding any fracture, and with a processing time of less than 50 ms per hole. Finally, this process demonstrates the viability of the production of high-density micron-sized holes in a slate tile for water draining purposes.

7.
Materials (Basel) ; 12(1)2019 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-30621346

RESUMO

Assist gas plays a central role in laser fusion cutting. In this work, the aerodynamic interactions between the assist gas and the workpiece are reviewed. An insight into those phenomena that hinder the cutting quality and performance is provided. These phenomena include shock waves, choking, boundary layer separation, etc. The most relevant and promising attempts to overcome these common problems related to the gas dynamics are surveyed. The review of the current scientific literature has revealed some gaps in the current knowledge of the role of the assist gas dynamics in laser cutting. The assist gas interactions have been investigated only under static conditions; and the dynamic interaction with the molten material on the cutting front has not been addressed. New nozzle designs with improved efficiency of molten material removal are required to improve cut quality; and cutting speed in current industrial laser cutting machines; especially in those assisted by new high-brightness laser sources.

8.
Sci Rep ; 5: 10677, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-26032983

RESUMO

Craniofacial reconstructive surgery requires a bioactive bone implant capable to provide a gradual resorbability and to adjust to the kinetics of new bone formation during healing. Biomaterials made of calcium phosphate or bioactive glasses are currently available, mainly as bone defect fillers, but it is still required a versatile processing technique to fabricate composition-gradient bioceramics for application as controlled resorption implants. Here it is reported the application of rapid prototyping based on laser cladding to produce three-dimensional bioceramic implants comprising of a calcium phosphate inner core, with moderate in vitro degradation at physiological pH, surrounded by a bioactive glass outer layer of higher degradability. Each component of the implant is validated in terms of chemical and physical properties, and absence of toxicity. Pre-osteoblastic cell adhesion and proliferation assays reveal the adherence and growth of new bone cells on the material. This technique affords implants with gradual-resorbability for restoration of low-load-bearing bone.


Assuntos
Substitutos Ósseos , Cerâmica , Próteses e Implantes , Fosfatos de Cálcio , Vidro/química , Lasers , Teste de Materiais , Próteses e Implantes/ultraestrutura , Reprodutibilidade dos Testes
9.
Nanoscale Res Lett ; 6(1): 255, 2011 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-21711800

RESUMO

Laser ablation of solids in liquids technique has been used to obtain colloidal nanoparticles from biological hydroxylapatite using pulsed as well as a continuous wave (CW) laser. Transmission electron microscopy (TEM) measurements revealed the formation of spherical particles with size distribution ranging from few nanometers to hundred nanometers and irregular submicronic particles. High resolution TEM showed that particles obtained by the use of pulsed laser were crystalline, while those obtained by the use of CW laser were amorphous. The shape and size of particles are consistent with the explosive ejection as formation mechanism.

10.
Int J Sports Physiol Perform ; 6(1): 82-93, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21487152

RESUMO

PURPOSE: Countermovement jump (CMJ) and maximum running speed over a distance of 20 m were evaluated for examination of the concurrent fatigue and postactivation potentiation (PAP) in endurance athletes after an incremental field running test. METHODS: Twenty-two endurance athletes performed two attempts of CMJ on a force plate and maximum running speed test before and following the Université de Montréal Track Test (UMTT). RESULTS: The results showed an improvement in CMJ height (3.6%) after UMTT that correlated with the increment in peak power (3.4%), with a concurrent peak force loss (-10.8%) that correlated with peak power enhancement. The athletes maintained their 20 m sprint performance after exhaustion. Cluster analysis reinforced the association between CMJ and peak power increments in responders with a reported correlation between peak power and sprint performance increments (r = .623; P = .041); nonresponders showed an impairment of peak force, vertical stiffness, and a higher vertical displacement of the center of mass during the countermovement that correlated with lactate concentration (r = -0.717; P = .02). CONCLUSIONS: It can be suggested that PAP could counteract the peak force loss after exhaustion, allowing the enhancement of CMJ performance and the maintenance of sprint ability in endurance athletes after the UMTT. From these results, the evaluation of CMJ after incremental running tests for the assessment of muscular adaptations in endurance athletes can be recommended.


Assuntos
Contração Muscular , Fadiga Muscular , Músculo Esquelético/fisiologia , Resistência Física , Adaptação Fisiológica , Adolescente , Adulto , Biomarcadores/sangue , Fenômenos Biomecânicos , Análise por Conglomerados , Teste de Esforço , Humanos , Ácido Láctico/sangue , Masculino , Recuperação de Função Fisiológica , Corrida , Análise e Desempenho de Tarefas , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA