Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 56(5): 1487-508, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21321387

RESUMO

We have produced an optically clear, close to water-equivalent gel that is radio-fluorogenic, i.e. fluoresces in UV light after exposure to high-energy radiation. Its potential as a 2D and 3D dosimetric medium is demonstrated by fixed fluorescent images of the cross-section, track and intersection of collimated (10 × 10 or 5 × 5 mm(2)) 205 kVp x-ray beams. The images, produced by doses on the order of 10 Gy, are formed instantaneously and can be digitally recorded and scanned with a spatial resolution on the order of 0.1 mm. No loss of spatial resolution occurs on standing under ambient conditions for at least 3 days.


Assuntos
Corantes Fluorescentes/química , Polimerização , Monitoramento de Radiação/métodos , Géis , Maleimidas/química , Monitoramento de Radiação/instrumentação , Raios Ultravioleta , Raios X
2.
Phys Med Biol ; 54(10): 3185-200, 2009 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-19420430

RESUMO

A method of radiation dosimetry is described which is based on the radiation-induced initiation of polymerization of a bulk monomer (e.g. methyl methacrylate) containing a small concentration (about 100 ppm) of a compound which is non-fluorescent but which becomes highly fluorescent when it is incorporated into a growing polymer chain of the bulk monomer. We call the overall process 'radio-fluorogenic co-polymerization' or RFCP for short. The method is illustrated by results on the in situ monitoring of the accumulated dose within the irradiation chamber of a cobalt-60 gamma-ray source using a small plastic capsule containing about 0.2 ml of an RFCP solution. Remote monitoring of the fluorescence is carried out on a timescale of seconds using optical fibres connecting the probe to a 360 nm LED excitation source and a miniature spectrophotometer. The fluorescence is permanent and the intensity is linearly proportional to the accumulated dose from a few tenths of a gray up to hundreds of gray. The sensitivity to dose depends on the polymerizable monomer used and obeys a square root dependence on dose rate over the range studied, 0.27-3.76 Gy min(-1). The polymeric nature of the fluorescent product suggests that the RFCP effect could be used to provide fixed two- or three-dimensional fluorescent images of dose deposition in gel films or phantoms.


Assuntos
Polímeros/química , Polímeros/efeitos da radiação , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Biochim Biophys Acta ; 1393(1): 137-42, 1998 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-9714777

RESUMO

Dihydroxyacetonephosphate acyltransferase (DHAP-acyltransferase) and alkyl-dihydroxyacetonephosphate synthase (alkyl-DHAP synthase) are the first two enzymes involved in the biosynthesis of ether phospholipids. Both peroxisomal enzymes have recently been purified to homogeneity and their molecular weights under denaturing conditions were reported. To determine the in situ functional size of both enzymes, radiation inactivation experiments were performed. Alkyl-DHAP synthase showed single exponential decays, both when enzymatic activity and when immunoreactive protein levels were measured, from which target sizes of 79+/-2 kDa and 78+/-4 kDa, respectively, were calculated. DHAP-acyltransferase activity increased at lower doses and decayed upon further irradiation with an apparent target size of 62+/-7 kDa. We conclude from these data that the functional unit sizes for both enzymes in situ are represented by their single polypeptide chains.


Assuntos
Aciltransferases/química , Alquil e Aril Transferases/química , Fígado/enzimologia , Proteínas de Membrana/química , Análise por Ativação , Animais , Cobaias , Microcorpos/enzimologia , Peso Molecular
4.
Biochem J ; 318 ( Pt 2): 463-7, 1996 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-8809034

RESUMO

Lipoprotein lipase (LPL) is functionally active only as a dimer. It is also generally assumed that the highly homologous hepatic lipase functions as a dimer, but no clear evidence has been presented. A hepatic lipase-like activity, also indicated as L-type lipase, is present in adrenal and ovary tissues. This enzyme is thought to originate from the liver and to be identical to hepatic lipase. We determined the functional molecular mass of hepatic lipase in rat liver, adrenal gland and ovary by radiation inactivation, a method for determining the functional size of a protein without the need of prior purification. Samples were exposed to ionizing radiation at -135 degrees C. Hepatic lipase activity in liver homogenate showed a single exponential decay. The functional molecular mass was calculated to be 63 +/- 10 kDa. Hepatic lipase activity in adrenal homogenate was found to have a functional molecular mass of 117 +/- 16 kDa. The functional molecular masses of the lipases partially purified from rat liver perfusate, adrenal homogenate or ovarian homogenate showed the same pattern, a target mass for the liver enzyme of 56 +/- 6 kDa and a target mass of 117 +/- 14 kDa for the enzyme from adrenal gland or ovary. In Western blot analysis the mass of the structural units of hepatic lipase in liver was 57 kDa and in adrenal and ovary tissue 51 kDa. We conclude that the functional unit of hepatic lipase in the liver is a monomer. The enzyme in adrenal gland and ovary is different from the liver and the functional unit may be a dimer.


Assuntos
Glândulas Suprarrenais/enzimologia , Lipase/química , Fígado/enzimologia , Ovário/enzimologia , Animais , Western Blotting , Relação Dose-Resposta à Radiação , Eletroforese em Gel de Poliacrilamida , Feminino , Cinética , Lipase/antagonistas & inibidores , Lipase/efeitos da radiação , Masculino , Peso Molecular , Especificidade de Órgãos , Ratos , Ratos Wistar
5.
J Biol Chem ; 269(23): 16409-15, 1994 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-7911466

RESUMO

Guanylyl cyclase (GC) C is a heat-stable enterotoxin (STa) receptor with a monomeric M(r) of approximately 140,000. We calculated from its hydrodynamic parameters that an active GC-C complex has a M(r) of 393,000, suggesting that GC-C is a trimer under native conditions. Both trimeric and dimeric GC-C complexes were detected by 125I-STa binding and SDS-polyacrylamide gel electrophoresis under non-reducing conditions. The GC activity and STa binding from intestinal brush border membranes comigrated in gel filtration and velocity sedimentation with recombinant GC-C. However, 125I-STa cross-linking demonstrated that STa receptors with molecular masses of 52 and 74 kDa are non-covalently attached to GC in the intestine. Radiation inactivation revealed different functional sizes for basal GC activity, STa-stimulated GC activity, and STa binding (59, 210-240, and 32-52 kDa, respectively). At low radiation doses, basal GC activity was stimulated, suggesting that GC-C is inhibited by a relatively large, probably internal structure. These results suggest that STa may activate GC-C by promoting monomer-monomer interaction (internal "dimerization") within a homotrimeric GC-C complex, and that GC-C is proteolytically modified in the brush border membrane but retains its function.


Assuntos
Toxinas Bacterianas/metabolismo , Enterotoxinas/metabolismo , Guanilato Ciclase/química , Intestinos/enzimologia , Conformação Proteica , Receptores de Peptídeos/química , Animais , Reagentes de Ligações Cruzadas , Elétrons , Ativação Enzimática , Proteínas de Escherichia coli , Guanilato Ciclase/efeitos da radiação , Masculino , Microvilosidades/enzimologia , Modelos Biológicos , Peso Molecular , Ratos , Ratos Wistar , Receptores de Enterotoxina , Receptores Acoplados a Guanilato Ciclase , Receptores de Peptídeos/efeitos da radiação , Ultracentrifugação
6.
Biochem Biophys Res Commun ; 184(3): 1331-8, 1992 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-1375458

RESUMO

The functional unit size of the water channel in rabbit erythrocytes was assessed using target size analysis following radiation inactivation. Using Radiochromic nylon dosimetry, accurate values of accumulated dose yielded an absolute target analysis, leading to direct determination of molecular size. The erythrocyte water channel functional size was shown to be 30 kDa, and is identical to the size found in rat renal proximal tubule brush border membranes (1), suggesting close homology of these two water channels. The result suggests that the 28 kDa channel-like intrinsic protein (CHIP28) recently isolated from human erythrocytes and proximal tubule (2), which is believed to form water channels of oligomeric construction may have a functional water channel activity in monomeric form.


Assuntos
Membrana Eritrocítica/metabolismo , Canais Iônicos/metabolismo , Acetilcolinesterase/metabolismo , Acetilcolinesterase/efeitos da radiação , Fosfatase Alcalina/antagonistas & inibidores , Fosfatase Alcalina/metabolismo , Fosfatase Alcalina/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Membrana Eritrocítica/efeitos da radiação , Membrana Eritrocítica/ultraestrutura , Canais Iônicos/efeitos da radiação , Túbulos Renais Proximais/enzimologia , Cinética , Microvilosidades/enzimologia , Peso Molecular , Coelhos
7.
J Biol Chem ; 266(25): 16633-5, 1991 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-1885592

RESUMO

The high water permeability of kidney proximal tubules is of paramount importance for isotonic reabsorption of 70% of the glomerular filtrate, and water channels have been postulated to account for the high water permeability. Target analysis following radiation inactivation was used to probe the molecular size of the water channel. Samples of brush border membranes from rat renal cortex were subjected to 3-MeV electron pulses from the Van de Graaff accelerator at a temperature of -130 degrees C. The inactivation of the renal brush border enzymes, alkaline phosphatase, and maltase was used for internal standardization of accumulated dose measurements in target analysis of the water channel. Osmotic water permeability was measured by following the change in scattered light intensity upon rapid mixing of vesicles with a hypertonic solution using stopped-flow spectrophotometry. The vesicle shrinkage response was biphasic and the rate of the fast phase decreased dose dependently by irradiation corresponding to a target size of 30 +/- 3.5 kDa. The total change in scattered light intensity was unaltered, indicating that irradiation did not destroy the lipid barrier. Our results provide strong support for the hypothesis that the high osmotic water permeability of renal proximal tubules results from a water channel-specific protein with a functional unit of 30 kDa.


Assuntos
Água Corporal/metabolismo , Túbulos Renais Proximais/metabolismo , Fosfatase Alcalina/metabolismo , Animais , Permeabilidade da Membrana Celular , Elétrons , Túbulos Renais Proximais/enzimologia , Túbulos Renais Proximais/efeitos da radiação , Cinética , Luz , Microvilosidades/enzimologia , Microvilosidades/metabolismo , Microvilosidades/efeitos da radiação , Peso Molecular , Osmose , Ratos , Espalhamento de Radiação , Temperatura
8.
Rev Sci Instrum ; 49(2): 230, 1978 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18699066

RESUMO

A passive coaxial pulse shaper has been developed which produces a subnanosecond duration pulse with short rise and decay time from a long pulse with short rise time. The mechanical construction of the pulse shaper is a modified coaxial air line T-section. The pulse shaper has been incorporated in the pulsing circuit of a 3-MV Van de Graaff accelerator. The form of the resulting electron beam pulses was monitored both as the charge collected by a coaxial target and as the Cerenkov light emitted by a quartz plate. In both cases sequential sampling techniques were used. The electron beam pulses were found to have rise and decay tiems of approxiamtely 100 ps and a half-width as short as approximately 200 ps could be obtained. An advantage of this method of producing subnanosecond beam pulses is that it does not interfere with normal nanosecond pulsed operation of the Van de Graaff.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...