Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ultraschall Med ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39117313

RESUMO

PURPOSE: Liver stiffness measurement (LSM) using vibration-controlled transient elastography (VCTE) or two-dimensional shear wave elastography (2D-SWE) is recommended to assess the risk of liver fibrosis and advanced chronic liver disease. Even though both techniques measure liver stiffness, their numerical results often diverge. Confounders and reliability criteria for 2D-SWE have not been systematically investigated. MATERIALS AND METHODS: We prospectively recruited participants with paired LSM by VCTE and the novel 2D-SWE technique ElastQ (Philips) in three European tertiary centers. The following parameters were recorded: sex, age, body mass index (BMI), etiology, laboratory markers of liver damage and function, as well as cholestasis, LSM by VCTE and controlled attenuation parameter (CAP), interquartile range (IQR)/median for VCTE-LSM and ElastQ-LSM, and the skin-to-liver capsule distance. RESULTS: We included 840 participants: 447 (53.2%) males; median age 57.0 [IQR:19.0] years; median BMI 25.4 [6.0] kg/m2; median VCTE-LSM 7.25 [9.2] kPa; median ElastQ-LSM 6.7 [5.4] kPa. On uni- and multivariable modeling (adjusted for LSM), we found that the discrepancy increased with liver stiffness and markers of disease severity. Skin-to-liver capsule distance and BMI affected VCTE-LSM more compared to ElastQ-LSM and significantly increased the discordance between the two measurements. CONCLUSION: The discrepancy of ElastQ-LSM to VCTE-LSM increases with liver stiffness and disease severity. BMI and skin-to-liver capsule distance increase the discrepancy between VCTE- and ElastQ-LSM but affect ElastQ-LSM less. The quality criterion IQR/median ≤ 30% indicates reliable ElastQ-LSM.

2.
Gastroenterology ; 165(4): 1041-1052, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37442301

RESUMO

BACKGROUND & AIMS: Liver stiffness measurements (LSMs) provide an opportunity to monitor liver disease progression and regression noninvasively. We aimed to determine the prognostic relevance of LSM dynamics over time for liver-related events and death in patients with chronic liver disease. METHODS: Patients with chronic liver disease undergoing 2 or more reliable LSMs at least 180 days apart were included in this retrospective cohort study and stratified at baseline (BL) as nonadvanced chronic liver disease (non-ACLD, BL-LSM < 10 kPa), compensated ACLD (cACLD; BL-LSM ≥ 10 kPa), and decompensated ACLD. Data on all consecutive LSMs and clinical outcomes were collected. RESULTS: There were 2508 patients with 8561 reliable LSMs (3 per patient; interquartile range, 2-4) included: 1647 (65.7%) with non-ACLD, 757 (30.2%) with cACLD, and 104 (4.1%) with decompensated ACLD. Seven non-ACLD patients (0.4%) and 83 patients with cACLD (10.9%) developed hepatic decompensation (median follow-up, 71 months). A 20% increase in LSM at any time was associated with an approximately 50% increased risk of hepatic decompensation (hazard ratio, 1.58; 95% CI, 1.41-1.79; P < .001) and liver-related death (hazard ratio, 1.45; 95% CI, 1.28-1.68; P < .001) in patients with cACLD. LSM dynamics yielded a high accuracy to predict hepatic decompensation in the following 12 months (area under the receiver operating characteristics curve = 0.933). The performance of LSM dynamics was numerically better than dynamics in Fibrosis-4 score (0.873), Model for End-Stage Liver Disease (0.835), and single time-point LSM (BL-LSM: 0.846; second LSM: 0.880). Any LSM decrease to <20 kPa identified patients with cACLD with a substantially lower risk of hepatic decompensation (hazard ratio, 0.13; 95% CI, 0.07-0.24). If reliable, LSM also confers prognostic information in decompensated ACLD. CONCLUSIONS: Repeating LSM enables an individual and updated risk assessment for decompensation and liver-related mortality in ACLD.


Assuntos
Técnicas de Imagem por Elasticidade , Doença Hepática Terminal , Hepatopatias , Humanos , Estudos Retrospectivos , Doença Hepática Terminal/complicações , Índice de Gravidade de Doença , Hepatopatias/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Medição de Risco , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia
3.
Ultraschall Med ; 44(2): 169-178, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35226932

RESUMO

BACKGROUND: Since nonalcoholic fatty liver disease (NAFLD) has become the leading cause of liver disease in the Western world, clinicians need reliable noninvasive tools for the identification of NAFLD-associated fibrosis. Limited evidence on the performance of the novel shear wave elastography technique Elast-PQ (EPQ) in NAFLD is available. METHOD: In this prospective, European multinational study we assessed the diagnostic accuracy of EPQ using vibration-controlled transient elastography (VCTE) as a reference standard. RESULTS: Among 353 NAFLD patients, 332 (94.1%) fulfilled reliability criteria of VCTE and EPQ (defined by IQR/median ≤0.3; 41.3% female, mean age: 59 [IQR: 16.5], mean BMI: 29.0 (7.1)). 4/353 (1.1%) and 17/353 (4.8%) had unreliable VCTE and EPQ measurements, respectively. VCTE-based NAFLD fibrosis stages were F0/F1: 222(66.9%), F2: 41 (12.3%), F3: 30 (9.1%), F4: 39 (11.7%). We found a strong correlation (Pearson R=0.87; p<0.0001) and concordance (Lin's concordance correlation coefficient =0.792) of EPQ with VCTE. EPQ was able to identify NAFLD-fibrosis risk with the following EPQ cutoffs: ≥6.5 kPa for significant fibrosis (≥F2) (≥1.47 m/s; sensitivity: 78%; specificity: 95%; AUROC: 0.94), ≥6.9 kPa for advanced fibrosis (≥F3) (≥1.52 m/s; sens.: 88%, spec.: 89%; AUROC: 0.949), and ≥10.4 kPa for cirrhosis (F4) (≥1.86 m/s; sens.: 87%; spec.: 94%; AUROC: 0.949). CONCLUSION: The point shear wave elastography technique EPQ shows excellent correlation to and concordance with VCTE. EPQ can reliably exclude NAFLD fibrosis <6.0 kPa (<1.41 m/s) and indicate a high risk of advanced fibrosis ≥10.4 kPa (≥1.86 m/s).


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Técnicas de Imagem por Elasticidade/métodos , Vibração , Reprodutibilidade dos Testes , Cirrose Hepática/diagnóstico por imagem , Fibrose , Fígado/diagnóstico por imagem
4.
J Pers Med ; 11(4)2021 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-33917196

RESUMO

Genetic variants including PNPLA3-rs738409 C>G, TM6SF2-rs58542926 C>T, MBOAT7-rs641738 C>T, and HSD17B13-rs72613567 T>TA have been shown to influence progression to advanced chronic liver disease (ACLD) in patients with chronic hepatitis C (CHC). We aimed to investigate their impact on disease regression (i.e., changes in hepatic venous pressure gradient [HVPG] and non-invasive surrogates [liver stiffness measurement (LSM), von Willebrand factor (VWF), and VWF/platelet count ratio (VITRO)]) and clinical outcomes after CHC cure in 346 patients with pre-treatment ACLD. Patients carrying the PNPLA3 minor allele had more advanced liver disease prior to antiviral therapy, confirming its impact on liver disease progression. In a subgroup of 88 patients who underwent paired HVPG-measurements and were genotyped for all SNP/indels, PNPLA3/TM6SF2/MBOAT7/HSD17B13 genotypes were not associated with changes in HVPG. In line, changes in non-invasive surrogates of portal hypertension (LSM/VWF/VITRO) were comparable between carriers and non-carriers of the PNPLA3 G-allele in the overall cohort. Finally, carriage of PNPLA3 G-allele was not associated with the development of hepatic decompensation, de-novo hepatocellular carcinoma, or transplant-free mortality during a median follow-up of 42 months after the end of antiviral treatment. Therefore, genetic variants in PNPLA3/TM6SF2/MBOAT7/HSD17B13 do not impact the regression of portal hypertension and clinical outcomes in patients with pre-treatment ACLD after CHC cure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA