Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 112(1): 135-48, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21940853

RESUMO

Changes in lung function and structure were studied using hyperpolarized (3)He MRI in an elastase-induced murine model of emphysema. The combined analysis of the apparent diffusion coefficient (ADC) and fractional ventilation (R) were used to distinguish emphysematous changes and also to develop a model for classifying sections of the lung into diseased and normal. Twelve healthy male BALB/c mice (26 ± 2 g) were randomized into healthy and elastase-induced mice and studied ∼8-11 wk after model induction. ADC and R were measured at a submillimeter planar resolution. Chord length (L(x)) data were analyzed from histology samples from the corresponding imaged slices. Logistic regression was applied to estimate the probability that an imaged pixel came from a diseased animal, and bootstrap methods (1,000 samples) were used to compare the regression results for the morphological and imaging results. Multivariate ANOVA (MANOVA) was used to analyze transformed ADC (ADC(BC)), and R (R(BC)) data and also to control for the experiment-wide error rate. MANOVA and ANOVA showed that elastase induced a statistically measureable change in the average transformed L(x) and ADC(BC) but not in the average R(BC). Marginal mean analysis demonstrated that ADC(BC) was on average 0.19 [95% confidence interval (CI): 0.16, 0.22] higher in the emphysema group, whereas R(BC) was on average 0.05 (95% CI: 0.04, 0.06) lower. Logistic regression supported the hypothesis that ADC(BC) and R(BC), together, were better at differentiating normal from diseased tissue than either measurement alone. The odds ratios for ADC(BC) and R(BC) were 7.73 (95% CI: 5.23, 11.42) and 9.14 × 10(-5) (95% CI: 3.33 × 10(-5), 25.06 × 10(-5)), respectively. Using a 50% probability cutoff, this model classified 70.6% of pixels correctly. The sensitivity and specificity of this model at the 50% cutoff were 74.9% and 65.2%, respectively. The area under the receiver operating characteristic curve was 0.76 (95% CI: 0.74, 0.78). The regression model presented can be used to map MRI data to disease probability maps. These probability maps present a future possibility of using both measurements in a more clinically feasible method of diagnosing this disease.


Assuntos
Modelos Animais de Doenças , Pulmão/patologia , Pulmão/fisiologia , Elastase Pancreática/toxicidade , Enfisema Pulmonar/patologia , Enfisema Pulmonar/fisiopatologia , Análise de Variância , Animais , Modelos Logísticos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Enfisema Pulmonar/induzido quimicamente , Distribuição Aleatória
2.
J Appl Physiol (1985) ; 110(1): 225-35, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20884833

RESUMO

Regional and global relationships of lung function and structure were studied using hyperpolarized ³He MRI in a rat elastase-induced model of emphysema (n = 4) and healthy controls (n = 5). Fractional ventilation (r) and apparent diffusion coefficient (ADC) of ³He were measured at a submillimeter planar resolution in ventral, middle, and dorsal slices 6 mo after model induction. Pulmonary function testing (PFT) was performed before MRI to yield forced expiratory volume in 50 ms (FEV50), airway resistance (R(I)), and dynamic compliance (C(dyn)). Cutoff threshold values of ventilation and diffusion, r* and ADC*, were computed corresponding to 80% population of pixels falling above or below each threshold value, respectively. For correlation analysis, r* was compared with FEV50/functional residual capacity (FRC), R(I) and C(dyn), whereas ADC* was compared with FEV50/FRC, total lung capacity (TLC), and C(dyn). Regional correlation of r and ADC was evaluated by dividing each of the three lung slices into four quadrants. C(dyn) was significantly larger in elastase rats (0.92 ± 0.16 vs. 0.61 ± 0.12 ml/cmH2O). The difference of R(I) and FEV50 was insignificant between the two groups. The r* of healthy rats was significantly larger than the elastase group (0.42 ± 0.03 vs. 0.28 ± 0.06), whereas ADC* was significantly smaller in healthy animals (0.27 ± 0.04 vs. 0.36 ± 0.01 cm²/s). No systematic difference in these quantities was observed between the three lung slices. A significant 33% increase in ADC* and a significant 31% decline in r* for elastase rats was observed compared with a significant 51% increase in C(dyn) and a nonsignificant 26% decline in FEV50/FRC. Correlation of imaging and PFT metrics revealed that r and ADC divide the rats into two separate clusters in the sample space.


Assuntos
Enfisema/patologia , Enfisema/fisiopatologia , Hélio , Pulmão/patologia , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Testes de Função Respiratória/métodos , Animais , Meios de Contraste , Enfisema/diagnóstico , Isótopos , Masculino , Compostos Radiofarmacêuticos , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Magn Reson Med ; 57(3): 459-63, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17326170

RESUMO

The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porcine model. Our results show that high spatial and temporal resolution images of pulmonary perfusion can be obtained with this contrast technique. Traditionally, pulmonary perfusion measurement techniques have been challenging because of insufficient signal for quantitative functional assessments. The use of polarized (13)C in MRI overcomes this limitation and may lead to a viable clinical method for studying the pulmonary vasculature and perfusion.


Assuntos
Pulmão/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Animais , Isótopos de Carbono , Meios de Contraste , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Modelos Animais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...