Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Nurs Res ; 31(4): 588-597, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34362264

RESUMO

To describe health related quality of life (HRQOL) and symptoms in the SPIRIT trial and determine effects of implantable cardioverter defibrillator (ICD) shocks on HRQOL over 24 months. Ninety participants aged 66 ± 10 years, 96% men, 75% with NYHA class II, with an ICD were randomized to spironolactone 25 mg (N = 44) or placebo (N = 46). HRQOL was measured every 6 months for 24 months using: Patient Concerns Assessment (PCA), Short Form Health Survey-Veterans Version (SF-36V), and Kansas City Cardiomyopathy Questionnaire (KCCQ). Linear mixed modeling compared changes in HRQOL over-time and ANCOVA compared HRQOL between those getting an ICD shock or not. Over 24-months, there were no differences in HRQOL between the spironolactone versus placebo groups. Those with at least one ICD shock reported significantly lower HRQOL and more symptoms at 6- and 24-months. Patients receiving one or more ICD shocks reported significant reductions in HRQOL and higher symptoms.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Feminino , Humanos , Masculino , Espironolactona/uso terapêutico
2.
Heart Rhythm O2 ; 2(4): 374-381, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34430943

RESUMO

BACKGROUND: Adaptive cardiac resynchronization therapy (aCRT) is known to have clinical benefits over conventional CRT, but the mechanisms are unclear. OBJECTIVE: Compare effects of aCRT and conventional CRT on electrical dyssynchrony. METHODS: A prospective, double-blind, 1:1 parallel-group assignment randomized controlled trial in patients receiving CRT for routine clinical indications. Participants underwent cardiac computed tomography and 128-electrode body surface mapping. The primary outcome was change in electrical dyssynchrony measured on the epicardial surface using noninvasive electrocardiographic imaging before and 6 months post-CRT. Ventricular electrical uncoupling (VEU) was calculated as the difference between the mean left ventricular (LV) and right ventricular (RV) activation times. An electrical dyssynchrony index (EDI) was computed as the standard deviation of local epicardial activation times. RESULTS: We randomized 27 participants (aged 64 ± 12 years; 34% female; 53% ischemic cardiomyopathy; LV ejection fraction 28% ± 8%; QRS duration 155 ± 21 ms; typical left bundle branch block [LBBB] in 13%) to conventional CRT (n = 15) vs aCRT (n = 12). In atypical LBBB (n = 11; 41%) with S waves in V5-V6, conduction block occurred in the anterior RV, as opposed to the interventricular groove in strict LBBB. As compared to baseline, VEU reduced post-CRT in the aCRT (median reduction 18.9 [interquartile range 4.3-29.2 ms; P = .034]), but not in the conventional CRT (21.4 [-30.0 to 49.9 ms; P = .525]) group. There were no differences in the degree of change in VEU and EDI indices between treatment groups. CONCLUSION: The effect of aCRT and conventional CRT on electrical dyssynchrony is largely similar, but only aCRT harmoniously reduced interventricular dyssynchrony by reducing RV uncoupling.

3.
Anesth Analg ; 129(6): 1529-1535, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31743172

RESUMO

BACKGROUND: Dexmedetomidine (Dex) is an attractive agent for procedural sedation due to its unique pharmacodynamic profile, specifically affording predictable sedation without concurrent respiratory depression. However, Dex has previously been reported to prevent or terminate arrhythmias. The purpose of this study was to investigate paroxysmal supraventricular tachycardia (PSVT) inducibility and homeostatic stability during electrophysiology studies (EPSs) and ablation when a standardized Dex protocol was used as the primary sedation agent. METHODS: We performed a retrospective review of 163 consecutive procedures for PSVT ablation that received Dex as the primary sedative with adjunct fentanyl and midazolam boluses (DEX-FENT-MIDAZ). This cohort was compared to 163 consecutive control procedures wherein strictly fentanyl and midazolam were used for sedation. The primary outcome reviewed was PSVT inducibility assessed before ablation. Reviewed secondary outcomes included level of sedation and intraprocedure hemodynamics and oxygenation. RESULTS: The arrhythmia profiles of the DEX-FENT-MIDAZ and control cohorts were very similar. The overall incidence of a "negative" EPSs in which arrhythmia was not induced was 24% in the DEX-FENT-MIDAZ group and 26% in the control group (P = .7). Unintended deep sedation was significantly less with DEX-FENT-MIDAZ (4.3% vs 27%; P ≤ .0001). However, DEX-FENT-MIDAZ use was associated with a higher incidence of intraprocedure hypotension. CONCLUSIONS: Dex sedation during EPSs is not associated with a reduction in PSVT inducibility. The therapeutic utility of Dex during EPS arises from the predictable sedation Dex affords but is associated with an increased incidence of intraprocedure hypotension.


Assuntos
Agonistas de Receptores Adrenérgicos alfa 2/uso terapêutico , Ablação por Cateter , Dexmedetomidina/uso terapêutico , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Hipnóticos e Sedativos/uso terapêutico , Taquicardia Supraventricular/cirurgia , Agonistas de Receptores Adrenérgicos alfa 2/efeitos adversos , Adulto , Idoso , Pressão Sanguínea/efeitos dos fármacos , Estimulação Cardíaca Artificial , Dexmedetomidina/efeitos adversos , Feminino , Humanos , Hipnóticos e Sedativos/efeitos adversos , Hipotensão/induzido quimicamente , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 30(9): 1636-1643, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31111594

RESUMO

INTRODUCTION: Dual external direct current cardioversion (dual-DCCV) is a rhythm control strategy for persistent atrial fibrillation (AF), involving simultaneous delivery of two shocks from two defibrillators. The long-term effectiveness of this approach has not been studied in the biphasic cardioversion era. METHODS: Seventy-seven consecutive patients at a single center were identified to receive dual-DCCV at the time of their initial cardioversion for AF, when maximum output standard external direct current cardioversion failed in two vectors. Logistic regression was used to analyze risk factors for dual-DCCV in a historical control group of 77 patients undergoing standard cardioversion and Cox proportional hazard models were used to compare time to AF recurrence. RESULTS: The dual-DCCV group had a significantly larger body mass index (BMI), but similar AF duration and left atrial size as controls. Multivariable logistic regression revealed that BMI and absence of prior paroxysmal AF were risk factors for dual-DCCV (P < 0.05). There was no difference observed between dual-DCCV and control groups (adjusted hazard ratio = 0.57; P = .12) after adjusting for number of shocks and age. Transient hypoxia was the only acute complication in either group (P > .999). CONCLUSION: Dual-DCCV appears to be a safe and effective cardioversion strategy for patients with AF. The need for dual-DCCV in the treatment of AF appears to be influenced more by body habitus than atrial substrate.


Assuntos
Fibrilação Atrial/terapia , Desfibriladores , Cardioversão Elétrica/instrumentação , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Bases de Dados Factuais , Cardioversão Elétrica/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Obesidade/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Circ Arrhythm Electrophysiol ; 5(4): 739-47, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-22773022

RESUMO

BACKGROUND: Previous studies have suggested that aldosterone blockade can reduce the incidence of ventricular tachycardia (VT) or ventricular fibrillation (VF) in patients with heart failure. The SPIronolactone to Reduce ICD Therapy (SPIRIT) trial was designed to test the hypothesis that spironolactone reduces the incidence of VT/VF in patients with implantable cardioverter-defibrillators (ICDs) who are at moderately high risk for recurrent VT/VF. METHODS AND RESULTS: Ninety patients who had ICDs who were at moderately high risk for recurrent VT/VF and who were not candidates for spironolactone by current heart failure guidelines were randomized to receive spironolactone 25 mg daily or placebo in a double-blind fashion. All patients had previously received ICD therapy (shock or antitachycardia pacing) for VT/VF within 2 years of randomization or an ICD for secondary prevention of VT/VF within 6 months of randomization. The primary end point was time to first recurrence of VT/VF requiring ICD therapy. After a median follow-up of 35 months, the Kaplan-Meier probability estimates for VT/VF requiring ICD therapy were 68.7% in the placebo group and 84.7% in the spironolactone group. Compared with placebo, spironolactone was associated with a similar risk of VT/VF (hazard ratio, 1.01; 95% CI, 0.64-1.83; P=0.71). There was no significant difference between the median times to first VT/VF recurrence requiring ICD therapy in the 2 groups. CONCLUSIONS: In patients with ICDs who were at moderately high risk for recurrent VT/VF on account of a recent VT/VF event that was either sustained or treated by the ICD and who were not candidates for spironolactone by current heart failure guidelines, spironolactone did not delay the first recurrence of VT/VF or reduce the risk of recurrent VT/VF.


Assuntos
Antiarrítmicos/uso terapêutico , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Espironolactona/uso terapêutico , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/prevenção & controle , Idoso , Antiarrítmicos/efeitos adversos , Terapia Combinada , Desfibriladores Implantáveis/efeitos adversos , Intervalo Livre de Doença , Método Duplo-Cego , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Antagonistas de Receptores de Mineralocorticoides/efeitos adversos , Análise Multivariada , Guias de Prática Clínica como Assunto , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Prevenção Secundária , Espironolactona/efeitos adversos , Taquicardia Ventricular/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , United States Department of Veterans Affairs , Fibrilação Ventricular/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA