Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Front Cardiovasc Med ; 11: 1285685, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476377

RESUMO

Coronary artery bypass grafting (CABG) is and continues to be the preferred revascularization strategy in patients with multivessel disease. Graft selection has been shown to influence the outcomes following CABG. During the last almost 60 years saphenous vein grafts (SVG) together with the internal mammary artery have become the standard of care for patients undergoing CABG surgery. While there is little doubt about the benefits, the patency rates are constantly under debate. Despite its acknowledged limitations in terms of long-term patency due to intimal hyperplasia, the saphenous vein is still the most often used graft. Although reendothelialization occurs early postoperatively, the process of intimal hyperplasia remains irreversible. This is due in part to the persistence of high shear forces, the chronic localized inflammatory response, and the partial dysfunctionality of the regenerated endothelium. "No-Touch" harvesting techniques, specific storage solutions, pressure controlled graft flushing and external stenting are important and established methods aiming to overcome the process of intimal hyperplasia at different time levels. Still despite the known evidence these methods are not standard everywhere. The use of arterial grafts is another strategy to address the inferior SVG patency rates and to perform CABG with total arterial revascularization. Composite grafting, pharmacological agents as well as latest minimal invasive techniques aim in the same direction. To give guide and set standards all graft related topics for CABG are presented in this expert opinion document on graft treatment.

2.
Mhealth ; 10: 8, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38323143

RESUMO

Background: This systematic review aims to highlight the untapped potential of heart rate variability (HRV) and atrial fibrillation (AF) monitoring by wearable health monitoring devices as a critical diagnostic tool in cardiac surgery (CS) patients. We reviewed established predictive capabilities of HRV and AF monitoring in specific cardiosurgical scenarios and provide a perspective on additional predictive properties of wearable health monitoring devices that need to be investigated. Methods: After screening most relevant databases, we included 33 publications in this review. Perusing these publications on HRV's prognostic value, we could identify HRV as a predictor for sudden cardiac death, mortality after acute myocardial infarction (AMI), and post operative atrial fibrillation (POAF). With regards to standard AF assessment, which typically includes extensive periods of unrecorded cardiac activity, we demonstrated that continuous monitoring via wearables recorded significant cardiac events that would otherwise have been missed. Results: Photoplethysmography and single-lead electrocardiogram (ECG) were identified as the most useful and convenient technical assessment modalities, and their advantages and disadvantages were described in detail. As a call to further action, we observed that the scientific community has relatively extensively explored wearable AF screening, whereas HRV assessment to improve relevant clinical outcomes in CS is rarely studied; it still has great potential to be leveraged. Conclusions: Therefore, risk assessment in CS would benefit greatly from earlier preoperative and postoperative AF detection, comprehensive and accurate assessment of cardiac health through HRV metrics, and continuous long-term monitoring. These should be achievable via commercially available wearables.

3.
Am Heart J ; 269: 158-166, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38163616

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Simulação por Computador , Qualidade de Vida , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X/efeitos adversos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos
4.
Clin Cardiol ; 47(2): e24197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069663

RESUMO

BACKGROUND: Postinterventional sonographic assessment of the femoral artery after transfemoral transcatheter aortic valve replacement (TF-TAVR) has the potential to identify several pathologies. We investigated the incidence and risk factors of femoral vessel complications in a modern TAVR collective using postinterventional sonography. METHODS: Between September 2017 and March 2022, 480 patients underwent TF-TAVR with postinterventional femoral sonography at a single center. Clinical outcomes and adverse events were analyzed after the Valve Academic Research Consortium 3 (VARC-3) criteria. RESULTS: In this cohort (51.2% male; age 80 ± 7.5 years, median EuroSCORE II 3.7) 74.8% (n = 359) were implanted with a self-expandable and 25.2% (n = 121) with a balloon-expandable valve. The main access (valve-delivery) was located right in 91.4% (n = 438), and the primary closure system was Proglide in 95% (n = 456). Vascular complications (VC) were observed in 29.16% (n = 140) of patients; 23.3% (n = 112) presented with minor- and 5.8% (n = 28) with major VC. Postinterventional femoral artery stenosis on the main access was observed in 9.8% (n = 47). Multivariable logistic regression analysis revealed female sex (p = .03, odds ratio [OR] 2.32, 95% confidence interval [CI] 1.09-4.89) and the number of used endovascular closure devices (p = .014, OR 0.11, 95%CI 0.02-0.64) as predictive factors for femoral artery stenosis. CONCLUSIONS: The incidence of postinterventional femoral artery stenosis following TF-TAVR was higher than expected with a number of used closure devices and female sex being independent risk factors. Considering the continuous advance of TAVR in low-risk patients with preserved physical activity, emphasis should be directed at the correct diagnosis and follow-up of these complications.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Resultado do Tratamento , Fatores de Risco , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estudos Retrospectivos
5.
Front Cardiovasc Med ; 10: 1166093, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37711559

RESUMO

Objective: Cardiac surgery is known to activate a cascade of inflammatory mediators leading to a systemic inflammatory response. Hemadsorption (HA) devices such as CytoSorb® have been postulated to mitigate an overshooting immune response, which is associated with increased morbidity and mortality, and thus improve outcome. We aimed to investigate the effect of CytoSorb® on interleukin (IL)-6 levels in patients undergoing complex cardiac surgery in comparison to a control group. Methods: A total of 56 patients (28 CytoSorb®, 28 control) undergoing acute and elective cardiac surgery between January 2020 and February 2021 at the Department of Cardiac and Vascular Surgery, Clinic Floridsdorf, Vienna, were retrospectively analyzed. The primary endpoint was the difference in IL-6 levels between the CytoSorb® and control group. Secondary endpoint was periprocedural mortality. Results: CytoSorb®, installed in the bypass circuit, had no significant effect on IL-6 levels. IL-6 peaked on the first postoperative day (HA: 775.3 ± 838.4 vs. control: 855.5 ± 1,052.9 pg/ml, p = 0.856). In total, three patients died in the HA group, none in the control (logistic regression model, p = 0.996). Patients with an increased Euroscore II of 7 or more showed a reduced IL-6 response compared to patients with an Euroscore II below 7 (178.3 ± 63.1 pg/ml vs. 908.6 ± 972.6 pg/ml, p-value = 0.00306). Conclusions: No significant reduction of IL-6 levels or periprocedural mortality through intraoperative HA with CytoSorb® in patients undergoing cardiac surgery was observed. However, this study was able to show a reduced immunologic response in patients with a high Euroscore II. The routine application of CytoSorb® in cardiac surgery to reduce inflammatory mediators has to be scrutinized in future prospective randomized studies.

6.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
7.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37255327

RESUMO

OBJECTIVES: Tricuspid regurgitation (TR) in patients who had heart transplants is associated with poor outcome. The increased risk for surgical and postoperative complications might be reduced in these vulnerable patients by transcatheter therapies. METHODS: All patients with a prior heart transplant (HTX) undergoing transcatheter edge-to-edge repair in the tricuspid position (T-TEER) were prospectively enrolled in an institutional registry. RESULTS: Seven patients who had heart transplants (5/7 female) at a mean age of 53 [48; 64] and median TRI-SCORE of 14 [7; 22] underwent T-TEER to treat symptomatic TR ≥ IV in an elective (n = 6) and urgent (n = 1) setting, respectively. The median time from HTX to T-TEER was 13 years. A total of 2 (n = 4) and 3 (n = 3) clips were implanted with a technical success in 6/7 (one single- device detachment). TR reduction was effective and durable within a median echocardiographic follow-up time of 10 months (TR baseline vs last follow-up: P = 0.03). Further, significant right ventricular remodelling (right ventricular end-diastolic diameter: 50 mm-36 mm, P = 0.02), decrease in the inferior vena cava diameter (24 mm-18 mm, P = 0.04) and in the gamma-glutamyl-transferase (255 U/l-159 U/l, P = 0.04) was found. Four of 7 patients were free of cardiovascular death (n = 1, 267 days after T-TEER), cardiac redo surgery (n = 1) and heart failure hospitalization (n = 2) and had no further clinical signs of right heart failure. CONCLUSIONS: T-TEER after HTX is feasible and effective regarding TR reduction in a short-term follow-up. The initial results may pave the way for a novel approach in TR management in patients having HTX.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Pessoa de Meia-Idade , Valva Tricúspide/cirurgia , Transplante de Coração/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Diástole , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
8.
JACC Case Rep ; 12: 101775, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37091059

RESUMO

Heterotopic caval valve implantation may be a reasonable option for alleviating symptoms in select high-risk patients with recurrent tricuspid regurgitation after failed interventional tricuspid valve repair. However, altered right atrial hemodynamic status should be considered in procedural planning to avoid potential right-left shunting in cases of septal defects. (Level of Difficulty: Advanced.).

10.
JACC Cardiovasc Interv ; 16(8): 927-941, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37100556

RESUMO

BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail. OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown. METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year. RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of ≥moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91). CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de Registros , Desenho de Prótese
11.
Front Cardiovasc Med ; 10: 1083300, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36742071

RESUMO

Introduction: Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound. Materials and methods: An MR-compatible, anatomically left ventricle, aortic root, and ascending aorta model was fabricated by combining 3D-printed parts and various soft silicone materials to match physiological characteristics. An Abbott Portico™ valve was used in continuous antegrade flow (12-22 l/min), retrograde flow with varying transvalvular pressures (60-110 mmHg), and physiological pulsatile hemodynamics (aortic pressure: 120/80 mmHg, cardiac output: 5 l/min) Time-resolved MR measurements were performed above and below the TAVI stent and compared with color Doppler ultrasound measurements in exactly the same setup. Results: The continuous antegrade flow measurements from MRI largely agreed with the flowmeter measurements, and a maximum error of only 7% was observed. In the retrograde configuration, visualization of the paravalvular leaks was possible from the MR measurements, but flow was overestimated by up to 33%. The 4D MRI measurement in the pulsatile setup revealed a single main PVL, which was also confirmed by the color Doppler measurements, and velocities were similar (2.0 m/s vs. 1.7 m/s). Discussion: 4D MRI techniques were used to qualitatively assess flow in a patient-specific, MR-compatible and flexible model, which only became possible through the use of 3D printing techniques. Flow patterns in the ascending aorta, identification and quantification of PVLs was possible and the location and extent of PVLs were confirmed by ultrasound measurements. The 4D MRI flow technique allowed evaluation of flow patterns in the ascending aorta and the left ventricle below the TAVI stent with good results in identifying PVLs, demonstrating its capabilities over ultrasound by providing the ability to visualize the paravalvular jets in three dimensions at however, additional expenditure of time and money.

12.
Circ Cardiovasc Interv ; 15(12): e012417, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36538579

RESUMO

BACKGROUND: The best management of stable coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear due to the marked inconsistency of the available evidence. METHODS: The REVASC-TAVI registry (Management of Myocardial Revascularization in Patients Undergoing Transcatheter Aortic Valve Implantation With Coronary Artery Disease) collected data from 30 centers worldwide on patients undergoing TAVI who had significant, stable CAD at preprocedural work-up. For the purposes of this analysis, patients with either complete or incomplete myocardial revascularization were compared in a propensity score matched analysis, to take into account of baseline confounders. The primary and co-primary outcomes were all-cause death and the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure, respectively, at 2 years. RESULTS: Among 2407 patients enrolled, 675 pairs of patients achieving complete or incomplete myocardial revascularization were matched. The primary (21.6% versus 18.2%, hazard ratio' 0.88 [95% CI, 0.66-1.18]; P=0.38) and co-primary composite (29.0% versus 27.1%, hazard ratio' 0.97 [95% CI, 0.76-1.24]; P=0.83) outcome did not differ between patients achieving complete or incomplete myocardial revascularization, respectively. These results were consistent across different prespecified subgroups of patients (< or >75 years of age, Society of Thoracic Surgeons score > or <4%, angina at baseline, diabetes, left ventricular ejection fraction > or <40%, New York Heart Association class I/II or III/IV, renal failure, proximal CAD, multivessel CAD, and left main/proximal anterior descending artery CAD; all P values for interaction >0.10). CONCLUSIONS: The present analysis of the REVASC-TAVI registry showed that, among TAVI patients with significant stable CAD found during the TAVI work-up, completeness of myocardial revascularization achieved either staged or concomitantly with TAVI was similar to a strategy of incomplete revascularization in reducing the risk of all cause death, as well as the risk of death, stroke, myocardial infarction, and rehospitalization for heart failure at 2 years, regardless of the clinical and anatomical situations.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Revascularização Miocárdica/efeitos adversos , Infarto do Miocárdio/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos
13.
Innovations (Phila) ; 17(6): 506-512, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36447382

RESUMO

OBJECTIVE: This study evaluated the ergonomics and time requirements of using a novel automated suturing and titanium fastener deployment technology for chordal replacement in human heart specimens in open and minimally invasive cardiac surgery (MICS) simulators. METHODS: Five cardiac surgeons used novel, manually powered expanded polytetrafluoroethylene (ePTFE) suturing devices to automate suture placement between mitral leaflets and papillary muscles in explanted cadaver hearts, along with customized titanium fastener delivery devices to secure suture and trim suture tails. This mitral chordal replacement test was conducted using surgical models simulating open and MICS mitral repair access. The study was approved by the institutional ethical board. RESULTS: After a brief introduction to this technique using plastic models, study surgeons performed 48 chordal replacements in human mitral valves, placing 18 in an open model and 30 in a right minithoracotomy model. The time range to complete a single chordal replacement was between 55 s and 8 min, with an overall mean duration of 3.6 ± 1.5 min. No difference in duration of implantation was recorded for the MICS and open sternotomy simulators used. Good control of suture delivery was reported in 95.8% (n = 46) of leaflet aspect of the sutures and in 100% (N = 48) of papillary muscle sutures. CONCLUSIONS: Automated mitral chordal ePTFE suturing simulated through open and MICS access demonstrated quality handling and accurate placement of sutures in human heart specimens. A clinical trial using this technology is currently ongoing. This innovation may present an important advance facilitating enhanced minimally invasive mitral valve repair.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Prolapso da Valva Mitral/cirurgia , Titânio , Cordas Tendinosas/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Suturas , Politetrafluoretileno , Técnicas de Sutura
14.
Artigo em Inglês | MEDLINE | ID: mdl-36331192

RESUMO

The recent CE mark approval of a novel transapical transcatheter beating-heart replacement system, anchored by an apical pad, expanded the therapeutic options for patients with a significantly diseased mitral valve who are not eligible for conventional surgery. However, this self-expandable bioprosthesis is-despite promising data from the first European real-world experience-not approved for patients with severe mitral annular calcification. In this video tutorial, we provide a step-by-step description of an off-label transapical mitral valve replacement in a patient with severe degenerative mitral valve disease and limited alternative treatment options.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Uso Off-Label , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Calcinose/cirurgia , Cateterismo Cardíaco , Insuficiência da Valva Mitral/cirurgia
16.
Front Cardiovasc Med ; 9: 953622, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36247427

RESUMO

Background: Improved understanding of the mechanisms that sustain persistent and long-standing persistent atrial fibrillation (LSpAF) is essential for providing better ablation solutions. The findings of traditional catheter-based electrophysiological studies can be impacted by the sedation required for these procedures. This is not required in non-invasive body-surface mapping (ECGI). ECGI allows for multiple mappings in the same patient at different times. This would expose potential electrophysiological changes over time, such as the location and stability of extra-pulmonary vein drivers and activation patterns in sustained AF. Materials and methods: In this electrophysiological study, 10 open-heart surgery candidates with LSpAF, without previous ablation procedures (6 male, median age 73 years), were mapped on two occasions with a median interval of 11 days (IQR: 8-19) between mappings. Bi-atrial epicardial activation sequences were acquired using ECGI (CardioInsight™, Minneapolis, MN, United States). Results: Bi-atrial electrophysiological abnormalities were documented in all 20 mappings. Interestingly, the anatomic location of focal and rotor activities changed between the mappings in all patients [100% showed changes, 95%CI (69.2-100%), p < 0.001]. Neither AF driver type nor their number varied significantly between the mappings in any patient (median total number of focal activities 8 (IQR: 1-16) versus 6 (IQR: 2-12), p = 0.68; median total number of rotor activities 48 (IQR: 44-67) versus 55 (IQR: 44-61), p = 0.30). However, individual zones showed a high number of quantitative changes (increase/decrease) of driver activity. Most changes of focal activity were found in the left atrial appendage, the region of the left lower pulmonary vein and the right atrial appendage. Most changes in rotor activity were found also at the left lower pulmonary vein region, the upper half of the right atrium and the right atrial appendage. Conclusion: This clinical study documented that driver location and activation patterns in patients with LSpAF changes constantly. Furthermore, bi-atrial pathophysiology was demonstrated, which underscores the importance of treating both atria in LSpAF and the significant role that arrhythmogenic drivers outside the pulmonary veins seem to have in maintaining this complex arrhythmia.

17.
Front Cardiovasc Med ; 9: 922357, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966546

RESUMO

Background: During on-pump coronary artery bypass grafting (ONCAB), graft flushing for distal anastomoses testing also perfuses the downstream myocardium. This single-center retrospective study evaluated the impact of specific preservation solutions on myocardial protection during ONCAB. Materials and methods: Between July 2019 and March 2020 either DuraGraft (DG) or 0.9% Saline/Biseko (SB) was applied to 272 ONCAB. Overall, 166 patients were propensity-matched into two groups. Cardiac enzymes [high-sensitive Troponin I (hs-TnI) and creatine kinase (CK)] were evaluated 7 days post-surgery. Results: Post-surgery, hs-TnI values were significantly lower from 3 to 6 h (h) up to 4 days in the DG group: 3-6 h: 4,034 ng/L [IQR 1,853-8,654] vs. 5,532 ng/L [IQR 3,633-8,862], p = 0.05; 12-24 h: 2,420 ng/L [IQR 1,408-5,782] vs. 4,166 [IQR 2,052-8,624], p < 0.01; 2 days: 1,095 ng/L [IQR 479-2,311] vs. 1,564 ng/L [IQR 659-5,057], p = 0.02 and at 4 days: 488 ng/L [IQR 232-1,061] vs. 745 ng/L [IQR 319-1,820], p = 0.03. The maximum value: 4,151 ng/L [IQR 2,056-8,621] vs. 6,349 ng/L [IQR 4,061-12,664], p < 0.01 and the median area under the curve (AUC): 6,146 ng/L/24 h [IQR 3,121-13,248] vs. 10,735 ng/L/24 h [IQR 4,859-21,484], p = 0.02 were lower in the DG group. CK values were not significantly different between groups: maximum value 690 [IQR 417-947] vs. 631 [464-979], p = 0.61 and AUC 1,986 [1,226-2,899] vs. 2,081 [1,311-3,063], p = 0.37. Conclusion: Repeated graft flushing with DG resulted in lower Troponin values post-surgery suggesting enhanced myocardial protection compared to SB. Additional studies are warranted to further assess the myocardial protection properties of DG.

18.
Front Cardiovasc Med ; 9: 891468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35722132

RESUMO

Introduction: Severe tricuspid regurgitation (TR) is a common condition promoting right heart failure and is associated with a poor long-term prognosis. Transcatheter tricuspid valve repair (TTVR) emerged as a low-risk alternative to surgical repair techniques. However, patient selection remains controversial, particularly regarding the benefits of TTVR in patients with pulmonary hypertension (PH). Aim: We aimed to investigate the impact of preprocedural invasive hemodynamic assessment and procedural success on right ventricular (RV) remodeling and outcome. Methods: All patients undergoing TTVR with a TR reduction of ≥1 grade without precapillary or combined PH [mean pulmonary artery pressure (mPAP) ≥25 mmHg, mean pulmonary artery Wedge pressure ≤ 15 mmHg, pulmonary vascular resistance ≥3 Wood units] were assigned to the responder group. All patients with a TR reduction of ≥1 grade and precapillary or combined PH were classified as non-responders. Patients with a TR reduction ≥2 grade were directly classified as responders, and patients without TR reduction were directly assigned as non-responders. Results: A total of 107 patients were enrolled, 75 were classified as responders and 32 as non-responders. We observed evidence of significant RV reverse remodeling in responders with a decrease in RV diameters (-2.9 mm, p = 0.001) at a mean follow-up of 229 days (±219 SD) after TTVR. RV function improved in responders [fractional area change (FAC) + 5.7%, p < 0.001, RV free wall strain +3.9%, p = 0.006], but interestingly further deteriorated in non-responders (FAC -4.5%, p = 0.003, RV free wall strain -3.9%, p = 0.007). Non-responders had more persistent symptoms than responders (NYHA ≥3, 72% vs. 11% at follow-up). Subsequently, non-response was associated with a poor long-term prognosis in terms of death, heart failure (HF) hospitalization, and re-intervention after 2 years (freedom of death, HF hospitalization, and reintervention at 2 years: 16% vs. 78%, log-rank: p < 0.001). Conclusion: Hemodynamic assessment before TTVR and procedural success are significant factors for patient prognosis. The hemodynamic profiling prior to intervention is an essential component in patient selection for TTVR. The window for edge-to-edge TTVR might be limited, but timely intervention is an important factor for a better outcome and successful right ventricular reverse remodeling.

19.
Front Cardiovasc Med ; 9: 849972, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402525

RESUMO

Background: Congestion and plasma volume expansion are important features of heart failure, whose prognostic significance has been investigated in a range of surgical and non-surgical settings. The aim of this study was to evaluate the value of the estimated plasma volume status (ePVS) in patients undergoing isolated tricuspid valve surgery. Methods: This study included patients who underwent isolated tricuspid valve surgery at the Vienna General Hospital (Austria) between July 2008 and November 2018. The PVS cut-off was calculated using ROC analysis and Youden's Index. Results: Eighty eight patients (median age: 58 [IQR: 35-70] years; 44.3% male; 75.6% NYHA III/IV; median EuroSCORE II 2.65 [IQR: 1.70-5.10]; 33.0% endocarditis-related regurgitation; 60.2% isolated repair; 39.8% isolated replacement) were included in this study. Patients who died within 1 year following surgery had significantly higher baseline ePVS values than survivors (median ePVS 5.29 [IQR: -1.55-13.55] vs. -3.68 [IQR: -10.92-4.22]; p = 0.005). During a median actuarial follow-up of 3.02 (IQR: 0.36-6.80) years, patients with a preoperative ePVS ≥ -4.17 had a significantly increased mortality (log-rank p = 0.006). Conclusions: ePVS is an easily obtainable risk parameter for patients undergoing isolated tricuspid valve surgery capable of predicting mid- and long-term outcomes after isolated tricuspid valve surgery.

20.
Med Klin Intensivmed Notfmed ; 117(3): 187-190, 2022 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-35304641

RESUMO

Transcatheter therapy of the mitral valve is more challenging compared to the aortic valve. Interventional therapy with the Mitra-Clip system, mimicking the surgical edge-to-edge repair, was first introduced in 2003 and received the CE mark in 2008. The first implantation of the Tendyne system, which is currently the only commercially available system for mitral valve replacement, was performed in 2014, and routine clinical use was approved in 2020. Several new valve platforms are in clinical development and will expand the treatment portfolio. This article will discuss the clinical indications, technical challenges and specific requirements for perioperative management.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Assistência Perioperatória , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...