1.
Rev Sci Instrum ; 87(2): 02A703, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931921

RESUMO

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of ECRISs.

2.
Rev Sci Instrum ; 87(2): 02A725, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931943

RESUMO

Several ion source related research and development projects are in progress at the Department of Physics, University of Jyväskylä (JYFL). The work can be divided into investigation of the ion source plasma and development of ion sources, ion beams, and diagnostics. The investigation covers the Electron Cyclotron Resonance Ion Source (ECRIS) plasma instabilities, vacuum ultraviolet (VUV) and visible light emission, photon induced electron emission, and the development of plasma diagnostics. The ion source development covers the work performed for radiofrequency-driven negative ion source, RADIS, beam line upgrade of the JYFL 14 GHz ECRIS, and the development of a new room-temperature-magnet 18 GHz ECRIS, HIISI.

3.
Rev Sci Instrum ; 85(2): 02A739, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593473

RESUMO

In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

4.
Rev Sci Instrum ; 83(2): 02B705, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380310

RESUMO

The driver linac for the facility for rare isotope beams (FRIB) will provide a wide range of primary ion beams for nuclear physics research. The linac will be capable of accelerating a uranium beam to an energy of up to 200 Mev∕u and delivering it to a fragmentation target with a maximum power of 400 kW. Stable ion beams will be produced by a high performance electron cyclotron resonance ion source operating at 28 GHz. The ion source will be located on a high voltage platform to reach an initial beam energy of 12 keV∕u. After extraction, the ion beam will be transported vertically down to the linac tunnel in a low energy beam transport (LEBT) system and injected into a radio frequency quadrupole (RFQ) operating at a frequency of 80.5 MHz. To meet the beam power requirements, simultaneous acceleration of two-charge states will be used for heavier ions (≥Xe). This paper presents the layout of the FRIB LEBT and the beam dynamics in the LEBT. In particular, simulation and design of the beam line section before charge state selection will be detailed. The need to use an achromatic design for the charge state selection system and the advantage of an ion beam collimation system to limit the emittance of the beam injected into the RFQ will be discussed in this paper.

5.
Rev Sci Instrum ; 79(2 Pt 2): 02A302, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315092

RESUMO

A new electron cyclotron resonance ion source (ECRIS) was constructed at the NSCL/MSU to replace the existing SC-ECRIS. This ECRIS operates at 18+14.5 GHz microwave frequencies with a planned upgrade to 24-28 GHz in the second phase of commissioning. A superconducting hexapole coil system produce the radial magnetic field; the axial trapping is produced with six superconducting solenoid coils enclosed in an iron yoke to allow the optimization of the distance between the plasma electrode and the resonant zone in the plasma. We report the details of the design, construction, and initial commissioning results of this new ECRIS.

6.
Rev Sci Instrum ; 79(2 Pt 2): 02A303, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315093

RESUMO

The increased requirements towards the use of higher ion beam intensities motivated us to initiate the project to improve the overall transmission of the K130 cyclotron facility. With the facility the transport efficiency decreases rapidly as a function of total beam intensity extracted from the JYFL ECR ion sources. According to statistics, the total transmission efficiency is of the order of 10% for low beam intensities (I(total)< or =0.7 mA) and only about 2% for high beam intensities (I(total)>1.5 mA). Requirements towards the use of new metal ion beams for the nuclear physics experiments have also increased. The miniature oven used for the production of metal ion beams at the JYFL is not able to reach the temperature needed for the requested metal ion beams. In order to fulfill these requirements intensive development work has been performed. An inductively and a resistively heated oven has successfully been developed and both are capable of reaching temperatures of about 2000 degrees C. In addition, sputtering technique has been tested. GEANT4 simulations have been started in order to better understand the processes involved with the bremsstrahlung, which gives an extra heat load to cryostat in the case of superconducting ECR ion source. Parallel with this work, a new advanced ECR heating simulation program has been developed. In this article we present the latest results of the above-mentioned projects.

7.
Rev Sci Instrum ; 79(2 Pt 2): 02B714, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315205

RESUMO

Solenoids are widely used to provide initial focusing of beams extracted from an ion source. However, in the case of an electron cyclotron resonance (ECR) ion source, the extracted beam will usually include different ion species and for each of them a wide distribution of charge states. When such a multicomponent beam is focused by a solenoid, the ions with a Q/A larger than the beam of interest are overfocused and usually go through a waist before reaching the analyzing magnet. If the beam currents obtained for these ions are sufficient, the resulting space charge forces can significantly degrade the emittance of the beam components with a lower Q/A and result for those in a hollow beam. Using a beam viewer and an emittance-measuring device, this paper reports on experimental findings that confirm the existence of such an effect for low charge states of argon. Moreover, by changing the experimental conditions of the ECR plasma in order to modify the charge state distribution of the extracted ion beam, it is shown that the threshold where this space charge effect starts to be significant can be changed.