Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
3.
Int J Lab Hematol ; 44(5): 817-822, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35451557

RESUMO

BACKGROUND: Severe coronavirus disease 2019 (COVID-19) is characterized by marked hypoxaemia and lung oedema, often accompanied by disordered blood coagulation and fibrinolytic systems, endothelial damage and intravascular fibrin deposition. PATIENTS/METHODS: We present a retrospective observational study of 104 patients admitted to hospital with COVID-19. Plasma samples were collected within 72 h of admission. In addition to routine coagulation and haematology testing, soluble thrombomodulin (sTM), thrombin-antithrombin (TAT), tissue plasminogen activator-plasminogen activator inhibitor 1 complex (tPAI-C) and plasmin-α2 antiplasmin complex (PIC) were performed by automated chemiluminescent enzyme immunoassays. RESULTS: Significantly higher levels of D-dimer, TAT, sTM and tPAI-C were observed in non-survivors compared to survivors. To confirm which parameters were independent risk factors for mortality, multiple logistic regression was performed on D-dimer, TAT. sTM, tPAI-C and PIC data. Only increasing sTM was significantly associated with mortality, with an odds ratio of 1.065 for each 1.0 TU/mL increment (95% CI 1.025-1.115). CONCLUSIONS: Of the haemostatic variables measured, sTM, which can be rapidly assayed, is the best independent predictor of mortality in patients hospitalized with COVID-19, and this suggests that endothelial dysfunction plays an important role in disease progression.


Assuntos
Transtornos da Coagulação Sanguínea , COVID-19 , Biomarcadores , Coagulação Sanguínea , Fibrinólise , Humanos , Ativador de Plasminogênio Tecidual
4.
Int J Lab Hematol ; 43(6): 1593-1598, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34252265

RESUMO

BACKGROUND: The Sysmex CN-6500 is a new haemostasis analyser with an integrated immunoassay module that performs chemiluminescence enzyme assay (CLEIA) in addition to coagulation, turbidimetric, chromogenic and platelet aggregation tests. AIMS: To evaluate the analytical performance of the CN-6500 against the predicate device (Sysmex HISCL-800) for soluble thrombomodulin (TM), thrombin-antithrombin (TAT), tissue plasminogen activator/plasminogen activator inhibitor 1 complex (tPAI-C) and plasmin α2 plasmin inhibitor complex (PIC) assays. METHODS: Imprecision was assessed by testing two levels of quality control plasmas 10 times on 5 separate days. Comparability was studied in 230 plasmas from normal donors (n = 30), patients with suspected disseminated intravascular coagulation (DIC, n = 100), sepsis (n = 20) or liver disease (n = 20), lipaemic (n = 20), haemolysed (n = 20) and icteric samples (n = 20). Limit of detection, limit of quantitation and linearity were determined by testing serial dilutions of normal plasma. Sample carryover was assessed by testing samples with high and low normal levels of the analytes concerned. RESULTS: The CN-6500 performed 21 CLEIA tests per hour, while simultaneously performing coagulation tests. Acceptable between-run imprecision was obtained using commercial controls with normal and high activity for each analyte (%CV <4%), for all four assays. Excellent linearity was observed (slope 0.89-1.03; r2 >0.99) across the measurement range. The lower limits of detection and quantitation were as follows: TM <0.3/0.6 TU/ml, TAT >0.1/<0.2 ng/ml, PIC <0.004/<0.008 µg/ml and tPAI-C < 0.01/<0.1 ng/ml, respectively. All four assays showed excellent correlation between analysers and were unaffected by haemolysis, icterus or lipaemia. No carryover was observed. CONCLUSIONS: Our data demonstrate that the performance of the CLEIA assays on the CN-6500 is comparable to that of a stand-alone immunoassay analyser.


Assuntos
Testes de Coagulação Sanguínea/normas , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Medições Luminescentes/métodos , Medições Luminescentes/normas , Automação Laboratorial , Coagulação Sanguínea , Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/métodos , Humanos , Técnicas Imunoenzimáticas/instrumentação , Medições Luminescentes/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Int J Lab Hematol ; 43 Suppl 1: 3-4, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34288446
6.
J Clin Med ; 11(1)2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-35011808

RESUMO

BACKGROUND: Acquired activated protein C resistance (APCr) has been identified in antiphospholipid syndrome (APS) and systemic lupus erythematosus (SLE). OBJECTIVE: To assess agreement between the ST-Genesia® and CAT analysers in identifying APCr prevalence in APS/SLE patients, using three thrombin generation (TG) methods. METHODS: APCr was assessed with the ST-Genesia using STG-ThromboScreen and with the CAT using recombinant human activated protein C and Protac® in 105 APS, 53 SLE patients and 36 thrombotic controls. Agreement was expressed in % and by Cohen's kappa coefficient. RESULTS: APCr values were consistently lower with the ST-Genesia® compared to the CAT, using either method, in both APS and SLE patients. Agreement between the two analysers in identifying APS and SLE patients with APCr was poor (≤65.9%, ≤0.20) or fair (≤68.5%, ≥0.29), regardless of TG method, respectively; no agreement was observed in thrombotic controls. APCr with both the ST Genesia and the CAT using Protac®, but not the CAT using rhAPC, was significantly greater in triple antiphospholipid antibody (aPL) APS patients compared to double/single aPL patients (p < 0.04) and in thrombotic SLE patients compared to non-thrombotic SLE patients (p < 0.05). Notably, the ST-Genesia®, unlike the CAT, with either method, identified significantly greater APCr in pregnancy morbidity (median, confidence intervals; 36.9%, 21.9-49.0%) compared to thrombotic (45.7%, 39.6-55.5%) APS patients (p = 0.03). CONCLUSION: Despite the broadly similar methodology used by CAT and ST-Genesia®, agreement in APCr was poor/fair, with results not being interchangeable. This may reflect differences in the TG method, use of different reagents, and analyser data handling.

7.
Molecules ; 26(1)2020 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-33375091

RESUMO

Coffee is rich in caffeine (CF), chlorogenic acid (CGA) and phenolics. Differing types of coffee beverages and brewing procedures may result in differences in total phenolic contents (TPC) and biological activities. Inflammation and increases of platelet activation and aggregation can lead to thrombosis. We focused on determining the chemical composition, antioxidant activity and inhibitory effects on agonist-induced platelet aggregation and cyclooxygenase (COX) of coffee beverages in relation to their preparation method. We prepared instant coffee and brewed coffee beverages using drip, espresso, and boiling techniques. Coffee extracts were assayed for their CF and CGA contents using HPLC, TPC using colorimetry, platelet aggregation with an aggregometer, and COX activity using ELISA. The findings have shown all coffee extracts, except the decaffeinated types, contained nearly equal amounts of CF, CGA, and TPC. Inhibitory effects of coffee extracts on platelet aggregation differed depending on the activation pathways induced by different agonists. All espresso, drip and boiled coffee extracts caused dose dependent inhibition of platelet aggregation induced by ADP, collagen, epinephrine, and arachidonic acid (ARA). The most marked inhibition was seen at low doses of collagen or ARA. Espresso and drip extracts inhibited collagen-induced platelet aggregation more than purified caffeine or CGA. Espresso, boiled and drip coffee extracts were also a more potent inhibitors of COX-1 and COX-2 than purified caffeine or CGA. We conclude that inhibition of platelet aggregation and COX-1 and COX-2 may contribute to anti-platelet and anti-inflammatory effects of espresso and drip coffee extracts.


Assuntos
Coffea/química , Café/química , Inibidores de Ciclo-Oxigenase/química , Inibidores de Ciclo-Oxigenase/farmacologia , Inibidores da Agregação Plaquetária/química , Inibidores da Agregação Plaquetária/farmacologia , Ácido Clorogênico/química , Ácido Clorogênico/farmacologia , Cromatografia Líquida de Alta Pressão , Estrutura Molecular , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Agregação Plaquetária/efeitos dos fármacos
8.
Int J Lab Hematol ; 42(5): 643-649, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32885901

RESUMO

BACKGROUND: The CN-6000 (Sysmex Corp.) is a new haemostasis analyser with blood coagulation, amidolytic, immuno-turbidometric and light transmission aggregometry (LTA) capabilities. Transmitted light is monitored at multiple wavelengths (340, 405, 575, 660, 800 nm), from an LED light source. AIMS: To evaluate the performance of the CN-6000 against a predicate device. METHODS: The CN-6000 was evaluated against the CS-5100 (Sysmex) for 14 different tests, using 880 samples from normal subjects, anticoagulated patients, critically ill patients, plasmas with high or low fibrinogen content or abnormal levels of interfering substances. Between-day assay imprecision was assessed using commercial QC materials (n = 10 replicates on each of 5 days). RESULTS: Acceptable levels of imprecision were obtained for all assays. Agreement between the two analysers was excellent for all assays. Throughput was 35% higher using the CN-6000 (337 vs 250 tests per hour for PT, aPTT and fibrinogen). The CN-6000 also demonstrated improved clot detection in plasmas with high levels of interfering substances as demonstrated by a 29% reduction in "vote-outs" due to low light transmission (24 vs 34). CONCLUSIONS: The CN-6000 demonstrated excellent comparability with the predicate instrument and acceptable levels of imprecision in all assays. Improvements in throughput and clot detection in the presence of interfering substances were also shown.


Assuntos
Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/métodos , Coagulação Sanguínea , Testes de Coagulação Sanguínea/normas , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Int J Lab Hematol ; 42(2): 140-144, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31769186

RESUMO

INTRODUCTION: Plasma samples with gross lipaemia present a challenge for coagulation laboratories using optical analysers. High-speed centrifugation may be used to remove excess lipids but it has not established whether this affects haemostasis tests. The aims were to determine whether the removal of lipid by centrifugation affects PT, APTT, fibrinogen, D-dimer and von Willebrand factor activity measurements. METHODS: Twenty-six lipaemic samples (median [range]): triglyceride 4.6 mmol/L [0.5-17.0]; cholesterol: 4.06 mmol/L [2.20-9.41] and 20 plasmas spiked with Intralipid 20 or lipid isolated from patient plasmas (median triglyceride of 11.95 mmol/L [5.0-17.0] and cholesterol 4.33 [3.22-7.06]), were tested before and after the removal of the lipid layer by centrifugation (10000 g for 10 minutes). Tests were performed using the CS-5100 (Sysmex) coagulation analyser. RESULTS: Thirteen, 9, 3 and 1 of the lipaemic or spiked samples failed to give PT, APTT, fibrinogen and D-dimer results, respectively. Centrifugation significantly reduced triglyceride (median 2.7, [0-6.1 mmol/L]) and cholesterol (median 0.52 [0-3.5]), allowing clot detection in all tests. There were no statistically significant differences in fibrinogen, D-dimer or VWF levels in samples before and after lipid removal. A small but clinically insignificant change in PT and APTT was observed after lipid removal. CONCLUSION: High-speed centrifugation reduces lipaemia sufficiently to allow testing on an optical coagulation analyser without introducing clinically significant differences PT, APTT, fibrinogen, D-dimer or VWF activity values.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Hiperlipidemias/sangue , Lipídeos/sangue , Plasma/metabolismo , Testes de Coagulação Sanguínea , Humanos
10.
J Thromb Haemost ; 17(12): 2069-2080, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31364274

RESUMO

BACKGROUND: Variability remains a challenge in lupus anticoagulant (LA) testing. OBJECTIVE: To validate LA test performance between Antiphospholipid Syndrome Alliance for Clinical Trials and International Networking (APS ACTION) Core laboratories and examine agreement in LA status between Core and local/hospital laboratories contributing patients to this prospective registry. METHODS: Five Core laboratories used the same reagents, analyzer type, protocols, and characterized samples for LA validation. Non-anticoagulated registry samples were retested at the corresponding regional Core laboratories and anticoagulated samples at a single Core laboratory. Categorical agreement and discrepancies in LA status between Core and local/hospital laboratories were analyzed. RESULTS: Clotting times for the reference/characterized plasmas used for normalized ratios were similar between Core laboratories (CV <4%); precision and agreement for LA positive/negative plasma were similar (all CV ≤5%) in the four laboratories that completed both parts of the validation exercise; 418 registry samples underwent LA testing. Agreement for LA positive/negative status between Core and local/hospital laboratories was observed in 87% (115/132) non-anticoagulated and 77% (183/237) anticoagulated samples. However, 28.7% (120/418) of samples showed discordance between the Core and local/hospital laboratories or equivocal LA results. Some of the results of the local/hospital laboratories might have been unreliable in 24.7% (41/166) and 23% (58/252) of the total non-anticoagulated and anticoagulated samples, respectively. Equivocal results by the Core laboratory might have also contributed to discordance. CONCLUSIONS: Laboratories can achieve good agreement in LA performance by use of the same reagents, analyzer type, and protocols. The standardized Core laboratory results underpin accurate interpretation of APS ACTION clinical data.


Assuntos
Síndrome Antifosfolipídica/diagnóstico , Ensaio de Proficiência Laboratorial , Inibidor de Coagulação do Lúpus/sangue , Testes Sorológicos/normas , Anticoagulantes/sangue , Síndrome Antifosfolipídica/sangue , Biomarcadores/sangue , Ensaios Clínicos como Assunto , Bases de Dados Factuais , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Tempo de Protrombina/normas , Sistema de Registros , Reprodutibilidade dos Testes
11.
J Thromb Haemost ; 17(10): 1715-1732, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31271706

RESUMO

BACKGROUND: Current guidelines have contributed to more uniformity in the performance and interpretation of lupus anticoagulant (LA) testing. However, points to reconsider include testing for LA in patients on anticoagulation, cut-off values, and interpretation of results. OBJECTIVES: The aim of this International Society of Thrombosis and Haemostasis Scientific and Standardization committee (ISTH SSC) questionnaire was to capture the spectrum of clinical and laboratory practice in LA detection, focusing on variability in practice, so that the responses could inform further ISTH SSC recommendations. METHODS: Members of the ISTH SSC on Lupus Anticoagulant/Antiphospholipid Antibodies and participants of the Lupus Anticoagulant/Antiphospholipid Antibodies Programme of the External quality Control of diagnostic Assays and Tests Foundation were invited to complete a questionnaire on LA testing that was placed on the ISTH website using RedCap, with data tallied using simple descriptive statistics. RESULTS: There was good agreement on several key recommendations in the ISTH and other guidelines on LA testing, such as sample processing, principles of testing, choice of tests, repeat testing to confirm persistent positivity and the use of interpretative reporting. However, the results highlight that there is less agreement on some other aspects, including the timing of testing in relation to thrombosis or pregnancy, testing in patients on anticoagulation, cut-off values, and calculation and interpretation of results. CONCLUSIONS: Although some of the variability in practice in LA testing reflects the lack of substantive data to underpin evidence-based recommendations, a more uniform approach, based on further guidance, should reduce the inter-center variability of LA testing.


Assuntos
Análise Química do Sangue/normas , Serviços de Laboratório Clínico/normas , Disparidades em Assistência à Saúde/normas , Inibidor de Coagulação do Lúpus/sangue , Biomarcadores/sangue , Pesquisas sobre Atenção à Saúde , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
12.
Curr Rheumatol Rep ; 19(8): 50, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28730526

RESUMO

We respond to comments by Dufrost et al. about the RAPS trial, in particular, showing that the trial did achieve its target sample size; pointing out that thrombin potential is not synonymous with overall thrombin generation; confirming that overall, no increased thrombotic risk was evident comparing rivaroxaban with warfarin; and that high-risk patients (28% were triple positive, representative of patients with venous thromboembolism requiring standard-intensity anticoagulation) were included; and clarifying our rationale for using a laboratory surrogate primary outcome measure instead of a clinical one.


Assuntos
Síndrome Antifosfolipídica , Tromboembolia Venosa , Anticoagulantes , Humanos , Rivaroxabana , Varfarina
13.
Lancet Haematol ; 3(9): e426-36, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27570089

RESUMO

BACKGROUND: Rivaroxaban is established for the treatment and secondary prevention of venous thromboembolism, but whether it is useful in patients with antiphospholipid syndrome is uncertain. METHODS: This randomised, controlled, open-label, phase 2/3, non-inferiority trial, done in two UK hospitals, included patients with antiphospholipid syndrome who were taking warfarin for previous venous thromboembolism, with a target international normalised ratio of 2·5. Patients were randomly assigned 1:1 to continue with warfarin or receive 20 mg oral rivaroxaban daily. Randomisation was done centrally, stratified by centre and patient type (with vs without systemic lupus erythematosus). The primary outcome was percentage change in endogenous thrombin potential (ETP) from randomisation to day 42, with non-inferiority set at less than 20% difference from warfarin in mean percentage change. Analysis was by modified intention to treat. Other thrombin generation parameters, thrombosis, and bleeding were also assessed. Treatment effect was measured as the ratio of rivaroxaban to warfarin for thrombin generation. This trial is registered with the ISRCTN registry, number ISRCTN68222801. FINDINGS: Of 116 patients randomised between June 5, 2013, and Nov 11, 2014, 54 who received rivaroxaban and 56 who received warfarin were assessed. At day 42, ETP was higher in the rivaroxaban than in the warfarin group (geometric mean 1086 nmol/L per min, 95% CI 957-1233 vs 548, 484-621, treatment effect 2·0, 95% CI 1·7-2·4, p<0·0001). Peak thrombin generation was lower in the rivaroxaban group (56 nmol/L, 95% CI 47-66 vs 86 nmol/L, 72-102, treatment effect 0·6, 95% CI 0·5-0·8, p=0·0006). No thrombosis or major bleeding were seen. Serious adverse events occurred in four patients in each group. INTERPRETATION: ETP for rivaroxaban did not reach the non-inferiority threshold, but as there was no increase in thrombotic risk compared with standard-intensity warfarin, this drug could be an effective and safe alternative in patients with antiphospholipid syndrome and previous venous thromboembolism. FUNDING: Arthritis Research UK, Comprehensive Clinical Trials Unit at UCL, LUPUS UK, Bayer, National Institute for Health Research Biomedical Research Centre.


Assuntos
Síndrome Antifosfolipídica/tratamento farmacológico , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Rivaroxabana/uso terapêutico , Trombose/tratamento farmacológico , Varfarina/uso terapêutico , Anticoagulantes/uso terapêutico , Síndrome Antifosfolipídica/complicações , Síndrome Antifosfolipídica/epidemiologia , Estudos de Equivalência como Asunto , Inibidores do Fator Xa/uso terapêutico , Feminino , Seguimentos , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Taxa de Sobrevida , Trombose/complicações , Trombose/epidemiologia , Resultado do Tratamento , Reino Unido/epidemiologia
14.
Blood Coagul Fibrinolysis ; 27(7): 786-790, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27214035

RESUMO

Factor XIII (FXIII) has an important role in the control of bleeding through fibrin cross-linking; however, its effect within the menstrual cycle is not fully understood. The aim of this study was to examine changes in FXIII activity during the normal menstrual cycle and correlate FXIII activity with menstrual blood loss. A total of 32 healthy normal women of reproductive age were recruited. Menstrual blood loss was measured using the pictorial blood-assessment chart (PBAC). A bleeding score questionnaire was also completed. Blood samples were taken during the menstrual, proliferative, periovulatory, secretory and premenstrual phase for assessment of FXIII level. The mean ±â€ŠSD FXIII level was lowest during menstrual and periovulatory phases (114 ±â€Š23 and 114 ±â€Š21 IU/dl, respectively). Mean FXIII level during the secretory and premenstrual phases were higher than the menstrual phase (P = 0.036). Mean secretory phase FXIII was also significantly higher compared with the periovulatory phase (P = 0.02). There was no significant correlation between FXIII level during the menstrual phase and age (P = 0.53) or PBAC score (P = 0.53). There were no significant differences in FXIII level during the menstrual phase between women with PBAC scores of at least 100 (n = 14; mean 116 IU/dl) and women with PBAC scores less than 100 (n = 18; mean 113 IU/dl). There was no correlation between FXIII level and bleeding score. FXIII activity was lower during menstrual and periovulatory phases of the cycle. However, the small difference between mean values (8 IU/dl) would be unlikely to have a significant impact on diagnosis of FXIII deficiency and clinical management.


Assuntos
Fator XIII/metabolismo , Menorragia/sangue , Ciclo Menstrual/sangue , Adolescente , Adulto , Feminino , Humanos , Estudos Longitudinais , Masculino , Adulto Jovem
15.
Thromb Haemost ; 113(1): 13-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25318976

RESUMO

Accurate diagnosis of obstetric antiphospholipid syndrome (APS) is a prerequisite for optimal clinical management. The international consensus (revised Sapporo) criteria for obstetric APS do not include low positive anticardiolipin (aCL) and anti ß2 glycoprotein I (aß2GPI) antibodies (< 99th centile) and/or certain clinical criteria such as two unexplained miscarriages, three non-consecutive miscarriages, late pre-eclampsia, placental abruption, late premature birth, or two or more unexplained in vitro fertilisation failures. In this review we examine the available evidence to address the question of whether patients who exhibit non-criteria clinical and/or laboratory manifestations should be included within the spectrum of obstetric APS. Prospective and retrospective cohort studies of women with pregnancy morbidity, particularly recurrent pregnancy loss, suggest that elimination of aCL and/or IgM aß2GPI, or low positive positive aCL or aß2GPI from APS laboratory diagnostic criteria may result in missing the diagnosis in a sizeable number of women who could be regarded to have obstetric APS. Such prospective and retrospective studies also suggest that women with non-criteria obstetric APS may benefit from standard treatment for obstetric APS with low-molecular-weight heparin plus low-dose aspirin, with good pregnancy outcomes. Thus, non-criteria manifestations of obstetric APS may be clinically relevant, and merit investigation of therapeutic approaches. Women with obstetric APS appear to be at a higher risk than other women of pre-eclampsia, placenta-mediated complications and neonatal mortality, and also at increased long-term risk of thrombotic events. The applicability of these observations to outcomes in women with non-criteria obstetric APS remains to be determined.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Anticoagulantes/administração & dosagem , Síndrome Antifosfolipídica/diagnóstico , Síndrome Antifosfolipídica/tratamento farmacológico , Complicações na Gravidez/diagnóstico , Complicações na Gravidez/tratamento farmacológico , Anticoagulantes/efeitos adversos , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/mortalidade , Aspirina/administração & dosagem , Biomarcadores/sangue , Quimioterapia Combinada , Feminino , Heparina de Baixo Peso Molecular/administração & dosagem , Humanos , Valor Preditivo dos Testes , Gravidez , Complicações na Gravidez/sangue , Complicações na Gravidez/mortalidade , Fatores de Risco , Resultado do Tratamento
16.
J Neurol Sci ; 348(1-2): 35-40, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25498844

RESUMO

BACKGROUND: Reduced ADAMTS13 activity is seen in thrombotic thrombocytopenic purpura (TTP), and may lead to accumulation of prothrombotic ultra-large von Willebrand factor (ULVWF) multimers in vivo. ADAMTS13 activity and its relationship with VWF antigen (VWF:Ag) levels and platelet function in 'non-TTP related' TIA or ischaemic stroke has not been comprehensively studied. METHODS: In this prospective pilot observational analytical case-control study, ADAMTS13 activity and VWF:Ag levels were quantified in platelet poor plasma in 53 patients in the early phase (≤ 4 weeks) and 34 of these patients in the late phase (≥ 3 months) after TIA or ischaemic stroke on aspirin. Data were compared with those from 22 controls not on aspirin. The impact of ADAMTS13 on platelet function in whole blood was quantified by measuring Collagen-ADP (C-ADP) and Collagen-Epinephrine closure times on a platelet function analyser (PFA-100(®)). RESULTS: Median ADAMTS13 activity was significantly reduced in the early phase (71.96% vs. 95.5%, P <0.01) but not in the late phase after TIA or stroke compared with controls (86.3% vs. 95.5%, P=0.19). There was a significant inverse relationship between ADAMTS13 activity and VWF:Ag levels in the early phase (r=-0.31; P=0.024), but not in the late phase after TIA or stroke (P=0.74). There was a positive correlation between ADAMTS13 activity and C-ADP closure times in early phase patients only, likely mediated via VWF:Ag levels. DISCUSSION: ADAMTS13 activity is reduced and VWF:Ag expression is increased within 4 weeks of TIA or ischaemic stroke onset, and can promote enhanced platelet adhesion and aggregation in response to stimulation with collagen and ADP via VWF-mediated pathways. These data improve our understanding of the dynamic haemostatic and thrombotic profiles of ischaemic cerebrovascular disease (CVD) patients, and are important in view of the potential future role that ADAMTS13 may have to play as an anti-thrombotic agent in CVD.


Assuntos
Proteínas ADAM/metabolismo , Plaquetas/fisiologia , Ataque Isquêmico Transitório/sangue , Acidente Vascular Cerebral/sangue , Fator de von Willebrand/metabolismo , Proteína ADAMTS13 , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Testes de Função Plaquetária , Fatores de Tempo
17.
Blood ; 120(2): 440-8, 2012 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-22529288

RESUMO

The quantification of residual plasmatic ADAMTS13 activity in congenital thrombotic thrombocytopenic purpura (TTP) patients is constrained by limitations in sensitivity and reproducibility of commonly used assays at low levels of ADAMTS13 activity, blunting efforts to establish genotype-phenotype correlations. In the present study, the residual plasmatic activity of ADAMTS13 was measured centrally by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (limit of detection = 0.5%) in 29 congenital TTP patients. The results were used to study correlations among ADAMTS13 genotype, residual plasmatic activity, and clinical phenotype severity. An ADAMTS13 activity above 0.5% was measured in 26 (90%) patients and lower levels of activity were associated with earlier age at first TTP episode requiring plasma infusion, more frequent recurrences, and prescription of fresh-frozen plasma prophylaxis. Receiver operating characteristic curve analysis showed that activity levels of less than 2.74% and 1.61% were discriminative of age at first TTP episode requiring plasma infusion < 18 years, annual rate of TTP episodes > 1, and use of prophylaxis. Mutations affecting the highly conserved N-terminal domains of the protein were associated with lower residual ADAMTS13 activity and a more severe phenotype in an allelic-dose dependent manner. The results of the present study show that residual ADAMTS13 activity is associated with the severity of clinical phenotype in congenital TTP and provide insights into genotype-phenotype correlations.


Assuntos
Proteínas ADAM/sangue , Proteínas ADAM/deficiência , Púrpura Trombocitopênica Trombótica/sangue , Púrpura Trombocitopênica Trombótica/congênito , Proteínas ADAM/genética , Proteína ADAMTS13 , Adolescente , Adulto , Fatores Etários , Idoso , Análise Química do Sangue , Transfusão de Sangue , Criança , Pré-Escolar , Análise Mutacional de DNA , Feminino , Estudos de Associação Genética , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Plasma , Púrpura Trombocitopênica Trombótica/genética , Púrpura Trombocitopênica Trombótica/terapia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Adulto Jovem
18.
Thromb Res ; 130(5): 780-4, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22265675

RESUMO

BACKGROUND: Activated protein C resistance (APCR) within a thrombin generation test (TGT) system is associated with an increased risk of venous thromboembolism (VTE). However, application of the TGT is restricted by the analytical platforms used to monitor thrombin generation. Using a routine coagulation analyser we have developed an automated chromogenic TGT that is sensitive to defects in the protein C pathway. METHOD: The TGT was performed on a TOP500 analyser, in the presence and absence of Protac. The reaction was monitored using a substrate with slow kinetics for thrombin (S-2444). Results were expressed as the area under the curve normalised ratio (AUCnr). Assay results were compared with Coatest APCR (expressed as APC-ratio [CoAPCr]). PATIENTS: Samples were obtained from 35 healthy subjects and 91 patients with previous history of VTE. Of these patients, 19, 17, and 9 had heterozygous factor V Leiden (FVL), antiphospholipid syndrome (APS), and protein C/protein S deficiencies (PC/PS) respectively. RESULTS: Inter-assay imprecision in the presence and absence of Protac were 20% and <5% respectively. There was a significant difference between the AUCnr of normals (median [IQR]: 2.8 [2.4-4.7]) compared to: FVL (1.0 [0.7-1.2]); PC/PS (1.1 [0.9-1.2]); and APS (1.1 [0.8-1.4]); p<0.001 for each comparison. No significant difference was seen between the AUCnr of normals and other VTE patients. The detection rate of AUCnr and CoAPCr were: 100% and 56% for FVL; 88% and 44% for PC/PS; and 64% and 45% for APS respectively. CONCLUSION: The automated TGT exhibited good sensitivity to defects in the protein C pathway.


Assuntos
Testes de Coagulação Sanguínea/métodos , Proteína C/metabolismo , Trombina/biossíntese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteína C/genética , Fatores de Risco , Trombina/genética , Trombina/metabolismo , Adulto Jovem
19.
Thromb Res ; 130(5): 775-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22245224

RESUMO

INTRODUCTION: Total hip/knee replacement surgery (THR/TKR respectively) is associated with an increased risk of venous thromboembolism. Dabigatran is recommended as a thromboprophylactic agent post orthopaedic surgery. The aim of this study was to assess the post-operative (Day-1 and Day-2) effect of prophylactic Dabigatran on: the thrombin generation (TG) assay; prothrombin fragment 1.2 (F1.2); thrombin-antithrombin complexes (TAT); D-dimer (D-D); and other coagulation parameters. METHODS AND SAMPLES: Nineteen patients (12 THR, 7 TKR) who received 110 mg dabigatran 4 hours post-operatively, then 220 mg the following day, were recruited. Blood was collected: pre-operatively (Pre-); peri-operatively (Peri-); 19 hours after 110 mg dabigatran (Day-1); and 17 hours after 220 mg dabigatran (Day-2). The TG assay was measured using the Calibrated Automated Thrombogram and a low concentration of tissue factor. Other coagulation parameters measured included activated partial thromboplastin time (APTT), thrombin-time (TT), ecarin-clotting time (ECT) and Hemoclot tests. RESULTS: From Pre- to Peri-, ETP/peak-thrombin, F1.2, TAT and D-D increased significantly. From Peri- to Day-1 and Day-2: TAT reduced progressively; D-D increased; F1.2 did not change significantly; lag-time and time-to-peak prolonged; ETP/Peak-thrombin increased spuriously, due to Dabigatran interfering with the α-2 macroglobulin:thrombin complex in the TG assay. APTT, TT, ECT and Hemoclot increased progressively post-operatively; good correlations were seen between these tests. CONCLUSION: The effect of dabigatran on the TG assay, showed a spurious increase in ETP and Peak-thrombin due to its interference with the TG assay. Dabigatran reduced TAT, but not F1.2, suggesting that thrombin was still being generated after surgery, but was blocked by Dabigatran.


Assuntos
Antitrombinas/uso terapêutico , Artroplastia de Quadril/métodos , Artroplastia do Joelho/métodos , Benzimidazóis/uso terapêutico , Coagulação Sanguínea/efeitos dos fármacos , Trombina/biossíntese , beta-Alanina/análogos & derivados , Idoso , Dabigatrana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , beta-Alanina/uso terapêutico
20.
Br J Haematol ; 151(5): 469-76, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20950405

RESUMO

Total hip/knee replacement surgeries are associated with an increased risk of venous thromboembolism and post-operative thromboprophylaxis has become standard treatment. This study aimed to: (i) assess the impact of hip/knee replacement surgery on ex vivo thrombin generation (TG), prothrombin fragments 1 + 2 (F1 + 2), thrombin-antithrombin complexes (TAT) and D-dimer; (ii) compare the anticoagulant effects of dalteparin and rivaroxaban on TG 24 h after surgery. Haemostatic variables were assessed in plasma samples of 51 patients taken pre-operatively, peri-operatively, and 24 h post-operatively. Prophylaxis, once a day, with dalteparin or rivaroxaban, starting 6­8 h post-operatively, was administered in 25 (14 knee/11 hip) and 26 patients (13 knee/13 hip) respectively. TG, F1 + 2, TAT and D-dimer increased during surgery. Dalteparin patients showed a variable TG response 24 h after surgery: conversely, the effect of rivaroxaban on TG was consistent across individuals. Good correlation was seen between rivaroxaban levels and TG-lag-time (rs = 0·46, P = 0·01); TG-time-to-Peak (rs = 0·53, P = 0·005); TG-peak-thrombin (rs = −0·59, P = 0·001); and TG-velocity-index-rate (rs = −0·61, P = 0·0009). Patients who received rivaroxaban showed a greater decrease of TG, F1 + 2 and TAT (but not D-dimer) than those on dalteparin. TG increases during hip/knee replacement surgery. Rivaroxaban inhibits TG more than dalteparin at 24 h after surgery.


Assuntos
Anticoagulantes/uso terapêutico , Artroplastia de Quadril , Artroplastia do Joelho , Trombina/biossíntese , Tromboembolia Venosa/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Dalteparina/uso terapêutico , Fator Xa/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morfolinas/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Rivaroxabana , Tiofenos/uso terapêutico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA