Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Imaging Inform Med ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831190

RESUMO

The aim of this study was to validate a novel medical virtual reality (VR) platform used for medical image segmentation and contouring in radiation oncology and 3D anatomical modeling and simulation for planning medical interventions, including surgery. The first step of the validation was to verify quantitatively and qualitatively that the VR platform can produce substantially equivalent 3D anatomical models, image contours, and measurements to those generated with existing commercial platforms. To achieve this, a total of eight image sets and 18 structures were segmented using both VR and reference commercial platforms. The image sets were chosen to cover a broad range of scanner manufacturers, modalities, and voxel dimensions. The second step consisted of evaluating whether the VR platform could provide efficiency improvements for target delineation in radiation oncology planning. To assess this, the image sets for five pediatric patients with resected standard-risk medulloblastoma were used to contour target volumes in support of treatment planning of craniospinal irradiation, requiring complete inclusion of the entire cerebral-spinal volume. Structures generated in the VR and the commercial platforms were found to have a high degree of similarity, with dice similarity coefficient ranging from 0.963 to 0.985 for high-resolution images and 0.920 to 0.990 for lower resolution images. Volume, cross-sectional area, and length measurements were also found to be in agreement with reference values derived from a commercial system, with length measurements having a maximum difference of 0.22 mm, angle measurements having a maximum difference of 0.04°, and cross-sectional area measurements having a maximum difference of 0.16 mm2. The VR platform was also found to yield significant efficiency improvements, reducing the time required to delineate complex cranial and spinal target volumes by an average of 50% or 29 min.

2.
Med Dosim ; 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37798155

RESUMO

This study presents a new treatment planning approach merging 3D-CRT and VMAT fields into a hybrid treatment plan (HybTP), in order to achieve an optimum dose coverage of the planning target volume (PTV) and protection of OAR. Craniospinal axis irradiation (CSI) treated with 3D conformal radiotherapy (3D-CRT) is associated with high doses to the heart and eye lenses but provides better sparing of lungs and kidneys compared to volumetric modulated arc therapy (VMAT). VMAT treatment spares eye lenses and the heart, but lungs and kidneys are not as effective as 3D-CRT. Thus, a combination of both techniques (HybTP) may be optimal in sparing all these organs at risk (OAR). The results of HybTP are compared with helical tomotherapy (HT), intensity modulated radio therapy (IMRT), VMAT, and 3D-CRT plans. Hybrid, HT, VMAT, IMRT, and 3D-CRT treatment plans for a male child (age 6 years) with medulloblastoma were created and compared. A total dose of 35.2 Gy (PTV) with a dose per fraction of 1.6 Gy was prescribed. The following dose acceptance criteria were defined: The plans were compared regarding dose homogeneity index (HI) and conformity index (CI), PTV coverage, (particularly at cribriform plate) and doses at OARs. Best conformity was achieved with HT (CI = 0.98) followed by VMAT (CI = 0.96), IMRT (CI = 0.91), HybTP (CI = 0.86), and 3D-CRT (CI = 0.83). The homogeneity index varied marginally. For both HT and IMRT the HI was 0.07, and for 3D-CRT, VMAT and HybTP the HI was between 0.13 and 0.15. The cribriform plate was sufficiently covered by HybTP, VMAT, and 3D-CRT. The dose acceptance criteria for OARs were met by HT and HybTP. VMAT did not meet the criteria for lung (Dmean = right 10.4 Gy/left 10.2 Gy), 3D-CRT did not meet the criteria for eye lenses (Dmax = right 32.3 Gy/left 33.1), and heart (V25≈44%) and IMRT did not meet the criteria for lung (Dmean = right 11.1 Gy/left 11.2 Gy) and eye lenses (Dmax = right 12.2 Gy/left 13.1). HybTP meets all defined acceptance criteria and has proved to be a reasonable alternative for CSI. With HybTP that combines VMAT at the brain and heart with 3D-CRT posterior spinal fields (to spare lungs and kidneys), both appropriate coverage of the PTV and sparing of OAR can be achieved.

3.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35336458

RESUMO

The goal of this paper is to evaluate the potential of a low-cost, ultra-wideband radar system for detecting and monitoring respiratory motion during radiation therapy treatment delivery. Radar signals from breathing motion patterns simulated using a respiratory motion phantom were captured during volumetric modulated arc therapy (VMAT) delivery. Gantry motion causes strong interference affecting the quality of the extracted respiration motion signal. We developed an artificial neural network (ANN) model for recovering the breathing motion patterns. Next, automated classification into four classes of breathing amplitudes is performed, including no breathing, breath hold, free breathing and deep inspiration. Breathing motion patterns extracted from the radar signal are in excellent agreement with the reference data recorded by the respiratory motion phantom. The classification accuracy of simulated deep inspiration breath hold breathing was 94% under the worst case interference from gantry motion and linac operation. Ultra-wideband radar systems can achieve accurate breathing rate estimation in real-time during dynamic radiation delivery. This technology serves as a viable alternative to motion detection and respiratory gating systems based on surface detection, and is well-suited to dynamic radiation treatment techniques. Novelties of this work include detection of the breathing signal using radar during strong interference from simultaneous gantry motion, and using ANN to perform adaptive signal processing to recover breathing signal from large interference signals in real time.


Assuntos
Radioterapia de Intensidade Modulada , Movimento (Física) , Radar , Radioterapia de Intensidade Modulada/métodos , Respiração , Taxa Respiratória
4.
Health Phys ; 121(5): 531-534, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34411056

RESUMO

ABSTRACT: Brachytherapy programs within radiation therapy departments are subject to stringent radiation safety requirements in order to ensure the safety of the staff and patients. Training programs often include brachytherapy-specific radiation safety training modules that address the specific risks associated with radioactive sources, emergency procedures, and regulatory requirements specific to the use of radioisotopes. Unlike other uses of radioactive materials, brachytherapy uses sealed sources and therefore under routine operations does not encounter radioactive contaminants. This article presents an unusual clinical situation in which an 125I brachytherapy seed was damaged during routine clinical workflow, resulting in radioactive contamination within the clinical environment. Decisions made at the time of the incident resulted in contamination that spread beyond the initial location. The incident highlighted a shortcoming of the radiation safety program in preparing staff for the possibility of having to deal with unsealed radioactivity. Brachytherapy programs would be strengthened by including training specific to radioactive contamination in their emergency training to equip staff to respond to unexpected damage to the sealed sources.


Assuntos
Braquiterapia , Lesões por Radiação , Proteção Radiológica , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Humanos , Radioisótopos do Iodo/efeitos adversos , Lesões por Radiação/tratamento farmacológico , Proteção Radiológica/métodos
5.
Curr Oncol ; 28(4): 2385-2398, 2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-34202403

RESUMO

INTRODUCTION: Variable costs of different radiation treatment modalities have played an important factor in selecting the most appropriate treatment for patients with intermediate-risk prostate cancer. METHODS: Analysis using a Markov model was conducted to simulate 20-year disease trajectory, quality-adjusted life years (QALYs) and health system costs of a cohort of intermediate-risk prostate cancer patients with mean age of 60 years. Clinical outcomes on toxicity and disease recurrence were measured and a probabilistic sensitivity analysis was performed, varying input parameters simultaneously according to their distributions. RESULTS: Among the six radiation treatment modalities, including conventionally fractionated intensity-modulated radiation therapy (IMRT), hypofractionated IMRT, IMRT combined with high-dose-rate (HDR) brachytherapy, HDR brachytherapy monotherapy, low-dose-rate brachytherapy monotherapy, and stereotactic body radiotherapy (SBRT), SBRT was found to be more cost-effective when compared with LDR-b and other treatment modalities, resulting in an incremental cost-utility ratio of $2985 per QALY. CONCLUSIONS: Stereotactic body radiotherapy is the most cost-effective radiation treatment modality in treatment of intermediate-risk prostate cancer, while treatment toxicity and cost data are the key drivers of the cost-utility. Further work is required with long-term follow-up for SBRT.


Assuntos
Braquiterapia , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Análise Custo-Benefício , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Neoplasias da Próstata/radioterapia
7.
J Appl Clin Med Phys ; 16(3): 5139, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103478

RESUMO

Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB environment with a graphical user interface in order to produce an environment similar to that of linear accelerator service mode. The program was evaluated in a systematic fashion, where parameters affecting the clinical properties of medical linear accelerator beams were adjusted independently, and the effects on beam energy and dose rate recorded. These results confirmed that beam tuning adjustments could be simulated in a simple environment. Further, adjustment of service parameters over a large range was possible, and this allows the demonstration of linear accelerator physics in an environment accessible to both medical physicists and linear accelerator service engineers. In conclusion, a software tool, named SIMAC, was developed to improve the teaching of linear accelerator physics in a simulated environment. SIMAC performed in a similar manner to medical linear accelerators. The authors hope that this tool will be valuable as a teaching tool for medical physicists and linear accelerator service engineers.


Assuntos
Instrução por Computador/métodos , Análise de Falha de Equipamento/métodos , Física Médica/educação , Modelos Teóricos , Aceleradores de Partículas/instrumentação , Software , Simulação por Computador , Ensino/métodos , Interface Usuário-Computador
8.
Med Phys ; 40(4): 042103, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23556913

RESUMO

PURPOSE: This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria for γ-distance to agreement measurements. METHODS: A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random multileaf collimator (MLC) position errors that are normally distributed with σ ≈ ± 0.5, ± 1.0, ± 2.0, and ± 3.0 mm (a total of 68 modified plans were created). All plans were evaluated using five different γ-criteria. ROC methodology was applied by quantifying the fraction of modified plans reported as "fail" and unmodified plans reported as "pass." RESULTS: γ-based criteria were able to attain nearly 100% sensitivity/specificity in the detection of large random errors (σ > 3 mm). Sensitivity and specificity decrease rapidly for all γ-criteria as the size of error to be detected decreases below 2 mm. Predictive power is null with all criteria used in the detection of small MLC errors (σ < 0.5 mm). Optimal threshold values were established by determining which criteria maximized sensitivity and specificity. For 3%/3 mm γ-criteria, optimal threshold values range from 92% to 99%, whereas for 2%/2 mm, the range was from 77% to 94%. CONCLUSIONS: The optimal threshold values that were determined represent a maximized test sensitivity and specificity and are not subject to any user bias. When applied to the datasets that we studied, our results suggest the use of patient specific QA as a safety tool that can effectively prevent large errors (e.g., σ > 3 mm) as opposed to a tool to improve the quality of IMRT delivery.


Assuntos
Aceleradores de Partículas/normas , Assistência Centrada no Paciente/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Curva ROC , Radiometria/normas , Radioterapia Conformacional/normas , Canadá , Interpretação Estatística de Dados , Dosagem Radioterapêutica
9.
J Appl Clin Med Phys ; 13(1): 3704, 2012 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-22231223

RESUMO

The January 2010 articles in The New York Times generated intense focus on patient safety in radiation treatment, with physics staffing identified frequently as a critical factor for consistent quality assurance. The purpose of this work is to review our experience with medical physics staffing, and to propose a transparent and flexible staffing algorithm for general use. Guided by documented times required per routine procedure, we have developed a robust algorithm to estimate physics staffing needs according to center-specific workload for medical physicists and associated support staff, in a manner we believe is adaptable to an evolving radiotherapy practice. We calculate requirements for each staffing type based on caseload, equipment inventory, quality assurance, educational programs, and administration. Average per-case staffing ratios were also determined for larger-scale human resource planning and used to model staffing needs for Ontario, Canada over the next 10 years. The workload specific algorithm was tested through a survey of Canadian cancer centers. For center-specific human resource planning, we propose a grid of coefficients addressing specific workload factors for each staff group. For larger scale forecasting of human resource requirements, values of 260, 700, 300, 600, 1200, and 2000 treated cases per full-time equivalent (FTE) were determined for medical physicists, physics assistants, dosimetrists, electronics technologists, mechanical technologists, and information technology specialists, respectively.


Assuntos
Algoritmos , Física Médica/estatística & dados numéricos , Seleção de Pessoal/estatística & dados numéricos , Admissão e Escalonamento de Pessoal/estatística & dados numéricos , Radioterapia (Especialidade)/estatística & dados numéricos , Ontário , Seleção de Pessoal/tendências , Admissão e Escalonamento de Pessoal/tendências , Radioterapia (Especialidade)/tendências , Recursos Humanos
11.
Med Dosim ; 36(1): 81-4, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20346646

RESUMO

We report on the impact of a thermoplastic immobilization system on intra- and interfraction motion for patients undergoing breast or chest wall radiation therapy. Patients for this study were treated using helical tomotherapy. All patients were immobilized using a thermoplastic shell extending from the shoulders to the ribcage. Intrafraction motion was assessed by measuring maximum displacement of the skin, heart, and chest wall on a pretreatment 4D computed tomography, while inter-fraction motion was inferred from patient shift data arising from daily image guidance procedures on tomotherapy. Using thermoplastic immobilization, the average maximum motion of the external contour was 1.3 ± 1.6 mm, whereas the chest wall was found to be 1.6 ± 1.9 mm. The day-to-day setup variation was found to be large, with random errors of 4.0, 12.0, and 4.5 mm in the left-right, superior-inferior, and anterior-posterior directions, respectively, and the standard deviations of the systematic errors were found to be 2.7, 9.8, and 4.1 mm. These errors would be expected to dominate any respiratory motion but can be mitigated by daily online image guidance. Using thermoplastic immobilization can effectively reduce respiratory motion of the chest wall and external contour, but these gains can only be realized if daily image guidance is used.


Assuntos
Neoplasias da Mama/radioterapia , Imobilização/instrumentação , Proteção Radiológica/instrumentação , Radioterapia Conformacional/instrumentação , Neoplasias Torácicas/radioterapia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Plásticos , Dosagem Radioterapêutica
12.
Radiother Oncol ; 90(1): 99-105, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18977546

RESUMO

PURPOSE: To compare a standard 3- or 4-field technique to intensity modulated radiotherapy with helical tomotherapy (IMRT-HT) in the planning of locoregional breast radiation including the internal mammary chain (IMC). METHODS AND MATERIALS: For 10 women with stage III left-sided breast cancer with a planning target volume (PTV) defined by the breast/chest wall and regional nodes, radiotherapy to a dose of 50 Gy in 25 fractions was planned using a standard 3- or 4-field technique and using IMRT-HT. Various metrics were extracted from dose-volume histograms, and were compared using the paired Student's t-test. RESULTS: The PTV receiving at least 95% of the prescribed dose did not differ between the two plans, but the VD115% was significantly lower with IMRT-HT. The dose conformality was significantly better with IMRT-HT. The cardiac V30(Gy) was reduced with IMRT-HT. The mean lungs dose was lower with IMRT-HT, as well the V20(Gy). With IMRT-HT, a greater volume of contralateral breast was irradiated to 5 Gy, but a smaller volume of soft tissue received dose above 50 Gy. CONCLUSIONS: Compared to a standard technique, IMRT-HT provides similar target coverage, improves dose conformality and dose homogeneity within the PTV, decreases mean lung dose and spares heart, lung and soft tissue from high dose exposure.


Assuntos
Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação , Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/patologia , Fracionamento da Dose de Radiação , Feminino , Humanos , Estadiamento de Neoplasias , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Resultado do Tratamento
13.
Int J Radiat Oncol Biol Phys ; 72(4): 963-6, 2008 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-18954708

RESUMO

PURPOSE: To investigate the feasibility of using calcifications as surrogates for the prostate position during cone-beam computed tomography (CBCT) image-guided radiotherapy. METHODS AND MATERIALS: The twice-weekly CBCT images taken during the treatment course of 4 patients were retrospectively studied for the stability of the calcifications. The geometric center of three fiducial markers was used as the reference. The planning CT images of 131 prostate patients recently treated with external beam radiotherapy at our center were reviewed to estimate the calcification occurrence rate. Analysis was conducted using the Varian Eclipse treatment planning system. Two patients were treated using prostate calcifications as the landmark in on-line registration. Both the Varian standard and the low-dose CBCT modes were used for imaging. RESULTS: The calcifications were found to be stable during the treatment course. At the 95% confidence interval, the difference between the distance from an identified calcification to the fiducial markers on CBCT and the distance on the planning CT scans was 0.2 +/- 2.0 mm, 0.8 +/- 2.2 mm, and 0.4 +/- 2.4 mm in the left-right, anteroposterior, and superoinferior direction, respectively. Of the 131 patients, 46 (35%) had well-defined calcifications either inside the prostate or near the borders. Our experience in treating the first 2 patients demonstrated that the calcifications are easily distinguished on low-dose scans and that calcification registration can be precisely performed. CONCLUSION: The results of our study have shown that calcifications can be reliable markers of prostate position and allow for precise image guidance with a low-imaging dose. With this approach, potentially about one-third of prostate patients could benefit from precise image guidance without the invasive use of markers.


Assuntos
Calcinose/diagnóstico por imagem , Calcinose/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Calcinose/complicações , Estudos de Viabilidade , Humanos , Masculino , Neoplasias da Próstata/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiother Oncol ; 87(1): 116-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18329119

RESUMO

Rapid delivery of radiation therapy is expected to benefit patients requiring palliation. We investigated the feasibility of employing a helical tomotherapy unit to scan, plan, and deliver a radiation treatment in a single radiation therapy appointment. Eleven patients each had an MVCT scan acquired, a plan created, and delivery completed while the patient was on the treatment couch. Timelines for each step of the process were recorded for each patient, and compared with the conventional process for similar patients. Preliminary results show that patients routinely can be treated within a 1 hour appointment for the first fraction.


Assuntos
Neoplasias/radioterapia , Cuidados Paliativos/métodos , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...