Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 141(2): 333-339, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33241448

RESUMO

INTRODUCTION: The impact of residual internal fixation devices on subsequent procedures about the hip has not been clearly well defined. The objective of the current study is to evaluate the outcome of hip arthroplasty after hardware retrieval as a one-stage replacement, to analyze possible differences related to the type of removed implant, and to assess the impact of unexpected intraoperative cultures during implant retrieval. MATERIALS AND METHODS: We present a retrospective study including all those cases undergoing hip arthroplasty with concomitant hardware removal (cannulated screws, intramedullary nail, or dynamic hip screw) from 2005 to 2018. We evaluated demographics, intraoperative cultures, early infection rate, and other complications. RESULTS: A total of 55 cases were included in the study. The median time between the implant surgery and the hip arthroplasty was 113 days. The removed devices included 6 cannulated screws, 34 intramedullary nails, and 15 dynamic hip screws. Up to 74.5% of the failed osteosynthesis belonged to intertrochanteric femoral fractures. Dislocation rate was 9.1% (1.8% requiring revision surgery), 25.5% of the cases needed further new surgeries after the hip arthroplasty, and 49.1% died during the follow-up period. Any-cause revision surgery and mortality rates were significantly increased after intramedullary nail removal. Intraoperative cultures were performed in 46 cases, and in 9 (16.4%), there was bacterial contamination: 6 cases (10.9%) presented one single positive culture and 3 (5.5%) presented ≥ 2 positive cultures for the same microorganism. A total of five cases (9.1%) presented early prosthetic joint infection that required debridement. None of these five cases had presented positive cultures at the implant removal. CONCLUSION: According to our results, hip arthroplasty with concomitant hardware removal is related to a high 5-year mortality rate, mainly when intramedullary nail is retrieved. Whereas a high risk of early prosthetic joint infection is associated, it seems not to be related to the elevated presence of unexpected positive cultures.


Assuntos
Artroplastia de Quadril , Remoção de Dispositivo , Infecções Relacionadas à Prótese , Reoperação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/mortalidade , Artroplastia de Quadril/estatística & dados numéricos , Pinos Ortopédicos/efeitos adversos , Parafusos Ósseos/efeitos adversos , Humanos , Estudos Retrospectivos
2.
Acta homoeopath. argent ; 18(57): 11-8, oct.-dic. 1997.
Artigo em Espanhol | HomeoIndex - Homeopatia | ID: hom-5454
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...