Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(8): 083901, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27587130

RESUMO

Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. The system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10(7) molybdenum Kα photons.

2.
Sci Rep ; 5: 15064, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26478106

RESUMO

The structural and mechanical response of metals is intimately connected to phase transformations. For instance, the product of a phase transformation (martensite) is responsible for the extraordinary range of strength and toughness of steel, making it a versatile and important structural material. Although abundant in metals and alloys, the discovery of new phase transformations is not currently a common event and often requires a mix of experimentation, predictive computations, and luck. High-energy pulsed lasers enable the exploration of extreme pressures and temperatures, where such discoveries may lie. The formation of a hexagonal (omega) phase was observed in recovered monocrystalline body-centered cubic tantalum of four crystallographic orientations subjected to an extreme regime of pressure, temperature, and strain-rate. This was accomplished using high-energy pulsed lasers. The omega phase and twinning were identified by transmission electron microscopy at 70 GPa (determined by a corresponding VISAR experiment). It is proposed that the shear stresses generated by the uniaxial strain state of shock compression play an essential role in the transformation. Molecular dynamics simulations show the transformation of small nodules from body-centered cubic to a hexagonal close-packed structure under the same stress state (pressure and shear).


Assuntos
Lasers , Modelos Teóricos , Transição de Fase , Tantálio/química
3.
Phys Rev Lett ; 114(6): 065502, 2015 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-25723227

RESUMO

A basic tenet of material science is that the flow stress of a metal increases as its grain size decreases, an effect described by the Hall-Petch relation. This relation is used extensively in material design to optimize the hardness, durability, survivability, and ductility of structural metals. This Letter reports experimental results in a new regime of high pressures and strain rates that challenge this basic tenet of mechanical metallurgy. We report measurements of the plastic flow of the model body-centered-cubic metal tantalum made under conditions of high pressure (>100 GPa) and strain rate (∼10(7) s(-1)) achieved by using the Omega laser. Under these unique plastic deformation ("flow") conditions, the effect of grain size is found to be negligible for grain sizes >0.25 µm sizes. A multiscale model of the plastic flow suggests that pressure and strain rate hardening dominate over the grain-size effects. Theoretical estimates, based on grain compatibility and geometrically necessary dislocations, corroborate this conclusion.


Assuntos
Modelos Teóricos , Tantálio/química , Teste de Materiais/métodos , Metais/química , Tamanho da Partícula
4.
Rev Sci Instrum ; 85(11): 11D631, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430207

RESUMO

Sources of 5-12 keV thermal Heα x-rays are readily generated by laser irradiation of mid-Z foils at intensities >10(14) W/cm(2), and are widely used as probes for inertial confinement fusion and high-energy-density experiments. Higher energy 17-50 keV x-ray sources are efficiently produced from "cold" Kα emission using short pulse, petawatt lasers at intensities >10(18) W/cm(2) [H.-S. Park, B. R. Maddox et al., "High-resolution 17-75 keV backlighters for high energy density experiments," Phys. Plasmas 15(7), 072705 (2008); B. R. Maddox, H. S. Park, B. A. Remington et al., "Absolute measurements of x-ray backlighter sources at energies above 10 keV," Phys. Plasmas 18(5), 056709 (2011)]. However, when long pulse (>1 ns) lasers are used with Z > 30 elements, the spectrum contains contributions from both K shell transitions and from ionized atomic states. Here we show that by sandwiching a silver foil between layers of high-density carbon, the ratio of Kα:Heα in the x-ray spectrum is significant increased over directly illuminated Ag foils, with narrower lines from K-shell transitions. Additionally, the emission volume is more localized for the sandwiched target, producing a more planar x-ray sheet. This technique may be useful for generating probes requiring spectral purity and a limited spatial extent, for example, in incoherent x-ray Thomson scattering experiments.

6.
Phys Rev Lett ; 110(11): 115501, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25166552

RESUMO

The strength of shock-loaded single crystal tantalum [100] has been experimentally determined using in situ broadband x-ray Laue diffraction to measure the strain state of the compressed crystal, and elastic constants calculated from first principles. The inferred strength reaches 35 GPa at a shock pressure of 181 GPa and is in excellent agreement with a multiscale strength model [N. R. Barton et al., J. Appl. Phys. 109, 073501 (2011)], which employs a hierarchy of simulation methods over a range of length scales to calculate strength from first principles.

7.
Rev Sci Instrum ; 83(10): 10E114, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126936

RESUMO

We have measured the x-ray emission, primarily from K(α),K(ß), and He(α) lines, of elemental copper foil and "foam" targets irradiated with a mid-10(16) W/cm(2) laser pulse. The copper foam at 0.1 times solid density is observed to produce 50% greater He(α) line emission than copper foil, and the measured signal is well-fit by a sum of three synthetic spectra generated by the atomic physics code FLYCHK. Additionally, spectra from both targets reveal characteristic inner shell K(α) transitions from hot electron interaction with the bulk copper. However, only the larger-volume foam target produced significant K(ß) radiation, confirming a lower bulk temperature in the higher volume sample.

8.
Rev Sci Instrum ; 82(2): 023111, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21361577

RESUMO

The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji™ MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver Kα x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.

9.
Rev Sci Instrum ; 81(10): 10E519, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034047

RESUMO

Understanding hot electron distributions generated inside Hohlraums is important to the national ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with target materials. We used an array of 18 pinholes with four independent filter combinations to image entire Hohlraums with a magnification of 0.87× during the Hohlraum energetics campaign on NIF. Comparing our results with Hohlraum simulations indicates that the characteristic 10-40 keV hot electrons are mainly generated from backscattered laser-plasma interactions rather than from Hohlraum hydrodynamics.

10.
Rev Sci Instrum ; 81(10): 10E522, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034050

RESUMO

A new diagnostic for measuring Bragg diffraction of petawatt-generated high-energy x rays off a laser-compressed crystal was designed and tested successfully at the Omega EP laser facility on static Mo and Ta (111) oriented single crystal samples using a 17.5 keV Mo Kα backlighter. The Bragg diffraction imager consists of a heavily shielded enclosure and a precisely positioned beam block attached to the enclosure by an aluminum arm. Fuji image plates are used as the x-ray detectors. The diffraction from Mo and Ta (222) crystal planes was clearly detected with a high signal-to-noise. This technique will be applied to shock- and quasi-isentropically loaded single crystals on the Omega EP laser.

11.
Rev Sci Instrum ; 81(10): 10E536, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034063

RESUMO

Experiments on the National Ignition Facility (NIF) will require bright, short duration, near-monochromatic x-ray backlighters for radiographic diagnosis of many high-energy density systems. This paper details a vanadium pinhole backlighter producing (1.8±0.5)×10(15) x-ray photons into 4π sr near the vanadium He-like characteristic x-ray energy of 5.18 keV. The x-ray yield was quantified from a set of Ross filters imaged to a calibrated image plate, with the Dante diagnostic used to confirm the quasimonochromatic nature of the spectrum produced. Additionally, an x-ray film image shows a source-limited image resolution of 26 µm from a 20 µm diameter pinhole.

12.
Rev Sci Instrum ; 79(10): 10E924, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044579

RESUMO

The x-ray photon counting efficiency of various charged-coupled device (CCD) based cameras was studied as a function of photon energy and exposure. A pair of Spectral Instruments model 800 CCD cameras fitted with 16 microm thick back-illuminated CCDs were calibrated at low x-ray energy using two well established histogram methods. In addition, two new thick substrate CCDs were evaluated for use at high energy. One was a commercially available Princeton Instruments PI-LCX1300 deep depletion CCD camera, while the other used a custom designed 650 microm thick partially depleted CCD fitted to a Spectral Instruments model 800 camera body. It is shown that at high x-ray energy, a pixel-summing algorithm is necessary to reconstruct the x-ray spectra in the thicker substrate CCDs. This paper will describe the different algorithms used to extract spectra and the absolute detection efficiencies using these algorithms. These detectors and algorithms will be very useful in detecting high-energy x-ray photons from high-intensity short-pulse laser interactions.

13.
Phys Rev Lett ; 96(21): 215701, 2006 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-16803251

RESUMO

We present resonant inelastic x-ray scattering and x-ray emission spectroscopy results on Gd metal to 113 GPa which suggest Kondo-like aspects in the delocalization of 4f electrons. Analysis of the resonant inelastic x-ray scattering data reveals a prolonged and continuous delocalization with volume throughout the entire pressure range, so that the volume-collapse transition at 59 GPa is only part of the phenomenon. Moreover, the Lgamma1 x-ray emission spectroscopy spectra indicate no apparent change in the bare 4f moment across the collapse, suggesting that Kondo screening is responsible for the expected Pauli-like behavior in magnetic susceptibility.

14.
Front Biosci ; 1: a39-45, 1996 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-9159193

RESUMO

We and others have recently found that mature murine B cells can be induced to undergo apoptosis, in vitro, in a dose-dependent manner, by extensive crosslinking of membrane IgM with polyclonal anti-mu. During the analysis of tolerance in transgenic mice expressing rearranged IgM or IgM + IgD receptors, we observed that, Sp6 anti-TNP Ig and anti-MHC transgenic splenocytes, would undergo receptor-mediated apoptosis in vitro just like their normal, non-transgenic littermates. However, transgenic mice expressing rearranged receptors typical of B1 cells, not only contained large numbers of CD5+ cells in their spleens, but these cells failed to undergo apoptosis under conditions that led to programmed cell death in normal splenocytes. B1 spleen cells also failed to proliferate with anti-IgM, although the responsiveness of cells from the other transgenic lines varied depending on the background strains. These differences are due in part, to strain differences, but they also imply that the response pattern of transgenic B cells reflects not only the subset composition in this organ, but also the transgenic specificity of the receptor.


Assuntos
Apoptose/fisiologia , Linfócitos B/fisiologia , Receptores Fc/fisiologia , Animais , Anticorpos Anti-Idiotípicos/farmacologia , Apoptose/efeitos dos fármacos , Linfócitos B/citologia , Linfócitos B/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Feminino , Citometria de Fluxo , Imunoglobulina M/imunologia , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA , Camundongos Transgênicos , Receptores Fc/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...