Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Front Cardiovasc Med ; 10: 1251055, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745113

RESUMO

Background: The prevalence of young patients with cardiac implantable electronic devices (CIED) is steadily increasing, accompanied by a rise in the occurrence of complications related to CIEDs. Consequently, transvenous lead extraction (TLE) has become a crucial treatment approach for such individuals. Objective: The purpose of this study was to examine the characteristics and procedural outcomes of young patients who undergo TLE, with a specific focus on identifying independent risk factors associated with adverse events. Methods: All patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) were categorized into two groups based on their age at the time of enrollment: 45 years or younger, and over 45 years. A subgroup analysis was conducted specifically for the younger population. In this analysis, predictor variables for all-cause mortality, procedural complications, and procedural failure were evaluated using multivariable analyses. Results: We identified 160 patients aged 45 years or younger with a mean age of 35.3 ± 7.6 years and 42.5% (n = 68) female patients. Leading extraction indication was lead dysfunction in 51.3% of cases, followed by local infections in 20.6% and systemic infections in 16.9%. The most common device to be extracted were implantable cardioverter-defibrillators (ICD) with 52.5%. Mean number of leads per patient was 2.2 ± 1.0. Median age of the oldest indwelling lead was 91.5 [54.75-137.5] months. Overall complication rate was 3.8% with 1.9% minor and 1.9% major complications. Complete procedural success was achieved in 90.6% of cases. Clinical procedural success rate was 98.1%. Procedure-related mortality was 0.0%. The all-cause in-hospital mortality rate was 2.5%, with septic shock identified as the primary cause of mortality. Multivariable analysis revealed CKD (OR: 19.0; 95% CI: 1.84-194.9; p = 0.018) and systemic infection (OR: 12.7; 95% CI: 1.14-142.8; p = 0.039) as independent predictor for all-cause mortality. Lead age ≥ 10 years (OR: 14.58, 95% CI: 1.36-156.2; p = 0.027) was identified as sole independent risk factor for procedural complication. Conclusion: TLE in young patients is safe and effective with a procedure-related mortality rate of 0.0%. CKD and systemic infection are predictors for all-cause mortality, whereas lead age ≥ 10 years was identified as independent risk factor for procedural complications in young patients undergoing TLE.

3.
ESC Heart Fail ; 10(6): 3373-3384, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37667319

RESUMO

AIMS: Heart failure with reduced ejection fraction (HFrEF) is associated with excessive sympathetic and impaired parasympathetic activity. The Barostim Neo™ device is used for electronical baroreflex activation therapy (BAT) to counteract autonomic nervous system dysbalance. Randomized trials have shown that BAT improves walking distance and reduces N-terminal prohormone of brain natriuretic peptide (NT-proBNP) levels at least in patients with only moderate elevation at baseline. Its impact on the risk of heart failure hospitalization (HFH) and death is not yet established, and experience in clinical routine is limited. METHODS AND RESULTS: We report on patient characteristics and clinical outcome in a retrospective, non-randomized single-centre registry of BAT in HFrEF. Patients in the New York Heart Association (NYHA) Classes III and IV with a left ventricular ejection fraction (LVEF) <35% despite guideline-directed medical therapy were eligible. Symptom burden, echocardiography, and laboratory testing were assessed at baseline and after 12 months. Clinical events of HFH and death were recorded at routine clinical follow-up. Data are shown as number (%) or median (inter-quartile range). Between 2014 and 2020, 30 patients were treated with BAT. Median age was 67 (63-77) years, and 27 patients (90%) were male. Most patients (83%) had previous HFH. Device implantation was successful in all patients. At 12 months, six patients had died and three were alive but did not attend follow-up. NYHA class was III/IV in 26 (87%)/4 (13%) patients at baseline, improved in 19 patients, and remained unchanged in 5 patients (P < 0.001). LVEF improved from 25.5 (20.0-30.5) % at baseline to 30.0 (25.0-36.0) % at 12 months (P = 0.014). Left ventricular end-diastolic diameter remained unchanged. A numerical decrease in NT-proBNP [3165 (880-8085) vs. 1001 (599-3820) pg/mL] was not significant (P = 0.526). Median follow-up for clinical events was 16 (10-33) months. Mortality at 1 (n = 6, 20%) and 3 years (n = 10, 33%) was as expected by the Meta-Analysis Global Group in Chronic Heart Failure risk score. Despite BAT, event rate was high in patients with NYHA Class IV, NT-proBNP levels >1600 pg/mL, or estimated glomerular filtration rate (eGFR) <30 mL/min at baseline. NYHA class and eGFR were independent predictors of mortality. CONCLUSIONS: Patients with HFrEF who are selected for BAT are in a stage of worsening or even advanced heart failure. BAT appears to be safe and improves clinical symptoms and-to a modest degree-left ventricular function. The risk of death remains high in advanced disease stages. Patient selection seems to be crucial, and the impact of BAT in earlier disease stages needs to be established.


Assuntos
Terapia por Estimulação Elétrica , Insuficiência Cardíaca , Idoso , Feminino , Humanos , Masculino , Barorreflexo/fisiologia , Terapia por Estimulação Elétrica/efeitos adversos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Pessoa de Meia-Idade
4.
Europace ; 24(10): 1627-1635, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35718878

RESUMO

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência Renal Crônica , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Lasers de Excimer , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
5.
Eur J Cardiothorac Surg ; 61(5): 1031-1040, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35174386

RESUMO

OBJECTIVES: The wearable cardioverter defibrillator (WCD) is an established, safe, effective solution, protecting patients at risk of sudden cardiac death. We specifically investigated WCD use in cardiac surgery patients since data for this patient group are rare. METHODS: Retrospective data analysis in 10 German cardiac surgery centres was performed. Cardiac surgery patients with left ventricular ejection fraction (LVEF) ≤35% or after implantable cardioverter defibrillator (ICD) explantation who received WCD between 2010 and 2020 were assessed using LifeVest Network data. RESULTS: A total of 1168 patients with a median age of 66 years [interquartile range (IQR) 57-73] were enrolled; 87% were male. Clinical indications included coronary artery bypass grafting (43%), valve surgery (16%), combined coronary artery bypass graft/valve surgery (15%), ICD explantation (24%) and miscellaneous (2%). The median wear time of WCD was 23.4 h/day (IQR 21.7-23.8). A total of 106 patients (9.1%) exhibited ventricular tachycardia. A total of 93.2% of episodes occurred within the first 3 months. Eighteen patients (1.5%) received 26 adequate shocks. The inadequate shock rate was low (8 patients, 0.7%). LVEF improved from a median of 28% (IQR 22-32%) before WCD prescription to 35% (IQR 28-42%) during follow-up. Excluding ICD explant patients, 37% of patients received an ICD. CONCLUSIONS: The risk of sudden cardiac death is substantial within the first 3 months after cardiac surgery. Patients were protected effectively by WCD. Due to significant LVEF improvement, the majority did not require ICD implantation after WCD use. Compliance was high despite sternotomy. This multicentre experience confirms existing data regarding effectiveness, safety and compliance. Therefore, WCD should be considered in cardiac surgery patients with severely reduced LVEF.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
6.
Surg Infect (Larchmt) ; 17(5): 552-6, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27281495

RESUMO

BACKGROUND: Reducing surgical site infections (SSI) following median sternotomy remains a challenge for cardiac surgeons. Standard prophylaxis of SSI at our institution includes pre-operative skin disinfection with isopropyl alcohol (IPA). The addition of chlorhexidine gluconate (CHG) has the theoretical advantage of longer antimicrobial activity (>48h), compared with 2 h for IPA alone. OBJECTIVES: This prospective registry study was conducted to evaluate the effect of combined CHG-IPA (ChloraPrep®) skin antiseptic on the incidence of sternal surgical incision infections after cardiac surgical procedures via median sternotomy. METHODS: Between September 2011 and November 2013, 3,942 consecutive patients underwent cardiac surgery with median sternotomy at our institution. Among them, 2,985 patients met inclusion criteria and were enrolled in the study. The complete cohort was prospectively divided into two registries. In registry 1 (1,523 patients), CHG-IPA was used to disinfect skin at the thoracic operative site prior to incision. In registry 2 (1,462 patients), single IPA disinfection was used. The primary endpoint was the incidence of post-sternotomy mediastinitis within 30 d of surgery. Secondary endpoints were SSI of any other kind, 30-d survival, and hospital length of stay. RESULTS: Both registries were well matched in baseline characteristics and main risk factors. Post-operative data analysis revealed reduction in the rate of post-sternotomy mediastinitis in registry 1 (29 patients, 1.9%) versus registry 2 (62 patients, 4.2%), p = 0.0002. No relevant difference in incidence of other surgical site infections, length of hospital stay, and 30-d mortality was found. CONCLUSIONS: Skin disinfection with combined chlorhexidine-isopropyl alcohol reduced the incidence of mediastinitis in elective adult cardiac surgery with median sternotomy but did not affect other types of surgical site infections.


Assuntos
2-Propanol/uso terapêutico , Anti-Infecciosos Locais/uso terapêutico , Clorexidina/uso terapêutico , Mediastinite/epidemiologia , Esternotomia/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Mediastinite/tratamento farmacológico , Mediastinite/prevenção & controle , Pessoa de Meia-Idade , Pele/microbiologia , Infecção da Ferida Cirúrgica/tratamento farmacológico , Infecção da Ferida Cirúrgica/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...