Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Cardiovasc Magn Reson ; 25(1): 78, 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38093273

RESUMO

BACKGROUND: While the microstructure of the left ventricle (LV) has been largely described, only a few studies investigated the right ventricular insertion point (RVIP). It was accepted that the aggregate cardiomyocytes organization was much more complex due to the intersection of the ventricular cavities but a precise structural characterization in the human heart was lacking even if clinical phenotypes related to right ventricular wall stress or arrhythmia were observed in this region. METHODS: MRI-derived anatomical imaging (150 µm3) and diffusion tensor imaging (600 µm3) were performed in large mammalian whole hearts (human: N = 5, sheep: N = 5). Fractional anisotropy, aggregate cardiomyocytes orientations and tractography were compared within both species. Aggregate cardiomyocytes orientation on one ex-vivo sheep whole heart was then computed using structure tensor imaging (STI) from 21 µm isotropic acquisition acquired with micro computed tomography (MicroCT) imaging. Macroscopic and histological examination were performed. Lastly, experimental cardiomyocytes orientation distribution was then compared to the usual rule-based model using electrophysiological (EP) modeling. Electrical activity was modeled with the monodomain formulation. RESULTS: The RVIP at the level of the inferior ventricular septum presented a unique arrangement of aggregate cardiomyocytes. An abrupt, mid-myocardial change in cardiomyocytes orientation was observed, delimiting a triangle-shaped region, present in both sheep and human hearts. FA's histogram distribution (mean ± std: 0.29 ± 0.06) of the identified region as well as the main dimension (22.2 mm ± 5.6 mm) was found homogeneous across samples and species. Averaged volume is 0.34 cm3 ± 0.15 cm3. Both local activation time (LAT) and morphology of pseudo-ECGs were strongly impacted with delayed LAT and change in peak-to-peak amplitude in the simulated wedge model. CONCLUSION: The study was the first to describe the 3D cardiomyocytes architecture of the basal inferoseptal left ventricle region in human hearts and identify the presence of a well-organized aggregate cardiomyocytes arrangement and cardiac structural discontinuities. The results might offer a better appreciation of clinical phenotypes like RVIP-late gadolinium enhancement or uncommon idiopathic ventricular arrhythmias (VA) originating from this region.


Assuntos
Imagem de Tensor de Difusão , Ventrículos do Coração , Humanos , Animais , Ovinos , Ventrículos do Coração/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Meios de Contraste , Microtomografia por Raio-X , Valor Preditivo dos Testes , Gadolínio , Miócitos Cardíacos/fisiologia , Arritmias Cardíacas , Mamíferos
2.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1248-1261, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227351

RESUMO

BACKGROUND: Brugada syndrome is a significant cause of sudden cardiac death (SCD), but the underlying mechanisms remain hypothetical. OBJECTIVES: This study aimed to elucidate this knowledge gap through detailed ex vivo human heart studies. METHODS: A heart was obtained from a 15-year-old adolescent boy with normal electrocardiogram who experienced SCD. Postmortem genotyping was performed, and clinical examinations were done on first-degree relatives. The right ventricle was optically mapped, followed by high-field magnetic resonance imaging and histology. Connexin-43 and NaV1.5 were localized by immunofluorescence, and RNA and protein expression levels were studied. HEK-293 cell surface biotinylation assays were performed to examine NaV1.5 trafficking. RESULTS: A Brugada-related SCD diagnosis was established for the donor because of a SCN5A Brugada-related variant (p.D356N) inherited from his mother, together with a concomitant NKX2.5 variant of unknown significance. Optical mapping demonstrated a localized epicardial region of impaired conduction near the outflow tract, in the absence of repolarization alterations and microstructural defects, leading to conduction blocks and figure-of-8 patterns. NaV1.5 and connexin-43 localizations were normal in this region, consistent with the finding that the p.D356N variant does not affect the trafficking, nor the expression of NaV1.5. Trends of decreased NaV1.5, connexin-43, and desmoglein-2 protein levels were noted; however, the RT-qPCR results suggested that the NKX2-5 variant was unlikely to be involved. CONCLUSIONS: This study demonstrates for the first time that SCD associated with a Brugada-SCN5A variant can be caused by localized functionally, not structurally, impaired conduction.


Assuntos
Síndrome de Brugada , Masculino , Adolescente , Humanos , Células HEK293 , Eletrocardiografia , Doença do Sistema de Condução Cardíaco , Morte Súbita Cardíaca , Conexinas
3.
Diagn Interv Imaging ; 103(12): 607-617, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35961843

RESUMO

PURPOSE: Clinical guidelines recommend the use of bright-blood late gadolinium enhancement (BR-LGE) for the detection and quantification of regional myocardial fibrosis and scar. This technique, however, may suffer from poor contrast at the blood-scar interface, particularly in patients with subendocardial myocardial infarction. The purpose of this study was to assess the clinical performance of a two-dimensional black-blood LGE (BL-LGE) sequence, which combines free-breathing T1-rho-prepared single-shot acquisitions with an advanced non-rigid motion-compensated patch-based reconstruction. MATERIALS AND METHODS: Extended phase graph simulations and phantom experiments were performed to investigate the performance of the motion-correction algorithm and to assess the black-blood properties of the proposed sequence. Fifty-one patients (37 men, 14 women; mean age, 55 ± 15 [SD] years; age range: 19-81 years) with known or suspected cardiac disease prospectively underwent free-breathing T1-rho-prepared BL-LGE imaging with inline non-rigid motion-compensated patch-based reconstruction at 1.5T. Conventional breath-held BR-LGE images were acquired for comparison purposes. Acquisition times were recorded. Two readers graded the image quality and relative contrasts were calculated. Presence, location, and extent of LGE were evaluated. RESULTS: BL-LGE images were acquired with full ventricular coverage in 115 ± 25 (SD) sec (range: 64-160 sec). Image quality was significantly higher on free-breathing BL-LGE imaging than on its breath-held BR-LGE counterpart (3.6 ± 0.7 [SD] [range: 2-4] vs. 3.9 ± 0.2 [SD] [range: 3-4]) (P <0.01) and was graded as diagnostic for 44/51 (86%) patients. The mean scar-to-myocardium and scar-to-blood relative contrasts were significantly higher on BL-LGE images (P < 0.01 for both). The extent of LGE was larger on BL-LGE (median, 5 segments [IQR: 2, 7 segments] vs. median, 4 segments [IQR: 1, 6 segments]) (P < 0.01), the method being particularly sensitive in segments with LGE involving the subendocardium or papillary muscles. In eight patients (16%), BL-LGE could ascertain or rule out a diagnosis otherwise inconclusive on BR-LGE. CONCLUSION: Free-breathing T1-rho-prepared BL-LGE imaging with inline motion compensated reconstruction offers a promising diagnostic technology for the non-invasive assessment of myocardial injuries.


Assuntos
Meios de Contraste , Gadolínio , Masculino , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Gadolínio/química , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Valor Preditivo dos Testes
4.
PLoS One ; 17(7): e0271279, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35849598

RESUMO

BACKGROUND: Knowledge of the normal myocardial-myocyte orientation could theoretically allow the definition of relevant quantitative biomarkers in clinical routine to diagnose heart pathologies. A whole heart diffusion tensor template representative of the global myofiber organization over species is therefore crucial for comparisons across populations. In this study, we developed a groupwise registration and tractography framework to resolve the global myofiber arrangement of large mammalian sheep hearts. To demonstrate the potential application of the proposed method, a novel description of sub-regions in the intraventricular septum is presented. METHODS: Three explanted sheep (ovine) hearts (size ~12×8×6 cm3, heart weight ~ 150 g) were perfused with contrast agent and fixative and imaged in a 9.4T magnet. A group-wise registration of high-resolution anatomical and diffusion-weighted images were performed to generate anatomical and diffusion tensor templates. Diffusion tensor metrics (eigenvalues, eigenvectors, fractional anisotropy …) were computed to provide a quantitative and spatially-resolved analysis of cardiac microstructure. Then tractography was performed using deterministic and probabilistic algorithms and used for different purposes: i) Visualization of myofiber architecture, ii) Segmentation of sub-area depicting the same fiber organization, iii) Seeding and Tract Editing. Finally, dissection was performed to confirm the existence of macroscopic structures identified in the diffusion tensor template. RESULTS: The template creation takes advantage of high-resolution anatomical and diffusion-weighted images obtained at an isotropic resolution of 150 µm and 600 µm respectively, covering ventricles and atria and providing information on the normal myocardial architecture. The diffusion metric distributions from the template were found close to the one of the individual samples validating the registration procedure. Small new sub-regions exhibiting spatially sharp variations in fiber orientation close to the junctions of the septum and ventricles were identified. Each substructure was defined and represented using streamlines. The existence of a fiber-bundles in the posterior junction was validated by anatomical dissection. A complex structural organization of the anterior junction in comparison to the posterior junction was evidenced by the high-resolution acquisition. CONCLUSIONS: A new framework combining cardiac template generation and tractography was applied on the whole sheep heart. The framework can be used for anatomical investigation, characterization of microstructure and visualization of myofiber orientation across samples. Finally, a novel description of the ventricular junction in large mammalian sheep hearts was proposed.


Assuntos
Imagem de Tensor de Difusão , Imageamento Tridimensional , Animais , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Mamíferos , Miócitos Cardíacos , Ovinos
5.
Am J Physiol Heart Circ Physiol ; 322(6): H936-H952, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35302879

RESUMO

Cardiac fiber direction is an important factor determining the propagation of electrical activity, as well as the development of mechanical force. In this article, we imaged the ventricles of several species with special attention to the intraventricular septum to determine the functional consequences of septal fiber organization. First, we identified a dual-layer organization of the fiber orientation in the intraventricular septum of ex vivo sheep hearts using diffusion tensor imaging at high field MRI. To expand the scope of the results, we investigated the presence of a similar fiber organization in five mammalian species (rat, canine, pig, sheep, and human) and highlighted the continuity of the layer with the moderator band in large mammalian species. We implemented the measured septal fiber fields in three-dimensional electromechanical computer models to assess the impact of the fiber orientation. The downward fibers produced a diamond activation pattern superficially in the right ventricle. Electromechanically, there was very little change in pressure volume loops although the stress distribution was altered. In conclusion, we clarified that the right ventricular septum has a downwardly directed superficial layer in larger mammalian species, which can have modest effects on stress distribution.NEW & NOTEWORTHY A dual-layer organization of the fiber orientation in the intraventricular septum was identified in ex vivo hearts of large mammals. The RV septum has a downwardly directed superficial layer that is continuous with the moderator band. Electrically, it produced a diamond activation pattern. Electromechanically, little change in pressure volume loops were noticed but stress distribution was altered. Fiber distribution derived from diffusion tensor imaging should be considered for an accurate strain and stress analysis.


Assuntos
Imagem de Tensor de Difusão , Septo Interventricular , Animais , Diamante , Cães , Ventrículos do Coração , Mamíferos , Miocárdio , Ratos , Ovinos , Suínos , Septo Interventricular/diagnóstico por imagem
6.
MAGMA ; 34(5): 741-755, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33638739

RESUMO

OBJECTIVE: The aim of the study is to compare structure tensor imaging (STI) with diffusion tensor imaging (DTI) of the sheep heart (approximately the same size as the human heart). MATERIALS AND METHODS: MRI acquisition on three sheep ex vivo hearts was performed at 9.4 T/30 cm with a seven-element RF coil. 3D FLASH with an isotropic resolution of 150 µm and 3D spin-echo DTI at 600 µm were performed. Tensor analysis, angles extraction and segments divisions were performed on both volumes. RESULTS: A 3D FLASH allows for visualization of the detailed structure of the left and right ventricles. The helix angle determined using DTI and STI exhibited a smooth transmural change from the endocardium to the epicardium. Both the helix and transverse angles were similar between techniques. Sheetlet organization exhibited the same pattern in both acquisitions, but local angle differences were seen and identified in 17 segments representation. DISCUSSION: This study demonstrated the feasibility of high-resolution MRI for studying the myocyte and myolaminar architecture of sheep hearts. We presented the results of STI on three whole sheep ex vivo hearts and demonstrated a good correspondence between DTI and STI.


Assuntos
Imagem de Tensor de Difusão , Coração , Animais , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ovinos
7.
MAGMA ; 34(4): 605-618, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33484367

RESUMO

OBJECTIVES: We investigate the possibility to exploit high-field MRI to acquire 3D images of Purkinje network which plays a crucial role in cardiac function. Since Purkinje fibers (PF) have a distinct cellular structure and are surrounded by connective tissue, we investigated conventional contrast mechanisms along with the magnetization transfer (MT) imaging technique to improve image contrast between ventricular structures of differing macromolecular content. METHODS: Three fixed porcine ventricular samples were used with free-running PFs on the endocardium. T1, T2*, T2, and M0 were evaluated on 2D slices for each sample at 9.4 T. MT parameters were optimized using hard pulses with different amplitudes, offset frequencies and durations. The cardiac structure was assessed through 2D and 3D T1w images with isotropic resolutions of 150 µm. Histology, immunofluorescence, and qPCR were performed to analyze collagen contents of cardiac tissue and PF. RESULTS: An MT preparation module of 350 ms duration inserted into the sequence with a B1 = 10 µT and frequency offset = 3000 Hz showed the best contrast, approximately 0.4 between PFs and myocardium. Magnetization transfer ratio (MTR) appeared higher in the cardiac tissue (MTR = 44.7 ± 3.5%) than in the PFs (MTR = 25.2 ± 6.3%). DISCUSSION: MT significantly improves contrast between PFs and ventricular myocardium and appears promising for imaging the 3D architecture of the Purkinje network.


Assuntos
Imageamento por Ressonância Magnética , Ramos Subendocárdicos , Animais , Imageamento Tridimensional , Ramos Subendocárdicos/diagnóstico por imagem , Suínos
8.
Int J Cardiovasc Imaging ; 36(3): 385-394, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31745743

RESUMO

The healing process, occurring after intra-cardiac and intra-vascular device implantation, starts with fibrin condensation and attraction of inflammatory cells, followed by the formation of fibrous tissue that slowly covers the device. The duration of this process is variable and may be incomplete, which can lead to thrombus formation, dislodgement of the device or stenosis. To better understand this process and the neotissue formation, animal models were developed: small (rats and rabbits) and large (sheep, pigs, dogs and baboons) animal models for intra-vascular device implantation; sheep and pigs for intra-cardiac device implantation. After intra-vascular and intra-cardiac device implantation in these animal models, in vitro techniques, i.e. histology, which is the gold standard and scanning electron microscopy, were used to assess the device coverage, characterize the cell constitution and detect complications such as thrombosis. In humans, optical coherence tomography and intra-vascular ultrasounds are both invasive modalities used after stent implantation to assess the structure of the vessels, atheroma plaque and complications. Non-invasive techniques (computed tomography and magnetic resonance imaging) are in development in humans and animal models for tissue characterization (fibrosis), device remodeling evaluation and device implantation complications (thrombosis and stenosis). This review aims to (1) present the experimental models used to study this process on cardiac devices; (2) focus on the in vitro techniques and invasive modalities used currently in humans for intra-vascular and intra-cardiac devices and (3) assess the future developments of non-invasive techniques in animal models and humans for intra-cardiac devices.


Assuntos
Vasos Sanguíneos/patologia , Desfibriladores Implantáveis , Procedimentos Endovasculares/instrumentação , Miocárdio/patologia , Marca-Passo Artificial , Intervenção Coronária Percutânea/instrumentação , Implantação de Prótese/instrumentação , Stents , Cicatrização , Animais , Biópsia , Vasos Sanguíneos/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Fibrose , Humanos , Modelos Animais , Intervenção Coronária Percutânea/efeitos adversos , Implantação de Prótese/efeitos adversos , Fatores de Risco , Fatores de Tempo
9.
Circ Arrhythm Electrophysiol ; 12(9): e007158, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31446771

RESUMO

BACKGROUND: Multipolar catheters are increasingly used for high-density mapping. However, the threshold to define scar areas has not been well described for each configuration. We sought to elucidate the impact of bipolar spacing and orientation on the optimal threshold to match magnetic resonance imaging-defined scar. METHOD: The HD-Grid catheter uniquely allows for different spatially stable bipolar configurations to be tested. We analyzed the electrograms with settings of HD-16 (3 mm spacing in both along and across bipoles) and HD-32 (1 mm spacing in along bipoles and 3 mm spacing in across bipoles) and determined the optimal cutoff for scar detection in 6 infarcted sheep. RESULTS: From 456 total acquisition sites (mean 76±12 per case), 14 750 points with the HD-16 and 32286 points with the HD-32 configuration for bipolar electrograms were analyzed. For bipolar voltages, the optimal cutoff value to detect the magnetic resonance imaging-defined scar based on the Youden's Index, and the area under the receiver operating characteristic curve (AUROC) differed depending on the spacing and orientation of bipoles; across 0.84 mV (AUROC, 0.920; 95% CI, 0.911-0.928), along 0.76 mV (AUROC, 0.903; 95% CI, 0.893-0.912), north-east direction 0.95 mV (AUROC, 0.923; 95% CI, 0.913-0.932), and south-east direction, 0.87 mV (AUROC, 0.906; 95% CI, 0.895-0.917) in HD-16; and across 0.83 mV (AUROC, 0.917; 95% CI, 0.911-0.924), along 0.46 mV (AUROC, 0.890; 95% CI, 0.883-0.897), north-east direction 0.89 mV (AUROC, 0.923; 95% CI, 0.917-0.929), and south-east direction 0.83 mV (AUROC, 0.913; 95% CI, 0.906-0.920) in HD-32. Significant differences in AUROC were seen between HD-16 along versus across (P=0.002), HD-16 north-east direction versus south-east direction (P=0.01), HD-32 north-east direction versus south-east direction (P<0.0001), and HD-16 along versus HD-32 along (P=0.006). The AUROC was significantly larger (P<0.01) when only the best points on each given site were selected for analysis, compared with when all points were used. CONCLUSIONS: Spacing and orientation of bipoles impacts the accuracy of scar detection. Optimal threshold specific to each bipolar configuration should be determined. Selecting one best voltage point among multiple points projected on the same surface is also critical on the Ensite-system to increase the accuracy of scar-mapping.


Assuntos
Mapeamento Potencial de Superfície Corporal/instrumentação , Catéteres , Cicatriz/patologia , Sistema de Condução Cardíaco/fisiopatologia , Miocárdio/patologia , Taquicardia Ventricular/diagnóstico , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Imagem Cinética por Ressonância Magnética , Ovinos , Taquicardia Ventricular/fisiopatologia
10.
JACC Clin Electrophysiol ; 5(1): 66-77, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30678788

RESUMO

OBJECTIVES: This study sought to evaluate the relation between bipolar electrode spacing and far- and near-field electrograms. BACKGROUND: The detailed effects of bipolar spacing on electrograms (EGMs) is not well described. METHODS: With a HD-Grid catheter, EGMs from different bipole pairs could be created in each acquisition. This study analyzed the effect of bipolar spacing on EGMs in 7 infarcted sheep. A segment was defined as a 2-mm center-to-center bipole. In total, 4,768 segments (2,020 healthy, 1,542 scar, and 1,206 in border areas, as defined by magnetic resonance imaging [MRI]) were covered with an electrode pair of spacing of 2 mm (Bi-2), 4 mm (Bi-4), and 8 mm (Bi-8). RESULTS: A total of 3,591 segments in Bi-2 were free from local abnormal ventricular activities (LAVAs); 1,630 segments were within the MRI-defined scar and/or border area. Among them, 172 (10.6%) segments in Bi-4 and 219 (13.4%) segments in Bi-8 showed LAVAs. In contrast, LAVAs were identified in 1,177 segments in Bi-2; 1,118 segments were within the MRI-defined scar and/or border area. Among them, LAVAs were missed in 161 (14.4%) segments in Bi-4 and in 409 (36.6%) segments in Bi-8. In segments with LAVAs, median far-field voltage increased from 0.09 mV (25th to 75th percentile: 0.06 to 0.14 mV) in Bi-2, to 0.16 mV (25th to 75th percentile: 0.10 to 0.24 mV) in Bi-4, and to 0.28 mV (25th to 75th percentile: 0.20 to 0.42 mV) in Bi-8 (p < 0.0001). Median near-field voltage increased from 0.14 mV (25th to 75th percentile: 0.08 to 0.25 mV) in Bi-2, to 0.21 mV (25th to 75th percentile: 0.12 to 0.35 mV) in Bi-4, and to 0.32 mV (25th to 75th percentile: 0.17 to 0.48 mV) in Bi-8 (p < 0.0001). The median near-/far-field voltage ratio decreased from 1.67 in Bi-2, to 1.43 in Bi-4, and 1.23 in Bi-8 (p < 0.0001). CONCLUSIONS: Closer spacing better discriminates surviving tissue from dead scar area. Although far-field voltage systematically increases with spacing, near-field voltages were more variable, depending on local surviving muscular bundles. Near-field EGMs are more easily observed with smaller spacing, largely due to the reduction of the far-field effect.


Assuntos
Eletrocardiografia , Mapeamento Epicárdico , Animais , Cateteres Cardíacos , Cicatriz/diagnóstico por imagem , Cicatriz/fisiopatologia , Modelos Animais de Doenças , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrodos , Mapeamento Epicárdico/instrumentação , Mapeamento Epicárdico/métodos , Desenho de Equipamento , Feminino , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Ovinos
11.
Heart Rhythm ; 15(12): 1853-1861, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30026016

RESUMO

BACKGROUND: The direct effect of bipolar orientation on electrograms (EGMs) remains unknown. OBJECTIVE: The purpose of this study was to examine the variation of EGMs with diagonally orthogonal bipoles. METHODS: The HD-32 Grid catheter (Abbott, Minneapolis, MN) can assess the effect of bipolar orientation while keeping the interelectrode distance and center unchanged. Seven sheep with anterior myocardial infarction were analyzed using diagonally orthogonal electrode pairs across splines by comparing local EGMs from each pair of opposing electrodes {eg. A1-B3 (southeast direction [SE]) vs A3-B1 (northeast direction [NE])}. RESULTS: A total of 4084 EGMs (1 in each direction) were analyzed for 2042 sites (544 in the infarcted area, 488 in the border area, and 1010 in the normal area). The higher and lower voltages measured using each pair of opposing electrodes significantly differed (1.10 mV [0.43-2.56 mV] vs 0.69 mV [0.28-1.58 mV]; P < .0001), and the median variation was 0.28 mV (0.11-0.80 mV) (31.7% [16.0%-48.9%]). The voltage variation was maximized to 48.7% (37.7%-61.6%) (P < .0001) on sites where the activation wavefront was perpendicular to the one bipolar direction and parallel to the other. A total of 594 of 719 (82.6%) sites with the voltage <0.5 mV and 539 of 699 (77.1%) sites with the voltage >1.5 mV in NE stayed in the same voltage range as those in SE. However, only 348 of 624 (55.8%) sites with the voltage 0.5-1.5 mV in NE stayed in the same range as those in SE. Local ventricular abnormal activities (LAVAs) were detected in 592 of 2042 (29.0%) sites in total, frequently distributed in the border area. A total of 177 (29.9%) LAVAs were missed in one direction and 180 (30.4%) in the other. When 415 (70.1%) LAVAs detected in NE are defined as the reference, 235 of 415 (56.6%) matched with those detected in SE. CONCLUSION: The bipolar voltage and distribution of LAVAs may differ significantly between diagonally orthogonal bipolar pairs at any given site.


Assuntos
Mapeamento Potencial de Superfície Corporal/instrumentação , Terapia de Ressincronização Cardíaca/métodos , Eletrodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/diagnóstico , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Imageamento Tridimensional , Ovinos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia
12.
Respir Res ; 18(1): 47, 2017 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-28288643

RESUMO

Pulmonary arterial hypertension (PAH) is a severe form of pulmonary hypertension that combines multiple alterations of pulmonary arteries, including, in particular, thrombotic and plexiform lesions. Multiple-pathological-insult animal models, developed to more closely mimic this human severe PAH form, often require complex and/or long experimental procedures while not displaying the entire panel of characteristic lesions observed in the human disease. In this study, we further characterized a rat model of severe PAH generated by combining a single injection of monocrotaline with 4 weeks exposure to chronic hypoxia. This model displays increased pulmonary arterial pressure, right heart altered function and remodeling, pulmonary arterial inflammation, hyperresponsiveness and remodeling. In particular, severe pulmonary arteriopathy was observed, with thrombotic, neointimal and plexiform-like lesions similar to those observed in human severe PAH. This model, based on the combination of two conventional procedures, may therefore be valuable to further understand the pathophysiology of severe PAH and identify new potential therapeutic targets in this disease.


Assuntos
Modelos Animais de Doenças , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Hipóxia/complicações , Hipóxia/fisiopatologia , Artéria Pulmonar/fisiopatologia , Animais , Pressão Arterial , Doença Crônica , Humanos , Masculino , Monocrotalina , Artéria Pulmonar/efeitos dos fármacos , Ratos , Ratos Wistar , Índice de Gravidade de Doença , Resistência Vascular/efeitos dos fármacos
13.
Europace ; 19(3): 458-464, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26896467

RESUMO

AIMS: Interventional cardiac catheter mapping is routinely guided by X-ray fluoroscopy, although radiation exposure remains a significant concern. Feasibility of catheter ablation for common flutter has recently been demonstrated under magnetic resonance imaging (MRI) guidance. The benefit of catheter ablation under MRI could be significant for complex arrhythmias such as atrial fibrillation (AF), but MRI-compatible multi-electrode catheters such as Lasso have not yet been developed. This study aimed at demonstrating the feasibility and safety of using a multi-electrode catheter [magnetic resonance (MR)-compatible Lasso] during MRI for cardiac mapping. We also aimed at measuring the level of interference between MR and electrophysiological (EP) systems. METHODS AND RESULTS: Experiments were performed in vivo in sheep (N = 5) using a multi-electrode, circular, steerable, MR-compatible diagnostic catheter. The most common MRI sequences (1.5T) relevant for cardiac examination were run with the catheter positioned in the right atrium. High-quality electrograms were recorded while imaging with a maximal signal-to-noise ratio (peak-to-peak signal amplitude/peak-to-peak noise amplitude) ranging from 5.8 to 165. Importantly, MRI image quality was unchanged. Artefacts induced by MRI sequences during mapping were demonstrated to be compatible with clinical use. Phantom data demonstrated that this 10-pole circular catheter can be used safely with a maximum of 4°C increase in temperature. CONCLUSIONS: This new MR-compatible 10-pole catheter appears to be safe and effective. Combining MR and multipolar EP in a single session offers the possibility to correlate substrate information (scar, fibrosis) and EP mapping as well as online monitoring of lesion formation and electrical endpoint.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Imageamento por Ressonância Magnética , Animais , Artefatos , Cateterismo Cardíaco/efeitos adversos , Cateteres Cardíacos/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Estudos de Viabilidade , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Teste de Materiais , Modelos Animais , Imagens de Fantasmas , Valor Preditivo dos Testes , Carneiro Doméstico , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
14.
PLoS One ; 11(9): e0162677, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27622548

RESUMO

INTRODUCTION: Gradual alterations in cardiac energy balance, as assessed by the myocardial PCr/ATP-ratio, are frequently associated with the development of cardiac disease. Despite great interest for the follow-up of myocardial PCr and ATP content, cardiac MR-spectroscopy in rat models in vivo is challenged by sensitivity issues and cross-contamination from other organs. METHODS: Here we combined MR-Imaging and MR-Spectroscopy (Bruker BioSpec 9.4T) to follow-up for the first time in vivo the cardiac energy balance in the SHR, a genetic rat model of cardiac hypertrophy known to develop early disturbances in cytosolic calcium dynamics. RESULTS: We obtained consistent 31P-spectra with high signal/noise ratio from the left ventricle in vivo by using a double-tuned (31P/1H) surface coil. Reasonable acquisition time (<3.2min) allowed assessing the PCr/ATP-ratio comparatively in SHR and age-matched control rats (WKY): i) weekly from 12 to 21 weeks of age; ii) in response to a bolus injection of the ß-adrenoreceptor agonist isoproterenol at age 21 weeks. DISCUSSION: Along weeks, the cardiac PCr/ATP-ratio was highly reproducible, steady and similar (2.35±0.06) in SHR and WKY, in spite of detectable ventricular hypertrophy in SHR. At the age 21 weeks, PCr/ATP dropped more markedly (-17.1%±0.8% vs. -3,5%±1.4%, P<0.001) after isoproterenol injection in SHR and recovered slowly thereafter (time constant 21.2min vs. 6.6min, P<0.05) despite similar profiles of tachycardia among rats. CONCLUSION: The exacerbated PCr/ATP drop under ß-adrenergic stimulation indicates a defect in cardiac energy regulation possibly due to calcium-mediated abnormalities in the SHR heart. Of note, defects in energy regulation were present before detectable abnormalities in cardiac energy balance at rest.


Assuntos
Metabolismo Energético , Hipertensão/metabolismo , Miocárdio/metabolismo , Trifosfato de Adenosina/metabolismo , Agonistas Adrenérgicos beta/administração & dosagem , Animais , Metabolismo Energético/efeitos dos fármacos , Seguimentos , Coração/efeitos dos fármacos , Hipertensão/diagnóstico por imagem , Hipertensão/tratamento farmacológico , Isoproterenol/administração & dosagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/métodos , Masculino , Fosfocreatina/metabolismo , Fósforo/metabolismo , Ratos , Ratos Endogâmicos SHR , Ratos Endogâmicos WKY
16.
Basic Res Cardiol ; 111(4): 46, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27287250

RESUMO

Transgenic and gene knockout rodent models are primordial to study pathophysiological processes in cardiovascular research. Over time, cardiac MRI has become a gold standard for in vivo evaluation of such models. Technical advances have led to the development of magnets with increasingly high field strength, allowing specific investigation of cardiac anatomy, global and regional function, viability, perfusion or vascular parameters. The aim of this report is to provide a review of the various sequences and techniques available to image mice on 7-11.7 T magnets and relevant to the clinical setting in humans. Specific technical aspects due to the rise of the magnetic field are also discussed.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Modelos Animais de Doenças , Humanos , Camundongos
17.
Am J Physiol Heart Circ Physiol ; 310(10): H1371-80, 2016 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-26968545

RESUMO

To provide a model close to the human heart, and to study intrinsic cardiac function at the same time as electromechanical coupling, we developed a magnetic resonance (MR)-compatible setup of isolated working perfused pig hearts. Hearts from pigs (40 kg, n = 20) and sheep (n = 1) were blood perfused ex vivo in the working mode with and without loaded right ventricle (RV), for 80 min. Cardiac function was assessed by measuring left intraventricular pressure and left ventricular (LV) ejection fraction (LVEF), aortic and mitral valve dynamics, and native T1 mapping with MR imaging (1.5 Tesla). Potential myocardial alterations were assessed at the end of ex vivo perfusion from late-Gadolinium enhancement T1 mapping. The ex vivo cardiac function was stable across the 80 min of perfusion. Aortic flow and LV-dP/dtmin were significantly higher (P < 0.05) in hearts perfused with loaded RV, without differences for heart rate, maximal and minimal LV pressure, LV-dP/dtmax, LVEF, and kinetics of aortic and mitral valves. T1 mapping analysis showed a spatially homogeneous distribution over the LV. Simultaneous recording of hemodynamics, LVEF, and local cardiac electrophysiological signals were then successfully performed at baseline and during electrical pacing protocols without inducing alteration of MR images. Finally, (31)P nuclear MR spectroscopy (9.4 T) was also performed in two pig hearts, showing phosphocreatine-to-ATP ratio in accordance with data previously reported in vivo. We demonstrate the feasibility to perfuse isolated pig hearts in the working mode, inside an MR environment, allowing simultaneous assessment of cardiac structure, mechanics, and electrophysiology, illustrating examples of potential applications.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Metabolismo Energético , Coração/fisiologia , Hemodinâmica , Preparação de Coração Isolado/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/metabolismo , Perfusão , Potenciais de Ação , Trifosfato de Adenosina/metabolismo , Animais , Pressão Arterial , Estudos de Viabilidade , Frequência Cardíaca , Cinética , Fosfocreatina/metabolismo , Carneiro Doméstico , Volume Sistólico , Sus scrofa , Função Ventricular Esquerda , Função Ventricular Direita , Pressão Ventricular
18.
Front Pharmacol ; 7: 506, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28066252

RESUMO

In recent clinical studies, vascular disrupting agents (VDAs) are mainly used in combination with chemotherapy. However, an often overlooked concern in treatment combination is the VDA-induced impairment of chemotherapy distribution in the tumor. The work presented here investigated the impact of blood flow shutdown induced by Combretastatin A4 (CA4) on gemcitabine uptake into mouse hepatocarcinoma. At 2 h after CA4 treatment, using DCE-MRI, a significant decrease in the perfusion-relevant parameters Ktrans and Vp were observed in treated group compared with the control group. The blood flow shutdown was indeed confirmed by a histology study. In a third experiment, the total gemcitabine uptake was found to be significantly lower in treated tumors, as assessed in a separate experiment using ex vivo fluorine nuclear magnetic resonance spectroscopy. The amount of active metabolite gemcitabine triphosphate was also lower in treated tumors. In conclusion, the blood flow shutdown induced by VDAs can impact negatively on the delivery of small cytotoxic agents in tumors. The present study outlines the importance of monitoring the tumor vascular function when designing drug combinations.

19.
Magn Reson Imaging ; 34(2): 105-13, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26523659

RESUMO

Availability of an innocuous and repeatable technique for monitoring tumor oxygenation throughout therapeutic course should be a key factor for adaptative therapeutic strategies. We previously qualified lipids R1 as a marker of oxygen level on experimental tumor models. The objectives of the present study were to assess the applicability of measuring lipids R1 in primary central nervous system malignancies in a clinical setting as well as to compare lipids R1 with global (water+lipids) R1 and R2* which are also sensitive to the oxygen environment. 25 patients with brain neuroepithelial tumors were examined on a clinical 3T MR system. Values obtained within regions of interest contouring contrast-enhanced tumor (C+), unenhanced tumor (C-), peritumoral edema, and normal appearing white matter (NAWM) were compared to those obtained for the normal brain parenchyma of 17 healthy volunteers. Global R1 and lipids R1 values were significantly lower in tumors than in NAWM of patients or healthy brain of normal volunteers. In contrast, R2* values were not significantly different in tumors compared to NAWM or healthy brains. None of them showed significant difference between C+ and C- tumors. Global R1 values within NAWM were significantly different from that of both tumor and peritumoral edema, but lacked sensitivity to differentiate between tumor and peritumoral edema. In turn, lipids R1 measurements enabled discrimination between tumor areas and peritumoral edema. In conclusion, global R1 and lipids R1 deserve further attention as potential markers of tumor hypoxia in primary brain tumors.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/metabolismo , Metabolismo dos Lipídeos , Imageamento por Ressonância Magnética/métodos , Neoplasias Neuroepiteliomatosas/metabolismo , Oxigênio/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias Encefálicas/diagnóstico , Hipóxia Celular , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Neoplasias Neuroepiteliomatosas/diagnóstico , Oximetria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Magn Reson Med ; 75(2): 866-72, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25765253

RESUMO

PURPOSE: To benchmark MOBILE (Mapping of Oxygen By Imaging Lipid relaxation Enhancement), a recent noninvasive MR method of mapping changes in tumor hypoxia, electron paramagnetic resonance (EPR) oximetry, and dynamic contrast-enhanced MRI (DCE-MRI) as biomarkers of changes in tumor hemodynamics induced by the antivascular agent combretastatin A4 (CA4). METHODS: NT2 and MDA-MB-231 mammary tumors were implanted subcutaneously in FVB/N and nude NMRI mice. Mice received 100 mg/kg of CA4 intraperitoneally 3 hr before imaging. The MOBILE sequence (assessing R1 of lipids) and the DCE sequence (assessing K(trans) hemodynamic parameter), were assessed on different cohorts. pO2 changes were confirmed on matching tumors using EPR oximetry consecutive to the MOBILE sequence. Changes in tumor vasculature were assessed using immunohistology consecutive to DCE-MRI studies. RESULTS: Administration of CA4 induced a significant decrease in lipids R1 (P = 0.0273) on pooled tumor models and a reduction in tumor pO2 measured by EPR oximetry. DCE-MRI also exhibited a significant drop of K(trans) (P < 0.01) that was confirmed by immunohistology. CONCLUSION: MOBILE was identified as a marker to follow a decrease in oxygenation induced by CA4. However, DCE-MRI showed a higher dynamic range to follow changes in tumor hemodynamics induced by CA4.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Hemodinâmica/efeitos dos fármacos , Imageamento por Ressonância Magnética/métodos , Neoplasias Mamárias Experimentais/metabolismo , Oximetria/métodos , Oxigênio/metabolismo , Estilbenos/farmacologia , Animais , Biomarcadores Tumorais/metabolismo , Meios de Contraste , Feminino , Camundongos , Camundongos Nus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...