Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Arch Cardiovasc Dis ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38670870

RESUMO

BACKGROUND: With the development of advanced sequencing techniques, genetic testing has emerged as a valuable tool for the work-up of non-ischaemic sudden cardiac arrest (SCA). AIMS: To evaluate the effectiveness of genetic testing in patients with unexplained SCA, according to clinical phenotype. METHODS: All patients who underwent molecular genetic testing for non-ischaemic SCA with no left ventricular cardiomyopathy between 2012 and 2021 in two French university hospitals were included. RESULTS: Of 66 patients (mean age 36.7±11.9years, 54.5% men), 21 (31.8%; 95% confidence interval 22.4-45.3%) carried a genetic variant: eight (12.1%) had a pathogenic or likely pathogenic (P/LP) variant and 13 (19.7%) had a variant of uncertain significance (VUS). Among 37 patients (56.1%) with no phenotypic clues, genetic testing identified a P/LP variant in five (13.5%), mainly in RYR2 (n=3) and SCN5A (n=2), and a VUS in nine (24.3%). None of the nine patients with phenotypic evidence of channelopathies had P/LP variants, but two had VUS in RYR2 and NKX2.5. Among the 20 patients with suspected arrhythmogenic cardiomyopathy, three P/LP variants (15.0%) and two VUS (10.0%) were found in DSC2, PKP2, SCN5A and DSG2, TRPM4, respectively. Genetic testing was performed sooner after cardiac arrest (P<0.001) and results were obtained more rapidly (P=0.02) after versus before 2016. CONCLUSION: This study highlights the utility of molecular genetic testing with a genetic variant of interest identified in one-third of patients with unexplained SCA. Genetic testing was beneficial even in patients without phenotypic clues, with one-fourth of patients carrying a P/LP variant that could have direct implications.

2.
J Interv Card Electrophysiol ; 66(4): 931-940, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36251129

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation (PVI) has become the cornerstone of atrial fibrillation (AF) ablation in patients with paroxysmal AF (PAF). PVI durability is influenced by many factors including PVs anatomy. Data regarding the influence of PVs anatomical variations on the outcomes of PAF ablation in the era of contact force-sensing ablation catheters are scarce and contradictory. METHODS: Consecutive patients referred to our center for a first ablation of PAF using radiofrequency (RF) were included. PVs anatomy was classified into 3 groups: typical anatomy (4 distinct veins), left common ostium (LCO), and right accessory PV (RAPV). The primary outcome was recurrence of atrial arrhythmia episode during a 12-month follow-up after ablation. RESULTS: Two hundred twenty-three patients were included (mean age 58.4 ± 10.8 years and 70.9% male). Among this cohort, 141 patients (63.2%) had typical PV anatomy, 53 (23.8%) had a LCO, and 29 (13.0%) had a RAPV. The existence of a RAPV was not associated with a higher rate of AF recurrences (22 (14.3%) vs. 7 (10.1%), p = 0.519). After multivariate analysis, the presence of an LCO did not appear to be associated with the AF recurrence rate at 12 months (OR = 1.69, 95%CI 0.95-2.49, p = 0.098). Maintenance of antiarrhythmic drugs after ablation was the only factor independently associated with a decreased risk of AF recurrence at 12 months (OR = 0.76, 95%CI 0.60-0.97, p = 0.046). CONCLUSION: This study suggests that the presence of an LCO or a RAPV is not associated with a higher rate of AF recurrence at 12 months after radiofrequency PVI using contact force-sensing catheters in PAF patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Recidiva
3.
J Cardiovasc Electrophysiol ; 33(8): 1801-1809, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35665562

RESUMO

We aim to describe the technical aspects of pace mapping (PM), as well as the two typical patterns of pacing correlation maps during ventricular tachycardia (VT) ablation. The first main pattern is focal, with a gradual and eccentric decrease of the QRS correlation from the area with the best PM correlation. This focal pattern may be associated with two clinical situations: (1) with some endocardial points showing a good correlation compared to VT morphology: true endocardial exit of VT or endocardial breakthrough of either an intramural or an epicardial circuit; (2) without any endocardial points showing a good correlation compared to VT morphology: the VT may originate from the other ventricle, but the presence of an intramural or an epicardial circuit should be considered in patients with a structural heart disease. The second pattern is the presence of PM points exhibiting a good correlation close to other PM points showing a poor correlation compared to VT morphology: this abrupt change in paced QRS morphology over a short distance indicates divergence of activation wavefronts between these sites and suggests the presence of a slow conduction channel: the VT isthmus.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Endocárdio/cirurgia , Frequência Cardíaca , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
4.
J Cardiovasc Dev Dis ; 8(12)2021 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-34940538

RESUMO

Laser balloon (LB) has emerged as an interesting strategy for pulmonary vein isolation in paroxysmal atrial fibrillation (AF). A third-generation LB has recently been developed, allowing a continuous ablation set. We aimed to compare the results from our center's experience with second and third-generation LBs to a cohort of matched patients who had undergone radiofrequency ablation (RFA) with contact-force catheters. This retrospective monocenter case-control study included our first 50 LB paroxysmal AF ablations (26 second and 24 third-generation LB) and 50 RFA controls, matched on age, sex and left atrial dilation. The two groups had similar baseline parameters. LB procedures were significantly shorter than RFA (129 (110-160) vs. 160 (119-198) min, p = 0.007). During AF ablation, two major complications occurred in each group. At the one-year follow-up, AF recurrence was diagnosed in 7 (14%) of the LB group vs. 14 (28%) of the RFA group (p = 0.14). Moreover, we observed that third-generation LB procedures were associated with shorter laser applications (22 (19-29) vs. 69 (55-76) min, p < 0.001) and procedural durations (111 (100-128) vs. 151.5 (128.5-167) min, p < 0.001) compared to second-generation LB procedures. In the context of the major increase in the number of AF ablations, LB demonstrated consistent results in terms of clinical success, complications and also reduced procedure durations compared to RFA.

5.
J Clin Med ; 10(18)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34575348

RESUMO

BACKGROUND: Activated Clotting Time (ACT) guided heparinization is the gold standard for titrating unfractionated heparin (UFH) administration during atrial fibrillation (AF) ablation procedures. The current ACT target (300 s) is based on studies in patients receiving a vitamin K antagonist (VKA). Several studies have shown that in patients receiving Direct Oral Anticoagulants (DOACs), the correlation between ACT values and UFH delivered dose is weak. OBJECTIVE: To assess the relationship between ACT and real heparin anticoagulant effect measured by anti-Xa activity in patients receiving different anticoagulant treatments. METHODS: Patients referred for AF catheter ablation in our centre were prospectively included depending on their anticoagulant type. RESULTS: 113 patients were included, receiving rivaroxaban (n = 30), apixaban (n = 30), dabigatran (n = 30), and VKA (n = 23). To meet target ACT, a higher UFH dose was required in DOAC than VKA patients (14,077.8 IU vs. 9565.2 IU, p < 0.001), leading to a longer time to achieve target ACT (46.5 min vs. 27.3 min, p = 0.001). The correlation of ACT and anti-Xa activity was tighter in the VKA group (Spearman correlation ρ = 0.53), compared to the DOAC group (ρ = 0.19). Despite lower ACT values in the DOAC group, this group demonstrated a higher mean anti-Xa activity compared to the VKA group (1.56 ± 0.39 vs. 1.14 ± 0.36; p = 0.002). CONCLUSION: Use of a conventional ACT threshold at 300 s during AF ablation procedures leads to a significant increase in UFH administration in patients treated with DOACs. This increase corresponds more likely to an overdosing than a real increase in UFH requirement.

7.
J Clin Med ; 10(14)2021 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-34300203

RESUMO

BACKGROUND: In patients undergoing paroxysmal atrial fibrillation (PAF) ablation, pulmonary vein isolation (PVI) alone fails in maintaining sinus rhythm in up to one third of patients after a first catheter ablation. Epicardial adipose tissue (EAT), as an endocrine-active organ, could play a role in the recurrence of AF after catheter ablation. OBJECTIVE: To evaluate the predictive value of clinical, echocardiographic, biological parameters and epicardial fat density measured by computed tomography scan (CT-scan) on AF recurrence in PAF patients who underwent a first pulmonary vein isolation procedure using radiofrequency (RF). METHODS: This monocentric retrospective study included all patients undergoing first-time RF PAF ablation at the Nancy University Hospital between March 2015 and December 2018 with one-year follow-up. RESULTS: 389 patients were included, of whom 128 (32.9%) had AF recurrence at one-year follow-up. Neither total-EAT volume (88.6 ± 37.2 cm3 vs. 91.4 ± 40.5 cm3, p = 0.519), nor total-EAT radiodensity (-98.8 ± 4.1 HU vs. -98.8 ± 3.8 HU, p = 0.892) and left atrium-EAT radiodensity (-93.7 ± 4.3 HU vs. -93.4 ± 6.0 HU, p = 0.556) were significantly associated with AF recurrence after PAF ablation. In multivariate analysis, previous cavo-tricuspid isthmus (CTI) ablation, ablation procedure duration, BNP and triglyceride levels remained independently associated with AF recurrence after catheter ablation at 12-months follow-up. CONCLUSION: Contrary to persistent AF, EAT parameters are not associated with AF recurrence after paroxysmal AF ablation. Thus, the role of the metabolic atrial substrate in PAF pathophysiology appears less obvious than in persistent AF.

8.
Europace ; 22(1): 109-116, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31909432

RESUMO

AIMS: Our study assesses the value of electrograms (EGMs) characteristics to identify a ventricular tachycardia (VT) isthmus entrance in patients with post-infarct VT. Post-infarct VTs are mostly due to a re-entrant circuit. A pacemapping (PM) approach is able to localize the VT isthmus during sinus rhythm. Limited data are available about the role of local EGMs in defining VT isthmus location. METHODS AND RESULTS: Twenty consecutive patients (70% male) referred for post-infarct VT catheter ablation were included in the present study. The VT isthmus was defined according to the PM method. At each recording site, 10 characteristics of the local EGM were assessed to predict the location of the VT isthmus entrance. In total, 924 EGMs were acquired, of which 127 were located in the VT isthmus entrance. Logistic regression analysis showed that bipolar voltage, number of EGM positive peaks, and sQRS interval were independently associated with VT isthmus entrance location. The ROC curve best fitted the model at the cut-off 0.1641 (sensitivity 72%, specificity 75.2%, positive predictive value 31.3%, negative predictive value 94.4%, area under the curve 0.78, P < 0.001). Based upon these results, we developed an algorithm implemented in an automatic calculator to determine the likelihood that an EGM is located at a VT isthmus entrance. CONCLUSION: Our study suggests that three EGM characteristics: bipolar voltage, number of positive peaks, and sQRS interval can successfully identify a VT isthmus entrance in post-infarct patients.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Algoritmos , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
10.
Card Electrophysiol Clin ; 9(1): 71-80, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28167087

RESUMO

Most postinfarct ventricular tachycardias (VT) are sustained by a reentrant mechanism. The "protected isthmus" of the reentrant circuit is critical for the maintenance of VTs and the target for catheter ablation. In this article, the authors describe the technique of pace-mapping during sinus rhythm to unmask postinfarct VT isthmuses. A pace-mapping map should be considered as the surrogate of an activation map during VT, in both patients with a normal heart and patients with a structural heart disease. Pace mapping is useful to unmask VT isthmuses in patients with postinfarct reentrant VTs.


Assuntos
Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia
11.
Heart Rhythm ; 11(2): 175-81, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24513915

RESUMO

BACKGROUND: Most postinfarct ventricular tachycardias (VTs) are sustained by a reentrant mechanism. The "protected isthmus" of the reentrant circuit is critical for the maintenance of VTs and the target for catheter ablation. Various techniques based on conventional electrophysiology and/or detailed three-dimensional (3D) reconstruction of the VT circuit are used to unmask this isthmus. OBJECTIVE: The purpose of this study was to assess pace-maps (PMs) to identify postinfarct VT isthmuses. We hypothesized that an abrupt change in paced QRS morphology may be used to identify a VT isthmus and be targeted for successful ablation. METHODS: High-density 3D PMs were matched to the subsequent 3D endocardial reentrant VT activation mapping in 10 patients (8 men; age 70.7 ± 10.8 years) who underwent successful postinfarct VT ablation. At each pacing site in a given patient, the 12-lead ECG recorded during pacing was compared to that of VT, with the resulting matching percentage (up to 100% for perfect matches) allocated to this point to generate color-coded PMs. RESULTS: With respect to VT isthmuses, the best percentages of matching were found in the exit zones and isthmus exit part (89% ± 8% and 84% ± 7%, respectively) and the poorest adjacent to scar border in the outer entrance zones (23% ± 28%), in the entrance zones (39% ± 34%), and in the entrance part of the isthmus (32% ± 26%). The color-coded sequence (from the best to the poorest matching sites) on the PMs revealed figure-of-eight pictures matching the VT activation time maps and identifying VT isthmuses. CONCLUSION: Pace-mapping is useful for unmasking VT isthmuses in patients with well-tolerated postinfarct endocardial reentrant VTs.


Assuntos
Eletrocardiografia , Infarto do Miocárdio/complicações , Taquicardia Ventricular/fisiopatologia , Idoso , Mapeamento Potencial de Superfície Corporal , Técnicas de Ablação Endometrial , Feminino , Humanos , Masculino , Taquicardia Ventricular/etiologia
12.
Eur Heart J ; 35(22): 1479-85, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24536081

RESUMO

AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/mortalidade , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Volume Sistólico/fisiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Adulto Jovem
13.
Circ Arrhythm Electrophysiol ; 6(2): 351-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23512203

RESUMO

BACKGROUND: The occurrence of ventricular tachycardia (VT) after myocardial infarction is associated with poorer prognosis. In such patients, implantable cardioverter-defibrillators are recommended. Catheter ablation of VT is currently recommended only as an adjunctive therapy. Whether a successful VT ablation alone might be a viable strategy in some of these patients, however, remains unknown. The aim of the present study was to evaluate this strategy. METHODS AND RESULTS: Between January 2002 and December 2011, 189 patients with cardiomyopathy underwent 259 VT ablations in our center. Forty-five patients (mean age, 65.2±9.6 years; 91% men) with a history of myocardial infarction and mean left ventricular ejection fraction of 39.7±9.7% matched the study criteria and were included in this analysis. Acute success was obtained in 40 of 45 patients (88.9%). During a follow-up, on the basis of our stepwise algorithm (using acute success, repeat electrophysiological study, and recurrence of VT), 19 of 45 patients (42.2%) underwent implantable cardioverter-defibrillators implantation. During a median follow-up of 4.5 (interquartile range, 2.1-7.0) years, all-cause mortality occurred in 14 of 45 patients (31.1%). Using multivariate Cox regression analysis, age (hazard ratio, 1.13; 95% confidence interval, 1.03-1.22; P=0.007) was the only independent predictor of mortality, whereas implantable cardioverter-defibrillators implantation was not (hazard ratio, 0.54; 95% confidence interval, 0.18-1.64; P=0.28) CONCLUSIONS: Our results suggest that a stepwise approach to the management of VT with ablation as a first-line treatment in postinfarct patients presenting with VT might be a reasonable option. Further studies are required to confirm these results.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Infarto do Miocárdio/complicações , Taquicardia Ventricular/cirurgia , Idoso , Feminino , Seguimentos , França/epidemiologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Incidência , Masculino , Infarto do Miocárdio/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Fatores de Tempo
14.
Pacing Clin Electrophysiol ; 35(7): 897-904, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22651845

RESUMO

The number of scar-related ventricular tachycardia (VT) ablation procedures is increasing worldwide. This is certainly due to the ever growing number of patients implanted with an implantable cardioverter defibrillator in whom an ablation procedure may be required to better control the ventricular arrhythmia burden, but is also likely related to our better understanding of the arrhythmias mechanisms as well as the improvement of the mapping techniques during the last 15 years. Most VTs, especially those arising after myocardial infarction, depend on a critical isthmus. Defining precisely the critical isthmus of postinfarct VT may be challenging, particularly when the arrhythmia is poorly tolerated. In the literature, there are extensive data concerning the value of conventional electrophysiological techniques, especially entrainment mapping in association with postpacing interval measurements, regarding the identification of postinfarct VT isthmuses. There are, however, other--sometimes emerging--approaches to image critical postinfarct VT channels. We have summarized these, reviewing data from the published literature as well as our own experience.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Humanos , Infarto do Miocárdio/diagnóstico , Taquicardia Ventricular/diagnóstico
15.
Europace ; 10 Suppl 3: iii70-2, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18955402

RESUMO

In the guidelines, criteria to select patients for cardiac resynchronization therapy (CRT) are based only on the QRS duration on surface electrocardiogram (ECG) as a marker of cardiac dyssynchrony. From a theoretical point, imaging techniques would be useful to improve patient's selection with an analysis of the atrio-ventricular, interventricular and intraventricular dyssynchrony. Imaging techniques may also identify physiopathological issues such as the presence of scar, right ventricular dysfunction, or severe pulmonary hypertension. New echocardiographic techniques appear promising, but the role of echocardiography in the identification of mechanical dyssynchrony remains to be clearly defined in prospective multicentre trials. The positioning of left ventricular lead could be optimized using different imaging techniques to assess the site of latest activation and the coronary sinus anatomy. Finally, imaging techniques may have an important role to optimize the programming of the device, especially the different cardiac timings. In the present article, we focused on echocardiography, multislices-computed tomography, and magnetic resonance imaging being discussed elsewhere.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/prevenção & controle , Aumento da Imagem/métodos , Ultrassonografia de Intervenção/métodos , Humanos
16.
J Interv Card Electrophysiol ; 23(3): 175-81, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18821007

RESUMO

BACKGROUND: Anatomical guided atrial fibrillation (AF) catheter ablation relies on the assumption that the left atrium reconstruction anatomy (LARA) using a 3D mapping system precisely matches the patient's CT scan anatomy (real anatomy). This study investigates whether this postulation is accurate using CT scan image integration. PATIENTS AND METHODS: Thirty consecutive patients (23 men, mean age = 51.9 +/- 9.9 years) with symptomatic drug-refractory paroxysmal (n = 21) or persistent (n = 9) AF underwent a circumferential, 2 x 2, pulmonary vein (PV) radiofrequency (RF) ablation using the CARTOMERGE system. Left atrium (LA) anatomy was first reconstructed and RF design lines drawn on this LARA. After a CT-scan image of the LA was integrated into the 3D system, RF lesions were deployed 10 +/- 5 mm outside the PV ostia (PVO) onto the CT-scan LA surface. The match between the actual RF lines and the RF design lines was analyzed off-line after catheter withdrawal. RESULTS: Circumferential RF design lines were divided into four segments encircling both the right and left PVs. Design segments matched the actual RF segments in a proportion varying from 23% up to 83%. A mean of 2.8 +/- 1.6 segments per patient were inaccurately designed that extended a mean of 3.8 +/- 2.3mm inside the adjacent PV or 6.7 +/- 1.8mm inside the left atrial appendage (LAA). Seven patients (23%) had four or more segments incorrectly designed. CONCLUSIONS: Our study reveals the inaccuracy of 3D anatomic guided RF ablation with respect to the LA anatomical structures that could be possibly improved when combined with CT-scan image integration.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
17.
J Am Coll Cardiol ; 52(10): 839-42, 2008 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-18755347

RESUMO

OBJECTIVES: This study was designed to compare electroanatomic mapping (EAM) and magnetic resonance imaging (MRI) with delayed contrast enhancement (DCE) data for delineation of post-infarct scars. BACKGROUND: Electroanatomic substrate mapping is an important step in the post-infarct ventricular tachycardia (VT) ablation strategy, but this technique has not yet been compared with a gold-standard noninvasive tool informing on the topography and transmural extent of myocardial scars in humans. METHODS: Ten patients (9 men, age 71 +/- 10 years) admitted for post-infarct VT ablation underwent both a left ventricle DCE MRI and a sinus-rhythm 3-dimensional (3D) (CARTO) EAM (Biosense Webster, Johnson & Johnson, Diamond Bar, California). A 3D color-coded MRI-reconstructed left ventricular endocardial shell was generated to display scar data (intramural location and transmural extent). A matching process allocated any CARTO point to its corresponding position on the MRI map. Electrogram (EGM) characteristics were then evaluated in relation to scar data. RESULTS: A spiky EGM morphology, a reduced unipolar or bipolar EGM voltage amplitude (<6.52 and <1.54 mV, respectively), as well as a longer bipolar EGM duration (>56 ms) independently correlated with the presence of scar whatever its intramural position. Endocardial scars had a larger degree of signal reduction than intramural or epicardial scars. None of the parameters was correlated with transmural scar depth. A clear mismatch in infarct surface between CARTO and MRI maps was observed in one-third of infarct zones. CONCLUSIONS: Sinus-rhythm EAM helps identify the limits of post-infarct scars. However, the accuracy of EAM for precise scar delineation is limited. This limit might be circumvented using anatomical information provided by 3D MRI data.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Idoso , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio , Feminino , Ventrículos do Coração/patologia , Humanos , Imageamento Tridimensional/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
18.
Europace ; 7(6): 516-24, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16216751

RESUMO

BACKGROUND: Ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVD) has been previously explored using entrainment mapping techniques but little is know about VT mechanisms and the characteristics of their circuits using an electroanatomical mapping system. METHODS AND RESULTS: Three-dimensional electroanatomical mapping was performed in 11 patients with well tolerated sustained VT and ARVD. Sinus rhythm mapping of the right ventricle was performed in eight patients showing areas of low bipolar electrogram voltage (<1.2 mV). In total 12 tachycardias (mean cycle length 382+/-62 ms) were induced and mapped. Complete maps demonstrated a reentry mechanism in eight VTs and a focal activation pattern in four VTs. The reentrant circuits were localized around the tricuspid annulus (five VTs), around the right ventricular outflow tract (one VT) and on the RV free lateral wall (two VTs). The critical isthmus of each peritricuspid circuit was bounded by the tricuspid annulus with a low voltage area close to it. The isthmus of tachycardia originating from the right ventricular outflow tract (RVOT) was delineated by the tricuspid annulus with a low voltage area localized on the posterior wall of the RVOT. Each right ventricular free wall circuit showed an isthmus delineated by two parallel lines of block. Focal tachycardias originated on the right ventricular free wall. Linear radiofrequency ablation performed across the critical isthmus was successful in seven of eight reentrant tachycardias. The focal VTs were successfully ablated in 50% of cases. During a follow-up of 9-50 months VT recurred in four of eight initially successfully ablated VTs. CONCLUSIONS: Peritricuspid ventricular reentry is a frequent mechanism of VT in patients with ARVD which can be identified by detailed 3D electroanatomical mapping. This novel form of mapping is valuable in identifying VT mechanisms and in guiding RF ablation in patients with ARVD.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter , Feminino , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/complicações , Taquicardia Ventricular/cirurgia
19.
J Cardiovasc Electrophysiol ; 16(7): 681-7, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16050822

RESUMO

UNLABELLED: Postatriotomy atrial tachycardia ablation. INTRODUCTION: In patients without structural heart disease, the most frequently occurring AT is the common atrial flutter. In patients with repaired congenital heart disease other mechanisms of AT may occur, due to the presence of an atriotomy that can provide a substrate for reentry. The aim of the present study was to identify the mechanisms of atrial tachycardia (AT) occurring late after atrial septum defect (ASD) repair, with the help of a three-dimensional electroanatomical mapping system. METHODS AND RESULTS: Twenty-two consecutive patients presenting with AT underwent complete electroanatomic mapping (CARTO, Biosense Webster, Diamond Bar, CA) of spontaneously occurring and inducible right ATs. Complete maps of 26 ATs were obtained. Three tachycardia mechanisms were identified: single-loop macroreentrant atrial tachycardia (MAT) (n=7), double-loop MAT (n=18), and focal AT (n=1). In all MATs, protected isthmuses were identified as the electrophysiological substrate of the arrhythmia, most frequently the cavotricuspid isthmus (CTI) (n=24), and a gap between the inferior vena cava and a line of double potentials (n=11). A mean number of 13.5+/-2.1 radiofrequency applications were delivered to transect these critical parts of the circuit. During a follow-up of 25+/-16 months the RF ablation was acutely successful in all patients. Thirteen patients (59%) had an early recurrence of MAT and needed an additional ablation procedure. One of those patients needed two additional ablation procedures. CONCLUSIONS: Three-dimensional electroanatomic mapping is useful to identify postsurgical AT mechanisms; the CTI isthmus is involved in 92% MAT, and if the right atrial free wall (RAFW) abnormal tissue related to surgical scar is present this substrate contributes to the MAT circuit.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Comunicação Interatrial/cirurgia , Taquicardia/etiologia , Taquicardia/fisiopatologia , Adulto , Ablação por Cateter , Eletrofisiologia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Retratamento , Taquicardia/terapia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...