Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Inorg Chem ; 62(50): 20646-20654, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37625137

RESUMO

44gSc presents a particular interest for application in nuclear medicine for positron emission tomography (PET) due to its favorable nuclear decay properties (t1/2 = 3.97 h, Emax = 1.47 MeV, branching ratio 94.3% ß+). Its nuclear isomer 44mSc (t1/2 = 58.61 h) decays by isomeric transition (IT) into 44gSc, accompanied by ≈12% of conversion electron emission, which can cause a partial release of the daughter 44gSc from the chelate complex. A 13 MeV cyclotron at TRIUMF was used to produce both 44mSc and 44gSc via the natCa(p,n)44m,gSc reaction. A 44mSc/44gSc generator was designed by using a Strata C-18E cartridge. After several tested systems, a successful separation method was developed using DOTATOC as a chelator, a Strata C-18E cartridge as a generator column, and an elution solution of 0.1 M NH4-α-HIB. The yield of the generator with the daughter 44gSc release was equal to 9.8 ± 1.0% (or ≈80% per portion of conversion). This result shows the important role of after-effects in the design of radionuclide generators. Nuclear cross-section calculations were applied using the TALYS code to allow for the determination of the most promising alternative routes for 44mSc production, which will enable the development of a full-scale 44mSc/44gSc radionuclide generator based on after-effects.

2.
Membranes (Basel) ; 13(1)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36676908

RESUMO

A study of the properties of thermoradiationally modified polytetrafluoroethylene and its importance for use as the basis of polymer membranes is presented. The hydrogen permeability of a TRM-PTFE film was studied in comparison with an original PTFE film, and showed a three-fold decrease in hydrogen permeability. Further, TRM-PTFE films were irradiated with accelerated Xe ions with an energy of 1 MeV with fluences from 1 × 108 to 1 × 1011. The changes induced by ion treatment were analyzed by infrared spectroscopy of disturbed total internal reflection (IR-ATR) and by atomic force microscopy (ASM). IR-ATR indicated the absence of destruction in the fluence range from 1 × 108 to 3 × 1010 cm-2 (in the area of isolated tracks) and the beginning of overlap of latent tracks on fluences from 3 × 1010 to 1 × 1011 cm-2. Topographic images with AFM showed layered lamellar structures that collapsed at a fluence of 108 cm-2. The destruction was accompanied by a decrease in roughness about seven times the size of the track core observed by the ASM method, fully corresponding to the value obtained on the basis of calculations using modeling in an SRIM program.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...