Chromatography resins used for purifying biopharmaceuticals are generally dedicated to a single product. In good manufacturing practice (GMP) facilities that manufacture a limited amount of any particular product, this practice can result in the resin being used for a fraction of its useful life. A methodology for extending resin reuse to multiple products is described. With this methodology, resin and column performance, product carryover, and cleaning effectiveness are continually monitored to ensure that product quality is not affected by multiproduct resin reuse (MRR). Resin and column performance is evaluated in terms of (a) system suitability parameters, such as peak-shape and transition, and height equivalent theoretical plate (HETP) data; (b) key operating parameters, such as flow rate, inlet pressure, and pressure drop across the column; and (c) process performance parameters, such as impurity profiles, product quality, and yield. Historical data are used to establish process capability limits (PCLs) for these parameters. Operation within the PCLs provides assurance that column integrity and binding capacity of the resin are not affected by MRR.Product carryover defined as the carryover of the previously processed product (A) into a dose of the subsequently processed product (B) (COA→B), should be acceptable from a predictive patient safety standpoint. A methodology for determining COA→B from first principles and setting acceptance limits for cleaning validation is described.Cleaning effectiveness is evaluated by performing a blank elution run after inter-campaign cleaning and prior to product changeover. The acceptance limits for product carryover (COA→B) are more stringent for MRR than for single-product resin reuse. Thus, the inter-campaign cleaning process should be robust enough to consistently meet the more stringent acceptance limits for MRR. Additionally, the analytical methods should be sensitive enough to adequately quantify the concentration of the previously processed product (A) and its degradants in the eluent.General considerations for designing small-scale chromatographic studies for process development are also described. These studies typically include process-cycling runs with multiple products followed by viral clearance studies with a panel of model viruses. Small-scale studies can be used to optimize cleaning parameters, predict resin performance and product quality, and estimate the number of multiproduct purification cycles that can be run without affecting product quality. The proposed methodology is intended to be broadly applicable; however, it is acknowledged that alternative approaches may be more appropriate for specific scenarios.LAY ABSTRACT: Chromatography resins used for purifying biopharmaceuticals are generally dedicated to a single product. In good manufacturing practice (GMP) facilities that make a limited amount of any particular product, this practice can result in the resin being used for a fraction of its useful life. A methodology for extending resin reuse to multiple products is described. With this methodology, resin and column performance, product carryover, and cleaning effectiveness are continually monitored to ensure that product quality is not affected by multiproduct resin reuse.General considerations for designing small-scale chromatographic studies for process development are described. These studies typically include process-cycling runs with multiple products followed by viral clearance studies with a panel of model viruses. Small-scale studies can be used to optimize cleaning parameters, predict resin performance and product quality, and estimate the number of multiproduct purification cycles that can be run without impacting product quality.The proposed methodology is intended to be broadly applicable; however, it is acknowledged that alternative approaches may be more appropriate for specific scenarios.


Assuntos
Produtos Biológicos/normas , Cromatografia/métodos , Tecnologia Farmacêutica/métodos , Indústria Farmacêutica/métodos , Reutilização de Equipamento , Proteínas Recombinantes/normas , Vírus/isolamento & purificação
2.
Adv Biochem Eng Biotechnol ; 165: 179-210, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29101419

RESUMO

The availability and use of pre-sterilized disposables has greatly changed the methods used in biopharmaceuticals development and production, particularly from mammalian cell culture. Nowadays, almost all process steps from cell expansion, fermentation, cell removal, and purification to formulation and storage of drug substances can be carried out in disposables, although there are still limitations with single-use technologies, particularly in the areas of pretesting and quality control of disposables, bag and connections standardization and qualification, extractables and leachables (E/L) validation, and dependency on individual vendors. The current status of single-use technologies is summarized for all process unit operations using a standard mAb process as an example. In addition, current pros and cons of using disposables are addressed in a comparative way, including quality control and E/L validation.The continuing progress in developing single-use technologies has an important impact on manufacturing facilities, resulting in much faster, less expensive and simpler plant design, start-up, and operation, because cell culture process steps are no longer performed in hard-piped unit operations. This leads to simpler operations in a lab-like environment. Overall it enriches the current landscape of available facilities from standard hard-piped to hard-piped/disposables hybrid to completely single-use-based production plants using the current segregation and containment concept. At the top, disposables in combination with completely and functionally closed systems facilitate a new, revolutionary design of ballroom facilities without or with much less segregation, which enables us to perform good manufacturing practice manufacturing of different products simultaneously in unclassified but controlled areas.Finally, single-use processing in lab-like shell facilities is a big enabler of transferring and establishing production in emergent countries, and this is described in more detail in 7. Graphical Abstract.


Assuntos
Biotecnologia , Técnicas de Cultura de Células , Equipamentos Descartáveis , Animais , Biotecnologia/tendências , Controle de Qualidade
3.
Biotechnol Prog ; 32(3): 718-24, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27071939

RESUMO

Quantifying the clearance of extractables and leachables (E/L) throughout ultrafiltration/diafiltration (UFDF) operations allows for greater flexibility in the implementation of single-use technologies in steps upstream of the UFDF process. A proof-of-concept study was completed in which the clearance of 7 E/L from single-use technologies (trimethylsilanol, hexanoic acid, butyrolactone, t-butyl alcohol, caprolactam, acetonitrile, and benzyl alcohol) in four representative proteins were measured and monitored during the UFDF process using quantitative NMR. This study demonstrated that the defined E/L spiked into a variety of protein solutions can be cleared to <1 ppm by 9 diavolumes from a maximum initial load concentration of 1,000 ppm. However, in some cases a rebound effect was observed in the recovered pool to >1 ppm, which is explained in detail. The overall clearance trend observed for both buffer control and protein-containing solutions resembled the ideal clearance trend where no apparent interactions were observed between E/L with the protein, UFDF system, or with other defined E/L which may be present in the system. Additionally, the UFDF system is capable of clearing these potential E/L from single-use technologies below 1 ppm irrespective of initial concentrations in the load (1,000 or 100 ppm), independently from the type of protein. In general, mass recoveries were within ±15% of each spiked compound in protein solutions and their respective buffer controls, suggesting spiked E/L do not interact strongly with protein. By demonstrating the product independent clearance trends of the spiked E/L across UFDF, these results will contribute to the simplification of the E/L toxicology assessment and allow modular manufacturing approach for single-use technologies in biopharmaceutical manufacturing. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:718-724, 2016.


Assuntos
Proteínas/análise , Ultrafiltração
4.
Biotechnol Prog ; 29(6): 1535-49, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23970490

RESUMO

The use of disposable bags for cell culture media storage has grown significantly in the past decade. Some of the key advantages of using disposable bags relative to non-disposable containers include increased product throughput, decreased cleaning validation costs, reduced risk of cross contamination and lower facility costs. As the scope of use of disposable bags for cell culture applications increases, problematic bags and scenarios should be identified and addressed to continue improving disposables technologies and meet the biotech industry's needs. In this article, we examine a cell culture application wherein media stored in disposable bags is warmed at 37°C before use for cell culture operations. A problematic bag film was identified through a prospective and retrospective cell culture investigation. The investigation provided information on the scope and variation of the issue with respect to different Chinese hamster ovary (CHO) cell lines, cell culture media, and application-specific parameters. It also led to the development of application-specific test methods and enabled a strategy for disposable bag film testing. The strategy was implemented for qualifying an alternative bag film for use in our processes. In this test strategy, multiple lots of 13 bag film types, encompassing eight vendors were evaluated using a three round, cell culture-based test strategy. The test strategy resulted in the determination of four viable bag film options based on the technical data. The results of this evaluation were used to conclude that a volatile or air-quenched compound, likely generated by gamma irradiation of the problematic bag film, negatively impacted cell culture performance.


Assuntos
Células CHO/citologia , Técnicas de Cultura de Células/métodos , Meios de Cultura/química , Animais , Cricetulus , Humanos
5.
J Chromatogr A ; 1227: 154-62, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22265178

RESUMO

Protein A affinity chromatography is widely used for purification of monoclonal antibodies (MAbs) from harvested cell culture fluid (HCCF). At the manufacturing scale, the HCCF is typically loaded on a single Protein A affinity chromatography column in cycles until all of the HCCF is processed. Protein A resin costs are significant, comprising a substantial portion of the raw material costs in MAb manufacturing. Cost can be reduced by operating the process continuously using multiple smaller columns to a higher binding capacity in lieu of one industrial scale column. In this study, a series of experiments were performed using three 1-ml Hi-Trap™ MabSelect SuRe™ columns on a modified ÄKTA™ system operated according to the three Column Periodic Counter Current Chromatography (3C PCC) principle. The columns were loaded individually at different times until the 70% breakthrough point was achieved. The HCCF with unbound protein from the column was then loaded onto the next column to capture the MAb, preventing any protein loss. At any given point, all three columns were in operation, either loading or washing, enabling a reduction in processing time. The product yield and quality were evaluated and compared with a batch process to determine the effect of using the three column continuous process. The continuous operation shows the potential to reduce both resin volume and buffer consumption by ∼40%, however the system hardware and the process is more complex than the batch process. Alternative methods using a single standard affinity column, such as recycling load effluent back to the tank or increasing residence time, were also evaluated to improve Protein A resin efficiency. These alternative methods showed similar cost benefits but required longer processing time.


Assuntos
Cromatografia de Afinidade/instrumentação , Reagentes de Laboratório/química , Resinas Sintéticas/química , Animais , Anticorpos Monoclonais/isolamento & purificação , Células CHO , Cromatografia de Afinidade/métodos , Cricetinae , Cricetulus , Reutilização de Equipamento , Proteína Estafilocócica A/química
6.
Biotechnol Prog ; 26(4): 1200-3, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20730774

RESUMO

Disposable technology is being used more each year in the biotechnology industry. Disposable bioreactors allow one to avoid expenses associated with cleaning, assembly and operations, as well as equipment validation. The WAVE bioreactor is well established for Chinese Hamster Ovary (CHO) production, however, it has not yet been thoroughly tested for E. coli production because of the high oxygen demand and temperature maintenance requirements of that platform. The objective of this study is to establish a robust process to generate inoculum for E. coli production fermentations in a WAVE bioreactor. We opted not to evaluate the WAVE system for production cultures because of the high cell densities required in our current E. coli production processes. Instead, the WAVE bioreactor 20/50 system was evaluated at laboratory scale (10-L) to generate inoculum with target optical densities (OD(550)) of 15 within 7-9 h (pre-established target for stainless steel fermentors). The maximum settings for rock rate (40 rpm) and angle (10.5) were used to maximize mass transfer. The gas feed was also supplemented with additional oxygen to meet the high respiratory demand of the culture. The results showed that the growth profiles for the inoculum cultures were similar to those obtained from conventional stainless steel fermentors. These inoculum cultures were subsequently inoculated into 10-L working volume stainless steel fermentors to evaluate the inocula performance of two different production systems during recombinant protein production. The results of these production cultures using WAVE inocula showed that the growth and recombinant protein production was comparable to the control data set. Furthermore, an economic analysis showed that the WAVE system would require less capital investment for installation and operating expenses would be less than traditional stainless steel systems.


Assuntos
Reatores Biológicos/microbiologia , Escherichia coli/crescimento & desenvolvimento , Fermentação/fisiologia , Animais , Células CHO , Cricetinae , Cricetulus