Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Pediatr Cardiol ; 3(1): 90-1, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20814485

RESUMO

Pulmonary edema after device closure of atrial septal defect (ASD) is a rare complication. We present illustrative images of a case of pulmonary edema after device closure of ASD in a 53 year old adult. Older patients undergoing ASD closure can benefit from their left atrial and left ventricular end diastolic pressures measurement before and after temporary balloon occlusion of ASD.

3.
Indian Heart J ; 57(6): 704-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16521642

RESUMO

BACKGROUND: Use of surgically created aoropulmonary shunt is well-established for improving pulmonary blood flow in infants with critical reduction in pulmonary blood flow. Recently, stenting the patent ductus arteriosus has emerged as an alternative in selected infants with congenital heart disease and reduced pulmonary blood flow. METHODS AND RESULTS: We reviewed records of consecutive infants undergoing stenting of patent ductus arteriosus between August 2003 and October 2005 at our institution. Two of 12 patients underwent patent ductus arteriosus stenting to facilitate preparation of left ventricle for transposition with intact septum. We report the case selection, technique, immediate and short-term follow-up outcome in the remaining 10 patients [median age: 16 days (range 4-290 days): weight 2.7 kg (range 2-6 kg)] with reduced pulmonary blood flow who underwent stenting of patent ductus arteriosus as an alternative to conventional surgical aortopulmonary shunts. Five of the 6 newborns were prostaglandin-dependent and 4 had previously undergone guidewire perforation of the pulmonary valve (n=2) or balloon dilation (n=2). Successful stent implantation was accomplished in all with no major patient-related complication (median fluoroscopy time: 18.6 min; range: 7.7-72 min). The intensive care unit and hospital stays were prolonged in 3 patients because of sepsis (n=2) and pulmonary over-circulation with sepsis (n=1). On follow-up (median 5.5 months; range 1-19 months) all implanted stents were patent. One patient underwent re-dilation of the implanted stent for declining saturations. CONCLUSIONS: The immediate and short-term follow-up results of stenting of the patent arterial duct, as an alternative to the surgical aortopulmonary shunt in carefully selected newborns and infants is encouraging.


Assuntos
Permeabilidade do Canal Arterial/terapia , Circulação Pulmonar/fisiologia , Stents , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Pré-Escolar , Estudos de Coortes , Permeabilidade do Canal Arterial/diagnóstico , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA