Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 146: 108166, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35643022

RESUMO

Venous thromboembolism is one of the major disorders, which is significantly increased the mortality and morbidity rate. Warfarin sodium (WFS) is the most extensively prescribed drug for the prevention of thromboembolic diseases however, it has a narrow therapeutic index. Recently, many methods for detecting and monitoring the level of WFS have been proposed. However, the electrochemical method has gained more interest than the other traditional method due to its ease of operation. This article describes the hydrothermal synthesis of nickel-doped cerium oxide (CeO2@Ni) nanospheres for the selective electrochemical determination of WFS. Various spectroscopic techniques have been used to analyze the chemical composition, and surface morphology of CeO2@Ni nanospheres. Further, the prepared CeO2@Ni nanospheres modified electrode demonstrated excellent electrocatalytic behavior for WFS detection, with an ultralow detection limit of 6.3 × 10-9 M, a linear range of 1.0 × 10-8 M to 1.51 × 10-4 M and 1.51 × 10-4 M to 9.51 × 10-4 M, and a higher sensitivity of 2.9986 µA µM-1 cm2. Therefore, we believe that the CeO2@Ni nanosphere electrocatalyst can serve as a potential electrode catalyst for the sensing of WFS in real-time applications.


Assuntos
Cério , Nanosferas , Cério/química , Técnicas Eletroquímicas/métodos , Eletrodos , Níquel/química , Varfarina
2.
Bioelectrochemistry ; 146: 108145, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35550254

RESUMO

Recently, perovskite structure-based metal oxide nanomaterials and their composites opted for electrocatalyst because of its excellent conductivity, unique, and favored electronic structure. In this attempt, herein we prepared the rare earth mixed metal molybdate covered reduced graphene oxide La2(MoO4)3@rGO nanocomposites by a simple hydrothermal method for the sensitive detection of Moxifloxacin hydrochloride (MOF) in pharmaceutical and human urine samples. The various physicochemical analysis such as SEM, TEM, XRD and Raman spectroscopy confirms the successful formation of (La2(MoO4)3@rGO) nanocomposites. Furthermore, the electroanalytical performance of La2(MoO4)3@rGO modified glassy carbon electrode (La2(MoO4)3@rGO/GCE) was analyzed using the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) which shows excellent results with a wide range of 1.0 × 10-8 M to 6.0 × 10-4 M and the detection limit of 2.84 × 10-9 M towards the MOF detection. Furthermore, the developed sensor expressed good selectivity, repeatability, stability and reproducibility. Finally, the real sample analysis of the developed sensor was tested in the MOF tablets and human urine samples, which shows the appreciable recoveries.


Assuntos
Grafite , Nanocompostos , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite/química , Humanos , Lantânio , Molibdênio , Moxifloxacina , Nanocompostos/química , Reprodutibilidade dos Testes
3.
Chemosphere ; 299: 134434, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35351476

RESUMO

The advancements in electrode materials with high efficiency has been prioritized to effectively monitor the presence of harmful pesticides concerning the environment. In such a way, we hydrothermally constructed a hybrid AgWO4-rGO nanocomposites for the rapid electrochemical detection of crisquat (CQT). The structural, compositional, morphological and topographical characterization for AgWO4-rGO nanocomposites is thoroughly performed to understand its electrocatalytic properties. The AgWO4-rGO nanocomposites are used as an electrode enhancer (rGO@AgWO4/GCE) for the electrochemical investigations towards CQT detection. The results indicated that the rGO@AgWO4/GCE possessed an excellent catalytic activity with a wide linear detection range 1-1108 µM coupled with an ultrasensitive limit of detection (LOD) 0.0661 µM for electrochemical CQT detection. The rGO@AgWO4/GCE CQT sensor also expressed remarkable sensitivity of 0.6306 µAµM-1cm-2 in addition to good selectivity and reproducibility. Furthermore, the commercial CQT, river water, tap water and washed vegetable water are used as a representative for real world analysis using rGO@AgWO4/GCE and results are highly appreciable for the real time CQT detection. Our work proposes a novel hybrid rGO@AgWO4 nanocomposites reinforced electrodes for ultra-trace level CQT detection with good reliability and can be advocated for real time detection of pesticides.


Assuntos
Grafite , Herbicidas , Nanocompostos , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite/química , Nanocompostos/química , Reprodutibilidade dos Testes , Água
4.
Environ Pollut ; 296: 118754, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34973381

RESUMO

We have constructed a dual mode catalytic strip equipped with 2D BiOI nanostructures and deployed for dual mode detection sensing of hazardous trichlorophenol (TCP). Synthesized BiOI nanostructures are investigated for its crystal architecture, morphology and chemical composition. The BiOI are loaded onto the catalytic strips with the assistance of gravity offered drying process. The BiOI nanostructures offers a very less charge transfer resistance indicating its superior catalytic properties upon the electrochemical impedance studies. It reflected on providing an excellent limit of detection (LOD) and linear sensing range for TCP in electrochemical mode. For SERS, a thin plasmonic Au layer is sputter coated on BiOI equipped catalytic strips (Au@BiOI) for the TCP detection. An impressive enhancement factor of 107 is obtained for SERS detection of TCP with good LOD of 10-10 M. Fabricated dual mode BiOI based strips are thoroughly examined for operational stability and performance in real time conditions. The fabricated high performance dual mode platform for the detection of hazardous pesticides appears to be a promising prospect for the on-the-spot investigation.


Assuntos
Nanoestruturas , Praguicidas , Catálise , Limite de Detecção , Água
5.
Environ Res ; 205: 112515, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34896319

RESUMO

In this work, the hydrothermally synthesized of BiVO4@MoS2 hierarchical nano-heterojunction composite is employed as a novel electrocatalyst for electrochemical sensing of Furazolidone (FZE) drug by modifying the glassy carbon electrodes (GCE). The Raman spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy and transmission electron microscopy are used to thoroughly investigate the functional groups, vibrational modes, crystal structure, elemental composition and surface topography of the heterojunction composite. The physical characterization results revealed the successful construction of 1D-2D BiVO4@MoS2 hierarchical nano-heterojunction composite. When these unique architectures are reinforced on GCE surface, we achieved an enhanced electroactive surface area of 0.154 cm2. The electrochemical performance of 1D-2D BiVO4@MoS2 is examined though cyclic voltammetry and differential pulse voltammetry (DPV) analysis. The BiVO4@MoS2 composites exhibited an excellent electrocatalytic activity in sensing of FZE with superior linear detection ranges of 0.01-14 and 14-614 µM. The limit of detection (LOD) of the BiVO4@MoS2 based sensor is determined to be 2.9 nM which is far superior than other reported FZE sensors. Consequently, it is evident from the investigation that the BiVO4@MoS2 based FZE sensor can be recommended for analyzing real time samples like human urine and blood serum with appreciable recovery.


Assuntos
Furazolidona , Molibdênio , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Limite de Detecção , Molibdênio/química
6.
Mikrochim Acta ; 188(9): 315, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34462824

RESUMO

Selective and sensitive dopamine (DPA) sensor was developed using hydrothermally prepared functionalized multi-walled carbon nanotube-coated bismuth molybdate (f-MWCNT@BMO). The f-MWCNT@BMO-reinforced electrode exhibited an outstanding electrocatalytic activity towards DPA oxidation. The nanocomposite-reinforced electrode displayed a rapid response towards DPA sensing and possessed the minimized potential of (Epa + 0.285 V vs Ag/AgCl) in 0.1 M phosphate buffer (PB). The electrochemical results of prepared sensors were analyzed using the differential pulse voltammetry method (DPV). As a result, the f-MWCNT@BMO-reinforced electrode exhibited a widelinear range of 10 nM - 814 µM with a very low detection limit of 3.4 nM towards DPA oxidation. The developed sensor shows excellent selectivity in presence of similar functional group biomolecules. The detection of DPA in real samples was evaluated in human serum, as the results of the proposed sensor possessed good recoveries.


Assuntos
Dopamina/sangue , Nanocompostos/química , Nanotubos de Carbono/química , Bismuto/química , Dopamina/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Limite de Detecção , Molibdênio/química , Oxirredução , Reprodutibilidade dos Testes
7.
Mikrochim Acta ; 188(3): 102, 2021 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-33638711

RESUMO

Metastable and rarely reported GO warped tetragonal phase t-lanthanum vanadate nanocomposites (GO@LaVO4-NCs) are reported for the sensitive electrochemical determination of antifungal drug Clioquinol (CQ). The hydrothermal method was adopted for synthesis of GO@LaVO4-NCs. The electrochemical performance of CQ was examined using cyclic voltammetry (CV) and differential plus voltammetry (DPV) at GO@LaVO4-NCs modified glassy carbon electrode (GCE). The electrocatalytic oxidation of CQ at the GO@LaVO4-NCs/GCE shows the highest anodic peak current at a potential of +0.51 V vs. Ag/AgCl. The proposed sensor provides excellent sensitivity of 4.1894 µA µM-1 cm-2, a very low detection limit (LOD) of 2.44 nM, and a wide range of 25 nM to 438.52 µM towards CQ detection. Finally, the detection of CQ in biological media was successfully done using the GO@LaVO4-NCs/GCE and possesses recoveries of 94.67-98.0%.


Assuntos
Antifúngicos/análise , Antiprotozoários/análise , Clioquinol/análise , Técnicas Eletroquímicas/métodos , Nanocompostos/química , Antifúngicos/sangue , Antifúngicos/química , Antifúngicos/urina , Antiprotozoários/sangue , Antiprotozoários/química , Antiprotozoários/urina , Clioquinol/sangue , Clioquinol/química , Clioquinol/urina , Grafite/química , Humanos , Lantânio/química , Limite de Detecção , Oxirredução , Reprodutibilidade dos Testes , Vanadatos/química
8.
Mikrochim Acta ; 188(3): 72, 2021 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-33550432

RESUMO

The low-temperature synthesis of the graphene oxide-wrapped perovskite-type strontium titanate nanocomposites (GO@SrTiO3-NC) is reported for the electrochemical sensing of organochlorine pesticide 2,4,6-trichlorophenol (TCP) detection. The as-prepared GO@SrTiO3 nanocomposites provide a large surface area, excellent conductivity, and active sites, which are more favorable to the catalysis of TCP. The synergistic effect between the GO and the perovskite SrTiO3 results in the extended working range of 0.01 to 1.47 and 1.47 to 434.4 µM with a very low detection limit of 3.21 nM towards TCP detection. Moreover, the prepared sensor possessed good selectivity and long-term stability. Finally, the practical applicability of the sensor was tested in environmental samples of river water and soil, exhibiting adequate recovery values.


Assuntos
Clorofenóis/análise , Nanocompostos/química , Praguicidas/análise , Poluentes do Solo/análise , Poluentes Químicos da Água/análise , Temperatura Baixa , Técnicas Eletroquímicas , Grafite/química , Química Verde , Limite de Detecção , Óxidos/química , Rios/química , Estrôncio/química , Titânio/química
9.
Nanotechnology ; 31(44): 445502, 2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-32796153

RESUMO

In this study, we have prepared anatase titanium (IV) oxide warped reduced graphene oxide nanocomposites (TiO2-rGO NC) using ultrasonic methodology. The morphology of the TiO2-rGO NC was studied using FESEM and TEM. In addition, XRD, Raman, thermogravimetric analysis (TGA) and XPS are used to analyze the crystallinity and chemical composition of the TiO2-rGO NC. We have also investigated the electrochemical behavior of the as-prepared NCs with electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and different pulse voltammetry techniques (DPV). The TiO2-rGO NC modified electrode shows the lower charge transfer resistance (R ct ) of 62.87 Ω. Next, the glassy carbon electrode (GCE) was modified with sonochemically prepared TiO2-rGO NC and used to determine the electrocatalytic reduction of nitrofurazone (NTF). Thus, the proposed sensor established the wider covering range (WCR) of 0.01 to 380 µM and an excellent detection limit of 2.28 nM. Finally, the TiO2-rGO NC/GCE was applied to determine the NTF in real samples, including crayfish and human blood serum samples, which acquired good found and recovery values.


Assuntos
Anti-Infecciosos/análise , Contaminação de Alimentos/análise , Grafite/química , Nanoestruturas/química , Nitrofurazona/análise , Titânio/química , Animais , Anti-Infecciosos/sangue , Técnicas Eletroquímicas/métodos , Eletrodos , Peixes/metabolismo , Humanos , Nitrofurazona/sangue , Oxirredução
10.
Int J Mol Sci ; 21(9)2020 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-32380772

RESUMO

Various factors leads to cancer; among them oxidative damage is believed to play an important role. Moreover, it is important to identify a method to detect the oxidative damage. Recently, electrochemical sensors have been considered as the one of the most important techniques to detect DNA damage, owing to its rapid detection. However, electrode materials play an important role in the properties of electrochemical sensor. Currently, researchers have aimed to develop novel electrode materials for low-level detection of biomarkers. Herein, we report the facile hydrothermal synthesis of NiCo2O4 micro flowers (MFs) and NiCo2S4 micro spheres (Ms) and evaluate their electrochemical properties for the detection of carcinogen-causing biomarker 4-nitroquinoline n-oxide (4-NQO) in human blood serum and saliva samples. Moreover, as-prepared composites were fabricated on a glass carbon electrode (GCE), and its electrochemical activities for the determination of 4-NQO were investigated by using various electrochemical techniques. Fascinatingly, the NiCo2S4-Ms showed a very low detection limit of 2.29 nM and a wider range of 0.005 to 596.64 µM for detecting 4-NQO. Finally, the practical applicability of NiCo2S4-Ms in the 4-NQO spiked human blood serum and saliva samples were also investigated.


Assuntos
Técnicas Biossensoriais , Carcinógenos/análise , Técnicas Eletroquímicas , Nitroquinolinas/análise , Estresse Oxidativo , Técnicas de Química Sintética , Eletrodos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Níquel/química , Sensibilidade e Especificidade , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...