Rev Sci Instrum ; 93(11): 113311, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461536

RESUMO

The absolute response of a real-time proton detector, composed of a microchannel plate (MCP) assembly, an imaging lens, and a charge-coupled device (CCD) camera, is calibrated for the spectral characterization of laser-accelerated protons, using a Thomson parabola spectrometer (TPS). A slotted CR-39 plate was used as an absolute particle-counting detector in the TPS, simultaneously with the MCP-CCD detector to obtain a calibration factor (count/proton). In order to obtain the calibration factor as a function of proton energy for a wide range of proton numbers, the absolute response was investigated for different operation parameters of the MCP-CCD detector, such as MCP voltage, phosphor voltage, and CCD gain. A theoretical calculation for the net response of the MCP was in good agreement with the calibrated response of the MCP-CCD detector, and allows us to extend the response to higher proton energies. The response varies in two orders of magnitude, showing an exponential increase with the MCP voltage and almost linear increase with the phosphor voltage and the CCD gain. The calibrated detector enabled characterization of a proton energy spectrum in a wide dynamic range of proton numbers. Moreover, two MCP assemblies having different structures of MCP, phosphor screen, and optical output window have been calibrated, and the difference in the absolute response was highlighted. The highly-sensitive detector operated with maximum values of the parameters enables measuring a single proton particle and evaluating an absolute spectrum at high proton energies in a single laser shot. The absolute calibrations can be applied for the spectral measurement of protons using different operating voltages and gains for optimized response in a large range of proton energy and number.

2.
Rev Sci Instrum ; 92(2): 023302, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648087

RESUMO

We present a proof of principle for onsite calibration of a radiochromic film (EBT3) using CR-39 as an absolute proton-counting detector and laser-accelerated protons as a calibration source. A special detector assembly composed of aluminum range filters, an EBT3 film, and a CR-39 detector is used to expose the EBT3 film with protons in an energy range of 3.65 MeV-5.85 MeV. In our design, the proton beam is divided into small beamlets and their projection images are taken on the EBT3 film and the CR-39 detector by maintaining a certain distance between the two detectors. Owing to the geometrical factor of the configuration and scattering inside the EBT3, the areal number density of protons was kept below the saturation level of the CR-39 detector. We also present a method to relate the number of protons detected on the CR-39 in a narrow energy range to protons with a broad energy spectrum that contribute to the dose deposited in the EBT3 film. The energy spectrum of protons emitted along the target normal direction is simultaneously measured using another CR-39 detector installed in a Thomson parabola spectrometer. The calibration curves for the EBT3 film were obtained in the optical density range of 0.01-0.25 for low dose values of 0.1 Gy-3.0 Gy. Our results are in good agreement with the calibrations of the EBT3 film that are traditionally carried out using conventional accelerators. The method presented here can be further extended for onsite calibration of radiochromic films of other types and for a higher range of dose values.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...