Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
4.
Int J Cardiol ; 367: 81-89, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35944765

RESUMO

Sacubitril/valsartan is a first-in-class Angiotensin Receptor-Neprilysin inhibitor (ARNi) to be approved for the treatment of heart failure with reduced ejection fraction (HFrEF). The combination tablet has become a mainstay of treatment in the management of heart failure (HF) due to its composite inhibition of the neurohumoral system. There is growing support to show that sacubitril/valsartan may enhance glycaemic control through the augmentation of neprilysin substrates - in particular, glucagon-like peptide 1 (GLP-1). Given that HF and Diabetes Mellitus (DM) frequently coexist, with 44% of patients hospitalised with heart failure also having diabetes as a co-morbidity, it is plausible that sacubitril/valsartan may represent a novel way to address glucose intolerance in HF. However, the role of neprilysin in the degradation of GLP-1 raises important clinical considerations such as the risk of hypoglycaemia and potential drug-drug interactions in patients with and without concurrent DM. We review the current body of research addressing the effect of neprilysin inhibition on GLP-1 receptor signalling and discuss the implications for treatment of HF and DM.


Assuntos
Insuficiência Cardíaca , Neprilisina , Aminobutiratos , Antagonistas de Receptores de Angiotensina/farmacologia , Antagonistas de Receptores de Angiotensina/uso terapêutico , Compostos de Bifenilo/farmacologia , Combinação de Medicamentos , Peptídeo 1 Semelhante ao Glucagon/uso terapêutico , Receptor do Peptídeo Semelhante ao Glucagon 1 , Controle Glicêmico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Receptores de Angiotensina , Volume Sistólico , Tetrazóis/farmacologia , Valsartana/uso terapêutico
5.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671359

RESUMO

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Punções/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
6.
Am J Med Genet A ; 188(7): 2192-2197, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35396906

RESUMO

The Ehlers-Danlos Syndromes (EDS) are a group of inherited connective tissue disorders with a worldwide prevalence of 1 in 2500 to 1 in 5000 births irrespective of sex or ethnicity. Fourteen subtypes of Ehlers-Danlos Syndrome (EDS) have been described, each with characteristic phenotypes and associated genes. Pathogenic variants in COL5A1 and COL5A2 cause the classical EDS subtypes. Pathogenic variants in COL3A1 cause vascular EDS. In this case report, we describe a patient with a phenotype resembling that of vascular EDS, caused by a novel pathogenic variant in COL5A1.


Assuntos
Síndrome de Ehlers-Danlos , Anormalidades da Pele , Colágeno/genética , Colágeno Tipo V/genética , Síndrome de Ehlers-Danlos/diagnóstico , Síndrome de Ehlers-Danlos/genética , Síndrome de Ehlers-Danlos/patologia , Humanos , Mutação , Fenótipo , Anormalidades da Pele/genética
7.
Hum Hered ; 86(1-4): 28-33, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34706366

RESUMO

Multiple familial diseases in a single patient often present with overlapping symptomatology that confers difficulty in delineating a clinical diagnosis. Pedigree analysis has been a long-standing practice in the field of medical genetics to discover familial diseases. In recent years, whole exome sequencing (WES) has proven to be a useful tool for aiding physicians in diagnosing and understanding disease etiology. This report shows that pedigree analysis and WES are co-dependent processes in establishing diagnoses in a family with 4 different genetic disorders: Birt-Hogg-Dubé Syndrome, RRM2B-related mitochondrial disease, CDC73-related primary hyperparathyroidism, and familial prostate cancer.


Assuntos
Síndrome de Birt-Hogg-Dubé , Hiperparatireoidismo Primário , Síndrome de Birt-Hogg-Dubé/genética , Exoma/genética , Humanos , Masculino , Linhagem , Sequenciamento do Exoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...