Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cosmet Sci ; 65(5): 265-76, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25682618

RESUMO

Methods have been developed for the determination of zinc pyrithione (ZPT) in shampoos using high-performance liquid chromatography (HPLC) and high-performance liquid chromatography-mass spectrometry/mass spectrometry (HPLC-MS/MS). Samples were washed by water first to remove surfactant and water-soluble impurities, then ultrasonic-extracted by acetonitrile-methanol for 30 min, and finally analyzed by MG C18 column (250 mm x 4.6 mm, 5 µm) or RP-18e (100 mm x 3 mm, 2 µm) plus APCI-MS/MS. Limits of detection were determined as 0.015% (HPLC) and 0.003% (HPLC-MS/MS), with a limit of quantization of 0.05% and 0.01%, respectively. The recoveries were 85.8-104% (HPLC) and 87.6-107% (HPLC-MS/MS). A good linear relationship was obtained from 3.20 µg·ml(-1) to 200 µg·ml(-1) (HPLC) and 1.00 µg·ml(-1) to 200 µg·ml(-1) (HPLC-MS/MS). The proposed methods have been successfully applied to the analysis of ZPT in many shampoos. The established two methods were rapid and reproducible with low interference.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Preparações para Cabelo/química , Compostos Organometálicos/análise , Piridinas/análise , Espectrometria de Massas em Tandem/métodos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...