Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Int J Sports Phys Ther ; 19(5): 535-547, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38707847

RESUMO

Background: Sidestep cutting technique is highly individual and has been shown to influence knee joint loading. However, studies assessing whether individualized technique feedback improves technique and ACL injury-relevant knee joint loads instantly in a sport-specific task are lacking. Purpose: To determine the instant effects of individualized augmented technique feedback and instructions on technique and the peak external knee abduction moment (pKAM) in a handball-specific sidestep cut. Additionally, to determine the effects of technique modifications on the resultant ground reaction force and its frontal plane moment arm to the knee joint center. Study Design: Controlled laboratory cohort study. Methods: Three-dimensional biomechanics of 48 adolescent female handball players were recorded during a handball-specific sidestep cut. Following baseline cuts to each side, leg-specific visual and verbal technique feedback on foot strike angle, knee valgus motion, or vertical impact velocity using a hierarchically organized structure accounting for the variables' association with performance was provided. Subsequently, sidestep cuts were performed again while verbal instructions were provided to guide technique modifications. Combined effects of feedback and instructions on technique and pKAM as well as on the resultant ground reaction force and its frontal plane moment arm to the knee joint center were assessed. Results: On average, each targeted technique variable improved following feedback and instructions, leading to instant reductions in pKAM of 13.4% to 17.1%. High inter-individual differences in response to feedback-instruction combinations were observed. These differences were evident in both the adherence to instructions and the impact on pKAM and its components. Conclusion: Most players were able to instantly adapt their technique and decrease ACL injury-relevant knee joint loads through individualized augmented technique feedback, thereby potentially reducing the risk of injury. More research is needed to assess the retention of these adaptations and move towards on-field technique assessments using low-cost equipment. Level of Evidence: Level 3.

2.
Front Sports Act Living ; 6: 1340154, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38645727

RESUMO

In a randomized controlled cross-over study ten male runners (26.7 ± 4.9 years; recent 5-km time: 18:37 ± 1:07 min:s) performed an incremental treadmill test (ITT) and a 3-km time trial (3-km TT) on a treadmill while wearing either carbon fiber insoles with downwards curvature or insoles made of butyl rubber (control condition) in light road racing shoes (Saucony Fastwitch 9). Oxygen uptake, respiratory exchange ratio, heart rate, blood lactate concentration, stride frequency, stride length and time to exhaustion were assessed during ITT. After ITT, all runners rated their perceived exertion, perceived shoe comfort and perceived shoe performance. Running time, heart rate, blood lactate levels, stride frequency and stride length were recorded during, and shoe comfort and shoe performance after, the 3-km TT. All parameters obtained during or after the ITT did not differ between the two conditions [range: p = 0.188 to 0.948 (alpha value: 0.05); Cohen's d = 0.021 to 0.479] despite the rating of shoe comfort showing better scores for the control insoles (p = 0.001; d = -1.646). All parameters during and after the 3-km TT showed no differences (p = 0.200 to 1.000; d = 0.000 to 0.501) between both conditions except for shoe comfort showing better scores for control insoles (p = 0.017; d = -0.919). Running with carbon fiber insoles with downwards curvature did not change running performance or any submaximal or maximal physiological or biomechanical parameter and perceived exertion compared to control condition. Shoe comfort is impaired while running with carbon fiber insoles. Wearing carbon fiber insoles with downwards curvature during treadmill running is not beneficial when compared to running with control insoles.

3.
Sports Biomech ; : 1-17, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451183

RESUMO

Biomechanical measurements of accidental ankle sprain injuries are rare but make important contributions to a more detailed understanding of the injury mechanism. In this case study, we present the kinematics and kinetics of a lateral ankle sprain of a female athlete performing handball-specific fake-and-cut manoeuvres. Three-dimensional kinematics and kinetics were recorded and six previously performed trials were used as reference. Plantarflexion, inversion, and internal rotation angles were substantially larger than the reference trials and peaked between 190 and 200 ms after initial ground contact. We observed a highly increased inversion and internal rotation moment. However, compared to the non-injury trials the data also revealed a reduction in the second dorsiflexion moment peak. Ground reaction forces were lower throughout the injury trial. Other parameters at initial ground contact including ankle and hip position, step length, and the traction coefficient indicate that a preparatory maladjustment occurred. This study adds valuable contributions to the understanding of lateral ankle sprains by building upon previously published reports and considering the shoe-surface interaction as an important factor for injury.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38454792

RESUMO

PURPOSE: The purpose of this study was to investigate the impact of sex on knee function, activity and quality of life following meniscus surgery using data from the German Arthroscopy Registry. METHODS: This is a retrospective cohort study with data collected between 2017 and 2022. Patient-reported outcome measures (PROMs), namely Knee Injury and Osteoarthritis Outcome Score (KOOS), EuroQol Visual Analogue Scale (EQ Scale), and Marx Activity Rating Scale (MARS), were collected preoperatively and at 6, 12 and 24 months postoperatively. Data were analysed to examine differences between male and female patients regarding PROMs, pre-existing conditions, meniscus lesion types and surgical treatments. RESULTS: A total of 1106 female (36.6%) and 1945 male patients (63.7%) were included. Males were significantly younger than females and had a higher body mass index. Overall, there were four times more medial meniscus lesions (MMLs) (77.5%) than lateral meniscus lesions (LMLs) (27.9%). Degenerative LMLs were more frequent in females, while traumatic LMLs were more common in males. Frequencies of traumatic and degenerative MMLs were similar among males and females. Males had higher absolute KOOS irrespective of treatment or meniscus lesion type. Meniscus repair resulted in similar improvements in ΔKOOS for both sexes, while meniscus resection exhibited higher absolute KOOS for males at each time point. Males generally had higher EQ Scale and MARS than females. CONCLUSION: Greater improvements in knee function, activity and quality of life were observed in males. While MMLs appear to be comparable among sexes, the nature of LML differed significantly. These results may help surgeons to refine patient selection for specific treatments to improve overall clinical outcomes. LEVEL OF EVIDENCE: Level III.

5.
Sports Med Open ; 10(1): 14, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332220

RESUMO

Advanced footwear technology (AFT) is currently being debated in sports. There is a direct evidence that distance running in AFT improves running economy. In addition, there is indirect evidence from competition performance for improved running performance from using AFTs in middle- and long-distance running and sprinting events. However, the extent to which world-class performance is affected across the full range of track and road racing events between genders has not been systematically analyzed. This study examined publicly available performance datasets of annual best track and road performances for evidence of potential systematic performance effects following the introduction of AFT. The analysis was based on the 100 best performances per year for men and women in outdoor events from 2010 to 2022, provided by the world governing body of athletics (World Athletics). We found evidence of progressing improvements in track and road running performances after the introduction of AFT for road races in 2016 and AFT for track racing in 2019. This evidence is more pronounced for distances longer than 1500 m in women and longer than 5000 m in men. Women seem to benefit more from AFT in distance running events than men. For the sprint events (100 m to 400 m hurdles), the peak performance gains in 2021 and 2022 compared to the pre-AFT period ranged from 0.6 to 1.1% and from 0.4 to 0.7% for women and men, respectively. For middle-distance events (400 m to 3000 m steeplechase), peak performance gains ranged from 0.6 to 1.9% and from 0.6 to 0.7% for women and men, respectively. For distances from 5000 m to the marathon, performance gains ranged from 2.2% to 3.5% and 0.7% to 1.4% for women and men, respectively. While the observational study design limits causal inference, this study provides a database on potential systematic performance effects after introducing advanced shoes/spikes in track and road running events in world-class athletes. Further research is needed to examine the underlying mechanisms and, in particular, potential gender differences in the performance effects of AFT.

6.
J Sport Health Sci ; 13(1): 118-124, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36931595

RESUMO

BACKGROUND: Internal tibial loading is influenced by modifiable factors with implications for the risk of stress injury. Runners encounter varied surface steepness (gradients) when running outdoors and may adapt their speed according to the gradient. This study aimed to quantify tibial bending moments and stress at the anterior and posterior peripheries when running at different speeds on surfaces of different gradients. METHODS: Twenty recreational runners ran on a treadmill at 3 different speeds (2.5 m/s, 3.0 m/s, and 3.5 m/s) and gradients (level: 0%; uphill: +5%, +10%, and +15%; downhill: -5%, -10%, and -15%). Force and marker data were collected synchronously throughout. Bending moments were estimated at the distal third centroid of the tibia about the medial-lateral axis by ensuring static equilibrium at each 1% of stance. Stress was derived from bending moments at the anterior and posterior peripheries by modeling the tibia as a hollow ellipse. Two-way repeated-measures analysis of variance were conducted using both functional and discrete statistical analyses. RESULTS: There were significant main effects for running speed and gradient on peak bending moments and peak anterior and posterior stress. Higher running speeds resulted in greater tibial loading. Running uphill at +10% and +15% resulted in greater tibial loading than level running. Running downhill at -10% and -15% resulted in reduced tibial loading compared to level running. There was no difference between +5% or -5% and level running. CONCLUSION: Running at faster speeds and uphill on gradients ≥+10% increased internal tibial loading, whereas slower running and downhill running on gradients ≥-10% reduced internal loading. Adapting running speed according to the gradient could be a protective mechanism, providing runners with a strategy to minimize the risk of tibial stress injuries.


Assuntos
Corrida , Tíbia , Tíbia/lesões , Fenômenos Biomecânicos , Corrida/lesões , Teste de Esforço , Proteínas do Tecido Nervoso
7.
Sports Med ; 54(1): 203-211, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37632664

RESUMO

BACKGROUND: Video analysis (VA) is commonly used in the assessment of sports injuries and has received considerable research interest. Until now, no tool has been available for the assessment of study quality. Therefore, the objective of this study was to develop and evaluate a valid instrument that reliably assesses the methodological quality of VA studies. METHODS: The Quality Appraisal for Sports Injury Video Analysis Studies (QA-SIVAS) scale was developed using a modified Delphi approach including expert consensus and pilot testing. Reliability was examined through intraclass correlation coefficient (ICC3,1) and free-marginal kappa statistics by three independent raters. Construct validity was investigated by comparing QA-SIVAS with expert ratings by using Kendall's tau analysis. Rating time was studied by applying the scale to 21 studies and computing the mean time for rating per study article. RESULTS: The QA-SIVAS scale consists of an 18-item checklist addressing the study design, data source, conduct, report, and discussion of VA studies in sports injury research. Inter- and intra-rater reliability were excellent with ICCs > 0.97. Expert ratings revealed a high construct validity (0.71; p < 0.001). Mean rating time was 10 ± 2 min per article. CONCLUSION: QA-SIVAS is a reliable and valid instrument that can be easily applied to sports injury research. Future studies in the field of VA should adhere to standardized methodological criteria and strict quality guidelines.


Assuntos
Traumatismos em Atletas , Humanos , Reprodutibilidade dos Testes , Lista de Checagem , Projetos de Pesquisa
8.
BMC Sports Sci Med Rehabil ; 15(1): 152, 2023 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37951935

RESUMO

Injury prevention is essential in running due to the risk of overuse injury development. Tailoring running shoes to individual needs may be a promising strategy to reduce this risk. Novel manufacturing processes allow the production of individualised running shoes that incorporate features that meet individual biomechanical and experiential needs. However, specific ways to individualise footwear to reduce injury risk are poorly understood. Therefore, this scoping review provides an overview of (1) footwear design features that have the potential for individualisation; and (2) the literature on the differential responses to footwear design features between selected groups of individuals. These purposes focus exclusively on reducing the risk of overuse injuries. We included studies in the English language on adults that analysed: (1) potential interaction effects between footwear design features and subgroups of runners or covariates (e.g., age, sex) for running-related biomechanical risk factors or injury incidences; (2) footwear comfort perception for a systematically modified footwear design feature. Most of the included articles (n = 107) analysed male runners. Female runners may be more susceptible to footwear-induced changes and overuse injury development; future research should target more heterogonous sampling. Several footwear design features (e.g., midsole characteristics, upper, outsole profile) show potential for individualisation. However, the literature addressing individualised footwear solutions and the potential to reduce biomechanical risk factors is limited. Future studies should leverage more extensive data collections considering relevant covariates and subgroups while systematically modifying isolated footwear design features to inform footwear individualisation.

9.
Orthopadie (Heidelb) ; 52(8): 610-617, 2023 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-37391676

RESUMO

BACKGROUND: Complex biomechanical motion analysis can provide relevant information for a variety of orthopedic problems. When purchasing motion analysis systems, in addition to the classical measurement quality criteria (validity, reliability, objectivity), spatial and temporal conditions, as well as the requirements for the qualification of the measuring personnel should be considered. APPLICATION: In complex movement analysis, systems are used to determine kinematics, kinetics and muscle activity (electromyography). This article gives an overview of methods of complex biomechanical motion analysis for use in orthopaedic research or for individual patient care. In addition to the use for pure movement analysis, the use of movement analysis methods in the field of biofeedback training is discussed. ACQUISITION: For the specific acquisition of motion analysis systems, it is recommended to contact professional societies (e.g., the German Society for Biomechanics),universities with existing motion analysis facilities or distributors in the field of biomechanics.


Assuntos
Cirurgiões Ortopédicos , Humanos , Reprodutibilidade dos Testes , Movimento (Física) , Movimento/fisiologia , Eletromiografia/métodos
10.
Am J Sports Med ; 51(3): 715-722, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36734465

RESUMO

BACKGROUND: Ankle braces aim to reduce lateral ankle sprains. Next to protection, factors influencing user compliance, such as sports performance, motion restriction, and users' perceptions, are relevant for user compliance and thus injury prevention. Novel adaptive protection systems claim to change their mechanical behavior based on the intensity of motion (eg, the inversion velocity), unlike traditional passive concepts of ankle bracing. PURPOSE: To compare the performance of a novel adaptive brace with 2 passive ankle braces while considering protection, sports performance, freedom of motion, and subjective perception. STUDY DESIGN: Controlled laboratory study. METHODS: The authors analyzed 1 adaptive and 2 passive (one lace-up and one rigid brace) ankle braces, worn in a low-cut, indoor sports shoe, which was also the no-brace reference condition. We performed material testing using an artificial ankle joint system at high and low inversion velocities. Further, 20 male, young, healthy team sports athletes were analyzed using 3-dimensional motion analysis in sports-related movements to address protection, sports performance, and active range of motion dimensions. Participants rated subjective comfort, stability, and restriction experienced when using the products. RESULTS: Subjective stability rating was not different between the adaptive and passive systems. The rigid brace was superior in restricting peak inversion during the biomechanical testing compared with the passive braces. However, in the material test, the adaptive brace increased its stiffness by approximately 400% during the fast compared with the slow inversion velocities, demonstrating its adaptive behavior and similar stiffness values to passive braces. We identified minor differences in sports performance tasks. The adaptive brace improved active ankle range of motion and subjective comfort and restriction ratings. CONCLUSION: The adaptive brace offered similar protective effects in high-velocity inversion situations to those of the passive braces while improving range of motion, comfort, and restriction rating during noninjurious motions. CLINICAL RELEVANCE: Protection systems are only effective when used. Compared with traditional passive ankle brace technologies, the novel adaptive brace might increase user compliance by improving comfort and freedom of movement while offering similar protection in injurious situations.


Assuntos
Traumatismos do Tornozelo , Desempenho Atlético , Humanos , Masculino , Tornozelo , Articulação do Tornozelo , Traumatismos do Tornozelo/prevenção & controle , Extremidade Inferior
11.
Front Sports Act Living ; 4: 983888, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36439622

RESUMO

Non-contact anterior cruciate ligament injuries typically occur during cutting maneuvers and are associated with high peak knee abduction moments (KAM) within early stance. To screen athletes for injury risk or quantify the efficacy of prevention programs, it may be necessary to design tasks that mimic game situations. Thus, this study compared KAMs and ranking consistency of female handball players in three sport-specific fake-and-cut tasks of increasing complexity. The biomechanics of female handball players (n = 51, mean ± SD: 66.9 ± 7.8 kg, 1.74 ± 0.06 m, 19.2 ± 3.4 years) were recorded with a 3D motion capture system and force plates during three standardized fake-and-cut tasks. Task 1 was designed as a simple pre-planned cut, task 2 included catching a ball before a pre-planned cut in front of a static defender, and task 3 was designed as an unanticipated cut with three dynamic defenders involved. Inverse dynamics were used to calculate peak KAM within the first 100 ms of stance. KAM was decomposed into the frontal plane knee joint moment arm and resultant ground reaction force. RANOVAs (α ≤ 0.05) were used to reveal differences in the KAM magnitudes, moment arm, and resultant ground reaction force for the three tasks. Spearman's rank correlations were calculated to test the ranking consistency of the athletes' KAMs. There was a significant task main effect on KAM (p = 0.02; η p 2 = 0.13). The KAM in the two complex tasks was significantly higher (task 2: 1.73 Nm/kg; task 3: 1.64 Nm/kg) than the KAM in the simplest task (task 1: 1.52 Nm/kg). The ranking of the peak KAM was consistent regardless of the task complexity. Comparing tasks 1 and 2, an increase in KAM resulted from an increased frontal plane moment arm. Comparing tasks 1 and 3, higher KAM in task 3 resulted from an interplay between both moment arm and the resultant ground reaction force. In contrast to previous studies, unanticipated cutting maneuvers did not produce the highest KAMs. These findings indicate that the players have developed an automated sport-specific cutting technique that is utilized in both pre-planned and unanticipated fake-and-cut tasks.

12.
Front Sports Act Living ; 4: 983889, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36225972

RESUMO

Young female handball players represent a high-risk population for anterior cruciate ligament (ACL) injuries. While the external knee abduction moment (KAM) is known to be a risk factor, it is unclear how cutting technique affects KAMs in sport-specific cutting maneuvers. Further, the effect of added game specificity (e.g., catching a ball or faking defenders) on KAMs and cutting technique remains unknown. Therefore, this study aimed: (i) to test if athletes grouped into different clusters of peak KAMs produced during three sport-specific fake-and-cut tasks of different complexities differ in cutting technique, and (ii) to test whether technique variables change with task complexity. Fifty-one female handball players (67.0 ± 7.7 kg, 1.70 ± 0.06 m, 19.2 ± 3.4 years) were recruited. Athletes performed at least five successful handball-specific sidestep cuts of three different complexities ranging from simple pre-planned fake-and-cut maneuvers to catching a ball and performing an unanticipated fake-and-cut maneuver with dynamic defenders. A k-means cluster algorithm with squared Euclidean distance metric was applied to the KAMs of all three tasks. The optimal cluster number of k optimal = 2 was calculated using the average silhouette width. Statistical differences in technique variables between the two clusters and the tasks were analyzed using repeated-measures ANOVAs (task complexity) with nested groupings (clusters). KAMs differed by 64.5%, on average, between clusters. When pooling all tasks, athletes with high KAMs showed 3.4° more knee valgus, 16.9% higher downward and 8.4% higher resultant velocity at initial ground contact, and 20.5% higher vertical ground reaction forces at peak KAM. Unlike most other variables, knee valgus angle was not affected by task complexity, likely due to it being part of inherent movement strategies and partly determined by anatomy. Since the high KAM cluster showed higher vertical center of mass excursions and knee valgus angles in all tasks, it is likely that this is part of an automated motor program developed over the players' careers. Based on these results, reducing knee valgus and downward velocity bears the potential to mitigate knee joint loading and therefore ACL injury risk.

13.
Sports Med Open ; 8(1): 125, 2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36219269

RESUMO

BACKGROUND: Many countries have restricted public life in order to contain the spread of the novel coronavirus (SARS-CoV2). As a side effect of related measures, physical activity (PA) levels may have decreased. OBJECTIVE: We aimed (1) to quantify changes in PA and (2) to identify variables potentially predicting PA reductions. METHODS: A systematic review with random-effects multilevel meta-analysis was performed, pooling the standardized mean differences in PA measures before and during public life restrictions. RESULTS: A total of 173 trials with moderate methodological quality (modified Downs and Black checklist) were identified. Compared to pre-pandemic, total PA (SMD - 0.65, 95% CI - 1.10 to - 0.21) and walking (SMD - 0.52, 95% CI - 0.29 to - 0.76) decreased while sedentary behavior increased (SMD 0.91, 95% CI: 0.17 to 1.65). Reductions in PA affected all intensities (light: SMD - 0.35, 95% CI - 0.09 to - 0.61, p = .013; moderate: SMD - 0.33, 95% CI - 0.02 to - 0.6; vigorous: SMD - 0.33, - 0.08 to - 0.58, 95% CI - 0.08 to - 0.58) to a similar degree. Moderator analyses revealed no influence of variables such as sex, age, body mass index, or health status. However, the only continent without a PA reduction was Australia and cross-sectional trials yielded higher effect sizes (p < .05). CONCLUSION: Public life restrictions associated with the COVID-19 pandemic resulted in moderate reductions in PA levels and large increases in sedentary behavior. Health professionals and policy makers should therefore join forces to develop strategies counteracting the adverse effects of inactivity.

14.
Bioengineering (Basel) ; 9(5)2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35621474

RESUMO

Real-time monitoring of bioanalytes in organotypic cell cultivation devices is a major research challenge in establishing stand-alone diagnostic systems. Presently, no general technical facility is available that offers a plug-in system for bioanalytics in diversely available organotypic culture models. Therefore, each analytical device has to be tuned according to the microfluidic and interface environment of the 3D in vitro system. Herein, we report the design and function of a 3D automated culture and analysis device (3D-ACAD) which actively perfuses a custom-made 3D microbioreactor, samples the culture medium and simultaneously performs capillary-based flow ELISA. A microstructured MatriGrid® has been explored as a 3D scaffold for culturing HepaRG cells, with albumin investigated as a bioanalytical marker using flow ELISA. We investigated the effect of acetaminophen (APAP) on the albumin secretion of HepaRG cells over 96 h and compared this with the albumin secretion of 2D monolayer HepaRG cultures. Automated on-line monitoring of albumin secretion in the 3D in vitro mode revealed that the application of hepatotoxic drug-like APAP results in decreased albumin secretion. Furthermore, a higher sensitivity of the HepaRG cell culture in the automated 3D-ACAD system to APAP was observed compared to HepaRG cells cultivated as a monolayer. The results support the use of the 3D-ACAD model as a stand-alone device, working in real time and capable of analyzing the condition of the cell culture by measuring a functional analyte. Information obtained from our system is compared with conventional cell culture and plate ELISA, the results of which are presented herein.

15.
Bioengineering (Basel) ; 9(5)2022 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-35621498

RESUMO

Recent trends in 3D cell culturing has placed organotypic tissue models at another level. Now, not only is the microenvironment at the cynosure of this research, but rather, microscopic geometrical parameters are also decisive for mimicking a tissue model. Over the years, technologies such as micromachining, 3D printing, and hydrogels are making the foundation of this field. However, mimicking the topography of a particular tissue-relevant substrate can be achieved relatively simply with so-called template or morphology transfer techniques. Over the last 15 years, in one such research venture, we have been investigating a micro thermoforming technique as a facile tool for generating bioinspired topographies. We call them MatriGrid®s. In this research account, we summarize our learning outcome from this technique in terms of the influence of 3D micro morphologies on different cell cultures that we have tested in our laboratory. An integral part of this research is the evolution of unavoidable aspects such as possible label-free sensing and fluidic automatization. The development in the research field is also documented in this account.

16.
Sports Med ; 52(8): 1863-1877, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35247202

RESUMO

BACKGROUND: Running overuse injuries (ROIs) occur within a complex, partly injury-specific interplay between training loads and extrinsic and intrinsic risk factors. Biomechanical risk factors (BRFs) are related to the individual running style. While BRFs have been reviewed regarding general ROI risk, no systematic review has addressed BRFs for specific ROIs using a standardized methodology. OBJECTIVE: To identify and evaluate the evidence for the most relevant BRFs for ROIs determined during running and to suggest future research directions. DESIGN: Systematic review considering prospective and retrospective studies. (PROSPERO_ID: 236,832). DATA SOURCES: PubMed. Connected Papers. The search was performed in February 2021. ELIGIBILITY CRITERIA: English language. Studies on participants whose primary sport is running addressing the risk for the seven most common ROIs and at least one kinematic, kinetic (including pressure measurements), or electromyographic BRF. A BRF needed to be identified in at least one prospective or two independent retrospective studies. BRFs needed to be determined during running. RESULTS: Sixty-six articles fulfilled our eligibility criteria. Levels of evidence for specific ROIs ranged from conflicting to moderate evidence. Running populations and methods applied varied considerably between studies. While some BRFs appeared for several ROIs, most BRFs were specific for a particular ROI. Most BRFs derived from lower-extremity joint kinematics and kinetics were located in the frontal and transverse planes of motion. Further, plantar pressure, vertical ground reaction force loading rate and free moment-related parameters were identified as kinetic BRFs. CONCLUSION: This study offers a comprehensive overview of BRFs for the most common ROIs, which might serve as a starting point to develop ROI-specific risk profiles of individual runners. We identified limited evidence for most ROI-specific risk factors, highlighting the need for performing further high-quality studies in the future. However, consensus on data collection standards (including the quantification of workload and stress tolerance variables and the reporting of injuries) is warranted.


Assuntos
Transtornos Traumáticos Cumulativos , Corrida , Fenômenos Biomecânicos , Coleta de Dados , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Corrida/lesões
17.
Sensors (Basel) ; 23(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36616946

RESUMO

Running stability is the ability to withstand naturally occurring minor perturbations during running. It is susceptible to external and internal running conditions such as footwear or fatigue. However, both its reliable measurability and the extent to which laboratory measurements reflect outdoor running remain unclear. This study aimed to evaluate the intra- and inter-day reliability of the running stability as well as the comparability of different laboratory and outdoor conditions. Competitive runners completed runs on a motorized treadmill in a research laboratory and overground both indoors and outdoors. Running stability was determined as the maximum short-term divergence exponent from the raw gyroscope signals of wearable sensors mounted to four different body locations (sternum, sacrum, tibia, and foot). Sacrum sensor measurements demonstrated the highest reliabilities (good to excellent; ICC = 0.85 to 0.91), while those of the tibia measurements showed the lowest (moderate to good; ICC = 0.55 to 0.89). Treadmill measurements depicted systematically lower values than both overground conditions for all sensor locations (relative bias = -9.8% to -2.9%). The two overground conditions, however, showed high agreement (relative bias = -0.3% to 0.5%; relative limits of agreement = 9.2% to 15.4%). Our results imply moderate to excellent reliability for both overground and treadmill running, which is the foundation of further research on running stability.


Assuntos
, Tíbia , Humanos , Reprodutibilidade dos Testes , Fenômenos Biomecânicos , Fadiga , Teste de Esforço/métodos , Marcha
18.
Sci Rep ; 11(1): 2244, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33500528

RESUMO

Treadmills are essential to the study of human and animal locomotion as well as for applied diagnostics in both sports and medicine. The quantification of relevant biomechanical and physiological variables requires a precise regulation of treadmill belt velocity (TBV). Here, we present a novel method for time-efficient tracking of TBV using standard 3D motion capture technology. Further, we analyzed TBV fluctuations of four different treadmills as seven participants walked and ran at target speeds ranging from 1.0 to 4.5 m/s. Using the novel method, we show that TBV regulation differs between treadmill types, and that certain features of TBV regulation are affected by the subjects' body mass and their locomotion speed. With higher body mass, the TBV reductions in the braking phase of stance became higher, even though this relationship differed between locomotion speeds and treadmill type (significant body mass × speed × treadmill type interaction). Average belt speeds varied between about 98 and 103% of the target speed. For three of the four treadmills, TBV reduction during the stance phase of running was more intense (> 5% target speed) and occurred earlier (before 50% of stance phase) unlike the typical overground center of mass velocity patterns reported in the literature. Overall, the results of this study emphasize the importance of monitoring TBV during locomotor research and applied diagnostics. We provide a novel method that is freely accessible on Matlab's file exchange server ("getBeltVelocity.m") allowing TBV tracking to become standard practice in locomotion research.

19.
J Biomech ; 95: 109311, 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31451201

RESUMO

Inverse dynamics is a standard tool in biomechanics, which requires low-pass filtering of external force and kinematic signals. Unmatched filtering procedures are reported to affect joint moment amplitudes in high impact movements, like landing or cutting, but are also common in the analysis of distance running. We analyzed the effects of cut-off frequencies in 94 rearfoot runners at a speed of 3.5 m/s. Additionally, we investigated whether the evaluation of footwear interventions is affected by the choice of cut-off frequencies. We performed 3D inverse dynamics for the hip, knee and ankle joints using different low-pass filter cut-off frequency combinations for a recursive fourth-order Butterworth filter. We observed fluctuations of joint moment curves in the first half of stance, which were most pronounced for the most unmatched cut-off frequency combination (kinematics: 10 Hz; ground reaction forces (GRFs): 100 Hz) and for more proximal joints. Peak sagittal plane hip joint moments were altered by 94% on average. We observed a change in the ranking of subjects based on joint moment amplitude. We found significant (p < 0.001) footwear by cut-off frequency combination interaction effects for most peak joint moments. These findings highlight the importance of cut-off frequency choice in the analysis of joint moments and the assessment of footwear interventions in distance running. Based on our results, we propose to use matched cut-off frequencies around 20 Hz in order to avoid large artificial fluctuations in joint moment curves while at the same time avoiding a severe removal of physiological high-frequency signal content from the GRF signals.


Assuntos
Extremidade Inferior/fisiologia , Fenômenos Mecânicos , Corrida/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Pé/fisiologia , Humanos , Articulações/fisiologia , Masculino
20.
R Soc Open Sci ; 5(7): 180207, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30109075

RESUMO

Donor-acceptor Stenhouse adducts (DASAs) are gaining attention from organic and material chemists due to their visible light-stimulated photochromic properties. In this report, we present a facile method for grafting coloured triene on polycarbonate surface, without involving any pre-treatments like plasma activation, etc. The chemoselectivity of carbonate with a primary amine and Meldrum's activated furan (MAF) with polymer bound secondary amine has been exploited to graft photoswitchable DASA on the polymer surface. Primary, secondary and tertiary amine-functionalized polycarbonate surfaces have been prepared to evaluate the reactivity of amine with MAF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...