Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Struct Dyn ; 2(4): 041701, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26798801

RESUMO

Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.

2.
Opt Express ; 21(13): 15102-12, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23842297

RESUMO

The structures of biological molecules may soon be determined with X-ray free-electron lasers without crystallization by recording the coherent diffraction patterns of many identical copies of a molecule. Most analysis methods require a measurement of each molecule individually. However, current injection methods deliver particles to the X-ray beam stochastically and the maximum yield of single particle measurements is 37% at optimal concentration. The remaining 63% of pulses intercept no particles or multiple particles. We demonstrate that in the latter case single particle diffraction patterns can be extracted provided the particles are sufficiently separated. The technique has the potential to greatly increase the amount of data available for three-dimensional imaging of identical particles with X-ray lasers.

3.
Opt Express ; 21(9): 11441-7, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23670000

RESUMO

We present single shot nanoscale imaging using a table-top femtosecond soft X-ray laser harmonic source at a wavelength of 32 nm. We show that the phase retrieval process in coherent diffractive imaging critically depends on beam quality. Coherence and image fidelity are measured from single-shot coherent diffraction patterns of isolated nano-patterned slits. Impact of flux, wave front and coherence of the soft X-ray beam on the phase retrieval process and the image quality are discussed. After beam improvements, a final image reconstruction is presented with a spatial resolution of 78 nm (half period) in a single 20 fs laser harmonic shot.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Nanopartículas/ultraestrutura , Difração de Raios X/métodos
4.
Nature ; 486(7404): 513-7, 2012 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-22739316

RESUMO

The morphology of micrometre-size particulate matter is of critical importance in fields ranging from toxicology to climate science, yet these properties are surprisingly difficult to measure in the particles' native environment. Electron microscopy requires collection of particles on a substrate; visible light scattering provides insufficient resolution; and X-ray synchrotron studies have been limited to ensembles of particles. Here we demonstrate an in situ method for imaging individual sub-micrometre particles to nanometre resolution in their native environment, using intense, coherent X-ray pulses from the Linac Coherent Light Source free-electron laser. We introduced individual aerosol particles into the pulsed X-ray beam, which is sufficiently intense that diffraction from individual particles can be measured for morphological analysis. At the same time, ion fragments ejected from the beam were analysed using mass spectrometry, to determine the composition of single aerosol particles. Our results show the extent of internal dilation symmetry of individual soot particles subject to non-equilibrium aggregation, and the surprisingly large variability in their fractal dimensions. More broadly, our methods can be extended to resolve both static and dynamic morphology of general ensembles of disordered particles. Such general morphology has implications in topics such as solvent accessibilities in proteins, vibrational energy transfer by the hydrodynamic interaction of amino acids, and large-scale production of nanoscale structures by flame synthesis.


Assuntos
Aerossóis/análise , Aerossóis/química , Fractais , Espectrometria de Massas , Movimento (Física) , Fuligem/análise , Fuligem/química , Aminoácidos/química , Elétrons , Lasers , Nanopartículas , Tamanho da Partícula , Proteínas/química , Solventes/química , Vibração , Difração de Raios X
5.
Opt Express ; 20(12): 13501-12, 2012 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-22714377

RESUMO

The emergence of femtosecond diffractive imaging with X-ray lasers has enabled pioneering structural studies of isolated particles, such as viruses, at nanometer length scales. However, the issue of missing low frequency data significantly limits the potential of X-ray lasers to reveal sub-nanometer details of micrometer-sized samples. We have developed a new technique of dark-field coherent diffractive imaging to simultaneously overcome the missing data issue and enable us to harness the unique contrast mechanisms available in dark-field microscopy. Images of airborne particulate matter (soot) up to two microns in length were obtained using single-shot diffraction patterns obtained at the Linac Coherent Light Source, four times the size of objects previously imaged in similar experiments. This technique opens the door to femtosecond diffractive imaging of a wide range of micrometer-sized materials that exhibit irreproducible complexity down to the nanoscale, including airborne particulate matter, small cells, bacteria and gold-labeled biological samples.


Assuntos
Elétrons , Imageamento Tridimensional/métodos , Lasers , Simulação por Computador , Microscopia Eletrônica de Transmissão , Fuligem/análise , Fatores de Tempo , Raios X
6.
Phys Rev Lett ; 104(22): 225501, 2010 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-20867179

RESUMO

We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.


Assuntos
Análise de Fourier , Imageamento Tridimensional/métodos , Espalhamento de Radiação , Tomografia/métodos , Estudos de Viabilidade , Compostos Férricos/química , Nanopartículas/química
7.
Phys Rev Lett ; 103(2): 028104, 2009 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-19659250

RESUMO

Coherent x-ray diffractive imaging is a powerful method for studies on nonperiodic structures on the nanoscale. Access to femtosecond dynamics in major physical, chemical, and biological processes requires single-shot diffraction data. Up to now, this has been limited to intense coherent pulses from a free electron laser. Here we show that laser-driven ultrashort x-ray sources offer a comparatively inexpensive alternative. We present measurements of single-shot diffraction patterns from isolated nano-objects with a single 20 fs pulse from a table-top high-harmonic x-ray laser. Images were reconstructed with a resolution of 119 nm from the single shot and 62 nm from multiple shots.


Assuntos
Difração de Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Lasers
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...