Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Klin Monbl Augenheilkd ; 233(8): 910-3, 2016 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-26854481

RESUMO

BACKGROUND: To evaluate the long-term outcome and complication rate after surgical posterior capsule polishing as an alternative to Nd : YAG-Laser posterior capsulotomy in the treatment of posterior capsule opacity after cataract extraction in eyes with high risk of developing pseudophakic retinal detachment. PATIENTS AND METHODS: This retrospective study comprised 265 eyes in 234 patients (134 women, 100 men, mean age: 61 years) with posterior capsule opacity who underwent surgical posterior capsule polishing between 1997 and 2010, with a follow-up of at least 12 months. RESULTS: Surgical posterior capsule polishing was performed in 220 myopic eyes (axial length > 25 mm), in 28 eyes after retinal detachment surgery and in 17 eyes with traumatic cataract. The mean follow-up was 73 months (range: 12 to 202 months); in 206 eyes (77.8 %), follow-up was more than 3 years. The final best-corrected visual acuity (BCVA) in logMAR (mean 0.56 ± 0.63) improved significantly (p < 0.001) compared to the preoperative BCVA (mean 0.93 ± 0.72). Recurrent posterior capsule opacity occurred in 74 eyes (27.9 %) and was treated by one or more surgical posterior capsule polishing procedures. Nd : YAG-Laser posterior capsulotomy was performed in 28 eyes (10.6 %) and surgical capsulectomy in 8 eyes (3.0 %). Complications after surgical posterior capsule polishing included intraoperative capsule rupture in 9 eyes (3.5 %). No postoperative endophthalmitis was observed. However, retinal detachment occurred in 6 eyes (2.3 %) 62 months after surgical posterior capsule polishing. All eyes were myopic (axial length > 25 mm) and initially vitrectomised during first retinal detachment surgery. CONCLUSIONS: Long-term outcome and complication rate indicate that surgical posterior capsule polishing is not only a more complex procedure but is also associated with a higher relapse risk than Nd : YAG-Laser posterior capsulotomy in the treatment of regenerative secondary cataract. Furthermore, conserving the posterior lens capsule does not always seem to minimise the cumulative risk of developing pseudophakic retinal detachment in high risk patients.


Assuntos
Opacificação da Cápsula/cirurgia , Miopia/epidemiologia , Cápsula Posterior do Cristalino/cirurgia , Complicações Pós-Operatórias/epidemiologia , Descolamento Retiniano/epidemiologia , Opacificação da Cápsula/epidemiologia , Opacificação da Cápsula/patologia , Causalidade , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Terapia a Laser/estatística & dados numéricos , Lasers de Estado Sólido/uso terapêutico , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Cápsula Posterior do Cristalino/patologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
2.
Klin Monbl Augenheilkd ; 232(10): 1198-207, 2015 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-26512851

RESUMO

BACKGROUND: To assess the outcome of routine trabectomy surgery in the treatment of primary (POAG) and secondary open angle glaucoma. PATIENTS/METHODS: 296 eyes of 296 patients with diagnosed open angle glaucoma and exfoliative glaucoma were analysed from June 2012 until June 2014. IOP readings (intraocular pressure) and the number of antiglaucoma medications was evaluated at every follow-up visit. For statistical analysis, 4 study cohorts were built (cohort 1 = trabectomy in POAG, cohort 2 = trabectomy in exfoliative glaucoma (PEX), cohort 3 = trabectomy + IOL in POAG, cohort 4 = trabectomy + IOL in PEX glaucoma). RESULTS: Mean IOP before trabectomy surgery was 19.8 ± 5.9 mmHg and 23.7 ± 9.5 mmHg in cohorts 1 and 2, respectively. At 1 year follow-up, IOP was reduced to normal level for cohorts 1 and 2 (14.8 ± 3.2 mmHg (p = 0.001) and 14.0 ± 3.3 mmHg (p = 0.046), respectively). The number of topical antiglaucoma medications changed to 2.1 ± 1.2 (p = 0.004) and 2.4 ± 1.2, respectively (p = 0.593) at one year follow-up, respectively, for POAG and exfoliative glaucoma. In study cohort 3 and 4, mean IOP before trabectomy surgery was 19.2 ± 4.0 mmHg and 23.2 ± 9.2 mmHg, respectively. At 1 year follow-up, IOP was reduced to normal levels in cohorts 3 and 4 (11.8 ± 3.1 mmHg (p < 0.01) and 12.6 ± 1.1 mmHg, respectively (p = 0.043)); the number of topical antiglaucoma medications changed to 2.3 ± 1.4 (p = 0.469) and 1.4 ± 0.8, respectively, (p = 0.102) at 1 year follow-up. A significant difference in IOP reduction could be demonstrated in POAG between the trabectomy + IOL group and the trabectomy cohort 1 year postoperative (p = 0.017); in the PEX trabectomy + IOL versus PEX trabectomy cohort no statistically significant difference (p = 0.678) could be demonstrated. No serious postoperative complications were recorded. CONCLUSION: Trabectomy surgery seemed to be a reliable and effective tool for the management of mild and moderate primary and secondary open angle glaucoma with uncontrolled IOP in daily routine. One year follow-up showed a significant reduction in intraocular pressure in all cohorts.


Assuntos
Síndrome de Exfoliação/diagnóstico , Síndrome de Exfoliação/cirurgia , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Trabeculectomia/instrumentação , Trabeculectomia/métodos , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
3.
Eye (Lond) ; 29(10): 1335-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26139050

RESUMO

PURPOSE: To assess the outcome of trabectome surgery in the treatment of glaucomatocyclitic crisis (Posner-Schlossman syndrome) in patients with uncontrolled intraocular pressure (IOP). PATIENTS/METHODS: Trabectome surgery was performed in seven patients with diagnosed glaucomatocyclitic crisis and uncontrolled IOP where cytomegalovirus DNA was verified by polymerase chain reaction in aqueous humour samples. All patients were treated with oral valganciclovir. After surgery the patients were followed-up for 12 months. RESULTS: Mean IOP before trabectome surgery was 40±10 mm Hg (range 33-58 mm Hg). The mean number of antiglaucoma medication prior to surgery was 3.1±0.4. By the end of the 12 months, IOP in all patients was reduced to normal level (13±1 mm Hg) and their antiglaucoma medication was decreased to 0.8±1.1. No recurring attack of glaucomatocyclitic crisis occurred. DISCUSSION: In addition to oral valganciclovir therapy, trabectome surgery seems to be a reliable and effective tool for the management of glaucomatocyclitic crisis with uncontrolled IOP.


Assuntos
Antivirais/uso terapêutico , Infecções por Citomegalovirus/terapia , Infecções Oculares Virais/terapia , Ganciclovir/análogos & derivados , Glaucoma/terapia , Iridociclite/terapia , Trabeculectomia/métodos , Administração Oral , Adulto , Idoso , Terapia Combinada , Citomegalovirus/genética , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , DNA Viral/genética , Infecções Oculares Virais/diagnóstico , Infecções Oculares Virais/virologia , Feminino , Ganciclovir/uso terapêutico , Glaucoma/diagnóstico , Glaucoma/virologia , Humanos , Pressão Intraocular , Iridociclite/diagnóstico , Iridociclite/virologia , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Estudos Retrospectivos , Malha Trabecular/cirurgia , Valganciclovir
4.
Eye (Lond) ; 29(3): 327-32, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25412715

RESUMO

PURPOSE: In this retrospective study, the visual outcomes and postoperative complications after Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK) in the fellow eye were compared. The patient's satisfaction was evaluated. METHODS: A retrospective analysis of 10 patients, who underwent DSAEK in one eye and DMEK surgery in their fellow eye, was performed. Intraoperative and postoperative complications were recorded. Visual and refractive outcomes were evaluated, including higher-order aberrations (HOA) and contrast thresholds. A subjective questionnaire was used to evaluate patient satisfaction. RESULTS: Best-corrected visual acuity (BCVA) was significantly better in DMEK when compared with DSAEK (0.16±0.10 vs 0.45±0.58 logMAR, P=0.043). Contrast threshold was significantly higher after DMEK than after DSAEK (0.49±0.23 vs 0.25±0.18, P=0.043). Post-keratoplasty astigmatism, mean spherical equivalent, and HOA did not differ. Nine out of ten patients preferred the DMEK procedure. Visual outcome (4.80±1.14 vs 4.50±1.58, P=0.257), surgery associated pain and burden (DMEK: 1.30±0.48 vs DSAEK: 1.30±0.48, P=1.0), estimated time for recovery and rehabilitation (27.6±54.0 vs 24.9±54.8 days, P=0.173), and mean patient satisfaction (5.40±0.84 vs 5.00±1.05, P=0.257) were evaluated equally. CONCLUSION: Patient satisfaction reached high, equal values after DMEK and after DSAEK. Nevertheless, patients preferred DMEK, if given a choice. Reasons for the preference may include better uncorrected and BCVA, and especially a better contrast sensitivity.


Assuntos
Doenças da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Satisfação do Paciente , Complicações Pós-Operatórias , Acuidade Visual/fisiologia , Idoso , Lâmina Limitante Posterior/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Inquéritos e Questionários
5.
Klin Monbl Augenheilkd ; 231(11): 1107-13, 2014 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-25419668

RESUMO

INTRODUCTION: The aim of this study was to compare the dynamic contour tonometry PASCAL® (DCT) versus the Goldmann applanation tonometry (GAT) in a glaucoma population and to analyse the correlation with the central corneal thickness (CCT). PATIENTS/METHODS: 191 eyes of 107 Caucasian glaucoma patients (62 female, 45 male) were included: 3 repeated GAT and dynamic contour tonometry (DCT) measurements (quality factor 1-2) were analysed. CCT was measured by ultrasound pachymetry. Criteria of ISO 8612 were fulfilled: 3 groups of IOP measurements were formed: group 1: 7-16 mmHg, group 2: 16-23 mmHg and group 3: > 23 mmHg, each including at least 40 eyes. Only 5.0 % outliers per area of intraocular pressure were permitted in a tolerance of ± 5.0 mmHg. RESULTS: Data of 191 eyes (mean CCT 553 µm) were analysed. GAT (19.68 mmHg ± 7.56 mmHg) showed good correlation to DCT (20.54 ± 8.21 mmHg) (r = 0.770, p < 0.001). Mean difference DCT-GAT was 0.86 ± 2.45 mmHg. In regard to the criteria of ISO 8612, the number of outliers were: group 1: (n = 68) 29.4 %, group 2: (n = 62) 41.9 %, and group 3: (n = 61) 31.2 %. No correlation was shown between CCT vs. GAT (r = 0.184, p = 0.057) and CCT vs. DCT (r = 0.177, p = 0.09), respectively. DISCUSSION: In conclusion, despite good correlation to GAT measurements DCT does not fulfil the ISO 8612 reference criteria in glaucoma patients. DCT and GAT did not show correlation to CCT.


Assuntos
Glaucoma/diagnóstico , Manometria/métodos , Manometria/normas , Hipertensão Ocular/diagnóstico , Oftalmologia/normas , Feminino , Glaucoma/complicações , Humanos , Internacionalidade , Masculino , Manometria/instrumentação , Hipertensão Ocular/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Klin Monbl Augenheilkd ; 231(8): 784-7, 2014 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-24992236

RESUMO

BACKGROUND: The aim of this study was to evaluate the indication, visual and refractive outcome, endothelial cell loss and complication rate after implantation of a posterior iris-claw aphakic intraocular lens (IOL). PATIENTS AND METHODS: This retrospective study comprised 62 eyes of 56 patients without adequate capsular support undergoing posterior iris-claw aphakic IOL implantation (Verisyse™/Artisan®) between 2006 and 2012. Mean follow-up was 34 months (range from 13 to 78 months). RESULTS: The IOLs were inserted during primary lens surgery in 11 phakic eyes (17.8 %), during an IOL exchange procedure for dislocated posterior chamber IOLs in 34 eyes (54.8 %), and as a secondary procedure in 17 aphakic eyes (27.4 %). The final best spectacle-corrected visual acuity (BSCVA) in logMAR (mean 0.24 ± 0.45) improved significantly (p < 0.001) compared to the preoperative BSCVA (mean 0.61 ± 0.65). The mean spherical equivalent improved from preoperative 7,25 ± 5,04 diopters (D) (range - 10.25 to + 16.0 D) to - 0.21 ± 1.01 D (range - 4.0 to 3.0 D) postoperatively. Mean central endothelial cell density was 1844 ± 690 cells/mm(2) preoperatively. After surgery mean endothelial cell density decreased statistically not significant with a loss of 5.5 % to 1743 ± 721 cells/mm(2) (p > 0.05) at last follow-up visit. Complications included cystoid macular oedema in 4 eyes (6.4 %), early postoperative hypotony in 2 eyes (3.2 %), pupil ovalisation in 2 eyes (3.2 %), traumatic iris-claw IOL disenclavation in 2 eyes (3.2 %) and spontaneous IOL disenclavation in one eye (1.6 %). CONCLUSIONS: Retropupillar iris-claw IOL provides good visual and refractive outcomes with a low endothelial cell loss and can be used for a wide range of indications in eyes without adequate capsular support.


Assuntos
Perda de Células Endoteliais da Córnea/etiologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Afacia Pós-Catarata/diagnóstico , Afacia Pós-Catarata/etiologia , Afacia Pós-Catarata/cirurgia , Contagem de Células , Perda de Células Endoteliais da Córnea/diagnóstico , Endotélio Corneano/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Desenho de Prótese , Refração Ocular , Estudos Retrospectivos , Acuidade Visual , Adulto Jovem
7.
Phys Med Biol ; 59(12): 3121-38, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24840084

RESUMO

The acquisition of data for cardiac imaging using a C-arm computed tomography system requires several seconds and multiple heartbeats. Hence, incorporation of motion correction in the reconstruction step may improve the resulting image quality. Cardiac motion can be estimated by deformable three-dimensional (3D)/3D registration performed on initial 3D images of different heart phases. This motion information can be used for a motion-compensated reconstruction allowing the use of all acquired data for image reconstruction. However, the result of the registration procedure and hence the estimated deformations are influenced by the quality of the initial 3D images. In this paper, the sensitivity of the 3D/3D registration step to the image quality of the initial images is studied. Different reconstruction algorithms are evaluated for a recently proposed cardiac C-arm CT acquisition protocol. The initial 3D images are all based on retrospective electrocardiogram (ECG)-gated data. ECG-gating of data from a single C-arm rotation provides only a few projections per heart phase for image reconstruction. This view sparsity leads to prominent streak artefacts and a poor signal to noise ratio. Five different initial image reconstructions are evaluated: (1) cone beam filtered-backprojection (FDK), (2) cone beam filtered-backprojection and an additional bilateral filter (FFDK), (3) removal of the shadow of dense objects (catheter, pacing electrode, etc) before reconstruction with a cone beam filtered-backprojection (cathFDK), (4) removal of the shadow of dense objects before reconstruction with a cone beam filtered-backprojection and a bilateral filter (cathFFDK). The last method (5) is an iterative few-view reconstruction (FV), the prior image constrained compressed sensing combined with the improved total variation algorithm. All reconstructions are investigated with respect to the final motion-compensated reconstruction quality. The algorithms were tested on a mathematical phantom data set with and without a catheter and on two porcine models using qualitative and quantitative measures. The quantitative results of the phantom experiments show that if no dense object is present within the scan field of view, the quality of the FDK initial images is sufficient for motion estimation via 3D/3D registration. When a catheter or pacing electrode is present, the shadow of these objects needs to be removed before the initial image reconstruction. An additional bilateral filter shows no major improvement with respect to the final motion-compensated reconstruction quality. The results with respect to image quality of the cathFDK, cathFFDK and FV images are comparable. In conclusion, in terms of computational complexity, the algorithm of choice is the cathFDK algorithm.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico/métodos , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento Tridimensional/métodos , Movimento , Animais , Técnicas de Imagem de Sincronização Cardíaca , Imagens de Fantasmas , Suínos
8.
J Tissue Eng Regen Med ; 8(3): 176-85, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22740314

RESUMO

Bone tissue engineering strategies mainly depend on porous scaffold materials. In this study, novel biphasic calcium phosphate (BCP) matrices were generated by 3D-printing. High porosity was achieved by starch consolidation. This study aimed to characterise the porous BCP-scaffold properties and interactions of osteogenic cells and growth factors under in vivo conditions. Five differently treated constructs were implanted subcutaneously in syngeneic rats: plain BCP constructs (group A), constructs pre-treated with BMP-2 (group B; 1.6 µg BMP-2 per scaffold), seeded with primary osteoblasts (OB) (group C), seeded with OB and BMP-2 (group D) and constructs seeded with OB and pre-cultivated in a flow bioreactor for 6 weeks (group E). After 2, 4 and 6 weeks, specimens were explanted and subjected to histological and molecular biological analyses. Explanted scaffolds were invaded by fibrovascular tissue without significant foreign body reactions. Morphometric analysis demonstrated significantly increased bone formation in samples from group D (OB + BMP-2) compared to all other groups. Samples from groups B-E displayed significant mRNA expression of bone-specific genes after 6 weeks. Pre-cultivation in the flow bioreactor (group E) induced bone formation comparable with group B. In this study, differences in bone distribution between samples with BMP-2 or osteoblasts could be observed. In conclusion, combination of osteoblasts and BMP-2 synergistically enhanced bone formation in novel ceramic scaffolds. These results provide the basis for further experiments in orthotopic defect models with a focus on future applications in orthopaedic and reconstructive surgery.


Assuntos
Proteína Morfogenética Óssea 2/farmacologia , Fosfatos de Cálcio/química , Hidroxiapatitas/química , Osteoblastos/citologia , Animais , Materiais Biocompatíveis/química , Reatores Biológicos , Células da Medula Óssea/citologia , Osso e Ossos , Durapatita/química , Masculino , Osteogênese , Perfusão , Porosidade , RNA Mensageiro/metabolismo , Ratos , Ratos Endogâmicos Lew , Engenharia Tecidual , Alicerces Teciduais , Microtomografia por Raio-X
9.
Ophthalmologe ; 111(2): 128-34, 2014 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-23575642

RESUMO

BACKGROUND: The aim of this study was to evaluate the effect of donor lamella thickness on postoperative visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK). MATERIALS AND METHODS: A retrospective analysis of 65 eyes from 61 patients who underwent DSAEK surgery in cases of Fuchs' corneal dystrophy or bullous keratopathy between 2008 and 2011 was performed. The thickness of donor lamella was measured intraoperatively by ultrasonic pachymetry and postoperatively by anterior segment optical coherence tomography (OCT) and correlated to the visual acuity and number of endothelial cells. RESULTS: The donor lamella thickness measured intraoperatively and postoperatively correlated significantly with each other (r = 0.874, p < 0.001). A significant correlation was found between postoperative corneal lamella thickness measured by anterior segment OCT and visual acuity (r = 0.273, p = 0.028) but not between intraoperative donor lamella thickness measured by ultrasonic pachymetry and visual acuity (r = 0.241, p = 0.103). The postoperative endothelial cell number did not show a correlation with either the intraoperatively or the postoperatively measured donor lamella thickness (r = - 0.059, p = 0.731, r = 0.024, p = 0.869, respectively). CONCLUSIONS: Corneal lamella thickness < 120 µm was found to be correlated with a better visual outcome than in cases of thicker corneas > 120 µm. Despite greater difficulty in corneal transplant technique in cases of thinner lamella no increased damage of corneal endothelium was shown. Therefore, DSAEK with corneal lamella thickness < 120 µm is an interesting therapeutic alternative to DMEK.


Assuntos
Doenças da Córnea/diagnóstico , Doenças da Córnea/cirurgia , Lâmina Limitante Posterior/patologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Transtornos da Visão/diagnóstico , Transtornos da Visão/prevenção & controle , Acuidade Visual , Idoso , Doenças da Córnea/complicações , Lâmina Limitante Posterior/cirurgia , Feminino , Humanos , Masculino , Doadores de Tecidos , Resultado do Tratamento , Transtornos da Visão/etiologia
10.
Klin Monbl Augenheilkd ; 230(10): 1029-33, 2013 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-23757169

RESUMO

BACKGROUND: The aim of this study was to investigate the influence of the anterior chamber depth (ACD) on the measurement of the optic nerve head size with OCT and HRT 3. PATIENTS AND METHODS: 100 pseudophakic eyes of 100 patients were enrolled in this prospective study. The measurement of the optic nerve head was performed with the optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc., Dublin, CA) and the confocal laser scanning tomography (Heidelberg retina tomograph, HRT 3, Heidelberg Engineering, GmbH, Dossenheim, Germany). Bland and Altman plots were used to examine the agreement between the parameters of the two techniques. The relationship between the optic nerve head size and the ACD was analysed by linear regression. RESULTS: Optic disc size measurement with the OCT and the HRT 3 showed no significant difference (p = 0.638). Measurement of the optic disc size with the OCT was significantly correlated with the ACD (- 0.234; p = 0.016). The optic disc size decreases with increasing values of the ACD. There was no influence of the ACD on the measurement of the optic disc size with the HRT 3 (r = 0.128; p = 0.193). CONCLUSION: While the optic disc size measured by OCT decreased with increasing ACD, the measurement with the HRT 3 turned out to be independent of the ACD. The OCT may underestimate the optic disc size in lower ACD. This may result in reduced agreement between the two devices.


Assuntos
Câmara Anterior/anatomia & histologia , Microscopia Confocal/instrumentação , Microscopia Confocal/métodos , Disco Óptico/anatomia & histologia , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Artefatos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Klin Monbl Augenheilkd ; 230(7): 697-700, 2013 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-23670524

RESUMO

BACKGROUND: The aim of this study was to evaluate the effect of central corneal thickness (CCT) of keratoconic corneas on intraocular pressure (IOP) measurements as measured by four different techniques. PATIENTS AND METHODS: Forty-one eyes of forty-one keratoconus patients (group 1) and fifty eyes of fifty healthy subjects (group 2) were enrolled. IOP was measured with iCare, IOPen, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT). CCT was measured by ultrasonic pachymetry. These data were used for statistical analysis. RESULTS: The mean IOPs measured by GAT, DCT, iCare and IOPen were 11.4, 14.7, 10.8, and 15.7 mmHg in group 1; and 14.2, 15.4, 15.4 and 14.3 mmHg in group 2, respectively. Between both groups, there was a statistically significant difference in iCare (p < 0.001), GAT (p < 0.001) and IOPen (p = 0.040) measurements; with no difference between DCT (p = 0.266) measurements. IOPen measurements were significantly associated with CCT (r = - 0.314; p = 0.046). CONCLUSION: IOPen seemed to be affected by CCT. IOP readings by iCare, GAT and DCT were found to be independent of CCT in keratoconic corneas.


Assuntos
Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Pressão Intraocular , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Manometria/métodos , Ultrassonografia/métodos , Adulto , Topografia da Córnea/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Ophthalmic Res ; 49(4): 192-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23306647

RESUMO

PURPOSE: To evaluate the diagnostic value of microperimetry (MP), blue-on-yellow perimetry (B/YP), confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph, HRT, III) and optical coherence tomography (OCT) in discriminating eyes with early glaucoma from healthy subjects. MATERIAL AND METHODS: Prospective examination of 22 eyes of subjects with early primary open-angle glaucoma and 24 eyes of healthy control subjects. After a complete ophthalmological examination, B/YP, MP, OCT and HRT III were determined. Morphological and functional parameters were analysed. RESULTS: Mean sensitivity threshold values obtained with B/YP and MP did not show significant differences between glaucoma patients and the control group (p = 0.321 and p = 0.281). Retinal nerve fibre layer (RNFL) thickness was significantly decreased in patients with glaucoma with both HRT III and OCT (p = 0.018 and p < 0.001). CONCLUSIONS: While B/YP and MP had no ability to discriminate between subjects with early glaucoma and healthy subjects, RNFL thickness measured with HRT III and OCT showed a significant difference. In early primary open-angle glaucoma, morphological changes like RNFL thickness seem to occur prior to functional defects in the visual field.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Fibras Nervosas/patologia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Testes de Campo Visual
13.
Ophthalmologe ; 109(11): 1093-7, 2012 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-22752628

RESUMO

BACKGROUND: The aim of this study was to evaluate the effect of increased corneal thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) on intraocular pressure (IOP) measured by four different techniques. METHODS: In this study 30 eyes from 30 patients with successful DSAEK treatment (group 1) and 30 eyes of 30 healthy subjects (group 2) were enrolled. The IOP was measured with iCare, IOPen, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) techniques. Central corneal thickness (CCT) was measured by ultrasonic pachymetry. These data were used for statistical analysis. RESULTS: The mean IOP measured by GAT, DCT, iCare and IOPen was 13.2, 16.1, 12.5 and 14.2 mmHg in group 1 and 13.4, 14.4, 14.4 and 13.3 mmHg in group 2, respectively. Correlations between IOP and CCT were not statistically significant in either group. CONCLUSION: The results of IOP measurements by the iCare, IOPen, GAT and DCT techniques seem to be unrelated to artificially thickened corneas after DSAEK. In spite of partially good correlation between the four techniques a direct exchange of the devices is not recommended on account of the wide dispersion of values.


Assuntos
Córnea/fisiopatologia , Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Pressão Intraocular , Tonometria Ocular/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Manometria , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Ophthalmologe ; 108(10): 966-8, 2011 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-21853218

RESUMO

Paecilomyces lilacinus is a rare cause of contact lens-associated keratitis. The infection is difficult to eradicate because of multiple antifungal drug resistance and has a poor outcome. A female patient developed contact lens-associated keratitis and Paecilomyces lilacinus could be demonstrated in the corneal abrasion. Despite antifungal therapy with voriconazole a keratoplasty à chaud was necessary and a poor final visual acuity could not be avoided.


Assuntos
Lentes de Contato/efeitos adversos , Lentes de Contato/microbiologia , Infecções Oculares Fúngicas/etiologia , Infecções Oculares Fúngicas/terapia , Ceratite/microbiologia , Ceratite/terapia , Paecilomyces , Adulto , Antifúngicos/uso terapêutico , Infecções Oculares Fúngicas/microbiologia , Feminino , Humanos , Ceratite/diagnóstico , Procedimentos Cirúrgicos Oftalmológicos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Falha de Tratamento
15.
Klin Monbl Augenheilkd ; 228(6): 515-9, 2011 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-21656434

RESUMO

Temperature is one of the fundamental characteristics of tissue metabolism and is certainly of major interest to investigate ocular physiology. Current instrumentation offers the potential to measure the ocular surface temperature (OST) with high accuracy and resolution. Potential applications of OST measurement may include any condition of the ocular surface. The present study gives a survey of the possible applications of thermography and describes our first experience with the new Tomey TG 1000.


Assuntos
Doenças da Córnea/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Termografia/instrumentação , Termografia/métodos , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...