Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Magn Reson Med ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703028

RESUMO

PURPOSE: In this work, the use of joint Total Generalized Variation (TGV) regularization to improve Multipool-Lorentzian fitting of chemical exchange saturation transfer (CEST) Spectra in terms of stability and parameter signal-to-noise ratio (SNR) was investigated. THEORY AND METHODS: The joint TGV term was integrated into the nonlinear parameter fitting problem. To increase convergence and weight the gradients, preconditioning using a voxel-wise singular value decomposition was applied to the problem, which was then solved using the iteratively regularized Gauss-Newton method combined with a Primal-Dual splitting algorithm. The TGV method was evaluated on simulated numerical phantoms, 3T phantom data and 7T in vivo data with respect to systematic errors and robustness. Three reference methods were also implemented: The standard nonlinear fitting, a method using a nonlocal-means filter for denoising and the pyramid scheme, which uses downsampled images to acquire accurate start values. RESULTS: The proposed regularized fitting method showed significantly improved robustness (compared to the reference methods). In testing, over a range of SNR values the TGV fit outperformed the other methods and showed accurate results even for large amounts of added noise. Parameter values found were closer or comparable to the ground truth. For in vivo datasets, the added regularization increased the parameter map SNR and prevented instabilities. CONCLUSION: The proposed fitting method using TGV regularization leads to improved results over a range of different data-sets and noise levels. Furthermore, it can be applied to all Z-spectrum data, with different amounts of pools, where the improved SNR and stability can increase diagnostic confidence.

2.
Front Cardiovasc Med ; 11: 1328906, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596690

RESUMO

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures. Methods: Ten patients scheduled for interventional LAA closure were evaluated with MSCT and TEE. Patient-specific 3D printings and VR models were fabricated based on MSCT data. Ten cardiologists then comparatively assessed LAA anatomy and its procedure relevant surrounding structures with all four imaging modalities and rated their procedural utility on a 5-point Likert scale questionnaire (from 1 = strongly agree to 5 = strongly disagree). Results: Device sizing was rated highest in MSCT (MSCT: 1.9 ± 0.8; TEE: 2.6 ± 0.9; 3D printing: 2.5 ± 1.0; VR: 2.5 ± 1.1; p < 0.01); TEE, VR, and 3D printing were superior in the visualization of the Fossa ovalis compared to MSCT (MSCT: 3.3 ± 1.4; TEE: 2.2 ± 1.3; 3D printing: 2.2 ± 1.4; VR: 1.9 ± 1.3; all p < 0.01). The major strength of VR and 3D printing techniques was a superior depth perception (VR: 1.6 ± 0.5; 3D printing: 1.8 ± 0.4; TEE: 2.9 ± 0.7; MSCT: 2.6 ± 0.8; p < 0.01). The visualization of extracardiac structures was rated less accurate in TEE than MSCT (TEE: 2.6 ± 0.9; MSCT: 1.9 ± 0.8, p < 0.01). However, 3D printing and VR insufficiently visualized extracardiac structures in the present study. Conclusion: A true 3D visualization in VR or 3D printing provides an additional value in the evaluation of the LAA for the planning of percutaneous closure. In particular, the superior perception of depth was seen as a strength of a 3D visualization. This may contribute to a better overall understanding of the anatomy. Clinical studies are needed to evaluate whether a more comprehensive understanding through advanced multimodal imaging of patient-specific anatomy using VR may translate into improved procedural outcomes.

3.
Interv Cardiol ; 19: e01, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464494

RESUMO

Optimised implantation depth (OID) is crucial to obtain the best haemodynamic and clinical outcome during transcatheter heart valve (THV) deployment. OID ensures a better haemodynamic profile and is associated with a potential reduction in permanent pacemaker implantations, both of which are important during transcatheter aortic valve replacement (TAVR). Apart from patient-related anatomic conditions, many factors, such as THV and wire selection, as well as implantation strategies, can be controlled by the operator and facilitate the implantation process. However, there are only limited data dealing with predictors for OID. Therefore, the aim of this review was to outline factors and tools that might influence the final implantation depth during TAVR procedures, potentially influencing the outcome.

4.
Stroke ; 55(4): 1006-1014, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38445467

RESUMO

BACKGROUND: Inflammatory type focal cerebral arteriopathy (FCA-i) in the anterior circulation (AC) is well characterized, and the focal cerebral arteriopathy severity score (FCASS) reflects the severity of the disease. We identified cases of FCA-i in the posterior circulation (PC) and adapted the FCASS to describe these cases. METHODS: In this comparative cohort study, patients from the Swiss NeuroPaediatric Stroke Registry with ischemic stroke due to FCA-i between January 2000 and December 2018 were analyzed. A comparison between PC and AC cases regarding pediatric National Institutes of Health Stroke Scale score and pediatric stroke outcome measure and FCASS was performed. We estimated infarct size by the modified pediatric Alberta Stroke Program Early Computed Tomography Score in children with AC stroke and the adapted Bernese posterior diffusion-weighted imaging score in the PC. RESULTS: Thirty-five children with a median age of 6.3 (interquartile range, 2.7-8.2 [95% CI, 0.9-15.6]; 20 male; 57.1%) years with FCA-i were identified. The total incidence rate was 0.15/100 000/year (95% CI, 0.11-0.21). Six had PC-FCA-i. Time to final FCASS was longer in the PC compared with AC; the evolution of FCASS did not differ. Initial pediatric National Institutes of Health Stroke Scale score was higher in children with FCA-i in the PC with a median of 10.0 (interquartile range, 5.75-21.0) compared with 4.5 (interquartile range, 2.0-8.0) in those with AC-FCA-i. Different from the anterior cases, PC infarct volume did not correlate with higher discharge, maximum, or final FCASS scores (Pearson correlation coefficient [r], 0.25, 0.35, and 0.54). CONCLUSIONS: FCA-i also affects the PC. These cases should be included in future investigations into FCA-i. Although it did not correlate with clinical outcomes in our cohort, the modified FCASS may well serve as a marker for the evolution of the arteriopathy in posterior FCA-i.


Assuntos
Doenças Arteriais Cerebrais , Transtornos Cerebrovasculares , Acidente Vascular Cerebral , Humanos , Criança , Masculino , Estudos de Coortes , Transtornos Cerebrovasculares/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Doenças Arteriais Cerebrais/diagnóstico por imagem , Doenças Arteriais Cerebrais/epidemiologia , Doenças Arteriais Cerebrais/complicações , Infarto
5.
EMBO Rep ; 25(3): 1106-1129, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38308064

RESUMO

Herpesviruses modulate immune control to secure lifelong infection. The mechanisms Human Cytomegalovirus (HCMV) employs in this regard can reveal unanticipated aspects of cellular signaling involved in antiviral immunity. Here, we describe a novel relationship between the TGF-ß family cytokine BMP9 and HCMV infection. We identify a cross-talk between BMP9-induced and IFN receptor-mediated signaling, showing that BMP9 boosts the transcriptional response to and antiviral activity of IFNß, thereby enhancing viral restriction. We also show that BMP9 is secreted by human fibroblasts upon HCMV infection. However, HCMV infection impairs BMP9-induced enhancement of the IFNß response, indicating that this signaling role of BMP9 is actively targeted by HCMV. Indeed, transmembrane proteins US18 and US20, which downregulate type I BMP receptors, are necessary and sufficient to cause inhibition of BMP9-mediated boosting of the antiviral response to IFNß. HCMV lacking US18 and US20 is more sensitive to IFNß. Thus, HCMV has a mutually antagonistic relationship with BMP9, which extends the growing body of evidence that BMP signaling is an underappreciated modulator of innate immunity in response to viral infection.


Assuntos
Fator 2 de Diferenciação de Crescimento , Imunidade Inata , Humanos , Citocinas/metabolismo , Citomegalovirus/metabolismo , Fator 2 de Diferenciação de Crescimento/metabolismo , Transdução de Sinais
6.
Front Cardiovasc Med ; 10: 1188571, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727301

RESUMO

Background and aims: The complex and highly variable three-dimensional anatomy of the left atrial appendage (LAA) makes planning and device sizing for interventional occlusion procedures (LAAC) challenging. Several imaging modalities [e.g. echocardiography, multi-slice computed tomography (MSCT)] are used for this purpose. Virtual reality (VR) is an emerging imaging technique to immerse into a three-dimensional left atrium and appendage, offering unprecedented options of visualization and measurement. This study aimed to investigate the feasibility, accuracy and reproducibility of visualizing the LAA in VR for preprocedural planning of LAAC. Methods and results: Twenty-one patients (79 ± 7 years, 62% male) who underwent LAAC at University Hospital Düsseldorf were included in our study. A dedicated software generated three-dimensional VR models from preprocedural MSCT imaging data. Conventional measurements of LAA dimensions (ostium, landing zone and depth) using a commercially available software were compared to measurements in VR: MSCT and VR ostium min. (r = 0.93), max. (r = 0.80) and mean (r = 0.88, all p < 0.001) diameters as well as landing zone (LZ) min. (r = 0.84), max. (r = 0.86) and mean diameters (r = 0.90, all p < 0.001) showed strong correlations. Three-dimensional orientation was judged superior by physicians in VR compared to MSCT (p < 0.05). Conclusion: Virtual reality visualization of the left atrium and appendage based on MSCT data is feasible and allows precise and reproducible measurements in planning of LAA occlusion procedures with enhanced 3D orientation. Further studies need to explore additional benefits of three-dimensional visualization for operators in preprocedural planning.

7.
Am J Cardiol ; 197: 87-92, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37137798

RESUMO

Sex-specific thresholds of aortic valve calcification (AVC) correlate with aortic stenosis (AS) and may complement echocardiography to determine AS severity. Importantly, current guideline-recommended thresholds of AVC scores derived by multislice computed tomography do not distinguish between bicuspid and tricuspid aortic valves. The objective of this study was to evaluate the sex-specific differences in the amount of AVC in patients with severe AS and tricuspid (TAV) versus bicuspid (BAV) aortic valve morphologies, retrospectively evaluated by 2 tertiary care institutions. The inclusion criteria comprised patients with severe AS and a left ventricular ejection fraction ≥50% and suitable imaging examinations. The study included 1,450 patients (723 men; 49.9%) with severe AS, including 1,335 patients with TAV (92.1%) and 115 with BAV (17.9%). The calculated Agatston score was higher in BAV patients (men: BAV 4,358 [2,644 to 6,005] AU vs TAV 2,643 [1,727 to 3,794] AU, p <0.01; women: BAV 2,174 [1,330 to 4,378] AU vs TAV 1,703 [964 to 2,534] AU, p <0.01), also when indexed for valve dimensions and body surface area (men: BAV 2,227 [321 to 3,105] AU/m2 vs TAV 1,333 [872 to 1,913] AU/m2, p <0.01; women: BAV 1,326 [782 to 2,148] AU/m2 vs TAV 930 [546 to 1,456] AU/m2, p <0.01). Differences between the BAV- and TAV-derived Agatston score was more prominent in concordant severe AS. In conclusion, sex-specific Agatston scores in severe AS were approximately 1/3 higher in patients with BAV than in patients with TAV for both women and men. Optimal AVC thresholds should be adjusted for BAV, also respecting considerable prognostic implications.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Masculino , Humanos , Feminino , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem
8.
Nanomaterials (Basel) ; 13(9)2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37177101

RESUMO

Structural anti-reflective coating and bactericidal surfaces, as well as many other effects, rely on high-aspect-ratio (HAR) micro- and nanostructures, and thus, are of great interest for a wide range of applications. To date, there is no widespread fabrication of dense or isolated HAR nanopillars based on UV nanoimprint lithography (UV-NIL). In addition, little research on fabricating isolated HAR nanopillars via UV-NIL exists. In this work, we investigated the mastering and replication of HAR nanopillars with the smallest possible diameters for dense and isolated arrangements. For this purpose, a UV-based nanoimprint lithography process was developed. Stability investigations with capillary forces were performed and compared with simulations. Finally, strategies were developed in order to increase the stability of imprinted nanopillars or to convert them into nanoelectrodes. We present UV-NIL replication of pillars with aspect ratios reaching up to 15 with tip diameters down to 35 nm for the first time. We show that the stability could be increased by a factor of 58 when coating them with a 20 nm gold layer and by a factor of 164 when adding an additional 20 nm thick layer of SiN. The coating of the imprints significantly improved the stability of the nanopillars, thus making them interesting for a wide range of applications.

9.
EuroIntervention ; 19(2): e176-e187, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37013922

RESUMO

BACKGROUND: Reducing rates of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is important for achieving the best procedural outcomes. The cusp overlap technique (COT) implements procedural steps including an overlap angulation of the right and left coronary cusp to mitigate this complication. AIMS: We investigated the incidence of PPI and complication rates following the COT compared to the standard three-cusp implantation technique (3CT) in an all-comers cohort. METHODS: A total of 2,209 patients underwent TAVI with the self-expanding Evolut platform from January 2016 to April 2022 at five sites. Baseline, procedural and in-hospital outcome characteristics were compared for both techniques before and after one-to-one propensity score matching. RESULTS: A total of 1,151 patients were implanted using the 3CT and 1,058 using the COT. At discharge, the rates of PPI (17.0 vs 12.3%; p=0.002) and moderate/severe paravalvular regurgitation (4.6% vs 2.4%; p=0.006) were significantly reduced with the COT compared with 3CT within the unmatched cohort. Overall procedural success and complication rates were similar; major bleeding was less common in the COT group (7.0% vs 4.6%; p=0.020). These results remained consistent after propensity score matching. In multivariable logistic regression analysis, right bundle branch block (odds ratio [OR] 7.19, 95% confidence interval [CI]: 5.18-10.0; p<0.001) and diabetes mellitus (OR 1.38, 95% CI: 1.05-1.80; p=0.021) emerged as predictors of PPI, whereas the COT (OR 0.63, 95% CI: 0.49-0.82; p<0.001) was protective. CONCLUSIONS: The introduction of the COT was associated with a significant and relevant reduction of PPI and paravalvular regurgitation rates without an increase in complication rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
10.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37119968

RESUMO

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Remodelação Ventricular , Índice de Gravidade de Doença
11.
NMR Biomed ; 36(8): e4927, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36932842

RESUMO

Intravoxel incoherent motion (IVIM) imaging and diffusion tensor imaging (DTI) facilitate noninvasive quantification of tissue perfusion and diffusion. Both are promising biomarkers in various diseases and a combined acquisition is therefore desirable. This comes with challenges, including noisy parameter maps and long scan times, especially for the perfusion fraction f and pseudo-diffusion coefficient D*. A model-based reconstruction has the potential to overcome these challenges. As a first step, our goal was to develop a model-based reconstruction framework for IVIM and combined IVIM-DTI parameter estimation. The IVIM and IVIM-DTI models were implemented in the PyQMRI model-based reconstruction framework and validated with simulations and in vivo data. Commonly used voxel-wise nonlinear least-squares fitting was used as the reference. Simulations with the IVIM and IVIM-DTI models were performed with 100 noise realizations to assess accuracy and precision. Diffusion-weighted data were acquired for IVIM reconstruction in the liver (n = 5), as well as for IVIM-DTI in the kidneys (n = 5) and lower-leg muscles (n = 6) of healthy volunteers. The median and interquartile range (IQR) values of the IVIM and IVIM-DTI parameters were compared to assess bias and precision. With model-based reconstruction, the parameter maps exhibited less noise, which was most pronounced in the f and D* maps, both in the simulations and in vivo. The bias values in the simulations were comparable between model-based reconstruction and the reference method. The IQR was lower with model-based reconstruction compared with the reference for all parameters. In conclusion, model-based reconstruction is feasible for IVIM and IVIM-DTI and improves the precision of the parameter estimates, particularly for f and D* maps.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Movimento (Física) , Imagem de Difusão por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Músculo Esquelético
12.
Hellenic J Cardiol ; 70: 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36538975

RESUMO

OBJECTIVE: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão , Desenho de Prótese , Resultado do Tratamento
13.
Clin Cardiol ; 46(1): 67-75, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36259730

RESUMO

BACKGROUND: Despite major advances, transcatheter aortic valve replacement (TAVR) is still associated with procedure-specific complications. Although previous studies reported lower bleeding rates in patients receiving protamine for heparin reversal, the optimal protamine-to-heparin dosing ratio is unknown. HYPOTHESIS: The aim of this study was a comparison of two different heparin antagonization regimens for the prevention of bleeding complications after TAVR. METHODS: The study included 1446 patients undergoing TAVR, of whom 623 received partial and 823 full heparin antagonization. The primary endpoint was a composite of 30-day mortality, life-threatening, and major bleeding. Safety endpoints included stroke and myocardial infarction at 30 days. RESULTS: Full antagonization of heparin resulted in lower rates of the primary endpoint as compared to partial heparin reversal (5.6% vs. 10.4%, p < .01), which was mainly driven by lower rates of life-threatening (0.5% vs. 1.6%, p = .05) and major bleeding (3.2% vs. 7.5%, p < .01). Moreover, the incidence of major vascular complications was significantly lower in patients with full heparin reversal (3.5% vs. 7.5%, p < .01). The need for red-blood-cell transfusion was lower in patients receiving full as compared to partial heparin antagonization (10.4% vs. 15.9%, p < .01). No differences were observed in the incidence of stroke and myocardial infarction between patients with full and partial heparin reversal (2.2% vs. 2.6%, p = .73 and 0.2% vs. 0.4%, p = .64, respectively). CONCLUSIONS: Full heparin antagonization resulted in significantly lower rates of life-threatening and major bleeding after TAVR as compared to partial heparin reversal. The occurrence of stroke and myocardial infarction was low and comparable between both groups.


Assuntos
Estenose da Valva Aórtica , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Protaminas/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/induzido quimicamente , Infarto do Miocárdio/prevenção & controle , Infarto do Miocárdio/complicações , Valva Aórtica/cirurgia
14.
Front Cardiovasc Med ; 9: 847568, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36119734

RESUMO

Background: The implantation depth (ID) is a critical condition for optimal hemodynamic and clinical outcomes in transcatheter aortic valve replacement (TAVR). The recently recommended cusp-overlap technique (COT) offers optimized fluoroscopic projections facilitating a precise ID. This single-center observational study aimed to investigate short-term clinical performance, safety, and efficacy outcomes in patients undergoing TAVR with self-expandable prostheses and application of COT in a real-world setting. Materials and methods: From September 2020 to April 2021, a total of 170 patients underwent TAVR with self-expandable devices and the application of COT, while 589 patients were treated from January 2016 to August 2020 with a conventional three-cusp coplanar view approach. The final ID and 30-day outcomes were compared after 1:1 propensity score matching, resulting in 150 patients in both cohorts. Results: The mean ID was significantly reduced in the COT cohort (-4.2 ± 2.7 vs. -4.9 ± 2.3 mm; p = 0.007) with an improvement of ID symmetry of less than 2 mm difference below the annular plane (47.3 vs. 57.3%; p = 0.083). The rate of new permanent pacemaker implantation (PPI) following TAVR was effectively reduced (8.0 vs. 16.8%; p = 0.028). While the fluoroscopy time decreased (18.4 ± 7.6 vs. 19.8 ± 7.6 min; p = 0.023), the dose area product increased in the COT group (4951 ± 3662 vs. 3875 ± 2775 Gy × cm2; p = 0.005). Patients implanted with COT had a shorter length of in-hospital stay (8.4 ± 4.0 vs. 10.3 ± 6.7 days; p = 0.007). Conclusion: Transcatheter aortic valve replacement using the cusp-overlap deployment technique is associated with an optimized implantation depth, leading to fewer permanent conduction disturbances. However, our in-depth analysis showed for the first time an increase of radiation dose due to extreme angulations of the gantry to obtain the cusp-overlap view.

15.
Catheter Cardiovasc Interv ; 100(5): 850-859, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35989489

RESUMO

BACKGROUND: A significant number of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) suffer from extra-aortic cardiac damage. Few studies have investigated strategies to quantify cardiac damage and stratify patients accordingly in different risk groups. The aim of this retrospective multicenter study was to provide a user-friendly simplified staging system based on the proposed classification system of Généreux et al. as a tool to evaluate the prognosis of patients undergoing TAVR more easily. Moreover, we analyzed changes in cardiac damage after TAVR. METHODS: We assessed cardiac damage in patients, who underwent TAVR at the Heart Center Bonn or Düsseldorf, using pre- and postprocedural transthoracic echocardiography. Patients were assigned to the staging system proposed by Généreux et al. according to the severity of their baseline cardiac damage. Based on the established system, we created a simplified staging system to facilitate improved applicability. Finally, we compared clinical outcomes between the groups and evaluated changes in cardiac damage after TAVR. RESULTS: A total of 933 TAVR patients were included in the study. We found a significant association between cardiac damage and 1-year all-cause mortality (stage 0: 0% vs. stage 1: 3% vs. stage 2: 6.6%; p < 0.009). In multivariate analysis, cardiac damage was an independent predictor of 1-year all-cause mortality (hazard ratio: 2.0, 95% confidence interval: 1.1-3.8; p = 0.03). CONCLUSIONS: In patients undergoing TAVR, cardiac damage is associated with enhanced mortality. A simplified staging system can help identify patients at high risk for an adverse outcome.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco , Estudos Retrospectivos , Índice de Gravidade de Doença
16.
J Clin Med ; 11(13)2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-35807187

RESUMO

Background: Cerebrovascular events (CVE) are feared complications following transcatheter aortic valve replacement (TAVR). We aimed to develop a new risk model for CVE prediction with the application of multimodal imaging. Methods: From May 2011 to August 2019, a total of 2015 patients underwent TAVR at our institution. The study cohort was subdivided into a derivation cohort (n = 1365) and a validation cohort (n = 650) for risk model development. Results: Of 2015 patients, 72 (3.6%) developed TAVR-related CVE. Pre-procedural factors of our risk model were history of prior CVE, a larger aortic valve area (≥0.55 cm2), a large aortic angulation (≥48.5°), and enhanced calcification of the right coronary cusp (≥447.2 AU), left ventricular outflow tract (≥262.4 AU), and ascending thoracic aorta (≥116.4 AU). Our risk model was superior for in-hospital CVE prediction following TAVR in the establishment cohort (AUC 0.73, 95% CI 0.66−0.80; p < 0.001) compared to other risk scores, such as the EuroSCORE II or the CHA2DS2-VASc score. Conclusions: Although CVE prediction in patients undergoing TAVR is challenging due to the complex nature of the TAVR procedure, our study highlights that multimodal imaging is a promising approach to generate a more accurate risk model for CVE prediction.

17.
J Cardiovasc Dev Dis ; 9(6)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35735818

RESUMO

Due to shortages of medical resources during the Coronavirus Disease 2019 (COVID-19) pandemic, an allocation algorithm for Transcatheter Aortic Valve Replacement (TAVR) was established. We investigated the impact on patient selection and procedural results. In total, 456 TAVR patients before (pre-COVID-19 group) and 456 TAVR patients after (COVID-19 group) the implementation of our allocation algorithm were compared. Concerning patient characteristics, the COVID-19 group revealed a higher rate of cardiac decompensations/cardiogenic shocks (10.5% vs. 1.3%; p < 0.001), severe angina pectoris (Canadian Cardiovascular Society (CCS) II, III and IV: 18.7% vs. 11.8%; p = 0.004), troponin elevation (>14 ng/L: 84.9% vs. 77%; p = 0.003) and reduced left ventricular ejection fraction (LVEF) (<45%: 18.9% vs. 12%; p = 0.006). Referring to procedural characteristics, more predilatations (46.3% vs. 35.1%; p = 0.001) and a longer procedural time (80.2 min (+/−29.4) vs. 66.9 min (+/−17.5); p < 0.001) were observed. The success rate was evenly high; no differences in safety parameters were reported. Examining the utilization of hospital resources, the COVID-19 group showed a shorter in-hospital stay (8.4 days (+/−5.9) vs. 9.5 days (+/−9.33); p = 0.041) and fewer TAVR patients were treated per month (39 (+/−4.55) vs. 46.11 (+/−7.57); p = 0.03). Our allocation algorithm supported prioritization of sicker patients with similar efficient and safe TAVR procedures. In-hospital stay could be shortened.

18.
Clin Res Cardiol ; 111(12): 1358-1366, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35767098

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) stenosis has become more frequent in the last years. This may pose challenges for long-time valve durability. Therefore, we aimed to evaluate the prevalence of bioprosthetic valve dysfunction (BVD) with the newest-generation devices in BAV stenosis up to one-year follow-up (FU). METHODS: The primary endpoint was defined as the prevalence of BVD during the first procedural year according to Valve Academic Research Consortium (VARC)-3 criteria. Secondary endpoints were defined as failure in device success and clinical endpoints according to VARC-3. RESULTS: A total of 107 patients were included. Of these, 34 subjects (31.8%) met the criteria for BVD during a mean FU of 263 ± 180 days, of which 20.2% were already documented after thirty days. Device success after one year was lower in the + BVD cohort (57.6% vs. 98.7%, p < 0.0001*). The rates of structural valve deterioration were 6.5%, non-structural valve deterioration (NSVD) 17.8%, subclinical leaflet thickening 10.3%, and endocarditis 0.9%. NSVD was foremost triggered by patient prosthesis mismatch in balloon-expandable valves. Hemodynamic valve deterioration stage 1 and 2 was confirmed in 16.8% of + BVD patients, while stage 1 and 3 bioprosthetic valve failure occurred in 1.9%. There was no impact of BVD on mortality. CONCLUSION: There is critical evidence of early BVD after TAVI in BAV during one-year FU in one-third of patients, also lowering device success. The most frequently observed bioprosthetic valve dysfunction was NSVD due to patient prosthesis mismatch following TAVI with a balloon-expandable valve.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Constrição Patológica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia
19.
Clin Res Cardiol ; 111(8): 944-954, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35320406

RESUMO

BACKGROUND: Clinical data regarding the association between the left atrial function index (LAFI) and outcome in patients undergoing transcatheter aortic valve replacement (TAVR) are limited. OBJECTIVES: We aimed to investigate the association between the left atrial function index (LAFI) and outcome in patients undergoing TAVR. METHODS: In this retrospective multicenter study, we assessed baseline LAFI in 733 patients undergoing TAVR for severe aortic stenosis in two German high-volume centers between 2008 and 2019. Based on receiver operating characteristic curves, patients were stratified according to their baseline LAFI into two groups (LAFI ≤ 13.5 vs. LAFI > 13.5) and assessed for post-procedural outcome. The primary endpoint of our study was the 1-year all-cause mortality. RESULTS: Patients with a LAFI ≤ 13.5 had significantly more often atrial fibrillation (p < 0.001), lower LVEF (p < 0.001) and higher levels of NT-proBNP (p < 0.001). After TAVR, a significant improvement in the LAFI as compared to baseline was observed at 12 months after the procedure (28.4 vs. 32.9; p = 0.001). Compared to patients with a LAFI > 13.5, those with a LAFI ≤ 13.5 showed significantly higher rate of 1-year mortality (7.9% vs. 4.0%; p = 0.03). A lower LAFI has been identified as independent predictor of mortality in multivariate analysis (HR (95% CI) 2.0 (1.1-3.9); p = 0.03). CONCLUSION: A reduced LAFI is associated with adverse outcome and an independent predictor of mortality in TAVR patients. TAVR improves LAFI within 12 months after the procedure. Left Atrial Function Index (LAFI) in Patients undergoing Transcatheter Aortic Valve Implantation. A Kaplan-Meier survival analysis of 1-year all-cause mortality in patients with LAFI ≤ 13.5 compared with patients with LAFI > 13.5. Comparing rates of 1-year all-cause mortality between the different LAFI groups, we found a significant association between left atrial function and mortality. LAFI Left atrial function index. B Comparison of the mean LAFI before and after TAVR. After long-term follow-up the LAFI improved significantly. LAFI Left atrial function index; FU follow-up. C Assessment of the left atrial function index using the pre-procedural transthoracic echocardiography. A Measurement of the minimal left atrial volume (LAEDV). B Assessment of the maximal left atrial volume (LAESV).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Função do Átrio Esquerdo , Ecocardiografia/métodos , Humanos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
20.
Heart ; 108(18): 1479-1485, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-35039329

RESUMO

OBJECTIVES: This study aimed to investigate early haemodynamic and clinical performance of the SAPIEN 3 Ultra (S3 Ultra) transcatheter heart valve (THV) system in comparison to its precursor, the SAPIEN 3 (S3). Previous studies have indicated potential haemodynamic differences between the S3 Ultra and S3. Such differences may impact clinical outcome after transcatheter aortic valve implantation (TAVI). METHODS: Postprocedural haemodynamic performance and 30-day clinical outcome were compared in patients who underwent TAVI receiving either the S3 or the new S3 Ultra prostheses. Multivariable analysis and propensity score matching (PSM) were used to identify factors associated with higher mean transvalvular gradients. RESULTS: We included 697 patients (S3 Ultra: n=314, S3: n=383) from the multicentre RhineHeart TAVI Registry. Patients receiving the S3 Ultra prosthesis showed significantly higher postprocedural mean transvalvular gradients (14.2±4.8 vs 10.2±4.4 mm Hg; p<0.01). Multivariable logistic regression analyses and additional PSM revealed the use of the S3 Ultra to be associated with higher postprocedural mean transvalvular gradients (p<0.01). 30-day clinical outcomes, such as mortality, myocardial infarction, permanent pacemaker implantation and vascular complications were comparable between the groups. CONCLUSIONS: The new S3 Ultra THV was associated with a higher postprocedural mean transvalvular gradient compared with the S3 system, while there was no difference in mortality or adverse clinical outcomes at 30 days. These echocardiographic differences will require long-term studies to assess the clinical relevance of this finding.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...