1.
Catheter Cardiovasc Interv ; 102(7): 1222-1228, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37948428

RESUMO

BACKGROUND: The Synergy MegatronTM is an everolimus-drug eluting stent that may offer advantages in the treatment of aorto-ostial disease and large proximal vessels. AIMS: To report the short- to medium-term clinical outcomes from the European Synergy MegatronTM Implanters' Registry. METHODS: This registry was an investigator-initiated study conducted at 14 European centers. The primary outcome was target lesion failure (TLF), defined as the composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularisation. RESULTS: Five hundred seventy-five patients underwent PCI with MegatronTM between 2019 and 2021. Patients were 69 ± 12 years old, 26% had diabetes mellitus, 24% had moderate-severe left ventricular impairment and 59% presented with an acute coronary syndrome. 15% were deemed prohibitively high risk for surgical revascularisation. The target vessel involved the left main stem in 55%, the ostium of the RCA in 13% and was a true bifurcation (Medina 1,1,1) in 50%.  At 1 year, TLF was observed in 40 patients, with 26 (65%) occurring within the first 30 days. The cumulative incidence of TLF was 4.5% at 30 days and 8.6% (95% CI 6.3-11.7) at 1 year. The incidence of stent thrombosis was 0.5% with no late stent thromboses. By multivariate analysis, the strongest independent predictors of TLF were severe left ventricular impairment (HR 3.43, 95% CI: 1.67-6.76, p < 0.001) and a target vessel involving the left main (HR 4.00 95% CI 1.81-10.15 p = 0.001). CONCLUSIONS: Use of the Synergy MegatronTM everolimus eluting stent in a 'real-world' setting shows favorable outcomes at 30 days and 1 year.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Everolimo/efeitos adversos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
2.
Microvasc Res ; 147: 104480, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36690270

RESUMO

OBJECTIVE: Coronary microvascular dysfunction (CMD) is a cause of ischaemia with non-obstructive coronary arteries (INOCA). It is notoriously underdiagnosed due to the need for invasive microvascular function testing. We hypothesized that systemic microvascular dysfunction could be demonstrated non-invasively in the microcirculation of the bulbar conjunctiva in patients with CMD. METHODS: Patients undergoing coronary angiography for the investigation of chest pain or dyspnoea, with physiologically insignificant epicardial disease (fractional flow reserve ≥0.80) were recruited. All patients underwent invasive coronary microvascular function testing. We compared a cohort of patients with evidence of CMD (IMR ≥25 or CFR <2.0); to a group of controls (IMR <25 and CFR ≥2.0). Conjunctival imaging was performed using a previously validated combination of a smartphone and slit-lamp biomicroscope. This technique allows measurement of vessel diameter and other indices of microvascular function by tracking erythrocyte motion. RESULTS: A total of 111 patients were included (43 CMD and 68 controls). There were no differences in baseline demographics, co-morbidities or epicardial coronary disease severity. The mean number of vessel segments analysed per patient was 21.0 ± 12.8 (3.2 ± 3.5 arterioles and 14.8 ± 10.8 venules). In the CMD cohort, significant reductions were observed in axial/cross-sectional velocity, blood flow, wall shear rate and stress. CONCLUSION: The changes in microvascular function linked to CMD can be observed non-invasively in the bulbar conjunctiva. Conjunctival vascular imaging may have utility as a non-invasive tool to both diagnose CMD and augment conventional cardiovascular risk assessment.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Humanos , Estudos Transversais , Estudos Prospectivos , Hemodinâmica , Angiografia Coronária/métodos , Vasos Coronários , Microcirculação , Túnica Conjuntiva , Circulação Coronária
3.
Cardiovasc Revasc Med ; 50: 26-33, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36707373

RESUMO

BACKGROUND: Atherosclerotic heart disease often remains asymptomatic until presentation with a major adverse cardiovascular event. Primary preventive therapies improve outcomes, but conventional screening often misattributes risk. Vascular imaging can be utilised to detect atherosclerosis, but often involves ionising radiation. The conjunctiva is a readily accessible vascular network allowing non-invasive hemodynamic evaluation. AIM: To compare conjunctival microcirculatory function in patients with and without obstructive coronary artery disease. METHODS: We compared the conjunctival microcirculation of myocardial infarction patients (MI-cohort) to controls with no obstructive coronary artery disease (NO-CAD cohort). Conjunctival imaging was performed using a smartphone and slit-lamp biomicroscope combination. Microvascular indices of axial (Va) and cross-sectional (Vcs) velocity; blood flow rate (Q); and wall shear rate (WSR) were compared in all conjunctival vessels between 5 and 45 µm in diameter. RESULTS: A total of 127 patients were recruited (66 MI vs 61 NO-CAD) and 3602 conjunctival vessels analysed (2414 MI vs 1188 NO-CAD). Mean Va, Vcs and Q were significantly lower in the MI vs NO-CAD cohort (Va 0.50 ± 0.17 mm/s vs 0.55 ± 0.15 mm/s, p < 0.001; Vcs 0.35 ± 0.12 mm/s vs 0.38 ± 0.10 mm/s, p < 0.001; Q 154 ± 116 pl/s vs 198 ± 130 pl/s, p < 0.001). To correct for differences in mean vessel diameter, WSR was compared in 10-36 µm vessels (3268/3602 vessels) and was lower in the MI-cohort (134 ± 64 s-1 vs 140 ± 63 s-1, p = 0.002). CONCLUSIONS: Conjunctival microcirculatory alterations can be observed in patients with obstructive coronary artery disease. The conjunctival microvasculature merits further evaluation in cardiovascular risk screening.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Microcirculação/fisiologia , Estudos Transversais , Túnica Conjuntiva/irrigação sanguínea , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária
4.
Interv Cardiol ; 17: e09, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35891630

RESUMO

Spontaneous coronary artery dissection (SCAD) is a less common cause of acute coronary syndrome. Pregnancy-related SCAD is uncommon, but often presents with a more severe phenotype. This report describes a 30-year-old woman with an anterior ST elevation MI, presenting 1 day postpartum. Left main stem (LMS) SCAD with extensive intramural haematoma (IMH) and resultant LMS occlusion was confirmed by angiography and intravascular imaging. Given the extent of disease, the patient underwent emergency cardiac surgery. Coronary flow was initially improved by decompressing the IMH using cutting balloons. The coronary wires were successfully left in situ during transfer in an effort to both maintain flow and allow the surgeon to identify true LMS. Ideally, SCAD can be managed conservatively given the risk of intervention worsening IMH, and hence myocardial ischaemia/MI. However, emergency revascularisation is indicated in cases of persistent ischaemia. This case demonstrates percutaneous therapies to bridge towards and help with subsequent surgical revascularisation.

5.
Sci Rep ; 12(1): 6545, 2022 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-35449196

RESUMO

Microvascular haemodynamic alterations are associated with coronary artery disease (CAD). The conjunctival microcirculation can easily be assessed non-invasively. However, the microcirculation of the conjunctiva has not been previously explored in clinical algorithms aimed at identifying patients with CAD. This case-control study involved 66 patients with post-myocardial infarction and 66 gender-matched healthy controls. Haemodynamic properties of the conjunctival microcirculation were assessed with a validated iPhone and slit lamp-based imaging tool. Haemodynamic properties were extracted with semi-automated software and compared between groups. Biomarkers implicated in the development of CAD were assessed in combination with conjunctival microcirculatory parameters. The conjunctival blood vessel parameters and biomarkers were used to derive an algorithm to aid in the screening of patients for CAD. Conjunctival blood velocity measured in combination with the blood biomarkers (N-terminal pro-brain natriuretic peptide and adiponectin) had an area under receiver operator characteristic curve (AUROC) of 0.967, sensitivity 93.0%, specificity 91.5% for CAD. This study demonstrated that the novel algorithm which included a combination of conjunctival blood vessel haemodynamic properties, and blood-based biomarkers could be used as a potential screening tool for CAD and should be validated for potential utility in asymptomatic individuals.


Assuntos
Algoritmos , Túnica Conjuntiva , Biomarcadores , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Túnica Conjuntiva/irrigação sanguínea , Humanos , Microcirculação
6.
J Invasive Cardiol ; 34(5): E380-E389, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35394450

RESUMO

OBJECTIVES: To define the optimal implantation of the Sapien 3 (Edwards Lifesciences) transcatheter heart valve (THV), this study systematically analyzed the predeployment fluoroscopic THV position and correlated this to clinical outcomes. METHODS: This was an observational study of 279 patients treated with the Sapien 3 THV. Fluoroscopic imaging was used to categorize patients into low (n = 147), intermediate (n = 86), and high (n = 46) implantation zones. These zones were based on the relationship of the balloon marker and radiolucent line of the valve frame (line of lucency) to the annular plane at deployment. The primary outcome was the rate of permanent pacemaker implantation (PPI) at 30 days. The secondary outcomes were the rates of new left bundle-branch block (LBBB) in-hospital and all-cause mortality at 1 year. RESULTS: In the high, intermediate, and low groups, 30-day PPI rates were 4.3%, 8.1%, and 8.8% (P=.62); in-hospital LBBB rates were 10.9%, 26.7%, and 32.0% (P=.02); and all-cause mortality rates at 1 year were 3.1%, 7.3%, and 12.5% (P=.14), respectively. No differences were observed with respect to procedural success/complications or THV performance between the groups. CONCLUSION: This study demonstrates fewer conduction abnormalities for Sapien 3 valves positioned within a higher zone defined fluoroscopically by the line of lucency and balloon marker.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Curr Cardiol Rev ; 18(1): e170621194128, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34139985

RESUMO

The 'gold standard' in the management of left main coronary artery disease has historically been coronary artery bypass surgery. Recent innovations in drug-eluting stent technology coupled with the increasing utility of physiology and imaging guidance for procedures have led to an evolving role of percutaneous coronary intervention in left main disease of low and intermediate anatomical complexity. This revascularization modality carries the clear advantage of being less invasive and significantly reduced recovery times. This practice is currently supported by international guidelines, however, it remains a controversial topic in the field of interventional cardiology, and the long-term outcomes of a percutaneous strategy have been questioned. This review describes the current evidence base for the assessment and choice of intervention in left main coronary artery disease. The percutaneous revascularization techniques and use of imaging to optimize procedures and improve clinical outcomes have been discussed.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
8.
J Invasive Cardiol ; 33(10): E784-E790, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34609325

RESUMO

BACKGROUND: Outcomes from the new Synergy Megatron drug-eluting stent (DES) platform (Boston Scientific) are not yet reported. This study sought to evaluate periprocedural outcomes in patients undergoing percutaneous coronary intervention (PCI) using this technology. METHODS: This was a retrospective study across two United Kingdom centers of 139 patients undergoing PCI of 146 coronary lesions using the Synergy Megatron DES. The primary endpoint was the rate of cardiovascular death. The secondary endpoint was the rate of a composite of non-fatal myocardial infarction, target-vessel revascularization, in-stent restenosis, and probable/definite stent thrombosis. Available intravascular ultrasound (IVUS) imaging was reviewed post hoc and evaluated according to predefined IVUS optimization criteria. RESULTS: Mean follow-up duration was 137.3 ± 38.3 days. The primary endpoint occurred in 0.7% of patients and the secondary endpoint occurred in 0.0% of patients. There were no cases of longitudinal stent deformation (LSD); in patients undergoing an IVUS-guided procedure, our criteria for successful IVUS optimization was achieved in 74.1% of left main stem (LMS) and 83.3% of right coronary artery (RCA) lesions. Mean minimal stent area (MSA) was 14.5 ± 3.4 mm² in the LMS, 10.0 ± 2.5 mm² in the left anterior descending coronary artery, 9.8 ± 3.0 mm² in the left circumflex, and 12.2 ± 4.0 mm² in the RCA. CONCLUSION: This study demonstrated very low rates of short-term major adverse cardiovascular events with no cases of LSD or acute/subacute stent thrombosis. It highlights the overexpansion capabilities of the Synergy Megatron DES platform. The technology safely and effectively facilitates IVUS-optimized stent parameters for the treatment of large proximal vessels and bifurcations.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Everolimo/farmacologia , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção