Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; : 15266028241270861, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39188184

RESUMO

PURPOSE: Endovascular aortic repair (EVAR) is currently expanding its feasibility thanks to design innovations, but hostile proximal necks and narrow iliac arteries are still a constraint, as expressed by the Instructions for Use (IFU) of most devices. Our aim is to report the preliminary results of the E-Tegra endograft in infrarenal abdominal aortic aneurysms (AAAs) performed in 15 high-volume centers. MATERIALS AND METHODS: The e-Tegra Italian endoGraft REgistry (TIGRE) is a prospectively maintained database of consecutive EVAR with the E-Tegra stent-graft across 15 participating centers between March 2021 and March 2023. The registry records baseline clinical data, anatomic measurements of the abdominal aorta, perioperative and postoperative outcomes, with a scheduled follow-up period of 3 years for all patients. This is a preliminary analysis of the first results updated to January 2024. The primary endpoints are technical and clinical success, perioperative mortality, freedom from endograft rupture, and aortic-related mortality. The secondary endpoints are freedom from reintervention, and any type of endoleak (EL). The results were analyzed in relation with the anatomic characteristics of the AAAs, namely, iliac axes tortuosity and proximal neck hostility. RESULTS: The registry included 147 consecutive EVAR (138 elective and 9 in emergent setting), 7 of which were associated with an iliac branch implantation. Ninety patients had at least 1 criterion of anatomical hostility, and 25 were treated outside the device IFU. Primary technical success was achieved in 146 cases (99.3%) and assisted success in 147 (100%), with no perioperative mortality. After a median follow-up period of 20 months, no aneurysm-related mortality occurred. Reinterventions were 5: 2 for type IB EL and 3 for type II ELs with aneurysm sac increase. Five more type II ELs with aneurysm sac stability are under observation. No differences in terms of reinterventions were noted between aneurysms with standard and hostile anatomy. CONCLUSION: The E-Tegra endograft is safe and effective in treating AAAs with standard and hostile anatomy, with a low rate of complications and reinterventions, although longer-term outcomes and larger numbers are needed to compare its performances related to specific anatomic criteria. CLINICAL IMPACT: This multi-center nationwide Registry reports a real-world experience of EVAR performed with the E-Tegra abdominal endograft across 15 high-volume Centers, providing early- and mid-term device-specific results, which will help vascular surgeons in endograft selection. In particular, this study focuses on clinical results obtained in treating aneurysms with hostile anatomy, analyzing the performances of the E-Tegra endograft in cases of hostile proximal necks and narrow or tortuous iliac axes.

2.
3.
Cardiovasc Intervent Radiol ; 46(12): 1674-1683, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37978065

RESUMO

PURPOSE: Comparison of hybrid and total endovascular aortic arch repair at two tertiary vascular surgery centers. MATERIALS AND METHODS: Consecutive patients undergoing hybrid (HG) or total endovascular (TEG) total aortic arch repair for aneurysms or dissections were included (2008-2022). Primary outcome measure was 30-day mortality. Secondary outcomes were major complications, technical success (defined as absence of surgical conversion/mortality, high-flow endoleaks or branch/limb occlusion), clinical success (defined as absence of disabling clinical sequelae), late and aortic-related mortality/reinterventions, freedom from endoleaks, aortic diameter growth > 5 mm, graft migration and supra-aortic trunks (SAT) patency. RESULTS: In total, 30 patients were included, 17 in HG and 13 in TEG. TEG presented shorter intervention time (240.5 vs 341 min, p = 0.01), median ICU stay (1 vs 4.5 days, p < 0.01) and median length of stay (8 vs 17.5 days, p < 0.01). No intraoperative deaths occurred. Technical success was 100%; clinical success was 70.6% in HG and 100% in TEG (p = 0.05). Thirty-day mortality was 13.3%, exclusively in HG (p = 0.11). Nine major complications occurred in 8 patients, 5 in HG and 3 in TEG (p = 0.99), among which five strokes, two in HG and three in TEG (p = 0.62). Late mortality was 38.5%, six patients in HG and four in TEG, p = 0.6. Two late aortic-related deaths occurred in HG (p = 0.9). Two aortic-related reinterventions, no graft migration or SAT occlusion was observed. CONCLUSIONS: Total endovascular repair seems to shorten operative times and provide higher clinical success compared with hybrid solutions, without significant 30-day mortality differences. The most common major complication is stroke.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Endoleak/cirurgia , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Aneurisma/cirurgia , Acidente Vascular Cerebral/cirurgia , Estudos Retrospectivos , Fatores de Risco
4.
EJVES Vasc Forum ; 54: 41-43, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35098196

RESUMO

INTRODUCTION: Acute thrombosis of an infrarenal abdominal aortic aneurysm (ATAAA) represents an uncommon but catastrophic pathology, which can lead to life threatening complications. This is a report of the infrequent use of an endovascular solution to successfully treat ATAAA in a patient with COVID-19 viral pneumonia and ischaemia induced lower extremity neurological deficits. REPORT: An 89 year old white male, with a history of cardiovascular comorbidities was admitted to the emergency room with dyspnoea associated with the sudden onset of abdominal and back pain followed by partial motor and sensory deficits in both legs. The CT scan showed both an 8 cm infrarenal AAA with middle (inferior mesenteric artery patent) and distal thrombotic occlusion of the sac and non-aneurysmal but thrombosed common iliac arteries. An additional finding was imaging features typical of interstitial pneumonia. After the molecular test detected active COVID-19 infection, the patient was treated as an emergency with an aorto-uni-iliac stent graft and femorofemoral crossover graft. The post-operative course was uneventful with AAA exclusion and disappearance of ischaemic symptoms. There were no vascular complications. At three month follow up the patient remained asymptomatic and was looking after himself. DISCUSSION: This case supports the feasibility and safety of a minimally invasive endovascular procedure to treat ATAAA in selected patients with favourable anatomy and high risk of respiratory complications in the context of the COVID-19 pandemic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA