Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Cardiol ; 248: 396-402, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28807509

RESUMO

OBJECTIVES: Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. METHODS: A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. RESULTS: Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. CONCLUSIONS: PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification.


Assuntos
Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/etiologia , Contaminação de Equipamentos , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/microbiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Circulation ; 132(12): 1113-26, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26276890

RESUMO

BACKGROUND: The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/computed tomography (CT) and (18)F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit. METHODS AND RESULTS: Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% (P<0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT (P=0.006) or echocardiography (P<0.001). CONCLUSIONS: (18)F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.


Assuntos
Angiografia/métodos , Desfibriladores Implantáveis/microbiologia , Endocardite/diagnóstico , Próteses Valvulares Cardíacas/microbiologia , Marca-Passo Artificial/microbiologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Arritmias Cardíacas/terapia , Ecocardiografia , Endocardite/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18 , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...